Labshake search
Citations for Sutter Instruments :
51 - 100 of 165 citations for 5 Isobutyl thiophene 2 carbaldehyde since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... Recording electrodes (3-5 MOhm) were pulled with a Flaming-Brown Micropipette Puller (Sutter Instruments, Novato, CA) using thin-walled borosilicate glass capillaries ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes were pulled to tip resistances of 5-8 MΩ using a multistage puller (Sutter Instruments) and were filled with intracellular solution ...
-
bioRxiv - Biophysics 2021Quote: ... were pulled to ∼2-6 MΩ resistance with a micropipette puller (Sutter Instruments; P-97) and polished with a microforge (Narishige ...
-
bioRxiv - Cell Biology 2020Quote: ... These filters were alternated by a filter-changer Lambda 10–2(Sutter Instruments, Novato, CA). Exposure time was 50–500 ms ...
-
bioRxiv - Neuroscience 2022Quote: Recording electrodes (2-4 MΩ) were pulled on a P-97 Micropipette Puller (Sutter Instruments). All recordings were conducted with potassium-gluconate intercellular recording solution [in mM ...
-
bioRxiv - Immunology 2023Quote: ... The fluorescence lamp of setup #2 was equipped with one filter wheel (Sutter Instrument Company) with the following filters installed ...
-
bioRxiv - Immunology 2023Quote: ... and setup #2 was coupled to a xenon lamp (Lambda LS lamp, Sutter Instrument Company). Fluorescence lamp illumination was realized by using various sets of filters in the excitation path ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes (3 - 5 MΩ) were pulled using a Brown/Flaming P-97 micro pipette puller (Sutter Instruments). Slices were perfused with oxygenated recording solution (~2ml/min ...
-
bioRxiv - Biophysics 2021Quote: ... Borosilicate glass patch pipettes of 3-5 MΩ were formed using a micropipette puller (Sutter Instruments, P-97) and then coated with Sylgard 184 silicone (Dow Corning) ...
-
bioRxiv - Neuroscience 2020Quote: ... Imaging of dorsal DG was performed with a 2-photon laser scanning microscope (MOM, Sutter Instruments) using a 1070 nm femtosecond-pulsed laser (Fidelity 2 ...
-
bioRxiv - Biophysics 2022Quote: ... Patch pipettes with a resistance of 2 – 4 MΩ were fabricated from borosilicate glass (Sutter instrument) and fire polished ...
-
bioRxiv - Biophysics 2019Quote: ... pulled to a resistance of 2 MΩ - 6 MΩ (P-1000, Sutter Instrument, Novato, CA USA) and filled with an internal solution containing (in mM) ...
-
bioRxiv - Biophysics 2022Quote: ... Patch pipettes with a resistance of 2 – 4 MΩ were fabricated from borosilicate glass (Sutter instrument). Solution exchange was achieved with a fast-step perfusion system (Warner instrument ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate pipettes of 5 – 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter instruments). All recordings were done in current clamp with an intracellular solution containing 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2020Quote: The STG was desheathed dorsally and neuron somata were impaled using glass microelectrodes (ID: 0.86 mm; OD: 1.5 mm; 5-20 MΩ; Sutter Instrument). Microelectrodes were backfilled with a solution containing 10 mM MgCl2 ...
-
bioRxiv - Neuroscience 2022Quote: ... Data were filtered at 5 kHz and sampled at 10 kHz and stored in a computer (Sutter Instrument Co.). The standard internal pipette solution for whole-cell voltage-clamp contained (in mM ...
-
bioRxiv - Pathology 2023Quote: ... Recording electrodes (3–5 MΩ) were pulled on a model P-87 micropipette puller (Sutter Instruments, Novato, CA, USA) and polished using a MF-830 MicroForge (Narishige Scientific Instruments Laboratories ...
-
bioRxiv - Biophysics 2020Quote: ... Borosilicate and quartz nanopipettes were fabricated with a CO-2 laser puller (Model P-2000, Sutter Instruments) with a radius from 40 nm to 60 nm and 20 nm to 40 nm respectively.
