Labshake search
Citations for Sutter Instruments :
51 - 100 of 221 citations for 6 Chloro 2 trifluoromethyl 4 pyrimidinamine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2019Quote: ... 4 mW/mm2) generated by a Lambda DG-4 high-speed optical switch with a 300 W Xenon lamp (Sutter Instruments) and an excitation filter centered around 470 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass pipettes with a tip resistance of 3–4 MΩ (G150F-4, Warner Instruments) were pulled on a P-97 Flaming-Brown micropipette puller (Sutter Instruments) and filled with an internal solution containing ...
-
bioRxiv - Neuroscience 2021Quote: ... 4□mW/mm2) generated by a Lambda DG-4 high-speed optical switch with a 300□W Xenon lamp (Sutter Instruments) and an excitation filter centered around 470□nm ...
-
bioRxiv - Neuroscience 2021Quote: ... Pipettes were pulled from thin-walled borosilicate capillaries without filament (3-6 MΩ) (Sutter Instruments), and filled with internal solution containing (in mM ...
-
bioRxiv - Bioengineering 2022Quote: ... Recording pipettes (3–6 MΩ) were pulled with a micropipette puller (P1000, Sutter Instrument; USA). For whole-cell recordings ...
-
bioRxiv - Neuroscience 2023Quote: ... We fire-polished borosilicate glass patch-clamp pipettes with 6-12 MΩ resistance (Sutter Instruments). The internal patch solution had a pH of 7.25 ...
-
bioRxiv - Neuroscience 2023Quote: ... The pipette (6-8 MΩ) was pulled by a micropipette puller (P-1000, Sutter instrument) and filled with the internal solution that contained (in mM) ...
-
bioRxiv - Neuroscience 2019Quote: Borosilicate pipettes (2.8 – 4 MΩ; Sutter Instruments, Novato, CA) were filled with potassium gluconate-based internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Chroma) and shutter of a λDG-4 (Sutter Instruments). Epifluorescence (495 nm long pass and emission 500 –520 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes were made of thick wall borosilicate glass capillaries (Sutter instruments, 3-6 MΩ resistance) using a horizontal pipette puller (P-97 ...
-
bioRxiv - Neuroscience 2019Quote: ... Whole-cell recordings from cartwheel cells were performed using glass micropipettes (3-6 MΩ; Sutter Instruments). Cartwheel cells were identified by the presence of complex spikes in cell-attached configuration before break-in or in response to current injections in current-clamp mode after break-in (Zhang & Oertel ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Glass patching pipettes (3–6 MΩ resistance) were prepared using a P-1000 puller (Sutter Instruments) and filled with intracellular solution (ICS ...
-
bioRxiv - Physiology 2024Quote: ... Patch electrodes (3-6 MΩ) were pulled from borosilicate capillaries (BF-150-110-10, Sutter Instrument). The external solution for both EC cell and 5-HT3 channel recordings was Ringer’s solution ...
-
bioRxiv - Neuroscience 2021Quote: ... Excitation light was from a Lambda DG-4 (Sutter Instruments) and it was passed through an excitation filter (AmCyan,Chroma) ...
-
bioRxiv - Neuroscience 2020Quote: ... A switching galvanometer system (Lambda DG-4 Sutter Instruments Company) with 4 wavelength filters (λ — 495 ± 31 ...
-
bioRxiv - Neuroscience 2022Quote: ... A Lambda DG-4 (Sutter Instrument Company, Novato CA, USA) white light source was used to illuminate the samples through a GFP excitation/emission filter set ...
-
bioRxiv - Neuroscience 2022Quote: ... using a Lambda DG-4 fast beam switcher (Sutter Instruments) with a xenon lamp and ET470/40nm band pass filter ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (5-6 MΩ) were pulled from borosilicate glass capillaries (GBF-150-117-10; Sutter Instruments) with a micropipette horizontal puller (P-97 ...
-
bioRxiv - Neuroscience 2024Quote: ... glass recording pipettes (3–6 MΩ) were prepared using a P-87 glass pipette puller (Sutter Instrument). The pipettes for whole-cell recordings were filled with an internal solution composed of (in mM) ...
-
bioRxiv - Cell Biology 2024Quote: ... Fire-polished thick-walled Borosilicate glass pipettes (3-6 MΩ, BF150-86-10, Sutter Instruments, Novato, CA) were pulled using a P-1000 Flaming/Brown (Sutter instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... using pulled borosilicate glass pipettes (4-7 MΩ resistance, Sutter Instrument) filled with an internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... on a 4-step micropipette P-90puller (Sutter Instruments, Novato, CA). The internal solution contained the following (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... with resistances ranging 3–6 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). The recording chamber was perfused with carbogenated aCSF at 2 ml/min and maintained at ~26–32 °C ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes (3-6 MΩ) were pulled from borosilicate glass using a horizontal pipette puller (P1000, Sutter Instruments). Electrical signals were acquired using a Multiclamp 700B amplifier and PClamp 10 data acquisition software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes with resistance ranging from 6 to 10 MΩ were fabricated from borosilicate glass (Sutter Instruments, Novato, CA) on a 4-step micropipette P-90puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (3–6 MΩ) were manufactured from filamented borosilicate glass capillaries (Sutter Instruments, Novato, CA, BF100-58-10) and filled with an intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... with a long taper (more than 6 mm) were pulled with a pipette puller (Sutter Instruments, model P-97) for TG injection ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (6–7 MΩ tip resistance, borosilicate glass, outer diameter 1.5 mm, inner diameter 0.86 mm, Sutter Instruments) were filled with the following internal solution (in mM) ...
