Labshake search
Citations for Sutter Instruments :
51 - 100 of 152 citations for Dl 4 Methoxyestradiol 13 14 15 16 17 18 13C6 99% since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... using a Lambda DG-4 high-speed filter changer (Sutter Instrument Company, USA), the cortex under the thinned window was illuminated with four wavelengths of light (587±9nm ...
-
bioRxiv - Neuroscience 2023Quote: ... Fire polished borosilicate pipettes with 3-4 MOhm resistance (Sutter Instruments, Novato, CA) were filled with either Cs-gluconate or K-gluconate internal solutions ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (4-7 MΩ) were pulled from borosilicate glass filaments (Sutter Instruments) and filled with a Cesium (Cs2+)-based internal solution (in mM ...
-
bioRxiv - Neuroscience 2024Quote: ... The glass electrode (4∼6 MΩ) was pulled by P-97 (Sutter Instrument) and filled with a patch pipette solution containing 125mM K-gluconate ...
-
bioRxiv - Neuroscience 2023Quote: ... was injected into the midbrain ventricle together with tol2 mRNA (20ng/μl) and Phenol-red (∼0.025%) at 5-8nL using a micro glass needle (0.58mm inside diameter, Sutter Instrument, Germany, BF100-58-15) pulled using a micropipette puller (Model P-87 Sutter Instrument ...
-
bioRxiv - Developmental Biology 2023Quote: ... Both the holding pipette and pulled needle were custom-made from glass capillaries (Warner Instrument, GC100T-15) using a micropipette puller (Sutter Instrument, P-1000) and a microforge (Narishige ...
-
bioRxiv - Cell Biology 2023Quote: ... The front end of the capillary was forged to an outer diameter of 15 μm using a capillary puller (Sutter Instrument, Novato, USA) and bent to an angle of 45° using a homemade microforge ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (3-15 MΩ) were pulled from borosilicate glass (GB150F-10, Scientific Products GmbH, Germany) with a horizontal puller (P-1000, Sutter Instruments, Novato, CA, USA). The internal solution contained (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: Pipettes with 4 to 6 MΩ resistance were pulled from borosilicate glass (Sutter Instruments) and filled with an intracellular solution of following composition (mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipette (4-7 MOhm) were pulled from borosilicate glass filaments (Sutter Instrument Co.) and filled with potassium (K)-gluconate solution (GCamp7s characterization ...
-
bioRxiv - Neuroscience 2019Quote: Experimentation and shutter control was automated (Lambda DG-4/Lambda 10-B, Sutter Instruments) and two application protocols were used ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (4 – 7 MΩ) pulled from borosilicate glass (Sutter instrument, BF150-86-10) were filled with a K-gluconate based internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... with 4-7 MΩ borosilicate pipettes (2.0 mm OD, 1.16 mm ID, Sutter Instruments) filled with a standard low-chloride internal solution (120 mM potassium gluconate ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes (2–4 MΩ) pulled from borosilicate glass (BF150-86-7.5, Sutter Instruments) were filled with a Cs+-based internal solution containing (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... to a resistance of 2–4 MΩ using a horizontal puller (Sutter Instrument P97). The internal recording solution contained in (mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (4-7 MOhm) were pulled from borosilicate glass filaments (Sutter Instrument Co.) and filled with Cesium (Cs2+)-based internal solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (2–4 MΩ) pulled from borosilicate glass (BF150-86-7.5, Sutter Instruments) were filled with a Cs+-based internal solution containing (in mM) ...
-
bioRxiv - Biophysics 2024Quote: ... Cells expressing TdTomato were identified using a DG-4 light excitation system (Sutter instruments). Voltage-clamp recordings were obtained using borosilicate glass pipettes with 4-6MΩ resistance filled with the following intracellular solution (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes of 4-6 MOhm resistance were pulled from borosilicate glass filaments (Sutter Instruments) and filled with K-gluconate solution (in mM ...
-
bioRxiv - Neuroscience 2019Quote: ... a blue light pulse (GFP filter, centered around 485 nm, Lambda DG-4, Sutter instruments) was applied through the objective (40× ...
-
bioRxiv - Neuroscience 2022Quote: Recording electrodes (2-4 MΩ) were pulled on a P-97 Micropipette Puller (Sutter Instruments). All recordings were conducted with potassium-gluconate intercellular recording solution [in mM ...
-
bioRxiv - Cell Biology 2024Quote: ... a high-speed Xenon fluorescence emission device (Lambda DG-4, 300 W; Sutter Instrument Company), a Lambda 10-3 optical emission filter wheel for the fluorescence imaging ...
-
bioRxiv - Neuroscience 2019Quote: ... 575±5 nm) using a Lambda DG-4 high-speed filter changer (Sutter Instrument Company, USA). The re-emitted light was collected at a frame rate of 32Hz using a Dalso 1M60 CCD camera which was synchronized to the filter switching ...
-
bioRxiv - Neuroscience 2020Quote: ... with resistances of 3 – 4 MΩ were crafted using a P97 horizontal pipette puller (Sutter Instrument) and filled with internal solution containing (in mM) ...
-
bioRxiv - Biophysics 2022Quote: ... Patch pipettes with a resistance of 2 – 4 MΩ were fabricated from borosilicate glass (Sutter instrument) and fire polished ...
