Labshake search
Citations for NanoTemper :
51 - 100 of 220 citations for Recombinant Human PPAR gamma Protein His tag since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2021Quote: ... His-Cdc42 was labeled following the instructions of the MO-L001 Monolith NT Protein Labeling Kit RED – NHS (NanoTemper Technologies). Labelled protein concentration in the binding reactions was 10 nM while compounds concentration was either 50 or 100 μM ...
-
bioRxiv - Molecular Biology 2022Quote: ... we evaluated the interaction of recombinant PfPHB1 and PfPHB2 proteins using Monolith NT.115 instrument (NanoTemper Technologies, Munich, Germany). Thermophoretic movement of a fluorescently labelled protein is measured by monitoring the fluorescence distribution ...
-
bioRxiv - Biochemistry 2024Quote: The human proteasomes were labelled using the Monolith NT™ Protein Labeling Kit (NanoTemper) and exchanged to reaction buffer (50 mM Tris-HCl [pH 7.5] ...
-
bioRxiv - Biochemistry 2024Quote: The binding affinity of each recombinant TrK13 protein for heme was evaluated by MST analysis using the Monolith NT.115 instrument (NanoTemper Technologies). The recombinant TrK13 proteins (50 nM ...
-
bioRxiv - Microbiology 2024Quote: ... and the NHS-red-tag kit (Nanotemper, Germany) was used to label ConA (Sigma ...
-
bioRxiv - Biochemistry 2024Quote: ... containing 6.25 μM of His-tagged PyrE labeled with RED dye (Nanotemper Technologies, USA), with an equal volume of the respective ligand solution ...
-
bioRxiv - Biophysics 2020Quote: ... Sb23 was labelled via the His6-tag with RED-tris-NTA dye (NanoTemper Technologies) in PBS-T (10 mM phosphate ...
-
Cryo-EM structure of a eukaryotic zinc transporter at a low pH suggests its Zn2+-releasing mechanismbioRxiv - Biochemistry 2022Quote: ... by staining His-tagged xtZnT8 with the RED-Tris-NTA 2nd Generation dye (NanoTemper Technologies, Germany). For Zn2+ titration ...
-
bioRxiv - Biochemistry 2024Quote: ... coli was labeled using the Monolith Lys-Tag Labeling Kit RED-NHS second generation (NanoTemper Technologies), according to the manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2024Quote: Site-specific labelling of His-tagged BRISC was performed using a RED-tris-NTA 2nd generation labelling kit (NanoTemper Technologies) in buffer containing 25 mM HEPES pH 7.5 ...
-
bioRxiv - Biochemistry 2024Quote: ... 100 nM His-BRISC was incubated with 25 nM RED-tris-NTA dye and prepared according to the recommended protocol from NanoTemper. To measure the affinity of the interaction between BRISC and SHMT2 ...
-
bioRxiv - Microbiology 2024Quote: The protein-DNA and protein-protein interaction were assayed by microscale thermophoresis (MST) using Monolith NT.115 (NanoTemper Technologies, Germany) as described earlier (Su et al ...
-
bioRxiv - Microbiology 2021Quote: Proteins were labeled using the Monolith NT Protein Labeling Kit RED (NanoTemper Technologies) according to the manufacturer’s protocol and using a buffer consisting of 20 mM HEPES ...
-
bioRxiv - Molecular Biology 2021Quote: ... EMCV 2A protein was labelled using the Protein Labelling Kit RED-Maleimide (NanoTemper Technologies) according to the manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2024Quote: Target proteins were fluorescently labeled using the Protein Labeling Kit RED-NHS (NanoTemper Technologies). Labeling reaction was performed following the manufacturer’s instructions with 10 μM protein ...
-
bioRxiv - Immunology 2024Quote: The binding interaction between BTN2A2-His and CD45RO-Fc was measured by Microscale Thermophoresis (MST) using the Monolith NT.115 instrument (Nanotemper Technologies, München, Germany) as described (Wienken et al. ...