-
bioRxiv - Neuroscience 2020Quote: ... under the control of the Sutter filter wheel shutter controller (Lambda 10-2, Sutter Instrument, Novato, CA). All data were sampled at 3-10 kHz ...
-
bioRxiv - Neuroscience 2022Quote: ... pipette tip diameter: 2 μm) were pulled from borosilicate glass using a P-97 puller (Sutter Instruments) and filled with intracellular solution (containing in mM ...
-
bioRxiv - Cell Biology 2019Quote: ... Glass pipettes with a resistance of 2.5 – 5 MΩ measured with physiological solutions (below) were pulled using an automatic P-97 Micropipette Puller system (Sutter Instruments).
-
bioRxiv - Neuroscience 2019Quote: ... The recording electrode was pulled from a borosilicate glass pipette (3–5 MΩ; #B150-110-10HP, Sutter Instruments, Novato, CA) using an electrode puller (#P-1000 ...
-
bioRxiv - Neuroscience 2020Quote: ... World Precision) to obtain pipette resistance ranging from 5 – 8 MΩ using next generation micropipette puller (P-1000, Sutter Instrument). External solution is consist of 140 mM NaCl ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (resistance 5-10 MΩ, pulled using a P-87 Flaming/Brown micropipette puller, Sutter Instruments, Novato, CA, USA) were filled with low chloride internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes (5-10 MΩ were pulled from borosilicate glass (1.5 mm, outer diameter) on a Flaming/Brown micropipette puller (Sutter Instruments). The series resistance (<20 MΩ ...
-
bioRxiv - Cell Biology 2020Quote: ... Glass micropipettes of inner diameter of ~5 μm were fabricated by pulling borosilicate glass pipette (BF100-50-10; Sutter Instrument) using a micropipette puller (Sutter Instrument) ...
-
bioRxiv - Biophysics 2020Quote: ... The pipettes with bubble number (BN)49 3.5-5.0 were made from the Kimble Chase 2502 soda lime glass using a Sutter P-86 puller (Sutter Instruments).
-
bioRxiv - Neuroscience 2022Quote: ... The patch pipettes with resistance 3-5 MΩ were pulled by the pipette puller (Sutter Instrument Co., Model P-97). To measure spontaneous action potential (sAP) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (resistance 5-10 MΩ, pulled on a P-87 Flaming/Brown micropipette puller, Sutter Instruments, Novato, CA, USA) were filled with low chloride internal solution containing (in mM) ...
-
bioRxiv - Cancer Biology 2024Quote: ... Recording pipettes were generated from borosilicate glass (Flaming-Brown puller, Sutter Instruments, P-97, tip resistance of 5–10 MΩ) and were filled with pipette solution consisting of 120 mM potassium gluconate ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipette of 5-8 MΩ tip resistance were fabricated from borosilicate glass by using a microelectrode puller (Sutter Instruments). The initial access resistance was 18.2±0.5 MΩ for current-clamp recordings (n=21 ...
-
bioRxiv - Neuroscience 2024Quote: ... Pipettes (4-5 MΩ) were pulled from thick-walled borosilicate capillary glass with a puller (model P-1000, Sutter instrument). For a voltage-clamp recording ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass micropipettes with a tip resistance of ∼4-5 MΩ were prepared using a P-1000 puller (Sutter Instruments) and then filled with an intracellular recording solution containing (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes were pulled from borosilicate glass (Flaming-Brown puller, Sutter Instruments, P-97, tip resistance of 5–10 MΩ) and filled with pipette solution consisting of 120 mM potassium gluconate ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch electrodes (2–4 MΩ) were pulled from borosilicate capillary glass of external diameter 1 mm (Sutter Instruments) using a Flaming/Brown micropipette puller (model P-2000 ...