-
bioRxiv - Neuroscience 2022Quote: ... with resistances of 3 – 4 MΩ were crafted using a P1000 horizontal pipette puller (Sutter Instrument) and filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell recordings were performed using borosilicate glass patch electrodes (4-6 MΩ; Sutter Instruments, Florida) pulled on a Narishige PC-10 pipette puller (Narishige ...
-
bioRxiv - Biophysics 2022Quote: ... Patch pipettes with a resistance of 2 – 4 MΩ were fabricated from borosilicate glass (Sutter instrument). Solution exchange was achieved with a fast-step perfusion system (Warner instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... with resistances of 3 – 4 MΩ were crafted using a P1000 horizontal pipette puller (Sutter Instrument) and filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... with resistances 4–6 MΩ were pulled using a laser micropipette puller (P-2000, Sutter Instrument) and filled with intracellular solution (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... with resistances of 3 – 4 MΩ were crafted using a P1000 horizontal pipette puller (Sutter Instrument) and filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Fluorescence measurements were performed under whole-field epi-illumination using a DG-4 light source (Sutter Instruments). Signals were detected by a Cool-Snap II HQ CCD camera (Photometrics ...
-
bioRxiv - Cell Biology 2021Quote: ... a NEO sCMOS DC-152Q-C00-FI camera (Andor) and a Lambda DG-4 lamp (Sutter Instruments). Images were acquired using the NIS Elements software (Nikon) ...
-
bioRxiv - Neuroscience 2022Quote: ... Fast switching between illuminations at 340 and 380 nm was performed with Lambda DG-4 (Sutter Instrument). Alternating F340 and F380 image pairs were obtained at acquisition rates of 0.3 to 2 image pairs per second ...
-
bioRxiv - Neuroscience 2021Quote: ... generated by a Lambda DG-4 high-speed optical switch with a 300 W Xenon lamp (Sutter Instruments) and an excitation filter set centered around 470 nm ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch electrodes (2–4 MΩ) were pulled from borosilicate capillary glass of external diameter 1 mm (Sutter Instruments) using a Flaming/Brown micropipette puller (model P-2000 ...
-
bioRxiv - Cell Biology 2021Quote: ... which was centrifuged at 13200 rpm in 4°C for 10min prior to loading quartz needles (Sutter Instrument) for micro-injection (Eppendorf) ...
-
bioRxiv - Neuroscience 2022Quote: ... for patch clamp recordings (4 – 6 MΩ) were pulled using a micropipette puller (P1000, Sutter Instruments, Novato, CA).
-
bioRxiv - Neuroscience 2021Quote: ... for patch clamp recordings (4–7 MΩ) were pulled using a micropipette puller (P1000, Sutter Instruments, Novato, CA). Pipette capacitance was compensated for before the formation of the whole-cell configuration ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-6 MO) were pulled from thin wall borosilicate glass using a micropipette puller (Sutter Instruments) and filled with a K-Gluconate-based intra-pipette solution containing 116 mM KGlu ...
-
bioRxiv - Neuroscience 2022Quote: ... Glass pipettes (4–6 MΩ) were pulled from borosilicate capillaries (Outer diameter: 1.5mm; Inner diameter 0.86; Sutter Instrument) and filled with and internal solution (in mM ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-7 MΩ) were pulled from borosilicate glass capillaries on P-97 puller (Sutter Instruments, USA). The series resistance was 10-20 MΩ ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-6 MΩ) were pulled from borosilicate glass using a P-70 micropipette puller (Sutter Instruments).
-
Neuron-astrocyte metabolic coupling facilitates spinal plasticity and maintenance of persistent painbioRxiv - Neuroscience 2022Quote: ... Electrodes (4–8 MΩ) were pulled from borosilicate glass capillaries (O.D. 1.5 mm, I.D. 0.86 mm, Sutter Instruments, USA). Intrinsic firing properties of lamina 1 neurons were recorded in the presence of 10 mM CNQX ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass micropipettes (tip resistance 4-6 MΩ) were prepared using a P-1000 puller (Sutter Instruments, USA) and filled with an intracellular recording solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... In order to measure changes in cortical haemodynamics a Lambda DG-4 high-speed galvanometer (Sutter Instrument Company, USA) was used to illuminate the right somatosensory cortex with 4 wavelengths of light (495 ± 31nm ...
-
bioRxiv - Neuroscience 2021Quote: ... Fluorescence measurements were performed under whole-field epi-illumination using a DG-4 light source (Sutter Instruments, Novato, CA). Signals were detected by a CoolSnap II HQ CCD camera (Photometrics ...
-
bioRxiv - Physiology 2021Quote: ... Recording electrodes (3–4 MΩ) were pulled on a model P-87 micropipette puller (Sutter Instruments, Novado, CA, USA) and polished using a MF-830 MicroForge (Narishige Scientific Instruments Laboratories ...
-
bioRxiv - Neuroscience 2022Quote: ... recording pipettes with a resistance of 4-6 MΩ were obtained using the SU-P97 puller (Sutter Instrument Company). Recordings were carried out at room temperature (24-25°C) ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch glass pipettes (4-9 MΩ, Hilgenberg) were pulled by a P-97 Flaming/Brown puller (Sutter Instruments, USA) from borosilicate glass capillaries and loaded with intracellular solution (ICS ...