-
bioRxiv - Cell Biology 2020Quote: Protein-protein interactions were monitored by MST using a Monolith NT.115 instrument (Nanotemper Technologies). His6-MyoVa GTD was labeled using RED-NHS 2nd Generation (Amine Reactive ...
-
bioRxiv - Cancer Biology 2023Quote: ... EED and JMJD3 proteins were labeled with Protein Labeling kit RED-NHS (NanoTemper, MO-L001). At least three independent experiments were performed for each binding reaction.
-
bioRxiv - Biophysics 2024Quote: The melting temperatures (Tm) of recombinant VDAC were determined by native tryptophan fluorescence using a Tycho Differential Scanning Fluorometer (Nanotemper). VDAC samples were diluted to 1mg/ml in 25 mM HEPES at pH 7.4 ...
-
bioRxiv - Biochemistry 2022Quote: Protein–protein interactions were monitored by microscale thermophoresis using a Monolith NT.115 instrument (Nanotemper Technologies). His LRRK2 Armadillo (1-552) ...
-
bioRxiv - Biochemistry 2023Quote: Protein–protein interactions were monitored by microscale thermophoresis using a Monolith NT.115 instrument (NanoTemper Technologies). His LRRK2 Armadillo (1–552 ...
-
bioRxiv - Biophysics 2023Quote: ... where the protein was labelled with Monolith Protein labelling kit RED-NHS (NanoTemper Technologies, Munich, Germany). In the binding assay ...
-
bioRxiv - Microbiology 2022Quote: ... Protein-protein interactions were analyzed at 20°C by MST on a Monolith NT.115 (NanoTemper technologies) using standard capillaries ...
-
bioRxiv - Physiology 2023Quote: ... Purified OsABG protein was labeled using the protein labeling kit Red-NHS 2nd generation (MO-L011, Nanotemper) which dyes primary lysine residues in the protein ...
-
bioRxiv - Microbiology 2023Quote: ... Proteins were fluorescently labeled using the RED-Maleimide 2nd Generation Protein Labeling Kit (NanoTemper Technologies GmbH, Germany) as recommended by the manufacturer ...
-
bioRxiv - Cancer Biology 2021Quote: Binding of purified recombinant KIX with fluorescein isothiocyanate (FITC)-conjugated peptides was measured by microscale thermophoresis using the Monolith NT.115 (NanoTemper Technologies). Assays were conducted in 50 mM sodium phosphate ...
-
bioRxiv - Molecular Biology 2023Quote: The affinity between RNA and protein and between proteins was measured by MST on a Monolith NT.115 (NanoTemper, Germany). Replicates represent individual measurements performed on different days using proteins from the same prep ...
-
bioRxiv - Biochemistry 2023Quote: ... Purified GST fusion protein were fluorescently labeled using the Monolith series Protein Labeling Kit RED-NHS 2nd Generation (Nanotemper, MO-L011) according to manufacturer’s instructions ...
-
bioRxiv - Microbiology 2021Quote: ... Phr2 and Pga4 proteins and Bull Serum Albumin (BSA) were labeled using the Monolith™ RED-NHS Protein Labeling Kit (NanoTemper Technologies) according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2023Quote: ... The protein interaction was measured in standard capillaries (NanoTemper), 100% excitation power and medium or high MST power (IR-laser intensity) ...
-
bioRxiv - Immunology 2022Quote: Protein-protein interactions were analyzed via microscale thermophoresis on a Monolith NT.115 instrument equipped with green/red filters (NanoTemper Technologies, Munich, Germany). Measurements were performed at 25°C at both 40% and 80% MST power ...
-
bioRxiv - Biochemistry 2020Quote: ... Thermally-driven protein unfolding was monitored in Tycho quartz capillaries (Nanotemper) using a Tycho NT.6 instrument (Nanotemper) ...
-
bioRxiv - Microbiology 2022Quote: ... Protein quality was verified using a Tycho NT.6 system (NanoTemper) and ACE2 activity assay kit (SensoLyte ...
