Citations for Sutter Instruments :
51 - 83 of 83 citations for 6 9 Anthroyloxy stearic acid 6 as since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes (Hilgenberg) of 6 - 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter Instruments). The intracellular solution contained 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes with an open tip resistance of 4-6 MΩ were prepared from borosilicate glass (Sutter Instrument BF150-86-10) using a Flaming/Brown pipette puller (Sutter Instrument SU-P97) ...
-
bioRxiv - Neuroscience 2023Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼1-3-MΩ resistance for PCs and ∼3-6-MΩ resistance for MLIs pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument). Slice recordings with PC leak currents greater than 500 pA were rejected ...
-
bioRxiv - Neuroscience 2024Quote: ... equipped with infrared-oblique illumination and patched with pipettes of 3 to 6 MΩ (#30-0060, Warner Instruments) made with a laser puller (P-2000, Sutter Instruments). The pipette solution contained (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Whole-cell patch-clamp recordings were performed on fluorescently labeled cells using 6–8 MΩ resistance glass microelectrodes (BF150-86-10; Sutter Instrument) containing an internal solution comprised of (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... all electrophysiological experiments were performed in whole cell voltage clamp mode at -70 mV using borosilicate pipettes (4-6 MΩ) manufactured by Narishige puller or pulled using NARISHIGE puller (NARISHIGE, PG10) from borosilicate tubing (Sutter Instruments) and filled by an internal solution containing (in mM) ...
-
bioRxiv - Molecular Biology 2024Quote: ... and a 30-50 cm-long analytical column with an integrated spray tip (6-8 μm-diameter opening, pulled on a P-2000 laser puller from Sutter Instruments) made with 75-μm-inner diameter fused silica and 1.9 μm-diameter Reprosil-Pur C-18-AQ beads (Dr ...
-
bioRxiv - Neuroscience 2021Quote: ... POMC neurons in the arcuate nucleus were visually identified by GFP expression and subjected to whole cell patch clamp using 3-6 MΩ borosilicate glass micropipettes (Sutter Instruments, UK) filled with potassium gluconate internal containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... Cells were patched with BF150-75-10 glass pipettes (∼ 6 MΩ) pulled with a Flaming Brown Micropipette Puller (Model P-97, Sutter Instruments, US). Pipettes were mounted on a MP-225 micromanipulator and filled with an intracellular solution containing 120mM K-gluconate ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-6 MΩ resistance) were pulled from borosilicate capillaries using a P-97 Flaming/Brown micropipette puller (Sutter Instrument Co.). For recording sEPSCs ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were then conducted at RT using pipettes with resistances typically ranging from 6-8 MΩ (P-2000, Sutter Instruments, USA). The pipette solution consisted of the following concentrations (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes with a resistance of 4–6 MΩ were pulled with a laser-based micropipette puller (P-2000, Sutter Instrument Company). Signals were recorded with a Multi Clamp 700B amplifier and pClamp11 software (Molecular Devices ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes (4-6 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) with a micropipette puller (P-87, Sutter Instruments Co.) and filled with a potassium gluconate-based intracellular solution containing (in mM) ...
-
bioRxiv - Physiology 2021Quote: ... Borosilicate patch pipettes were pulled and polished to resistance of 3-6 MΩ for all experiments using a micropipette puller (model P-97, Sutter Instruments, Novato, CA). Freshly dissociated arterial myocytes were kept in ice-cold Mg2+-PSS before being recorded.
-
bioRxiv - Biophysics 2024Quote: ... Patch pipettes with a resistance of 2-6 MΩ were fabricated from thin-walled borosilicate glass on a horizontal puller (Model P-1000, Sutter Instruments, Novato, USA). The series resistance was <15 MΩ ...
-
bioRxiv - Physiology 2024Quote: ... Borosilicate patch pipettes were pulled and polished to resistances of 3-6 MΩ for all experiments using a micropipette puller (model P-97, Sutter Instruments, Novato, CA).
