Labshake search
Citations for Becton, Dickinson and Company :
2901 - 2950 of 10000+ citations for Cell Isolation Optimizing System since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genomics 2020Quote: ... Treg cells (CD3+, CD4+, CD8-, CD25+), B cells (CD3-, CD19+), and monocytes (CD3-, CD14+) were sorted by FACSAria III (BD Pharmingen, San Diego, USA) directly into wash buffer for CUT&Tag ...
-
bioRxiv - Microbiology 2020Quote: ... human immune cell reconstitution in peripheral blood was measured by a fluorescence-activated cell sorter (FACS) Aria II flow cytometer (BD Biosciences, San Jose, CA) using antibodies against mCD45-APC ...
-
bioRxiv - Cell Biology 2019Quote: ... Cells were then further selected for GFP through flow cytometry using the FACS Aria Ilu High-Speed Cell Sorter (BD Biosciences (Franklin Lakes, NJ)) ...
-
bioRxiv - Immunology 2019Quote: ... Single-cell suspensions at 5 × 107 cells per ml were stained with a cocktail of fluorochrome conjugated human antibodies (BD Biosciences, San Jose, CA), anti-human IgG APC ...
-
bioRxiv - Immunology 2019Quote: ... Viable antigen-specific B cells (AqVd-CD14-CD16-CD3-CD19+ IgD-) were single-cell sorted with a BD FACSAria II-SORP (BD Biosciences, Mountain View, CA) into 96 well PCR plates and stored at −80°C for RT-PCR.
-
bioRxiv - Cell Biology 2021Quote: Cell cycle analysis was determined by flow cytometry (FACS) of propidium iodide (PI)- stained cells using BD FACS Calibur (BD Biosciences, San Jose, CA) as described earlier (Bacevic et al ...
-
bioRxiv - Cancer Biology 2020Quote: ... single cells were isolated and sorted into a 96 well plate using an Influx Special Order fluorescence activated cell sorter (BD Biosciences, San Jose, CA) at the Stanford Shared FACS Facility ...
-
bioRxiv - Physiology 2021Quote: ... islets were dispersed and dead cells were labeled using the LIVE/DEAD Fixable Aqua (405 nm) Dead Cell Stain Kit (BD Biosciences, San Jose, CA). EdU detection ...
-
bioRxiv - Molecular Biology 2021Quote: ... Stained peripheral blood samples were then lysed with red blood cell lysis buffer and absolute cell counts calculated using BD Liquid Counting Beads (BD Biosciences, San Jose, CA). Flow cytometry was performed using BD Fortessa II instrument (BD Biosciences ...
-
bioRxiv - Microbiology 2022Quote: ... The cells were collected to detect virus-infected cells via flow cytometry by using a BD LSR II flow cytometer (BD Biosciences, San Jose, CA)) at 48-h post-infection [45] ...
-
bioRxiv - Developmental Biology 2022Quote: ... Cells with CD41-GFPlow positive signal were subjected to fluorescence-activated cell sorting (FACS) with an influx cytometer (BD Biosciences, San Jose, CA, USA). Single-cell RNA sequencing was performed according to an adapted version of the SORT-seq (Muraro et al. ...
-
bioRxiv - Immunology 2022Quote: ... cells were filtered through a 70 µm cell strainer into FACS tubes and analyzed using a BD LSRFortessa (BD Biosciences, San Jose, CA, USA). Single cells were gated and tdTomato fluorescence was quantified in the PE channel using FACS Diva and Flowjo software.
-
bioRxiv - Biochemistry 2022Quote: ... either single GFP+ cells (to obtain clones 1 and 2) or 250 GFP+ cells (to obtain the pool) were sorted per well into a 96 well plate (BD FACSAria Fusion Cell Sorter). The two clones and the pool were expanded and the decreased ArgBP2 expression was confirmed by immunoblotting.