-
bioRxiv - Physiology 2019Quote: ... A 4-step pulling protocol using a horizontal puller (P97, Sutter Instruments) was optimized to obtain a short shaft (∼8 mm ...
-
bioRxiv - Neuroscience 2022Quote: ... CFP and YFP were detected using Lambda DG-4 monochromator (Sutter Instruments) coupled to the microscope through an optic fiber with appropriate filters (excitation ...
-
bioRxiv - Neuroscience 2020Quote: ... The patch pipettes were pulled to yield an impedance of 6–8 MΩ on a horizontal pipette puller (Sutter Instrument) from thin-walled ...
-
bioRxiv - Neuroscience 2023Quote: Pipettes with resistance of 3.5-6 MΩ were fabricated from borosilicate filamented capillaries using the P-97 micropipette puller (Sutter Instrument). The pipettes were filled with an internal solution composed of 8mM NaCl ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (4-7 MΩ) were created from borosilicate glass capillaries (Sutter Instrument) using a P-97 puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipette (4-7 MOhm) were pulled from borosilicate glass filaments (Sutter Instruments) and filled with K-gluconate solution (in mM ...
-
bioRxiv - Neuroscience 2022Quote: ... using a Lambda DG-4 high-speed filter changer (Sutter Instrument Company, USA), the cortex under the thinned window was illuminated with four wavelengths of light (587±9nm ...
-
bioRxiv - Neuroscience 2023Quote: ... Fire polished borosilicate pipettes with 3-4 MOhm resistance (Sutter Instruments, Novato, CA) were filled with either Cs-gluconate or K-gluconate internal solutions ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (4-7 MΩ) were pulled from borosilicate glass filaments (Sutter Instruments) and filled with a Cesium (Cs2+)-based internal solution (in mM ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Low resistance borosilicate glass pipettes (2-3 MΩ; Sutter Instruments) were filled with a solution containing (in mM) ...
-
bioRxiv - Microbiology 2022Quote: ... 40 cm long fused silica analytical column with an integrated spray tip (6 – 8 μm-diameter opening, pulled on a P-2000 laser puller from Sutter Instruments). The analytical column was packed with 1.9 μm-diameter Reprosil-Pur C-18-AQ beads (Dr ...
-
bioRxiv - Systems Biology 2019Quote: ... 75 μm inner diameter fused silica analytical column with an integrated spray tip (6-8 μm diameter opening, pulled on a P-2000 laser puller from Sutter Instruments). The trap column was packed with 5 μm Aqua C-18 beads (Phenomenex ...
-
bioRxiv - Biochemistry 2019Quote: ... 75 µm-inner diameter fused silica analytical column with an integrated spray tip (6-8 µm diameter opening, pulled on a P-2000 laser puller from Sutter Instruments). The trap column is packed with 5 µm Aqua C-18 beads (Phenomenex ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... 75-μm-inner diameter fused silica analytical column with an integrated spray tip (6-8-μm-diameter opening, pulled on a P-2000 laser puller, Sutter Instruments). The trap column is packed with 5 μm Aqua C18 beads (Phenomenex ...
-
bioRxiv - Neuroscience 2023Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼1-3-MΩ resistance for PCs and ∼3-6-MΩ resistance for MLIs pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument). Slice recordings with PC leak currents greater than 500 pA were rejected ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes (Hilgenberg) of 6 - 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter Instruments). The intracellular solution contained 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipette (4-7 MOhm) were pulled from borosilicate glass filaments (Sutter Instrument Co.) and filled with potassium (K)-gluconate solution (GCamp7s characterization ...
-
bioRxiv - Neuroscience 2019Quote: Experimentation and shutter control was automated (Lambda DG-4/Lambda 10-B, Sutter Instruments) and two application protocols were used ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (4 – 7 MΩ) pulled from borosilicate glass (Sutter instrument, BF150-86-10) were filled with a K-gluconate based internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... with 4-7 MΩ borosilicate pipettes (2.0 mm OD, 1.16 mm ID, Sutter Instruments) filled with a standard low-chloride internal solution (120 mM potassium gluconate ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (4-7 MOhm) were pulled from borosilicate glass filaments (Sutter Instrument Co.) and filled with Cesium (Cs2+)-based internal solution (in mM ...
-
bioRxiv - Biophysics 2024Quote: ... Cells expressing TdTomato were identified using a DG-4 light excitation system (Sutter instruments). Voltage-clamp recordings were obtained using borosilicate glass pipettes with 4-6MΩ resistance filled with the following intracellular solution (in mM) ...