-
bioRxiv - Physiology 2023Quote: ... Borosilicate patch pipettes were pulled and polished to resistances of 3-6 MΩ using a micropipette puller (model P-97, Sutter Instruments, Novato, CA).
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes with a tip resistance of 3–6 MΩ were prepared using a P-97 puller (Sutter Instruments, Novato, CA, USA) and filled with intracellular recording solution (ICS ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... Patch pipettes were pulled to a tip resistance of 6-8 MΩ using borosilicate glass capillary tubes with a P-1000 micropipette puller (Sutter Instrument, Novato, CA, USA). Current clamp recording was performed using a Multiclamp 700B amplifier (Axon Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... Glass micropipettes with a tip resistance of 3-6 MΩ were prepared using a micropipette puller model P-1000 (Sutter Instrument Co., California, USA) and were filled with an intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... Whole-cell recordings were obtained from fluorescently-labelled DRN 5-HT and SOM neurons and unlabeled mPFC L5 pyramidal neurons using glass electrodes (Sutter Instruments; tip resistance 4 to 6 MOhm). For most experiments ...
-
bioRxiv - Neuroscience 2024Quote: Patch pipettes (5-9 MΩ) were pulled from borosilicate glass pipettes (Sutter Instruments) using a vertical 2-stage puller (Narishige PP-830 ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass micropipettes were fabricated from borosilicate glass capillaries (8-9 MΩ; Sutter Instruments) with the use of a horizontal puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch micropipettes (7-9 MΏ) were pulled from borosilicate glass capillaries (Sutter Instrument, Novato, CA, USA.) using the Sutter Instrument P97 puller ...
-
bioRxiv - Neuroscience 2024Quote: ... were pulled (tip resistance of about 9–12 MΩ) using a (P1000, Sutter Instrument, Novato, CA, United States) and filled with an internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch glass pipettes (4-9 MΩ, Hilgenberg) were pulled by a P-97 Flaming/Brown puller (Sutter Instruments, USA) from borosilicate glass capillaries and loaded with intracellular solution (ICS ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch-clamp electrodes (6.5-9 MΩ) were pulled from glass capillaries (1.5×0.86 mm) using electrode puller (Sutter Instrument P1000). Recording electrodes were filled with an internal solution composed of the following (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... pulled to a 7-9 MOhm resistance with a micropipette puller (Cat#P-1000, Sutter Instrument, Novato, CA, USA)] was lowered into the LHb (coordinates ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes (9-12 MΩ) were fashioned from borosilicate glass capillaries (without filament) using a Flaming-Brown puller (Sutter Instrument #P-97) and further polished with a MF200 microforge (WPI ...
-
bioRxiv - Neuroscience 2021Quote: ... the right somatosensory cortex was illuminated using 4 different wavelengths of light appropriate to the absorption profiles of the differing haemoglobin states (495nm ± 31, 559nm ± 16, 575nm ± 14 & 587nm ± 9) using a Lambda DG-4 high-speed galvanometer (Sutter Instrument Company, US). A Dalsa 1M60 CCD camera was used to capture the re-emitted light from the cortical surface ...
-
bioRxiv - Neuroscience 2020Quote: ... the right somatosensory cortex was illuminated using 4 different wavelengths of light appropriate to the absorption profiles of the differing haemoglobin states (495nm ± 31, 559nm ± 16, 575nm ± 14 & 587nm ± 9) using a Lambda DG-4 high-speed galvanometer (Sutter Instrument Company, US). A Dalsa 1M60 CCD camera was used to capture the re-emitted light from the cortical surface ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes with electrode resistance of 4-9 MΩ were pulled with Zeitz puller (Werner Zeitz, Martinsried, Germany) from borosilicate thick glass (GC150F, Sutter Instruments, Novato, CA) and with an intracellular patch pipette solution containing 120 mM K-gluconate ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipette electrodes with a resistance of 5-9 MOhm were pulled from borosilicate glass (Multi Channel Systems; Cat.nr. 300034) using a horizontal puller (Sutter instrument CO. Model P-2000). The intra-pipette solution included (in mM) ...