Labshake search
Citations for Sutter Instruments :
151 - 200 of 503 citations for 7 11 Dimethyldodeca 4 6 10 trien 3 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2019Quote: ... A 3-axis-knob (ROE-200) or joystick (Xenoworks BRJOY, Sutter Instruments) connected to the manipulator via a controller box (MPC-200 ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes were pulled from borosilicate glass (3-5 MΩ, Sutter Instruments). For voltage clamp recordings ...
-
bioRxiv - Biophysics 2023Quote: ... were pulled to a resistance of 3–7MΩ (P-1000; Sutter Instrument) and filled with an internal solution containing (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... Excitation light was from a Lambda DG-4 (Sutter Instruments) and it was passed through an excitation filter (AmCyan,Chroma) ...
-
bioRxiv - Neuroscience 2020Quote: ... A switching galvanometer system (Lambda DG-4 Sutter Instruments Company) with 4 wavelength filters (λ — 495 ± 31 ...
-
bioRxiv - Neuroscience 2022Quote: ... A Lambda DG-4 (Sutter Instrument Company, Novato CA, USA) white light source was used to illuminate the samples through a GFP excitation/emission filter set ...
-
bioRxiv - Neuroscience 2022Quote: ... using a Lambda DG-4 fast beam switcher (Sutter Instruments) with a xenon lamp and ET470/40nm band pass filter ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes (10-15 MΩ) were pulled from borosilicate capillary glass (BF150-86-10, Sutter Instruments, Novato ...
-
bioRxiv - Physiology 2020Quote: ... glass microelectrodes were pulled to a tip resistance of 5-7 MΩ on a Flaming-Brown P-1000 Micropipette puller (Sutter Instruments, Novato, CA, USA). TPP was measured with a Duo 773 intracellular/extracellular amplifier (World Precision Instruments ...
-
bioRxiv - Physiology 2023Quote: ... pulled to form low resistance tips (approximately 5–7 MΩ) using a model P-87 Flaming/Brown micropipette puller (Sutter Instruments, Novato, CA, USA). These microelectrodes were backfilled with 500 mM KCl ...
-
bioRxiv - Neuroscience 2021Quote: ... Glass pipettes of ∼3 MΩ resistance (Model P-1000, Sutter instruments, Novato, CA) were filled with extracellular solution and positioned near PN axon hillocks in order to measure action potential-associated capacitive current transients in voltage clamp mode with the pipette potential held at 0 mV ...
-
bioRxiv - Neuroscience 2022Quote: ... which was mounted on a motorized 3-axis micromanipulator (MP-285, Sutter Instrument). Optical irradiance for optogenetic stimulation was set to 10 mW·mm-2 at the tissue surface ...
-
bioRxiv - Biophysics 2023Quote: ... were pulled using a micropipette puller (P-2000, Sutter Instruments; 2-3 MΩ). Pipettes were filled using the internal solution as follows (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... on a 4-step micropipette P-90puller (Sutter Instruments, Novato, CA). The internal solution contained the following (in mM) ...
-
bioRxiv - Cell Biology 2022Quote: ... glass capillaries (Sutter Instruments, #BF100-78-10) were pulled using a micropipette puller (Sutter Model P-2000 ...
-
bioRxiv - Biophysics 2019Quote: Microelectrodes (Sutter Instrument, Item #: B150-117-10) were made with a Sutter (P-97 ...
-
bioRxiv - Developmental Biology 2022Quote: ... a micropipette beveller (BV-10, Sutter Instrument) was used to increase sharpness of the pipette tips ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... quartz needles (Sutter Instrument, QF100-70-10) were pulled using a P2000 micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (3-5 MΩ) were pulled from borosilicate glass capillaries (Sutter Instruments, USA) with an outer diameter of 1.5 mm on a four-stage horizontal puller (P1000 ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (3-5 MΩ) were pulled from a horizontal puller (P1000, Sutter Instruments) and filled with the internal solution that contained (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... with a long taper (more than 6 mm) were pulled with a pipette puller (Sutter Instruments, model P-97) for TG injection ...
-
bioRxiv - Neuroscience 2023Quote: ... Borosilicate glass pipettes (O.D. = 1.5 mm, I.D. = 0.86 mm, length = 10 cm, item#: BF150-86-10, Sutter Instruments, Novato, CA) were pulled by micropipette puller (P1000 ...
-
bioRxiv - Physiology 2019Quote: ... A 4-step pulling protocol using a horizontal puller (P97, Sutter Instruments) was optimized to obtain a short shaft (∼8 mm ...
-
bioRxiv - Neuroscience 2022Quote: ... CFP and YFP were detected using Lambda DG-4 monochromator (Sutter Instruments) coupled to the microscope through an optic fiber with appropriate filters (excitation ...
