Labshake search
Citations for Sutter Instruments :
301 - 350 of 419 citations for 6 methyl 4 oxo N phenyl 2 3 dihydro 1 4 oxathiine 5 carboxamide since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes of 5–10 MΩ were pulled with a P-97 Flaming/Brown puller (Sutter Instruments) from borosilicate glass capillaries and the intracellular solution used contained (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes were pulled to tip resistances of 5-8 MΩ using a multistage puller (Sutter Instruments) and were filled with intracellular solution ...
-
bioRxiv - Cell Biology 2020Quote: ... These filters were alternated by a filter-changer Lambda 10–2(Sutter Instruments, Novato, CA). Exposure time was 50–500 ms ...
-
bioRxiv - Immunology 2023Quote: ... The fluorescence lamp of setup #2 was equipped with one filter wheel (Sutter Instrument Company) with the following filters installed ...
-
bioRxiv - Immunology 2023Quote: ... and setup #2 was coupled to a xenon lamp (Lambda LS lamp, Sutter Instrument Company). Fluorescence lamp illumination was realized by using various sets of filters in the excitation path ...
-
bioRxiv - Neuroscience 2020Quote: ... Imaging of dorsal DG was performed with a 2-photon laser scanning microscope (MOM, Sutter Instruments) using a 1070 nm femtosecond-pulsed laser (Fidelity 2 ...
-
bioRxiv - Neuroscience 2021Quote: ... USA) was used to pull patch pipettes (3–6MΩ) on a horizontal Flaming/Brown micropipette puller (P-97, Sutter Instruments, Novato, CA, USA). PVN neurons were selected for whole-cell patch-clamp recordings using DIC videomicroscopy and epifluorescence (retrogradely-labeled neurons) ...
-
bioRxiv - Physiology 2019Quote: ... borosilicate glass capillaries were pulled to a tip diameter of ~3 μm using a micropipette puller (Flaming Brown P-97, Sutter Instruments, Novato, USA), heated to 300°C ...
-
bioRxiv - Plant Biology 2019Quote: ... at the top of each rhizotron and loaded the rhizotron into a fixed stage that was controlled by a Lambda 10-3 optical filter changer (Sutter Instruments, Novato, CA) in the GLO1 imaging system (Rellán-Álvarez et al. ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (4-8 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) with a micropipette puller (P-87, Sutter Instruments, Novato, CA) and filled with a potassium gluconate-based intracellular solution containing either (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (4–8 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) using a micropipette puller (P-87, Sutter Instruments, Novato, CA) and filled with a KGlu based intra-pipette solution containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes were prepared from borosilicate glass capillaries (G150F-3; Warner Instruments, Hamden, CT) using a P-1000 micropipette puller (Sutter Instruments, Novato, CA) and subsequently fire polished ...
-
bioRxiv - Neuroscience 2021Quote: ... L2/3 responses were probed between 200-300 microns from the cortical surface using a micromanipulator (MP-285, Sutter Instrument Company, Novato, CA). Signals were acquired after passing through unity gain (1x ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes were prepared from borosilicate glass capillaries (G150F-3; Warner Instruments, Hamden, CT) using a P-1000 micropipette puller (Sutter Instruments, Novato, CA) and were subsequently fire-polished ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4–8 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) using a micropipette puller (P-87, Sutter Instruments, Novato, CA) and filled with a potassium gluconate (KGlu)-based intrapipette solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate pipettes of 5 – 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter instruments). All recordings were done in current clamp with an intracellular solution containing 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2020Quote: The STG was desheathed dorsally and neuron somata were impaled using glass microelectrodes (ID: 0.86 mm; OD: 1.5 mm; 5-20 MΩ; Sutter Instrument). Microelectrodes were backfilled with a solution containing 10 mM MgCl2 ...