-
bioRxiv - Biophysics 2024Quote: ... Protein Labeling Kit RED-NHS 2nd Generation was purchased from NanoTemper Technologies (München ...
-
bioRxiv - Biophysics 2024Quote: ... CRBN protein was labelled with RED-Maleimide 2nd Generation dye (NanoTemper) optimized for degree-of-labeling of 1:1 molar ratio calculated by nanodrop ...
-
bioRxiv - Cell Biology 2023Quote: ... Monolith RED-NHS 2nd generation protein labeling kit (NanoTemper Technologies GmbH) was used to label LIAS and ...
-
bioRxiv - Immunology 2022Quote: ... Protein samples (0.1 mg/mL) were loaded into glass capillaries (NanoTemper) and then subjected to a temperature gradient from 20 to 95 °C at a heating rate of 1 °C per min ...
-
bioRxiv - Immunology 2023Quote: ... Protein samples (0.1 mg/mL) were loaded into glass capillaries (NanoTemper) and then subjected to a temperature gradient from 20 to 95°C at a heating rate of 1°C per min ...
-
bioRxiv - Biophysics 2021Quote: ... or Monolith NT™ (Protein Labeling Kit Blue-NHS, NanoTemper GmbH, Germany). The labeling was achieved by incubating 115 μM of protein and 350 μM of dye (465 μl reaction volume ...
-
bioRxiv - Biochemistry 2024Quote: ... the proteins were labeled with a RED-NHS Labeling Kit (NanoTemper Technologies) according to the manufacturer’s instructions ...
-
A pectin-binding peptide with a structural and signaling role in the assembly of the plant cell wallbioRxiv - Plant Biology 2023Quote: ... protein quality was assessed using a Tycho NT.6 (NanoTemper, Munich, Germany). Labeled protein was dissolved in MST buffer (50mM Tris-HCl pH 7.8 ...
-
bioRxiv - Microbiology 2023Quote: Protein thermostability was evaluated with a Prometheus NT.48 instrument (NanoTemper Technologies). Proteins at a concentration of 1 mg/mL were loaded to the grade capillaries and the intrinsic fluorescence signal was measured while temperature was increased by 1°C/min ...
-
bioRxiv - Biochemistry 2023Quote: ... the proteins were labeled with a RED-NHS Labeling Kit (NanoTemper Technologies) according to the manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2023Quote: ... Ten microliters of proteins were loaded into a capillary (PR-C002, Nanotemper) and thermal denaturation was recorded using a 1 °C/min ramp from 20 to 95 °C ...
-
bioRxiv - Biochemistry 2023Quote: ... Monolith protein labeling kit RED-NHS 2nd generation was purchased from NanoTemper Technologies (Munich ...
-
bioRxiv - Immunology 2024Quote: Protein thermostability was evaluated with a Prometheus NT.48 instrument (NanoTemper Technologies). Proteins at a concentration of 1 mg/mL were loaded to the grade capillaries and the intrinsic fluorescence signal was measured while temperature was increased by 1 °C/min ...
-
bioRxiv - Biochemistry 2024Quote: ... Protein unfolding was monitored using a Prometheus NT.48 instrument (NanoTemper Technologies) by measuring absorbance at 330 and 350 nm (with 20% excitation) ...
-
bioRxiv - Biochemistry 2022Quote: Protein thermal stability was measured using nanoDSF on a Prometheus panta instrument (NanoTemper) (39) ...
-
bioRxiv - Biochemistry 2020Quote: ... 10μL of the diluted protein was loaded into NanoDSF Grade Standard Capillaries (NanoTemper) and melting temperatures were determined using a Prometheus NT4.8 NanoDSF instrument according to the manufacturer’s instruction ...
-
bioRxiv - Biochemistry 2022Quote: ... 150 mM NaCl using the Monolith NT Protein Labelling Kit RED (NanoTemper Technologies) according to the manufacturer’s protocol ...