-
bioRxiv - Neuroscience 2022Quote: ... Borosilicate glass recording pipettes (∼2 MΩ tip resistance) were prepared using an electrode puller (P-1000, Sutter Instruments) and filled with filtered ACSF solution with 10 mM HEPES buffer added ...
-
bioRxiv - Neuroscience 2021Quote: Patch electrodes (2–3□MΩ) were pulled from borosilicate capillary glass of external diameter 1□mm (Sutter Instruments) using a Flaming/Brown micropipette puller (model P-2000 ...
-
bioRxiv - Neuroscience 2023Quote: ... Experiments were performed using a resonant-galvo 2-photon microscope similar to the Janelia MIMMs design (Sutter Instruments) and a water immersion 16x objective (0.8 NA ...
-
bioRxiv - Neuroscience 2020Quote: ... All whole-cell experiments were recorded using borosilicate glass pipettes with resistances in the 3 – 5 MΩ range and were pulled on a Flaming-Brown micropipette puller (P-1000, Sutter Instruments). Whole-cell voltage-clamp electrophysiology recordings were made from spiny projection neurons (SPNs ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes were made from borosilicate glass with a Flaming-Brown puller (P-97, Sutter Instruments; tip resistance 5-10 MΩ). The pipette solution contained (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording electrode was pulled from a borosilicate glass pipette (3–5 MΩ) using an electrode puller (P-1000; Sutter Instruments) and filled with a K-gluconate-based internal solution (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell patch clamp recordings were obtained using thin-walled borosilicate glass microelectrodes (Warner) pulled to a tip resistance of 3-5 MΩ pulled using a P-97 Flaming/Brown Micropipette Puller (Sutter Instrument). Electrodes were filled with an intracellular recording solution containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch-pipettes (5–13 MΩ) were made from borosilicate glass capillary with a Flaming-Brown puller (P-1000 or P-97; Sutter Instrument) and polished with a microforge ...
-
bioRxiv - Neuroscience 2020Quote: ... Only virus transduced mice identified by their fluorescence upon excitation with a 572 nm LED (Cairn Research) were recorded using patch pipettes of 5–10 MΩ (P-97 Flaming/Brown puller, Sutter Instruments) containing intracellular solution (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Up to ~1.2 μL of viral solution per brain hemisphere were injected at cortical depths of 400 – 500 μm with a glass micropipette (Blaubrand IntraMARK 5 μl) pulled to about 10 – 20 μm inner diameter at the tips using a horizontal puller (Sutter Instruments). Usually 2–3 sites per hemisphere in S1 cortex were injected to increase the transduced brain area ...
-
bioRxiv - Neuroscience 2023Quote: ... in the supra-pyramidal blade of the dentate gyrus was recorded with a borosilicate glass pipette taper-pulled to an impedance of 5-7 MOhm (Sutter Instruments) and filled with the ACSF solution ...
-
bioRxiv - Neuroscience 2022Quote: ... a custom-made 32-channel silicon probe was gradually inserted into vermis lobule 4/5 using a single-axis manipulator (SOLO, Sutter instrument). After confirming PC activities by complex spikes ...
-
bioRxiv - Neuroscience 2023Quote: ... Single neurons were recorded ‘blind’ by advancing the pipette in 3 – 5 μm steps using a single-axis stepper motor and controller (Solo, Sutter Instruments) or hydraulic micromanipulator (MX610 ...
-
bioRxiv - Neuroscience 2023Quote: ... was connected to the ground/reference electrode and slowly implanted into motor cortex using stereotactic procedures at a rate ∼5-10 µm/s under remote micromanipulator control (QUAD, Sutter Instruments) and visualised through a microscope (GT Vision) ...
-
bioRxiv - Neuroscience 2023Quote: ... was subsequently inserted to a depth of 1.5 mm into the brain (Extended Data Fig. 5a) at a rate of 3-5 μm/s using a motorized micromanipulator (MP-225A, Sutter Instrument). Electrode voltages were acquired at 30 kHz and bandpass filtered at 0.3 to 10 kHz using SpikeGLX (Bill Karsh ...