Labshake search
Citations for Sutter Instruments :
251 - 300 of 397 citations for 6H Pyrrolo 1 2 1 2 imidazo 4 5 f 2 1 3 benzoxadiazole 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
A crucial role for dynamic expression of components encoding the negative arm of the circadian clockbioRxiv - Biochemistry 2023Quote: ... C18 AQ 3 μm 120 Å pore) pulled in-house (Sutter P-2000, Sutter Instruments, San Francisco, CA) with a 45-min gradient of 5–34% LC-MS buffer B (LC-MS buffer A ...
-
bioRxiv - Cell Biology 2023Quote: ... C18 AQ 3 μm 120 Å pore) pulled in-house (Sutter P-2000, Sutter Instruments, San Francisco, CA) with a 45 minute gradient of 5-30% LC-MS buffer B (LC-MS buffer A ...
-
bioRxiv - Cell Biology 2024Quote: ... C18 AQ 3 μm 120 Å pore) pulled in-house (Sutter P-2000, Sutter Instruments, San Francisco, CA) with a 45-min gradient of 5–30% LC-MS buffer B (LC-MS buffer A ...
-
bioRxiv - Cell Biology 2023Quote: ... and excitation light was selected with bandpass filters mounted in a filter wheel (Sutter Instruments Lambda 10-3) and delivered to a fiber optic cable and delivered to the TIRF illuminator ...
-
bioRxiv - Neuroscience 2024Quote: ... Glass capillaries (3-000-203-G/X, Drummond) were pulled at a capillary puller (P-97, Sutter Instrument), their tips trimmed using a fine forceps and beveled at 30 degrees using an electric capillary beveler (EG-400 ...
-
bioRxiv - Cell Biology 2021Quote: ... were pulled to resistances of 5 - 8 MΩ (P-2000; Sutter Instruments, Novato CA). The standard pipette solution contained (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... with a 5 or 10 µL microsyringe (Hamilton) equipped with a microinjector (Sutter Instrument) and controller (World Precision Instruments) ...
-
bioRxiv - Neuroscience 2024Quote: ... Glass pipettes (5-000-2005, Drummond) were pulled (Model P-97, Sutter Instrument Co) and further broken to obtain a tip of -10-15 µm inner diameter and further beveled to create a sharp tip and avoid cortical damage during insertion.Callosal projections tracings ...
-
bioRxiv - Molecular Biology 2024Quote: ... with a Flaming-Brown P-97 puller (Sutter Instruments; tip resistance 5–8 MΩ). The pipette solution contained (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell recordings were performed using borosilicate glass patch electrodes (4-6 MΩ; Sutter Instruments, Florida) pulled on a Narishige PC-10 pipette puller (Narishige ...
-
bioRxiv - Neuroscience 2024Quote: ... with resistances 4–6 MΩ were pulled using a laser micropipette puller (P-2000, Sutter Instrument) and filled with intracellular solution (in mM) ...
-
bioRxiv - Cell Biology 2020Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). Electrophysiological recordings from neurons were obtained in Tyrode’s medium ([mM] 150 NaCl ...
-
bioRxiv - Neuroscience 2022Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). Pipettes were filled using standard intracellular solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (3–6 MΩ) were manufactured from filamented borosilicate glass capillaries (Sutter Instruments, Novato, CA, BF100-58-10) and filled with an intracellular solution containing (in mM) ...
-
bioRxiv - Cell Biology 2022Quote: ... were used to pull patch pipettes (3 MΩ) on a horizontal Flaming/Brown micropipette puller (P-1000, Sutter Instruments) and polished by microforge (Narishige MF-830 ...
-
bioRxiv - Cell Biology 2019Quote: ... Red and green fluorescence images were obtained 200 ms apart using a filter wheel (Lambda 10-3, Sutter Instruments). To correct for x/y distortions between the two channels ...
-
bioRxiv - Neuroscience 2021Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). For hippocampal neuron cultures ...
-
bioRxiv - Biophysics 2023Quote: ... CT) to resistances of 1.5 MΩ to 3 MΩ using a micropipette puller (P-1000, Sutter Instruments, Novato, CA) and fire-polished ...
-
bioRxiv - Neuroscience 2020Quote: ... at approximately 5 mm away from the tip) using a laser electrode puller (Sutter Instrument, model P-2000 ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (3.5-5 MΩ) were pulled with P-97 horizontal micropipette puller (Sutter Instruments) filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Fluorescence measurements were performed under whole-field epi-illumination using a DG-4 light source (Sutter Instruments). Signals were detected by a Cool-Snap II HQ CCD camera (Photometrics ...
-
bioRxiv - Cell Biology 2021Quote: ... a NEO sCMOS DC-152Q-C00-FI camera (Andor) and a Lambda DG-4 lamp (Sutter Instruments). Images were acquired using the NIS Elements software (Nikon) ...
-
bioRxiv - Neuroscience 2022Quote: ... Fast switching between illuminations at 340 and 380 nm was performed with Lambda DG-4 (Sutter Instrument). Alternating F340 and F380 image pairs were obtained at acquisition rates of 0.3 to 2 image pairs per second ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass (3-7 MΩ resistance) recording pipettes were pulled using a P-1000 Flaming/ Brown micropipette puller (Sutter Instruments). Recordings were performed using an Axopatch 200B amplifier (Molecular Devices) ...
-
bioRxiv - Cell Biology 2021Quote: ... with motorized stage controller (MS-2000, ASI, Eugene, OR) and filter wheel controller (Lambda 10-3, Sutter Instrument, Novato, CA). The sample was illuminated with a LED light source (pE-300 ...
-
bioRxiv - Neuroscience 2021Quote: ... to a tip resistance of 3-4MOhms with a P-97 Flaming/Brown type micropipette puller (Sutter Instruments, Atlanta, Georgia).