-
bioRxiv - Neuroscience 2022Quote: ... Data were filtered at 5 kHz and sampled at 10 kHz and stored in a computer (Sutter Instrument Co.). The standard internal pipette solution for whole-cell voltage-clamp contained (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell patch-clamp recordings were performed using glass pipette electrodes (resistance 3–7 MΩ) pulled from borosilicate capillaries (BF150-86-10, Sutter Instruments, Novato, CA, USA) using a P-97 pipette puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch electrodes with a resistance of 3-5MΩ were guided to neurons with an MPC-200-ROE controller and MP285 mechanical manipulator (Sutter Instruments, Novato, CA, USA). Patch-clamp recordings were collected through a UPC-10 USB dual digital amplifier and Patchmaster NEXT recording software (HEKA Elektronik GmbH ...
-
bioRxiv - Cell Biology 2023Quote: ... and emission light was separated using interference (530/50 nm, 590/20-nm) or longpass (650LP) filters (Semrock) mounted in a filter wheel (Sutter instruments Lambda 10-3). An electronic shutter was used to block light exposure between image captures ...
-
bioRxiv - Biophysics 2020Quote: ... Borosilicate and quartz nanopipettes were fabricated with a CO-2 laser puller (Model P-2000, Sutter Instruments) with a radius from 40 nm to 60 nm and 20 nm to 40 nm respectively.
-
bioRxiv - Neuroscience 2020Quote: ... under the control of the Sutter filter wheel shutter controller (Lambda 10-2, Sutter Instrument, Novato, CA). All data were sampled at 3-10 kHz ...
-
bioRxiv - Neuroscience 2022Quote: ... pipette tip diameter: 2 μm) were pulled from borosilicate glass using a P-97 puller (Sutter Instruments) and filled with intracellular solution (containing in mM ...
-
bioRxiv - Cell Biology 2019Quote: ... Glass pipettes with a resistance of 2.5 – 5 MΩ measured with physiological solutions (below) were pulled using an automatic P-97 Micropipette Puller system (Sutter Instruments).
-
bioRxiv - Neuroscience 2020Quote: ... World Precision) to obtain pipette resistance ranging from 5 – 8 MΩ using next generation micropipette puller (P-1000, Sutter Instrument). External solution is consist of 140 mM NaCl ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (resistance 5-10 MΩ, pulled using a P-87 Flaming/Brown micropipette puller, Sutter Instruments, Novato, CA, USA) were filled with low chloride internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes (5-10 MΩ were pulled from borosilicate glass (1.5 mm, outer diameter) on a Flaming/Brown micropipette puller (Sutter Instruments). The series resistance (<20 MΩ ...
-
bioRxiv - Cell Biology 2020Quote: ... Glass micropipettes of inner diameter of ~5 μm were fabricated by pulling borosilicate glass pipette (BF100-50-10; Sutter Instrument) using a micropipette puller (Sutter Instrument) ...
-
bioRxiv - Biophysics 2020Quote: ... The pipettes with bubble number (BN)49 3.5-5.0 were made from the Kimble Chase 2502 soda lime glass using a Sutter P-86 puller (Sutter Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (resistance 5-10 MΩ, pulled on a P-87 Flaming/Brown micropipette puller, Sutter Instruments, Novato, CA, USA) were filled with low chloride internal solution containing (in mM) ...
-
bioRxiv - Cancer Biology 2024Quote: ... Recording pipettes were generated from borosilicate glass (Flaming-Brown puller, Sutter Instruments, P-97, tip resistance of 5–10 MΩ) and were filled with pipette solution consisting of 120 mM potassium gluconate ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipette of 5-8 MΩ tip resistance were fabricated from borosilicate glass by using a microelectrode puller (Sutter Instruments). The initial access resistance was 18.2±0.5 MΩ for current-clamp recordings (n=21 ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes were pulled from borosilicate glass (Flaming-Brown puller, Sutter Instruments, P-97, tip resistance of 5–10 MΩ) and filled with pipette solution consisting of 120 mM potassium gluconate ...
-
bioRxiv - Neuroscience 2022Quote: ... Borosilicate glass recording pipettes (∼2 MΩ tip resistance) were prepared using an electrode puller (P-1000, Sutter Instruments) and filled with filtered ACSF solution with 10 mM HEPES buffer added ...