-
bioRxiv - Cancer Biology 2019Quote: ... 1x 105 cells of MT cells introduced retroviral vectors or 293T-CRISPR cells were suspended in a mixture of serum-free medium and Matrigel (BD Biosciences; 1:1 volume). The mixture was injected subcutaneously through a 26-gauge needle into the right dorsal areas of anesthetized NOD/SCID mice ...
-
bioRxiv - Genetics 2019Quote: ... and DNA profiles were evaluated using fluorescence-activated cell sorting with a FACSCalibur flow cytometer and Cell Quest software (BD Biosciences, San Jose, CA).
-
bioRxiv - Immunology 2020Quote: We labeled each group of NALT cells separately with the Sample-Tags from the BD Mouse Immune Single-Cell Multiplexing Kit (BD Biosciences, San Jose, CA), described in “Single Cell Labeling with the BD Single-Cell Multiplexing Kits” protocol ...
-
bioRxiv - Immunology 2021Quote: ... Spleen cells were isolated by scraping with slides in sterile PBS following red blood cell (RBC) lysis (Pharm LyseTM; BD Bioscience, San Jose, CA). Extracted LN were derived from the cervical and axillary chains exclusively.
-
bioRxiv - Synthetic Biology 2022Quote: ... cells from an empty vector and pCas9-sgRNAGFP transformed GM yeast cells were subjected to flow cytometry (BD Accuri™ C6 Plus Flow Cytometer). Cells were grown in 96-well format in YDP overnight and back diluted in SC media with 10µg/ml of doxycycline for ∼48 hrs ...
-
bioRxiv - Cancer Biology 2024Quote: ... selected cells were checked by measuring the number of cells expressing Venus using the BD AccuriTM C6 flowcytometer (BD Biosciences, Franklin Lakes, NJ, USA). The cells were 100% positive and thus expanded in cultured medium with 1 μg/mL of Puromycin.
-
bioRxiv - Immunology 2024Quote: ... The samples included for T cell phenotypic characterization were stained with a separate antibody cocktail containing T cell lineage markers (CD3-BV786 (BD, cat. #563799, clone SK7), CD4-BV650 (BD ...
-
bioRxiv - Microbiology 2023Quote: ... Bacteria were then separated from Cladocopium cells and debris by fluorescence-activated cell sorting on a Aria III/FACS DiVa 9 software (BD Biosciences, Franklin Lakes, NJ) equipped with a 70 μm nozzle and run at 70 psi ...
-
bioRxiv - Cell Biology 2023Quote: ... and mNeonGreen positive cells were sorted at the Stanford Shared FACS facility using a BD FACSAria II Cell Sorter (BD Biosciences, San Jose, CA) equipped with a blue 488 nm laser with a 502 nm long pass mirror and 525/50 nm filter.
-
bioRxiv - Plant Biology 2020Quote: ... followed by filtration through a cell strainer cup (BD falcon). Nuclei in the flow-through were then 1:4 diluted in sorting buffer (100 mM Tris ...
-
bioRxiv - Synthetic Biology 2021Quote: The cells were gated using DIVA and FlowJo (BD Bioscience). Within DIVA ...
-
bioRxiv - Synthetic Biology 2021Quote: ... The cells were analyzed using an Accuri C6 (BD Bioscience) flow cytometer with FL1 (533/30 nm ...
-
bioRxiv - Cancer Biology 2021Quote: ... Stained cells were analyzed with a BD FACSCalibur (BD Bioscience). The Flowjo software was used for data analyses.
-
bioRxiv - Biophysics 2020Quote: ... cells were plated onto coverslips coated with Matrigel (BD Biosciences).
-
bioRxiv - Cancer Biology 2021Quote: ... cells were stained with Fixable Viability Stain (FVS) 780 (BD Biosciences ...
-
bioRxiv - Cancer Biology 2021Quote: ... and filtered through a 70 μm cell strainer (BD Biosciences). Cells were then plated in 96-well Costar ultra-low attachment plate (Corning ...
