Labshake search
Citations for Sutter Instruments :
301 - 334 of 334 citations for 6 hydroxy 4 6 dihydrofuro 3 2 c pyran 2 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... Pipettes pulled from borosilicate glass capillary tubes (cat. no. G85150T-4, Warner Instruments) using a P-97 pipette puller (Sutter Instrument) were filled with the following intracellular solution (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... in callosal PV terminals was performed using ∼4-5mW flashes of light generated by a Lambda DG-4 high-speed optical switch with a 300W Xenon lamp (Sutter Instruments), and an excitation filter set centered around 470 nm ...
-
bioRxiv - Neuroscience 2022Quote: ... Illumination and wavelength switching was provided by a Lambda DG-4 high speed filter changer (Sutter Instrument Company, Novato, California, USA). The four wavelengths were chosen as two specific pairs (494 nm ± 31 FWHM and 560 nm ± 16 FWHM ...
-
bioRxiv - Neuroscience 2022Quote: ... a custom-made 32-channel silicon probe was gradually inserted into vermis lobule 4/5 using a single-axis manipulator (SOLO, Sutter instrument). After confirming PC activities by complex spikes ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell current-and voltage-clamp recordings were performed in a recording chamber at room temperature using pulled borosilicate glass pipettes (4-7 MΩ resistance, Sutter Instrument) filled with internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... product HS-532B) about 1 cm away from the ends of 3-barrel borosilicate glass capillary tubes (Sutter Instrument, product FG-G3BF100-75-10) and shrinking it with an infrared lamp ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell patch-clamp recordings were performed using glass pipette electrodes (resistance 3–7 MΩ) pulled from borosilicate capillaries (BF150-86-10, Sutter Instruments, Novato, CA, USA) using a P-97 pipette puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2021Quote: Borosilicate capillary tubes (OD: 1.50mm, ID: 0.86mm, Warner Instruments) were pulled using a horizontal puller (Sutter instruments P-97, resistance of 3-5 MOhm) and filled with artificial Cerebral Spinal Fluid (NaCl ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch electrodes with a resistance of 3-5MΩ were guided to neurons with an MPC-200-ROE controller and MP285 mechanical manipulator (Sutter Instruments, Novato, CA, USA). Patch-clamp recordings were collected through a UPC-10 USB dual digital amplifier and Patchmaster NEXT recording software (HEKA Elektronik GmbH ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell electrophysiological recordings were conducted using borosilicate glass electrodes having an internal resistance of 3-5 MΩ (Sutter Instrument Company, Novato, California, USA). The electrode solution contained (in mM) ...
-
bioRxiv - Cell Biology 2023Quote: ... and emission light was separated using interference (530/50 nm, 590/20-nm) or longpass (650LP) filters (Semrock) mounted in a filter wheel (Sutter instruments Lambda 10-3). An electronic shutter was used to block light exposure between image captures ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes (3-5 MΩ) were guided to neurons with an MPC-200-ROE controller and MP285 mechanical manipulator (Sutter Instruments, Novato, CA USA). Neurons were held at VHold = -70 mV for sEPSC recordings ...
-
bioRxiv - Neuroscience 2020Quote: ... whole-cell patch-clamp recordings were obtained at the soma under 60x magnification in BGMT neurons from control and 6-OHDA-lesioned mice with glass pipettes (at resistances 4-8 MΩ) pulled from 1.5 mm OD borosilicate glass on a Sutter P-97 puller (Sutter Instruments, Novato, CA).
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes (4-7 MΩ; GC150F-10; Harvard Instruments, USA) pulled using a Flaming/brown micropipette puller (Model P-1000; Sutter Instruments, USA). For current clamp recordings ...
-
bioRxiv - Physiology 2022Quote: ... Cells were excited every 1 second with alternating 340-nm and 380-nm light beams (20 millisecond exposure time) originating from a Lambda DG-4 wavelength switcher (Sutter Instrument Company). Light intensity was reduced by 50% before hitting the cells using an appropriate filter ...
-
bioRxiv - Physiology 2020Quote: ... Ratiometric Fura-2AM imaging was performed by in a Nikon Ti-S Inverted Microscope alternatively illuminated with 340 and 380 nm light for 250 ms (Lambda DG-4; Sutter Instrument Co.), using a 20X objective ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch electrodes (resistance of 4-7 MΩ) were pulled on a P-87 or P-1000 pipette puller (Sutter Instruments Co., USA). Pyramidal neurons and PV+ interneurons from L2/3 of the somatosensory or motor cortex were recorded with the whole-cell patch clamp configuration in voltage or current-clamp mode ...
-
bioRxiv - Biophysics 2023Quote: ... Calcium imaging was performed on a Zeiss Axio Observer.Z1 inverted microscope equipped with a Lambda DG-4 (Sutter Instrument Company, Novato, CA) wavelength switcher ...