-
bioRxiv - Neuroscience 2023Quote: ... We filled patch pipettes (2-4 MΩ) pulled (P-97, Sutter Instrument) from borosilicate capillary glass (Sutter Instrument ...
-
bioRxiv - Neuroscience 2020Quote: ... The patch pipettes were pulled to yield an impedance of 6–8 MΩ on a horizontal pipette puller (Sutter Instrument) from thin-walled ...
-
bioRxiv - Neuroscience 2023Quote: Pipettes with resistance of 3.5-6 MΩ were fabricated from borosilicate filamented capillaries using the P-97 micropipette puller (Sutter Instrument). The pipettes were filled with an internal solution composed of 8mM NaCl ...
-
bioRxiv - Cell Biology 2020Quote: ... Borosilicate glass pipettes (Sutter Instrument BF100-58-10) with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000) ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass pipettes (Sutter Instrument BF100-58-10) with resistances ranging 3–6 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000) ...
-
bioRxiv - Neuroscience 2022Quote: ... Borosilicate glass pipettes (Sutter Instrument BF100-58-10) with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000) ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass pipettes (Sutter Instrument BF100-58-10) with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000) ...
-
bioRxiv - Neuroscience 2022Quote: ... Borosilicate glass pipettes (BF150-86-10, Sutter Instrument) were fabricated using P-97 puller (Sutter Instrument ...
-
bioRxiv - Physiology 2022Quote: ... The glass electrodes (Sutter instruments, BF150-75-10) were fabricated by identical micropipette puller ...
-
bioRxiv - Physiology 2022Quote: ... The glass electrodes (Sutter instruments, BF150-86-10) were prepared using micropipette puller (Sutter instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... borosilicate glass (BF150-86-10, Sutter Instruments, USA) and had resistances of 3 - 5 MΩ ...
-
bioRxiv - Microbiology 2023Quote: ... LAMBDA 10-B Smart Shutter from Sutter Instrument, an OkoLab stage incubator ...
-
bioRxiv - Developmental Biology 2023Quote: ... The quartz capillary (Sutter Instrument, QF100-70-10) was pulled by Laser-Based Micropipette Puller P2000 (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2023Quote: ... sharp borosilicate microelectrodes (BF150-86-10, Sutter Instruments) with impedance of 60-120 MOhms were filled with 3M KCl and mounted on a 3-axis micromanipulator to be slowly advanced into the superior division of CNVIII just as it exits the otic capsule ...
-
bioRxiv - Biophysics 2023Quote: ... Borosilicate glass pipettes (BF100-58-10, Sutter Instruments) were pulled using a micropipette puller (P-2000 ...
-
bioRxiv - Molecular Biology 2023Quote: ... motorized filter wheel (Lambda 10-B; Sutter Instruments), and a high-speed sCMOS camera equipped with light-sheet mode capability (ORCA-Fusion BT ...
-
bioRxiv - Neuroscience 2023Quote: ... borosilicate glass pipettes (BF150-86-10, Sutter Instrument) with resistance 3-5 MΩ were pulled (P-1000 ...
-
bioRxiv - Developmental Biology 2024Quote: ... and 1 mm (BF200-100-10, SUTTER INSTRUMENTS) for 70 days old coricOs.
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes (BF150-86-10, Sutter Instrument) were pulled using a pipette puller (P-97 ...
-
bioRxiv - Cell Biology 2024Quote: ... Borosilicate glass capillaries (Sutter Instrument; B100-50-10) were pulled into needles on a needle puller (Sutter instruments P1000) ...
-
bioRxiv - Neuroscience 2024Quote: Sharp borosilicate microelectrode (BF150-86-10, Sutter Instruments) with impedance 60-120 MOhms was used to record extracellular spike activity from spontaneously discharging vestibular afferents ...
-
bioRxiv - Biophysics 2023Quote: ... Borosilicate glass micropipettes (Sutter Instruments BF150-86-10) were pulled and fire-polished to a tip diameter with a resistance of 1.8 to 3.4 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... Postsynaptic patch pipettes (BF150-86-10, Sutter Instrument) had a resistance of 3-7 MΩ and series resistance (Rs ...
-
bioRxiv - Neuroscience 2023Quote: ... Presynaptic patch pipettes (BF150-86-10, Sutter Instrument) had a resistance of 15-20 MΩ and series resistance (Rs ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (3-5 MΩ) were pulled using P-97 puller (Sutter instruments, Novato, CA) and filled with internal solutions contained (in mM) ...
-
bioRxiv - Bioengineering 2023Quote: ... were pulled to ∼3-5 MW resistance with a micropipette puller (Sutter Instruments; P-97) and polished with a microforge (Narishige ...