bioRxiv - Biochemistry 2019Quote: ... 75 µm-inner diameter fused silica analytical column with an integrated spray tip (6-8 µm diameter opening, pulled on a P-2000 laser puller from Sutter Instruments). The trap column is packed with 5 µm Aqua C-18 beads (Phenomenex ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... 75-μm-inner diameter fused silica analytical column with an integrated spray tip (6-8-μm-diameter opening, pulled on a P-2000 laser puller, Sutter Instruments). The trap column is packed with 5 μm Aqua C18 beads (Phenomenex ...
-
bioRxiv - Neuroscience 2023Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼1-3-MΩ resistance for PCs and ∼3-6-MΩ resistance for MLIs pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument). Slice recordings with PC leak currents greater than 500 pA were rejected ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes (Hilgenberg) of 6 - 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter Instruments). The intracellular solution contained 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2023Quote: ... We filled patch pipettes (2-4 MΩ) pulled (P-97, Sutter Instrument) from borosilicate capillary glass (Sutter Instrument ...
-
bioRxiv - Neuroscience 2021Quote: ... POMC neurons in the arcuate nucleus were visually identified by GFP expression and subjected to whole cell patch clamp using 3-6 MΩ borosilicate glass micropipettes (Sutter Instruments, UK) filled with potassium gluconate internal containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... Cells were patched with BF150-75-10 glass pipettes (∼ 6 MΩ) pulled with a Flaming Brown Micropipette Puller (Model P-97, Sutter Instruments, US). Pipettes were mounted on a MP-225 micromanipulator and filled with an intracellular solution containing 120mM K-gluconate ...
-
bioRxiv - Neuroscience 2019Quote: ... Thin-walled borosilicate glass capillary recording electrodes (3–6 MΩ) were pulled on a Flaming-Brown micropipette puller (Sutter Instruments, Novato, CA).
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were then conducted at RT using pipettes with resistances typically ranging from 6-8 MΩ (P-2000, Sutter Instruments, USA). The pipette solution consisted of the following concentrations (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... to a resistance of 2-4 MΩ with a puller (P97, Sutter Instruments) and filled with double-filtered (0.22 μm ...
-
bioRxiv - Neuroscience 2019Quote: ... Whole-cell current clamp recordings of these neurons in coronal visual cortex slices of P50 to P80 wild-type mice were performed using borosilicate glass pipettes (3-6 MOhms, Sutter Instrument, Novato, CA) filled with an internal solution (in mM) ...
-
bioRxiv - Physiology 2021Quote: ... Borosilicate patch pipettes were pulled and polished to resistance of 3-6 MΩ for all experiments using a micropipette puller (model P-97, Sutter Instruments, Novato, CA). Freshly dissociated arterial myocytes were kept in ice-cold Mg2+-PSS before being recorded.
-
bioRxiv - Physiology 2023Quote: ... Borosilicate patch pipettes were pulled and polished to resistances of 3-6 MΩ using a micropipette puller (model P-97, Sutter Instruments, Novato, CA).
-
bioRxiv - Physiology 2024Quote: ... Borosilicate patch pipettes were pulled and polished to resistances of 3-6 MΩ for all experiments using a micropipette puller (model P-97, Sutter Instruments, Novato, CA).
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes (2–4 MΩ) pulled from borosilicate glass (BF150-86-7.5, Sutter Instruments) were filled with a Cs+-based internal solution containing (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... to a resistance of 2–4 MΩ using a horizontal puller (Sutter Instrument P97). The internal recording solution contained in (mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (2–4 MΩ) pulled from borosilicate glass (BF150-86-7.5, Sutter Instruments) were filled with a Cs+-based internal solution containing (in mM) ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... Patch pipettes were pulled to a tip resistance of 6-8 MΩ using borosilicate glass capillary tubes with a P-1000 micropipette puller (Sutter Instrument, Novato, CA, USA). Current clamp recording was performed using a Multiclamp 700B amplifier (Axon Instruments ...
-
bioRxiv - Neuroscience 2022Quote: Recording electrodes (2-4 MΩ) were pulled on a P-97 Micropipette Puller (Sutter Instruments). All recordings were conducted with potassium-gluconate intercellular recording solution [in mM ...
-
bioRxiv - Biophysics 2022Quote: ... Patch pipettes with a resistance of 2 – 4 MΩ were fabricated from borosilicate glass (Sutter instrument) and fire polished ...
-
bioRxiv - Biophysics 2022Quote: ... Patch pipettes with a resistance of 2 – 4 MΩ were fabricated from borosilicate glass (Sutter instrument). Solution exchange was achieved with a fast-step perfusion system (Warner instrument ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch electrodes (2–4 MΩ) were pulled from borosilicate capillary glass of external diameter 1 mm (Sutter Instruments) using a Flaming/Brown micropipette puller (model P-2000 ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Patch pipettes (2-4 MΩ) made from pulled (Model P-97 Flaming-Brown Micropipette Puller, Sutter Instruments, Novato, CA) and fire-polished borosilicate glass capillaries (World Precision Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes (2–4 MΩ) were pulled from thin-walled borosilicate glass capillaries using a P95 pipette puller (Sutter Instruments). Signals were acquired using an Axon Multiclamp 700B amplifier (Molecular Devices) ...
-
bioRxiv - Neuroscience 2023Quote: ... to a resistance of 2–4 MΩ using a horizontal puller (P-97 or P-1000; Sutter Instruments, Novato, CA). In most experiments ...
