Labshake search
Citations for Sutter Instruments :
251 - 300 of 463 citations for 10 14 Cadinene 4 5 Diol since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... and a pulled and beveled micropipette (P-1000 and BV-10, respectively, Sutter Instruments). Injection coordinates were chosen according to the mouse brain atlas43 ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Electrodes were pulled from borosilicate glass capillaries (#BF150-110-10, Sutter Instrument, Novato, CA) on a vertical pipette puller (Narishige ...
-
bioRxiv - Neuroscience 2023Quote: ... These organs were pinned down with a quartz capillary (QF100-70-10, Sutter Instrument) to reduce movement of the preparation.
-
bioRxiv - Bioengineering 2023Quote: ... A computer-controlled filter wheel and its corresponding controller (Sutter Instruments, Lambda 10-3) equipped with four filters were used to filter out non-fluorescent signals for the light sheet imaging ...
-
bioRxiv - Physiology 2023Quote: Pipettes were pulled from ultra-thick-walled borosilicate glass (BF200-116-10, Sutter Instruments) as described in previous section ...
-
bioRxiv - Biophysics 2024Quote: ... Micropipettes were pulled from thin wall borosilicate capillaires (BF100-78-10, Sutter Instruments, CA) using a Flaming/Brown micropipette puller (Model P-97 ...
-
bioRxiv - Neuroscience 2024Quote: Patch pipettes were pulled from borosilicate glass capillaries (BF1-86-10, Sutter Instruments, USA) with a vertical puller (PC100 ...
-
bioRxiv - Physiology 2024Quote: ... Patch pipettes were pulled from borosilicate glass (ITEM #:BF150-86-10, Sutter Instrument Co.) using a micropipette puller (P-97 ...
-
bioRxiv - Biophysics 2021Quote: ... Borosilicate glass patch pipettes of 3-5 MΩ were formed using a micropipette puller (Sutter Instruments, P-97) and then coated with Sylgard 184 silicone (Dow Corning) ...
-
bioRxiv - Molecular Biology 2020Quote: ... INS1 cells were excited by 340 and 387 nm light alternatively using a DG-4 xenon-arc lamp (Sutter Instruments) and emission signals were recorded at 510 nm every 3 s using CMOS charge-coupled device (CCD ...
-
bioRxiv - Neuroscience 2021Quote: ... ID: 0.86 mm) using a 4-stage program on a Flaming-Brown P-97 micropipette puller (Sutter Instruments, Novato, CA). Patch pipettes with tip resistance of 3-5 MΩ were filled with an internal solution ...
-
bioRxiv - Microbiology 2020Quote: ... were used to pull patch pipettes (3–4 MΩ) on a horizontal Flaming/Brown micropipette puller (P-97, Sutter Instruments) and then were backfilled with intracellular solution ...
-
bioRxiv - Biophysics 2020Quote: ... Electrodes (~0.3 MΩ) were fabricated from borosilicate glass (G100TF-4, Warner Instruments, LLC) on a horizontal puller (P-97; Sutter Instruments) and filled with 3 M KCl ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes (2–4 MΩ) were pulled from thin-walled borosilicate glass capillaries using a P95 pipette puller (Sutter Instruments). Signals were acquired using an Axon Multiclamp 700B amplifier (Molecular Devices) ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes with a tip resistance of 4–7MΩ were pulled with a flaming-Brown puller P-97 (Sutter Instruments) from borosilicate glass capillaries (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... to a resistance of 2–4 MΩ using a horizontal puller (P-97 or P-1000; Sutter Instruments, Novato, CA). In most experiments ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... Patch pipettes (4-7 MΩ) were pulled from thin wall borosilicate glass using a micropipette puller (P-97, Sutter Instruments) and filled with a K-Gluconate based intra-pipette solution containing ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes were pulled from glass capillaries (PG52151-4, Word Precision Instruments) using a P97 puller (Sutter Instruments, California, USA). Recording pipettes had 2.0–4.0 MΩ open-tip resistance in the bath solution ...
