Labshake search
Citations for Stoelting Company :
101 - 115 of 115 citations for PD 1 Mouse HEK293 His since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: Mice were anesthetized with isoflurane (Piramal Healthcare; 3–5% induction, 1–2% maintenance) before fixating their head to a stereotaxic apparatus (Stoelting). During the surgical procedure ...
-
bioRxiv - Neuroscience 2023Quote: Mice were anesthetized with isoflurane (1-5% isoflurane/1L O2/min) and placed on a double-armed stereotaxic frame (Stoelting). For acute viral injections ...
-
bioRxiv - Neuroscience 2023Quote: ... fCTB was injected at a concentration of 10 µg/µL at a speed of 0.1 µL/min using a 1 µL syringe driven by motorized stereotaxic injector (Stoelting 53310). The needle was left at the target for an additional 10 minutes to allow for settling of injected toxin before removal ...
-
bioRxiv - Neuroscience 2020Quote: ... was gradually injected into the sciatic nerve with one pump of a microsyringe pump at a rate of 1 μl/min (Stoelting Instruments). The needle tip was inserted into the epineural sheath ...
-
bioRxiv - Neuroscience 2020Quote: ... Mice were deeply anesthetized with isoflurane (5% induction, 1-2% maintenance) and mounted on the stereotaxic frame (Stoelting, Wood Dale, IL). Following craniotomy ...
-
bioRxiv - Neuroscience 2022Quote: ... were anaesthetized with isoflurane (5% induction, 1% maintenance) and placed on a stereotaxic apparatus (Ultra Precise stereotaxic instruments for mice; Stoelting Co.). After an incision was made in the scalp ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Tissue was then thawed and sliced into sequential 1 mm sections using a model 51425 tissue slicer (Stoelting, Wood Dale, IL). Brain slices were homogenized with 50 ul of PBS in 1.5 ml Eppendorf™ tubes using a Kontes® pellet pestle (VWR™ cat ...
-
bioRxiv - Neuroscience 2019Quote: ... The injection speed was 0.05 μl min-1 and was controlled by an injection pump (QSI No. 53311, Stoelting Co., IL). The pump and the syringe were held by a stereotactic arm that was attached on a stereotactic frame ...
-
bioRxiv - Neuroscience 2023Quote: ... Mice were deeply anesthetized with isoflurane (5% induction, 1-2% maintenance) and mounted on a stereotaxic frame (Stoelting, Wood Dale, IL). Following craniotomy ...
-
bioRxiv - Neuroscience 2020Quote: ... and sealed with a circular coverslip (Warner Instruments #1, 3 mm) affixed to the skull with cyanoacrylate glue and dental cement (Stoelting #51458 & 51456). A titanium omega bar was cemented to the interparietal bone ...
-
bioRxiv - Neuroscience 2022Quote: ... two 2-mm-thick sagittal slices taken 1 mm lateral from the inter-hemispheric fissure were cut using a sagittal slicer matrix (Alto Stainless Matrices, Stoelting, CO, USA) in PBS (Life Technologies Europe ...
-
bioRxiv - Neuroscience 2022Quote: ... The bouts and duration of explorations (nose <1 cm proximity) with the cylinderswas determined with ANYmaze software (Stoelting Co. Wood Dale Il.).
-
Juxtacrine DLL4-NOTCH1 signaling between astrocytes drives neuroinflammation via the IL-6-STAT3 axisbioRxiv - Neuroscience 2023Quote: ... were anaesthetized using isoflurane (3% induction and 1% maintenance) (Virbac Schweiz, Glattbrugg, Germany) and placed into a stereotactic frame (Stoelting Co., IL, USA). To prevent eye dryness ...
-
bioRxiv - Neuroscience 2019Quote: ... to a 25 μl Hamilton syringe via thin plastic Tygon™ tubing at a rate of 1 μl per minute by a microliter syringe pump (Stoelting Co., Wood Dale, IL). Microinjectors did not protrude more than 2 mm beyond the opening of the guide cannulae and were left in place for 1 minute after infusion to allow the drug to diffuse away from the injection needle ...
-
bioRxiv - Neuroscience 2019Quote: ... Tubing used for infusions were a thin plastic Tygon™ tubing at a rate of 1 μl per minute by a microliter syringe pump (Stoelting Co., Wood Dale, IL). Microinjectors did not protrude more than 2 mm beyond the opening of the guide cannulae and drug diffusion remained for 1 minute after infusion to allow the drug to diffuse away from the injection needle ...