-
bioRxiv - Neuroscience 2022Quote: ... Micropipettes (2-4 MΩ) were pulled from borosilicate capillaries (Science Products GmbH) with a P-97 Flaming/Brown Micropipette Puller (Sutter Instruments). The cell capacitance and series resistance were always compensated (up to 75%).
-
bioRxiv - Bioengineering 2021Quote: Borosilicate glass pipettes were pulled to a resistance of 2-4 MΩ using a flaming/brown micropipette puller (Model P-1000; Sutter Instrument, Novato, CA). The pipettes were filled with intracellular solution containing 10 mM NaCl ...
-
bioRxiv - Neuroscience 2020Quote: Micropipettes for patch clamp experiments (2-4 MΩ) were made from pulled (Model P-97 Flaming-Brown Micropipette Puller, Sutter Instruments, Novato, CA) and fire-polished 1.5/0.84 o.d./i.d ...
-
bioRxiv - Physiology 2022Quote: ... Borosilicate glass pipettes were pulled to a resistance of 2-4 MΩ using a flaming/brown micropipette puller (Model P-1000; Sutter Instrument, Novato, CA). Pipette tips were first dipped into intracellular solution containing 10mM NaCl ...
-
bioRxiv - Neuroscience 2022Quote: Whole cell patch clamp recordings were made at room temperature (20-24°C) using patch pipettes with a tip resistance of 2-4 MΩ that were pulled (Flaming-Brown puller, Sutter Instruments, Novato, CA, USA) from borosilicate glass capillaries (BF150-86-10 ...
-
bioRxiv - Neuroscience 2023Quote: Labeled vagal neurons were approached by glass pipettes (2–4 MΩ resistance) using a micromanipulator (MP-285/ MPC-200, Sutter Instruments, Novato, CA, USA) attached to a head stage (CV203BU ...
-
bioRxiv - Neuroscience 2022Quote: ... The recordings were obtained using borosilicate glass pipettes (resistance 4–10 MΩ) prepared using a 2-stage vertical pipette puller (P-1000, Sutter Instrument, or PP-83, Narishige). The pipettes were filled with a solution containing the following (in mM) ...
-
bioRxiv - Cell Biology 2019Quote: ... Lambda DG-4 lamp (Sutter Instruments), filter sets 49002 ET GFP(Chroma) ...
-
bioRxiv - Neuroscience 2020Quote: ... and a DG-4 illumination system (Sutter Instrument) equipped with a Xenon lamp for rapid wavelength switching ...
-
bioRxiv - Neuroscience 2019Quote: ... 4 mW/mm2) generated by a Lambda DG-4 high-speed optical switch with a 300 W Xenon lamp (Sutter Instruments) and an excitation filter centered around 470 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass pipettes with a tip resistance of 3–4 MΩ (G150F-4, Warner Instruments) were pulled on a P-97 Flaming-Brown micropipette puller (Sutter Instruments) and filled with an internal solution containing ...
-
bioRxiv - Neuroscience 2021Quote: ... 4□mW/mm2) generated by a Lambda DG-4 high-speed optical switch with a 300□W Xenon lamp (Sutter Instruments) and an excitation filter centered around 470□nm ...
-
bioRxiv - Neuroscience 2019Quote: Borosilicate pipettes (2.8 – 4 MΩ; Sutter Instruments, Novato, CA) were filled with potassium gluconate-based internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Chroma) and shutter of a λDG-4 (Sutter Instruments). Epifluorescence (495 nm long pass and emission 500 –520 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... Excitation light was from a Lambda DG-4 (Sutter Instruments) and it was passed through an excitation filter (AmCyan,Chroma) ...
-
bioRxiv - Neuroscience 2020Quote: ... A switching galvanometer system (Lambda DG-4 Sutter Instruments Company) with 4 wavelength filters (λ — 495 ± 31 ...
-
bioRxiv - Neuroscience 2022Quote: ... A Lambda DG-4 (Sutter Instrument Company, Novato CA, USA) white light source was used to illuminate the samples through a GFP excitation/emission filter set ...
-
bioRxiv - Neuroscience 2022Quote: ... using a Lambda DG-4 fast beam switcher (Sutter Instruments) with a xenon lamp and ET470/40nm band pass filter ...
-
bioRxiv - Neuroscience 2021Quote: ... using pulled borosilicate glass pipettes (4-7 MΩ resistance, Sutter Instrument) filled with an internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... on a 4-step micropipette P-90puller (Sutter Instruments, Novato, CA). The internal solution contained the following (in mM) ...
-
bioRxiv - Physiology 2019Quote: ... A 4-step pulling protocol using a horizontal puller (P97, Sutter Instruments) was optimized to obtain a short shaft (∼8 mm ...
-
bioRxiv - Neuroscience 2022Quote: ... CFP and YFP were detected using Lambda DG-4 monochromator (Sutter Instruments) coupled to the microscope through an optic fiber with appropriate filters (excitation ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (4-7 MΩ) were created from borosilicate glass capillaries (Sutter Instrument) using a P-97 puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipette (4-7 MOhm) were pulled from borosilicate glass filaments (Sutter Instruments) and filled with K-gluconate solution (in mM ...
-
bioRxiv - Neuroscience 2022Quote: ... using a Lambda DG-4 high-speed filter changer (Sutter Instrument Company, USA), the cortex under the thinned window was illuminated with four wavelengths of light (587±9nm ...