-
bioRxiv - Neuroscience 2023Quote: ... Experiments were performed using a resonant-galvo 2-photon microscope similar to the Janelia MIMMs design (Sutter Instruments) and a water immersion 16x objective (0.8 NA ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes were made from borosilicate glass with a Flaming-Brown puller (P-97, Sutter Instruments; tip resistance 5-10 MΩ). The pipette solution contained (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch-pipettes (5–13 MΩ) were made from borosilicate glass capillary with a Flaming-Brown puller (P-1000 or P-97; Sutter Instrument) and polished with a microforge ...
-
bioRxiv - Neuroscience 2020Quote: ... Only virus transduced mice identified by their fluorescence upon excitation with a 572 nm LED (Cairn Research) were recorded using patch pipettes of 5–10 MΩ (P-97 Flaming/Brown puller, Sutter Instruments) containing intracellular solution (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Up to ~1.2 μL of viral solution per brain hemisphere were injected at cortical depths of 400 – 500 μm with a glass micropipette (Blaubrand IntraMARK 5 μl) pulled to about 10 – 20 μm inner diameter at the tips using a horizontal puller (Sutter Instruments). Usually 2–3 sites per hemisphere in S1 cortex were injected to increase the transduced brain area ...
-
bioRxiv - Neuroscience 2023Quote: ... in the supra-pyramidal blade of the dentate gyrus was recorded with a borosilicate glass pipette taper-pulled to an impedance of 5-7 MOhm (Sutter Instruments) and filled with the ACSF solution ...
-
bioRxiv - Neuroscience 2023Quote: ... was connected to the ground/reference electrode and slowly implanted into motor cortex using stereotactic procedures at a rate ∼5-10 µm/s under remote micromanipulator control (QUAD, Sutter Instruments) and visualised through a microscope (GT Vision) ...
-
bioRxiv - Neuroscience 2020Quote: ... ≈ 2 µm tip diameter) were pulled from thick-walled Borosilicate glass using a P1000 horizontal micropipette puller (Sutter Instruments, Novato ...
-
bioRxiv - Neuroscience 2023Quote: ... we pulled borosilicate patch pipettes (2–7 MΩ) using a P-1000 puller (Sutter Instruments, Novato, CA, United States) and filled pipettes with an internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2019Quote: ... Pipettes (5-7 MΩ) were pulled from borosilicate glass tubing (outer diameter 1.5 mm, inner diameter 0.86 mm; Sutter Instruments, Novato, CA, USA) and filled with a solution containing (in mM) ...
-
bioRxiv - Physiology 2021Quote: ... Low resistance electrodes (5-10 megaohms) were fashioned from cleaned capillaries using the P-87 Faming/Brown micropipette puller (Sutter Instrument Co.). The electrodes were silanized with dichlorodimethylsilane (440272-100ml ...
-
bioRxiv - Cancer Biology 2021Quote: ... non-filamented borosilicate micropipettes were pulled to a resistance of 5-10 MΩ (P-97 micropipette puller, Sutter Instruments, Novato, CA, USA) and coated with a hydrophobic layer of N,N-dimethyltrimethylsilylamine (Sigma Aldrich ...
-
bioRxiv - Neuroscience 2023Quote: ... CSF was sampled from cisterna magna at 5⍰min intervals with a glass capillary (30–0067, Harvard Apparatus pulled by a Brown Micropipette puller, Model P-97, Sutter Instruments) placed at a 5° angle (7.5⍰mm distal to the occipital bone and 1.5⍰mm lateral to the muscle-midline) ...
-
bioRxiv - Neuroscience 2022Quote: ... The fluorophore (10 μM in HEPES-buffered E3) was loaded into a glass pipette (tip diameter: ~5 μm; Model P-97 Flaming/Brown Micropipette Puller, Sutter Instrument Co.) aimed ~20 μm away at the cupula ...
-
bioRxiv - Molecular Biology 2023Quote: ... 20 cm length) with a 5 to 8 μm tip opening generated using a laser puller (Sutter Instrument Co, model P-2000). Samples were loaded onto the LC using an autosampler at 800 nl/min and eluted at 400 nl/min over a 90-minute gradient with solvent composition rising from 2% to 35% acetonitrile with 0.1% formic acid ...