bioRxiv - Neuroscience 2020Quote: ... Only virus transduced mice identified by their fluorescence upon excitation with a 572 nm LED (Cairn Research) were recorded using patch pipettes of 5–10 MΩ (P-97 Flaming/Brown puller, Sutter Instruments) containing intracellular solution (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Up to ~1.2 μL of viral solution per brain hemisphere were injected at cortical depths of 400 – 500 μm with a glass micropipette (Blaubrand IntraMARK 5 μl) pulled to about 10 – 20 μm inner diameter at the tips using a horizontal puller (Sutter Instruments). Usually 2–3 sites per hemisphere in S1 cortex were injected to increase the transduced brain area ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were performed using a Sutter IPA amplifier (1 kHz low-pass Bessel filter and 10 kHz digitization) using Sutter Patch software (Sutter Instruments). Voltage-clamp recordings were made using glass patch pipettes with resistance 2-4 MOhms ...
-
bioRxiv - Microbiology 2022Quote: ... Glass needles were made by pulling a capillary (GB100TF-10, 0.78 × 1.00 × 100 mm; Science Products, Hofheim, Germany) on a P-97 micropipette puller (Sutter Instrument, Novato, California). Tips of the needles were cut with a razor blade ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes with an open tip resistance of 4-6 MΩ were prepared from borosilicate glass (Sutter Instrument BF150-86-10) using a Flaming/Brown pipette puller (Sutter Instrument SU-P97) ...
-
bioRxiv - Neuroscience 2022Quote: ... Whole-cell patch-clamp recordings were performed using a Sutter IPA amplifier (1 kHz low-pass Bessel filter and 10 kHz digitization) using SutterPatch software (Sutter Instruments). Voltage-clamp recordings at -70 mV were made using glass patch pipettes with resistance 2-4 MOhms ...
-
bioRxiv - Biophysics 2023Quote: ... in positive mode with a nanospray tip pulled in-house with a Flaming/Brown P-97 micropipette puller from thin-walled glass capillaries (i.d. 0.78 mm, o.d. 1.0 mm, 10 cm length, both from Sutter Instrument Co., Novato, CA, USA). A positive potential of 1.2-1.6 kV was applied to the solution via a thin platinum wire ...
-
bioRxiv - Neuroscience 2023Quote: ... A small hole was drilled in the exposed skull and a 10 µl Hamilton syringe connected to a borosilicate injection micropipette pulled using a P-2000 puller (Sutter Instrument) coupled with a Quintessential Stereotaxic Injector (Stoelting ...
-
bioRxiv - Neuroscience 2023Quote: ... was connected to the ground/reference electrode and slowly implanted into motor cortex using stereotactic procedures at a rate ∼5-10 µm/s under remote micromanipulator control (QUAD, Sutter Instruments) and visualised through a microscope (GT Vision) ...
-
bioRxiv - Neuroscience 2023Quote: ... Antibodies were injected to lateral ventricular of pups by glass pipette with a sharp bevel at 45 degrees (BV-10 Micropipette Beveler, Sutter instrument). The diameter of pipette tip was ∼40-80μm (Vogt et al. ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were performed using a Sutter IPA amplifier (1 kHz low-pass Bessel filter and 10 kHz digitization) using Sutter Patch software (Sutter Instruments). Voltage-clamp recordings were made using glass patch pipettes with resistance 2-4 MOhms ...
-
bioRxiv - Neuroscience 2020Quote: ... Cells were patched with BF150-75-10 glass pipettes (∼ 6 MΩ) pulled with a Flaming Brown Micropipette Puller (Model P-97, Sutter Instruments, US). Pipettes were mounted on a MP-225 micromanipulator and filled with an intracellular solution containing 120mM K-gluconate ...
-
bioRxiv - Molecular Biology 2019Quote: ... Mouse embryos were exposed in the uterus and 1 μL of DNA solution with 0.01% Fast Green was injected into the lateral ventricles of embryos through a sharped micropipette by a microelectrode beveler BV-10 (Sutter Instrument, USA). Plasmids were prepared in 0.9% sterilizing saline at the concentrations of 1 μg/μL for EYFP ...
-
bioRxiv - Physiology 2021Quote: ... Low resistance electrodes (5-10 megaohms) were fashioned from cleaned capillaries using the P-87 Faming/Brown micropipette puller (Sutter Instrument Co.). The electrodes were silanized with dichlorodimethylsilane (440272-100ml ...
