bioRxiv - Neuroscience 2020Quote: ... Only virus transduced mice identified by their fluorescence upon excitation with a 572 nm LED (Cairn Research) were recorded using patch pipettes of 5–10 MΩ (P-97 Flaming/Brown puller, Sutter Instruments) containing intracellular solution (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Up to ~1.2 μL of viral solution per brain hemisphere were injected at cortical depths of 400 – 500 μm with a glass micropipette (Blaubrand IntraMARK 5 μl) pulled to about 10 – 20 μm inner diameter at the tips using a horizontal puller (Sutter Instruments). Usually 2–3 sites per hemisphere in S1 cortex were injected to increase the transduced brain area ...
-
bioRxiv - Neuroscience 2022Quote: ... 1.5 mm diameter borosilicate pipettes with tip resistances of 2-5 MΩ were pulled using a P-1000 micropipette puller (Sutter Instruments). Pipettes were filled intracellular solution containing (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... in the supra-pyramidal blade of the dentate gyrus was recorded with a borosilicate glass pipette taper-pulled to an impedance of 5-7 MOhm (Sutter Instruments) and filled with the ACSF solution ...
-
bioRxiv - Neuroscience 2023Quote: ... was connected to the ground/reference electrode and slowly implanted into motor cortex using stereotactic procedures at a rate ∼5-10 µm/s under remote micromanipulator control (QUAD, Sutter Instruments) and visualised through a microscope (GT Vision) ...
-
bioRxiv - Microbiology 2021Quote: ... The micropipettes used for microinjection were prepared from thin wall glass capillary (TW100F-4 with length 100 mm and diameter 1mm) using a Flaming/Brown Micropipette Puller (Sutter Instruments model P-87) set at pressure 360 ...
-
bioRxiv - Neuroscience 2022Quote: Whole cell patch clamp recordings were made at room temperature (20-24°C) using patch pipettes with a tip resistance of 2-4 MΩ that were pulled (Flaming-Brown puller, Sutter Instruments, Novato, CA, USA) from borosilicate glass capillaries (BF150-86-10 ...
-
bioRxiv - Neuroscience 2023Quote: Labeled vagal neurons were approached by glass pipettes (2–4 MΩ resistance) using a micromanipulator (MP-285/ MPC-200, Sutter Instruments, Novato, CA, USA) attached to a head stage (CV203BU ...
-
bioRxiv - Neuroscience 2019Quote: ... Pipettes (5-7 MΩ) were pulled from borosilicate glass tubing (outer diameter 1.5 mm, inner diameter 0.86 mm; Sutter Instruments, Novato, CA, USA) and filled with a solution containing (in mM) ...
-
bioRxiv - Physiology 2021Quote: ... Low resistance electrodes (5-10 megaohms) were fashioned from cleaned capillaries using the P-87 Faming/Brown micropipette puller (Sutter Instrument Co.). The electrodes were silanized with dichlorodimethylsilane (440272-100ml ...
-
bioRxiv - Cancer Biology 2021Quote: ... non-filamented borosilicate micropipettes were pulled to a resistance of 5-10 MΩ (P-97 micropipette puller, Sutter Instruments, Novato, CA, USA) and coated with a hydrophobic layer of N,N-dimethyltrimethylsilylamine (Sigma Aldrich ...
-
bioRxiv - Neuroscience 2023Quote: ... CSF was sampled from cisterna magna at 5⍰min intervals with a glass capillary (30–0067, Harvard Apparatus pulled by a Brown Micropipette puller, Model P-97, Sutter Instruments) placed at a 5° angle (7.5⍰mm distal to the occipital bone and 1.5⍰mm lateral to the muscle-midline) ...
-
bioRxiv - Neuroscience 2022Quote: ... The fluorophore (10 μM in HEPES-buffered E3) was loaded into a glass pipette (tip diameter: ~5 μm; Model P-97 Flaming/Brown Micropipette Puller, Sutter Instrument Co.) aimed ~20 μm away at the cupula ...
-
bioRxiv - Neuroscience 2021Quote: ... slices from were exposed to wide-field blue (λ=470nm) or amber (λ=589nm, 10 =589nm, mW/mm2) illumination using Lambda DG-4 Plus (Sutter Instruments, Novato, CA) or Thorlabs 4-Wavelength High-Power LED Sources (Thorlabs ...
-
bioRxiv - Neuroscience 2022Quote: ... The recordings were obtained using borosilicate glass pipettes (resistance 4–10 MΩ) prepared using a 2-stage vertical pipette puller (P-1000, Sutter Instrument, or PP-83, Narishige). The pipettes were filled with a solution containing the following (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Data were obtained using glass microelectrodes (3–5 MΩ) pulled using a Narishige PC-10 puller (Narishige Japan, Tokyo Japan) or Sutter P-1000 Glass puller (Sutter Instruments, Novato, CA) and were low-pass filtered at 3 kHz ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch electrodes (5-7 MΩ) were pulled from borosilicate glass capillaries using a Flaming/Brown P-97 micropipette puller (Sutter Instrument, Novato, CA). Pipette internal solution contained (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... Voltage signals were low-pass filtered at 500 Hz-1 kHz and digitized at 5-10 kHz using SutterPatch Software (Sutter Instruments, Novato CA). Following acquisition ...
-
bioRxiv - Physiology 2019Quote: ... were pulled to low tip resistance (5-7 MΩ) using a Flaming-Brown PC-84 micro-pipette puller (Sutter Instruments, Novato, CA, USA) and back-filled with 500 mM KCl solution ...
-
bioRxiv - Neuroscience 2023Quote: ... was injected into the midbrain ventricle together with tol2 mRNA (20ng/μl) and Phenol-red (∼0.025%) at 5-8nL using a micro glass needle (0.58mm inside diameter, Sutter Instrument, Germany, BF100-58-15) pulled using a micropipette puller (Model P-87 Sutter Instrument ...
-
bioRxiv - Physiology 2020Quote: ... glass microelectrodes were pulled to a tip resistance of 5-7 MΩ on a Flaming-Brown P-1000 Micropipette puller (Sutter Instruments, Novato, CA, USA). TPP was measured with a Duo 773 intracellular/extracellular amplifier (World Precision Instruments ...
-
bioRxiv - Physiology 2023Quote: ... pulled to form low resistance tips (approximately 5–7 MΩ) using a model P-87 Flaming/Brown micropipette puller (Sutter Instruments, Novato, CA, USA). These microelectrodes were backfilled with 500 mM KCl ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipette electrodes with a resistance of 5-9 MOhm were pulled from borosilicate glass (Multi Channel Systems; Cat.nr. 300034) using a horizontal puller (Sutter instrument CO. Model P-2000). The intra-pipette solution included (in mM) ...
-
bioRxiv - Cell Biology 2022Quote: ... After each injection the MuDPIT column was washed with buffer A and then the peptides separated over a 25 cm analytical column (100 μm ID, 5 μm tip pulled on a Sutter Instruments T-2000 tip puller) packed with 3 μm C18 resin (Phenomenex ...