-
bioRxiv - Neuroscience 2022Quote: ... Glass capillaries (G150F-3, Warner Instruments, Hamden) were pulled by a micropipette puller (Model P-87, SUTTER INSTRUMENT, Novato, USA) and their tips were mechanically crushed by approximately 2 mm ...
-
bioRxiv - Neuroscience 2022Quote: Fluorescence imaging was performed with a Lambda DG-5 wavelength changer (Sutter Instruments, Novato, CA, USA) and a Chroma 79001 filter set (340 nm and 380 nm band-pass filters for excitation ...
-
bioRxiv - Neuroscience 2024Quote: ... were pulled to resistances between 5–16 MΩ using a micropipette puller (Flaming/Brown; Sutter Instrument). For peripheral motor nerve recordings ...
-
bioRxiv - Neuroscience 2024Quote: ... A Lambda XL Xenon lamp (Sutter) with 5 mm liquid light guide (Sutter Instrument, Novato, CA) was used to illuminate samples ...
-
bioRxiv - Neuroscience 2021Quote: ... generated by a Lambda DG-4 high-speed optical switch with a 300 W Xenon lamp (Sutter Instruments) and an excitation filter set centered around 470 nm ...
-
bioRxiv - Cell Biology 2021Quote: ... which was centrifuged at 13200 rpm in 4°C for 10min prior to loading quartz needles (Sutter Instrument) for micro-injection (Eppendorf) ...
-
bioRxiv - Neuroscience 2022Quote: ... for patch clamp recordings (4 – 6 MΩ) were pulled using a micropipette puller (P1000, Sutter Instruments, Novato, CA).
-
bioRxiv - Neuroscience 2021Quote: ... for patch clamp recordings (4–7 MΩ) were pulled using a micropipette puller (P1000, Sutter Instruments, Novato, CA). Pipette capacitance was compensated for before the formation of the whole-cell configuration ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-6 MO) were pulled from thin wall borosilicate glass using a micropipette puller (Sutter Instruments) and filled with a K-Gluconate-based intra-pipette solution containing 116 mM KGlu ...
-
bioRxiv - Neuroscience 2022Quote: ... Glass pipettes (4–6 MΩ) were pulled from borosilicate capillaries (Outer diameter: 1.5mm; Inner diameter 0.86; Sutter Instrument) and filled with and internal solution (in mM ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-7 MΩ) were pulled from borosilicate glass capillaries on P-97 puller (Sutter Instruments, USA). The series resistance was 10-20 MΩ ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-6 MΩ) were pulled from borosilicate glass using a P-70 micropipette puller (Sutter Instruments).
-
Neuron-astrocyte metabolic coupling facilitates spinal plasticity and maintenance of persistent painbioRxiv - Neuroscience 2022Quote: ... Electrodes (4–8 MΩ) were pulled from borosilicate glass capillaries (O.D. 1.5 mm, I.D. 0.86 mm, Sutter Instruments, USA). Intrinsic firing properties of lamina 1 neurons were recorded in the presence of 10 mM CNQX ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass micropipettes (tip resistance 4-6 MΩ) were prepared using a P-1000 puller (Sutter Instruments, USA) and filled with an intracellular recording solution containing (in mM) ...
-
bioRxiv - Cell Biology 2021Quote: ... and emission light was separated using the following filters fitted into a filter wheel controlled by a Lambda 10-3 unit (Sutter Instruments): GFP/Alexa488 (530/50 ...
-
bioRxiv - Biophysics 2020Quote: ... A Lambda 10-3 filter switcher and shutter controller was used with a Lambda LB-LS/30 Xenon arc lamp (Sutter Instruments). Images were acquired at 1 frame/15 s for 5 m at low glucose and 1 frame/15 s for 25 m after stimulation high glucose using a Andor CCD camera ...
-
bioRxiv - Cancer Biology 2020Quote: ... and triple-band laser emission filter ZET405/488/561m (Chroma), mounted in the metal cube (Chroma, 91032) together with emission filter wheel Lambda 10-3 (Sutter instruments) with ET460/50m ...
-
bioRxiv - Neuroscience 2020Quote: Gross manipulation of the pipette is performed under manual control of the Sutter MP 285 3-axis patch manipulators (Sutter Instruments). Axial movements of the pipette are performed by the one-axis motorized translation stage (PT1-Z8 ...
-
bioRxiv - Cell Biology 2022Quote: ... 2D triple-color imaging were performed using an Olympus IX81 microscope equipped with a high-speed filter changer (Lambda 10-3; Sutter Instruments) that can change filter sets within 40 ms ...
-
bioRxiv - Neuroscience 2023Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼1-3-MΩ resistance for PCs and ∼3-6-MΩ resistance for MLIs pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument). Slice recordings with PC leak currents greater than 500 pA were rejected ...
-
bioRxiv - Physiology 2024Quote: ... imaging was performed using an upright microscope equipped with a Grasshopper 3 camera (FLIR) and a Lambda LS light source (Sutter Instrument). The entire area of each biosensor cell was used for the calculation of ΔF/F0 values ...
-
bioRxiv - Neuroscience 2024Quote: ... Warner Instruments) were pulled to have resistances of 3-7 MΩ using a Flaming-Brown pipette puller (model P-97; Sutter Instruments). The pipette tip was initially filled with a solution containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... were pulled to tip resistances of 5-8 M Ώ using a multi-stage puller (Sutter Instruments) and were filled with K-gluconate based intracellular solution ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes of 5–10 MΩ were pulled with a P-97 Flaming/Brown puller (Sutter Instruments) from borosilicate glass capillaries and the intracellular solution used contained (in mM) ...