Labshake search
Citations for Stoelting Company :
451 - 500 of 1470 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... A drill bit (Stoelting 514551) was used to create a burr hole in the skull and a glass capillary filled with a retrograde tracer was lowered through the hole to the injection site ...
-
bioRxiv - Neuroscience 2023Quote: ... Time and locomotor parameters for each task and zone were recorded using Any-Maze software (Stoelting, IL, USA).
-
bioRxiv - Neuroscience 2023Quote: ... mice were again allowed to freely explore for 30 min whilst their position was recorded using an infrared camera and AnyMaze 7.16 software (Stoelting, USA). To avoid pre-existing chamber bias ...
-
bioRxiv - Neuroscience 2023Quote: ... mounted in a Quintessential Stereotaxic Injector (Stoelting) controlled by a Motorized Lab Standard Stereotax (Harvard Apparatus) ...
-
bioRxiv - Neuroscience 2023Quote: Viral injections were carried out on a stereotactic apparatus (Stoelting, IL, USA) under isoflurane anesthesia ...
-
bioRxiv - Systems Biology 2023Quote: ... Explorative social behavior towards stranger mice was measured using ANY-mazeTM Video Tracking System software (Stoelting Co., IL, USA).
-
bioRxiv - Systems Biology 2023Quote: ... Exploration time was measured by a camera and ANY-mazeTM Video Tracking System software (Stoelting Co., IL, USA).
-
bioRxiv - Systems Biology 2023Quote: ... Movements were recorded using a camera and the tracking software ANY-mazeTM Video Tracking System software (Stoelting Co., IL, USA). Exploration towards the center of the field was considered a readout for reduced anxiety.
-
bioRxiv - Neuroscience 2023Quote: ... The Hamilton syringe and tubing was placed in a motorized injector (Stoelting Quintessential Stereotaxic Injector ...
-
bioRxiv - Neuroscience 2023Quote: ... Viral injections were performed through a glass pipette fitted in a motorized injector (Stoelting Quintessential Stereotaxic Injector ...
-
bioRxiv - Neuroscience 2023Quote: ... with a microinjector (Stoelting Co., Wood Dale, IL) attached to a stereotaxic micromanipulator (Narishige ...
-
bioRxiv - Neuroscience 2023Quote: ... baseline responses were measured using von Frey’s hairs (bending force range from 0.02-1.4 g, starting with 0.16g; Stoelting) after mice were placed on a wire grid without receiving any nociceptive stimulation for 2 hours ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... Tracking was analyzed offline with AnyMaze software (Stoelting, Wood Dale, IL), and the center zone was set as the inner 225 cm2 of the arena.
-
bioRxiv - Bioengineering 2023Quote: ... Fisher Chemical Inc.) and front fill the pipette with the virus using the injector (53311, Quintessential Stereotaxic Injector, Stoelting Co.). We injected Cacna1hChr2EYFP+/− animals with 500-750 nL of AAV2/9-CaMKIIa-GCaMP6f-P2A-nls-dTomato (Canadian Neurophotonics Platform Viral Vector Core Facility ...
-
bioRxiv - Neuroscience 2023Quote: ... Pulled glass capillaries were connected to a microinjection system (Stoelting Quintessential Stereotaxic Injector) to deliver viral vectors into the brain at a rate of 40–70 nL per minute ...
-
bioRxiv - Physiology 2023Quote: ... Body temperature was maintained at 37°C using a homeothermic blanket system (50300; Stoelting Co., USA) and mice were monitored using respiratory rate and toe pinch response tests throughout the procedure ...
-
bioRxiv - Neuroscience 2023Quote: ... with 1.00 mm punch (Stoelting Cat: 57397) was used to micro-dissect from hippocampal ...
-
bioRxiv - Neuroscience 2023Quote: ... 45-degree bevel needle on a stereotaxic apparatus (Stoelting). A single dose of AAV5-mCherry-Gfap-Cre (0.5 μL ...
-
bioRxiv - Neuroscience 2023Quote: Mice were anesthetized with isoflurane (1-5% isoflurane/1L O2/min) and placed on a double-armed stereotaxic frame (Stoelting). For acute viral injections ...
-
bioRxiv - Neuroscience 2023Quote: Animal behaviour was analysed from video tracks with the software ANY-maze Video Tracking System v.6.32 (Stoelting Co.).
-
bioRxiv - Neuroscience 2023Quote: ... animals were placed into a stereotaxic apparatus (Stoelting, UK).
-
bioRxiv - Neuroscience 2023Quote: ... and tracking and scoring were done using ANY-maze™ (Stoelting Co.) unless specified otherwise ...
-
bioRxiv - Neuroscience 2023Quote: ... Virus was injected into BLA bilaterally (0.5 μl per side) with a Hamilton microsyringe and a syringe pump (Stoelting Co.) at a rate of 0.1 μl/minute ...
-
bioRxiv - Neuroscience 2023Quote: ... A roughly ∼2-4mm craniotomy and 2-3 pilot holes were drilled using a micro drill (Stoelting). Stainless steel screws (000-120 ...
-
bioRxiv - Neuroscience 2023Quote: ... The surgical site was closed with clips (Stoelting, Wood Dale, IL) which were removed 7-10 days following surgery ...
-
bioRxiv - Neuroscience 2023Quote: ... tools were sterilized using a Dry Glass Bead Sterilizer (Stoelting, Cat#50287) and 100% anhydrous ethanol (Decon Laboratories ...