-
bioRxiv - Biochemistry 2020Quote: ... Pipettes were pulled from borosilicate glass (BF 150-86-10; Sutter Instrument, Novato, CA, USA) with a Sutter P-1000 pipette puller ...
-
bioRxiv - Neuroscience 2020Quote: Intracellular recordings were performed using sharp microelectrodes (borosilicate glass, BF100-50-10; Sutter Instruments, CA) with a resistance of 80-120MO when filled with 3M KCl and 5% Neurobiotin at the tip ...
-
bioRxiv - Neuroscience 2022Quote: ... Borosilicate glass pipettes (O.D. = 1.5 mm, I.D. = 0.86 mm, item #BF150-86-10, Sutter Instruments) for patch clamp recordings (4 – 6 MΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... electrodes were made by pulling borosilicate glass pipette with filament (Sutter Instruments, BF100-50-10) to a resistance of 9-11 MΩ ...
-
bioRxiv - Cell Biology 2020Quote: ... These filters were alternated by a filter-changer Lambda 10–2(Sutter Instruments, Novato, CA). Exposure time was 50–500 ms ...
-
bioRxiv - Biophysics 2020Quote: Microelectrodes were made with thin wall borosilicate glass (B150-117-10, Sutter Instrument, Novato, CA) by a micropipette puller (P-97 or P-1000 ...
-
bioRxiv - Neuroscience 2022Quote: ... Glass micropipettes (O.D. 1 mm, I.D. 0.5 mm Sutter Instruments, cat no. BF100-50-10) pulled by using a P1000 pipette puller (Shutter Instruments ...
-
bioRxiv - Developmental Biology 2022Quote: ... CFP: FF01-482/35-25) mounted on a filter wheel (Sutter Instruments Lambda 10-3) and a short-pass 750nm filter ...
-
bioRxiv - Neuroscience 2024Quote: ... patch pipettes were prepared from borosilicate glass capillaries (Sutter Instrument, Cat. Nu. BF150-75-10) using a P-97 pipette puller (Sutter Instrument ...
-
bioRxiv - Genomics 2024Quote: ... We prepared microinjection needles using aluminosilicate glass capillaries (catalog no. AF100-64-10, Sutter Instrument). We chose the aluminosilicate glass rather than regular borosilicate glass because it penetrates the chorion and membrane of Daphnia embryos at high efficiency and incurs little clogging at a fine tip size ...
-
bioRxiv - Neuroscience 2023Quote: ... were injected in the lateral ventricle using a glass capillary (B100-58-10, Sutter Instrument). 3 mm diameter platinum tweezer electrodes (CUY650P3 ...
-
bioRxiv - Biophysics 2022Quote: Needles used for dye microinjections were fabricated from borosilicate capillaries (B100-75-10, Sutter Instruments) using a pipette puller (P-2000 ...
-
bioRxiv - Neuroscience 2023Quote: ... electrodes were made by pulling borosilicate glass pipette with filament (Sutter Instruments, BF100-50-10) to a resistance of 9-11 MΩ ...
-
bioRxiv - Neuroscience 2024Quote: Electrodes were fashioned from borosilicate glass capillaries (BF150-110-10, Sutter Instrument Co., Novato, CA) using a P-1000 micropipette puller (Sutter Instrument Co. ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes were made from thick-walled borosilicate glass (BF150-86-10, Sutter Instrument, CA). Glass pipets were pulled by P-97 Flaming/Brown micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2024Quote: ... 1.50 mm/1.10 mm (OD/ID) borosilicate glass capillary tubes (Sutter Instruments; BF150-110-10) were pulled to a selected length using a P-2000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Physiology 2024Quote: Recording pipettes were made with borosilicate glass (BF-150-86-10; Sutter Instruments, CA, USA) using a puller (P-97 ...