-
bioRxiv - Cancer Biology 2021Quote: ... non-filamented borosilicate micropipettes were pulled to a resistance of 5-10 MΩ (P-97 micropipette puller, Sutter Instruments, Novato, CA, USA) and coated with a hydrophobic layer of N,N-dimethyltrimethylsilylamine (Sigma Aldrich ...
-
bioRxiv - Genetics 2019Quote: ... were pulled and beveled using the Sutter P-2000 Micropipette Puller and Sutter BV-10 Micropipette Beveller (Sutter Instrument Co., Novato, CA). Embryo microinjections were performed using a Leica DM 1000 LED Micromanipulator (Leica Biosystems ...
-
bioRxiv - Neuroscience 2021Quote: ... Data were obtained using glass microelectrodes (3–5 MΩ) pulled using a Narishige PC-10 puller (Narishige Japan, Tokyo Japan) or Sutter P-1000 Glass puller (Sutter Instruments, Novato, CA) and were low-pass filtered at 3 kHz ...
-
bioRxiv - Neuroscience 2021Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ~4 MΩ resistance pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument, Novato, CA). Electrophysiology data was acquired using a Multiclamp 700B amplifier (Axon Instruments) ...
-
bioRxiv - Neuroscience 2020Quote: Single-unit extracellular spikes were recorded with micropipettes which were pulled from quartz glass tubes (Sutter Instrument, Novato, CA; product QF100-50-10) using a laser electrode puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2021Quote: ... Voltage signals were low-pass filtered at 500 Hz-1 kHz and digitized at 5-10 kHz using SutterPatch Software (Sutter Instruments, Novato CA). Following acquisition ...
-
bioRxiv - Developmental Biology 2019Quote: ... Fluorescence excitation was provided by a Nikon Intensilight C-HGFI 130-W mercury lamp and shuttered with a Lambda 10-B SmartShutter (Sutter Instruments, Novato, CA), also controlled through the SPOT software ...
-
A transcriptomic atlas of the mouse cerebellum reveals regional specializations and novel cell typesbioRxiv - Genomics 2020Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼4 MΩ resistance pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument, Novato, CA). Electrophysiology data was acquired using a Multiclamp 700B amplifier (Axon Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... Focal CPA (0.1 mg/ml) and SR101 (0.1 mg/ml) application was performed by means of borosilicate glass pipettes (BF150-86-10, Sutter Instrument, Novato, CA, US) mounted on 3-axis micromanipulator units (LN Mini 25 ...
-
bioRxiv - Developmental Biology 2021Quote: ... Embryos were then injected with fluorescein dextran using a Narishige micromanipulator connected to a Harvard Apparatus injector and quartz needles (Sutter Instrument GF100-50-10).
-
bioRxiv - Neuroscience 2019Quote: ... The uterine horn was then exposed to allow injection of 0.5-1.0 μl of DNA solution (containing 1 μg/μl plasmid and 0.1% Fast Green) into the lateral ventricles using a pressure-injector (Picospritzer III, Parker Hannifin) with pulled-glass pipettes (Sutter Instrument, BF150-117-10). To target L2/3 progenitor cells in prefrontal cortex for imaging and electrophysiological experiments ...
-
bioRxiv - Cancer Biology 2019Quote: ... A laser line filter (Chroma, ZET405/488/561/640) is placed after the detection objective lens and a filter wheel (Sutter Instrument, Lambda 10-B) equipped with multiple bandpass filters is placed between the tube lens and the camera ...
-
bioRxiv - Developmental Biology 2021Quote: ... Borosilicate capillary glass without a filament and with an outside diameter of 1 mm and an inner diameter of 0.75 mm (B100 – 75 – 10, Sutter Instrument Co., Novato, CA, USA) was used ...
-
bioRxiv - Neuroscience 2022Quote: ... Whole-cell patch clamp recordings were performed with 10cm fire polished borosilicate glass with filament pipettes (outer diameter: 1.5mm) (Sutter Instrument Cat# BF150-86-10) pulled to 3–6MΩ and filled with a potassium gluconate intracellular recording solution ((in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (3-15 MΩ) were pulled from borosilicate glass (GB150F-10, Scientific Products GmbH, Germany) with a horizontal puller (P-1000, Sutter Instruments, Novato, CA, USA). The internal solution contained (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... slices from were exposed to wide-field blue (λ=470nm) or amber (λ=589nm, 10 =589nm, mW/mm2) illumination using Lambda DG-4 Plus (Sutter Instruments, Novato, CA) or Thorlabs 4-Wavelength High-Power LED Sources (Thorlabs ...