-
bioRxiv - Neuroscience 2023Quote: ... Rats were placed into the stereotaxic frame (David Kopf instruments, Tujunga, CA or Stoelting, Wood Dale, IL), given an injection of carprofen (5 mg/kg ...
-
bioRxiv - Neuroscience 2023Quote: ... placed into a stereotaxic apparatus (Stoelting Co, Wood Dale, IL), and maintained on a warm platform at 37°C for the whole duration of the anesthesia ...
-
bioRxiv - Neuroscience 2023Quote: ... placed into a stereotaxic apparatus (Stoelting Co, Wood Dale, IL), and maintained on a warm platform at 37°C for the whole duration of the anesthesia ...
-
bioRxiv - Neuroscience 2023Quote: ... Graft animals were injected with 20 × 106 GFP-labeled SVZ-NSCs suspended in DPBS (50 µL) using a Hamilton syringe (27G) and a micro-injector instrument (Stoelting, the USA) for 10 minutes [13] (Figure S4 C-D) ...
-
bioRxiv - Neuroscience 2023Quote: P1-3 pups were anaesthetized with isoflurane for juvenile injections and mounted on a stereotactic frame (Stoelting). Mice used for vTRAP/RNAseq experiments received six 150 nl injections at a speed of 10 nl/sec in S1 in the left hemisphere ...
-
bioRxiv - Neuroscience 2023Quote: ... −1.9 mm DV with the aid of a stereotaxic apparatus (Stoelting 51730). 8-10 weeks old male mice were anesthetized using ketamidol (7.5 mg/kg ...
-
bioRxiv - Neuroscience 2023Quote: ... and analyzed with ANY-maze™ tracking software (Stoelting Co., IL, USA).
-
bioRxiv - Cancer Biology 2023Quote: ... adult mice were anaesthetized by 4% isofluorane and then injected with a stereotactic apparatus (Stoelting) as previously described28 ...
-
bioRxiv - Neuroscience 2023Quote: ... were given an intraperitoneal (IP) injection of ketamine (50 mg/kg) and xylazine (5 mg/kg) and placed in a stereotaxic frame (Stoelting, Wood Dale, IL). AAV2/9-EF1a-DIO-EYFP viral particles (0.8μl ...
-
bioRxiv - Neuroscience 2023Quote: ... open field arenas and olfactory boxes recorded the animals’ behavior and was connected to the ANY-Maze software (Stoelting).
-
bioRxiv - Neuroscience 2023Quote: ... and the movement of the animals across the arena was recorded and tracked with the AnyMaze behavior tracking software for 5 minutes (Version 4.99M, Stoelting Europe, Dublin, Ireland, UK). The time spent on the open arms ...
-
bioRxiv - Neuroscience 2023Quote: ... Mice were given an intraperitoneal (IP) injection of ketamine (100 mg/kg) and xylazine (5 mg/kg) and placed in a stereotaxic frame (Stoelting). AAV1.CaMKIIa.hChR2(H134R)-eYFP.WPRE.hGH virus (Addgene ...
-
bioRxiv - Neuroscience 2023Quote: ... A camera was positioned above the foraging apparatus to generate a video that was used with ANY-maze software (30hz, Stoelting Co. Wood Dale, IL) to track the subject’s center point in real time.
-
bioRxiv - Neuroscience 2023Quote: ... We provided heat (Stoelting, 50300) while we delivered 2% isoflurane via a nose cone (Kent Scientific ...
-
bioRxiv - Neuroscience 2023Quote: ... Fiber optic cannulae were fixed to the skull using dental cement (Stoelting) mixed with carbon (Sigma-Aldrich ...
-
bioRxiv - Neuroscience 2023Quote: ... and using stereotaxic apparatus (Stoelting, Wood Dale, Illinois, United States). Throughout the entire surgery ...
-
bioRxiv - Neuroscience 2023Quote: ... and crosses into the center were measured using ANY-maze version 6.1 (Stoelting, Wood Dale, IL).
-
bioRxiv - Neuroscience 2023Quote: Stereotaxic injections were made in anesthetized adult mice of both sexes using a stereotaxic instrument (Stoelting Co., 51925) and a custom injection apparatus consisting of a hydraulic manipulator (Narishige ...
-
bioRxiv - Neuroscience 2023Quote: ... von Frey filaments (Touch Test Sensory Evaluator, Stoelting 58011) were pressed against the center of the plantar surface of the hindpaw until the filament buckled and held for a maximum of 3 s ...
-
bioRxiv - Neuroscience 2023Quote: Heat sensory thresholds (thermal hyperalgesia) were determined using the Hargreaves test (Ugo Basile Thermal Plantar test, Stoelting 55370) (Hargreaves et al. ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... The implant was secured to anchor screws and attached to the dry skull with dental cement (Stoelting, IL, USA). The ground wire was pinned to the channel on the EIB board ...
-
bioRxiv - Bioengineering 2023Quote: ... 5 – 10 bone screws (Stoelting, 51457) were placed on the circumference of the exposed calvarium in order to provide additional connections for electrical grounding as well as to secure subsequent cement (for the tissue retainment tests) ...
-
bioRxiv - Neuroscience 2023Quote: We measured mechanical sensory thresholds using von Frey filaments (Stoelting, 58011) and the SUDO up-down method (Bonin et al. ...
-
bioRxiv - Neuroscience 2023Quote: ... APP and WT mice were anesthetised with isoflurane and placed in a stereotaxic frame (Stoelting, IL, USA). An incision was made in the scalp to expose the skull and microscrews (Antrin ...