-
bioRxiv - Cancer Biology 2021Quote: ... Cell suspensions were analyzed by LSR II Fortessa (BD Biosciences) and the results were evaluated with the FlowJo software (version 10.0.8 ...
-
bioRxiv - Cancer Biology 2021Quote: ... cells were analyzed using a FACS Canto II (BD Bioscience).
-
bioRxiv - Cancer Biology 2021Quote: ... Cells were sorted on a BD FACS Aria (BD Biosciences) with a 100 μm nozzle ...
-
bioRxiv - Systems Biology 2020Quote: ... Cells were analyzed on an LSR II instrument (BD Biosciences).
-
bioRxiv - Microbiology 2020Quote: ... Cells were permeabilized with PermWash buffer (#554723, BD Biosciences, Germany), incubated with the primary antibody anti-N at 4°C for 30 min ...
-
bioRxiv - Cell Biology 2020Quote: ... This cell suspension was mixed 1:1 with matrigel (BD) and 100 μl were injected subcutaneously into a minimum of six male immunodeficient NOD/ShiJic-scid Jcl (NOD-SCID ...
-
bioRxiv - Immunology 2021Quote: ... cells were processed using the Fixation/Permeabilization kit from BD Biosciences (BD Cytofix/Cytoperm ...
-
bioRxiv - Cell Biology 2020Quote: ... Cells were sorted using a FACSAriaIII (Becton Dickinson, BD Biosciences) equipped with 488nm ...
-
bioRxiv - Cell Biology 2020Quote: ... cells were analyzed on a flow cytometer (LSR II; BD) equipped with 535-nm lasers ...
-
bioRxiv - Cell Biology 2020Quote: ... Single cells were sorted on the FACSAria Fusion (BD Biosciences) as doublet excluded ...
-
bioRxiv - Cell Biology 2020Quote: ... Cell ploidy was analyzed with a FACSCanto II (BD Biosciences) as described by Duncan et al ...
-
bioRxiv - Cell Biology 2020Quote: ... cells were fixed with BD Cytofix Fixation Buffer (BD Biosciences). After fixation cells were gently washed with PBS and permeabilized with 0.2% TritronX-100 (Sigma ...
-
bioRxiv - Cell Biology 2020Quote: ... the transfected cells were FACS sorted (FACSAria Fusion (BD Biosciences)) and clonally expanded ...
-
bioRxiv - Immunology 2021Quote: ... cells were also fixed/permeabilized using Cytofix/Cytoperm (BD Biosciences) and stained with anti-TNFα–BV421 (clone MAb11 ...
-
bioRxiv - Immunology 2021Quote: ... Cells were acquired on a FACS Canto II (BD Biosciences). The data was analyzed using FlowJo (TreeStar software ver ...
-
bioRxiv - Immunology 2021Quote: ... Cells were acquired using a FACSVerse flow cytometer (BD Biosciences) or a Beckman Coulter Gallios Flow Cytometer and data were analyzed using Flowjo or Kaluza ...
-
bioRxiv - Genetics 2021Quote: ... cells were analysed by flow cytometry using Cytoflex (BD Biosciences). Data analysis was performed using FlowJo software (BD Biosciences) ...
-
bioRxiv - Developmental Biology 2021Quote: ... Cell sorting was performed using an Aria II (BD Biosciences). Sorted cells were collected in RLT buffer (Qiagen ...
-
bioRxiv - Microbiology 2019Quote: ... Samples were analyzed using a fluorescence-activated cell sorter (BD FACSCalibur ...
-
bioRxiv - Immunology 2021Quote: ... Cell staining was analyzed using LSR Fortessa flow cytometers (BD) and FlowJo software (v10) ...
-
bioRxiv - Immunology 2021Quote: ... Cells were sorted using a FACSAria Fusion cytometer (BD, France).