-
bioRxiv - Physiology 2024Quote: ... USA) was delivered by a liquid light guide from a 150 W xenon arc lamp (DG-4, Sutter Instruments, Novato, CA, USA). Fluorescence emission was high pass-filtered at 510 nm and captured with a cooled digital CCD camera (Photometrics Delta ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes (5-8 MΩ) were stretched from borosilicate glass capillaries (G150TF-3, Warner instruments) using a pipette puller (Sutter Instruments, P-87, Novato, CA) and filled with a few microliters of an intracellular solution adjusted to pH 7.2 ...
-
bioRxiv - Neuroscience 2021Quote: ... by measuring the 510 nm emission following whole-field epi-illumination at both 340 nm and 380 nm excitation wavelengths from a Lambda DG-4 light source (Sutter Instrument; Novato, CA). Data were acquired through a 40x objective as 696 × 520 pixel ...
-
bioRxiv - Neuroscience 2021Quote: ... the right somatosensory cortex was illuminated using 4 different wavelengths of light appropriate to the absorption profiles of the differing haemoglobin states (495nm ± 31, 559nm ± 16, 575nm ± 14 & 587nm ± 9) using a Lambda DG-4 high-speed galvanometer (Sutter Instrument Company, US). A Dalsa 1M60 CCD camera was used to capture the re-emitted light from the cortical surface ...
-
bioRxiv - Neuroscience 2021Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ~4 MΩ resistance pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument, Novato, CA). Electrophysiology data was acquired using a Multiclamp 700B amplifier (Axon Instruments) ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell patch-clamp electrodes with a resistance of 4-7 MΩ were pulled from thick-wall borosilicate glass using a P-97 horizontal puller (Sutter Instrument Co., USA). They were filled with a solution containing (in mM) ...
-
bioRxiv - Neuroscience 2019Quote: ... the right somatosensory cortex was illuminated using 4 different wavelengths of light appropriate to the absorption profiles of the differing haemoglobin states (495nm ± 31, 559nm ± 16, 575nm ± 14 & 587nm ± 9) using a Lambda DG-4 high-speed galvanometer (Sutter Instrument Company, US). A Dalsa 1M60 CCD camera with a frame rate of 32Hz operating in a 4×4 binning mode acquired images at 184×184 pixels ...
-
bioRxiv - Physiology 2019Quote: ... [Ca2+]i was measured in 15-20 individual cells using alternative excitation of Fura2-AM (0.5 Hz) at 340 and 380 nm using a Lambda DG-4 Ultra High Speed Wavelength Switcher (Sutter Instrument, Novato, CA, USA). Images were acquired with a Zeiss Axiocam camera coupled to a 510-nm emission filter and analyzed with Axiovision software ...
-
bioRxiv - Neuroscience 2020Quote: ... the right somatosensory cortex was illuminated using 4 different wavelengths of light appropriate to the absorption profiles of the differing haemoglobin states (495nm ± 31, 559nm ± 16, 575nm ± 14 & 587nm ± 9) using a Lambda DG-4 high-speed galvanometer (Sutter Instrument Company, US). A Dalsa 1M60 CCD camera was used to capture the re-emitted light from the cortical surface ...
-
A transcriptomic atlas of the mouse cerebellum reveals regional specializations and novel cell typesbioRxiv - Genomics 2020Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼4 MΩ resistance pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument, Novato, CA). Electrophysiology data was acquired using a Multiclamp 700B amplifier (Axon Instruments) ...
-
bioRxiv - Biophysics 2022Quote: ... Calcium imaging was performed 24 h after transfection on a Zeiss Axio Observer.Z1 inverted microscope equipped with a Lambda DG-4 (Sutter Instrument Company, Novato, CA) wavelength switcher ...
-
bioRxiv - Neuroscience 2021Quote: ... using glass pipette (4-8 MΩ) pulled from thick-walled borosilicate glass capillaries with a micropipette puller (Model P-97; Sutter Instrument, Novato, CA, USA) as before (Dabrowska et al. ...
-
bioRxiv - Microbiology 2021Quote: ... The micropipettes used for microinjection were prepared from thin wall glass capillary (TW100F-4 with length 100 mm and diameter 1mm) using a Flaming/Brown Micropipette Puller (Sutter Instruments model P-87) set at pressure 360 ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording electrodes were pulled from borosilicate glass (4-8 MΩ tip resistance) using a P-97 Flaming/Brown micropipette puller (Sutter Instrument Co., Novato, CA) and filled with intracellular patch electrode solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... slices from were exposed to wide-field blue (λ=470nm) or amber (λ=589nm, 10 =589nm, mW/mm2) illumination using Lambda DG-4 Plus (Sutter Instruments, Novato, CA) or Thorlabs 4-Wavelength High-Power LED Sources (Thorlabs ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell voltage- and current-clamp recordings were obtained from mouse DRG neurons or transiently transfected HEK293 cells with borosilicate glass patch-pipettes (Sutter Instruments, 4-8 MΩ resistance) and were performed simultaneously with temperature recordings ...