-
bioRxiv - Neuroscience 2020Quote: ... Pipettes pulled from borosilicate glass capillary tubes (cat. no. G85150T-4, Warner Instruments) using a P-97 pipette puller (Sutter Instrument) were filled with the following intracellular solution (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... Micropipettes (2-4 MΩ) were pulled from borosilicate capillaries (Science Products GmbH) with a P-97 Flaming/Brown Micropipette Puller (Sutter Instruments). The cell capacitance and series resistance were always compensated (up to 75%).
-
bioRxiv - Neuroscience 2022Quote: ... all electrophysiological experiments were performed in whole cell voltage clamp mode at −70 mV using borosilicate pipettes (4-6 MΩ) made on NARISHIGE puller (NARISHIGE, PG10) from borosilicate tubing (Sutter Instruments) and filled by an internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... in callosal PV terminals was performed using ∼4-5mW flashes of light generated by a Lambda DG-4 high-speed optical switch with a 300W Xenon lamp (Sutter Instruments), and an excitation filter set centered around 470 nm ...
-
bioRxiv - Neuroscience 2022Quote: ... Illumination and wavelength switching was provided by a Lambda DG-4 high speed filter changer (Sutter Instrument Company, Novato, California, USA). The four wavelengths were chosen as two specific pairs (494 nm ± 31 FWHM and 560 nm ± 16 FWHM ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell current-and voltage-clamp recordings were performed in a recording chamber at room temperature using pulled borosilicate glass pipettes (4-7 MΩ resistance, Sutter Instrument) filled with internal solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... and monopolar stimulator pipettes (3 – 4 MΩ) were obtained from borosilicate glass capillaries with a horizontal pipette puller (P-97, Sutter Instruments). The internal pipette solution contained the following (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Maximal melanopsin-based intrinsic photocurrents were elicited with a 100 ms 480 nm blue-light stimulus delivered from a Lambda DG-4 light source (Sutter Instruments) with an intensity of 2 x 1010 photons um-2 s-1 ...
-
Entorhinal cortex vulnerability to human APP expression promotes hyperexcitability and tau pathologybioRxiv - Neuroscience 2024Quote: ... Pipettes (1–3 MΩ) with a long shank (∼2 cm) were pulled from borosilicate glass capillaries (1.65mm O.D, #PG52615-4, Sutter instruments Co., USA) using a vertical puller (Narishige PC-100) ...
-
bioRxiv - Physiology 2024Quote: ... 340 nm and 380 nm excitation were delivered by a high-intensity 150W Xenon arc lamp (Lambda DG-4; Sutter Instruments), high pass-filtered at 510 nm and detected with a 12-bit Delta Evolve camera (Photometrics/Teledyne).
-
bioRxiv - Neuroscience 2024Quote: ... all electrophysiological experiments were performed in whole cell voltage clamp mode at -70 mV using borosilicate pipettes (4-6 MΩ) manufactured by Narishige puller or pulled using NARISHIGE puller (NARISHIGE, PG10) from borosilicate tubing (Sutter Instruments) and filled by an internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... ipRGCs were identified by tdTomato fluorescence using a short exposure to 540 nm light (<1s; 1 x 106 photons cm-2 s-1; Lambda DG-4, Sutter Instruments).
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate pipettes of 5 – 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter instruments). All recordings were done in current clamp with an intracellular solution containing 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2020Quote: The STG was desheathed dorsally and neuron somata were impaled using glass microelectrodes (ID: 0.86 mm; OD: 1.5 mm; 5-20 MΩ; Sutter Instrument). Microelectrodes were backfilled with a solution containing 10 mM MgCl2 ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Patch electrodes with resistances of 2-5 MΩ were pulled with a P-97 micropipette puller (Sutter Instruments, USA). The conventional whole-cell recordings were obtained by manual suction for hERG ...