Labshake search
Citations for Labcyte :
1 - 50 of 76 citations for Endothelin 1 ET 1 ELISA Kit 1 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... 2.5 or 7.5 nl of a 10 mM stock of the compounds dissolved in DMSO were arrayed and dispensed into square flat-bottom black 384-well plates containing 1 µl DMSO/well using an Echo 550 (Labcyte), before being sealed and stored at −80°C.
-
bioRxiv - Biochemistry 2021Quote: ... 2.5 or 7.5 nl of a 10 mM stock of the compounds dissolved in DMSO were arrayed and dispensed into square flat-bottom black 384-well plates containing 1 μl DMSO / well using an Echo 550 (Labcyte), before being sealed and stored at −80°C.
-
bioRxiv - Cancer Biology 2020Quote: ... compounds were first stamped in triplicate into 384 well plates for a final concentration of 1 μM using an Echo Acoustic Dispenser (Labcyte). Cells and media were then dispensed into plates using a WellMate (Thermo Fisher ...
-
bioRxiv - Cancer Biology 2019Quote: ... Compounds were stamped into 384 well plates for a final concentration of 1 μM using an Echo Acoustic Dispenser (Labcyte). Cells were then plated at a density of 2,000 cells/well using a WellMate (ThermoFisher ...
-
bioRxiv - Immunology 2020Quote: ... and serum was pre-diluted 1:20 in sample buffer and transferred to antigen-coated 1536-well assay plates using acoustic dispensing technology (Labcyte ECHO 555) with serial dilutions ranging from 1:5–1:640 (mucosal samples ...
-
bioRxiv - Cancer Biology 2022Quote: ... were stamped in triplicate into 384-well plates at a final concentration of 1 μM using an Echo Acoustic Dispenser (Labcyte, Indianapolis, IN, USA). Cells and media were subsequently dispensed into plates using a WellMate (Thermo Fisher ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... transferred to daughter plates using an Echo acoustic plate reformatter (Labcyte, Sunnyvale, CA) and diluted in Assay Buffer to a 2X final concentration ...
-
bioRxiv - Immunology 2021Quote: ... Serum or plasma samples were diluted in sample buffer (1% milk in PBS-T) and dispensed using acoustic dispensing technology employing the ECHO 555 (Labcyte). Thereby ...
-
bioRxiv - Genomics 2021Quote: ... 10 nl of 1 uM barcoded DRUG-seq RT primers were then dispensed into each well using an Echo 555 Liquid Handler (Labcyte). Plates were sealed (BioRad ...
-
bioRxiv - Neuroscience 2021Quote: ... compatible 384-well LDV plates (Labcyte). For the primary screen ...
-
bioRxiv - Biochemistry 2020Quote: ... at concentration ranges of 1 nM to 100 M using a Labcyte Echo 555 Omics acoustic liquid handler (Labcyte, Sunnyvale, CA), with DMSO being back-added to a final concentration of 0.1% ...
-
bioRxiv - Synthetic Biology 2019Quote: ... Reactions were distributed by electronic pipette and TetR dilutions were distributed into cell-free reactions in volumes of 1 µL using an Echo 525 acoustic liquid handler (Labcyte Inc.).
-
bioRxiv - Synthetic Biology 2022Quote: ... 384-well plates were prepared for screening by dispensing 1 mM IPTG and 0.5 mM small molecules using an acoustic liquid handler (Labcyte Echo 550). This scheme will generate four data points per variant ...
-
bioRxiv - Biochemistry 2024Quote: ... 5 nL of 1 mM MLN4924 in DMSO was added to every well using an acoustic liquid handler (Labcyte Echo 500), and the plates were returned to the incubator for an additional 17 hours ...
-
bioRxiv - Synthetic Biology 2020Quote: ... We used a PP source plate (Labcyte) for acceptor plasmids (AP ...
-
bioRxiv - Biochemistry 2019Quote: ... Low volume dispensing plates (Labcyte #LP-0200) were assembled using an Agilent BioCell work station (Santa Clara ...
-
bioRxiv - Biochemistry 2019Quote: ... Low volume dispensing plates (Labcyte #LP-0200) were assembled using an Agilent BioCell work station (Santa Clara ...
-
bioRxiv - Synthetic Biology 2020Quote: ... For L1 reactions an LDV source plate (Labcyte) with all necessary L0 plasmids was needed ...
-
bioRxiv - Bioengineering 2020Quote: ... compatible 384-well source plate (Labcyte PP-0200). A 40 mM cumate solution (40% ethanol ...
-
bioRxiv - Developmental Biology 2024Quote: ... Compounds for screening were picked from source plates and transferred to assay plates using an Echo 555 acoustic transfer liquid handler (Labcyte/Beckman). Each drug was tested at a concentration of 1 µM directly added in the Hashimoto plate ...
-
bioRxiv - Cancer Biology 2022Quote: Dose-response experiments were performed as previously described.18;33 Compounds (Supplementary Table 1) were pre-printed in 384-well cell culture microplates using the Echo 550 liquid handler (Labcyte Inc., San Jose, CA, USA). Each compound was tested at five different concentrations in ten-fold increments ranging from 1 nM - 10000 nM (0.1 nM - 1000 nM for copanlisib) ...
-
bioRxiv - Biochemistry 2020Quote: ... assay plates using an Echo 525 Liquid Handler (Labcyte). Binding assays were conducted in a final volume of 16 μl with 12.5 nM Nsp3 Mac1 domain ...
-
bioRxiv - Cancer Biology 2019Quote: ... Plate and liquid handling were performed using Echo550 (Labcyte), Viaflo 384 (Integra Bioscience ...
-
bioRxiv - Biophysics 2022Quote: ... assay plates using an Echo 525 liquid handler (Labcyte). Binding assays were conducted in a final volume of 16 μl with 12.5 nM NSP3 Mac1 protein ...
-
bioRxiv - Biochemistry 2021Quote: ... Plates were created using an Echo liquid handling robot (Labcyte) and immediately sealed and frozen at −20 °C ...
-
bioRxiv - Biochemistry 2021Quote: ... were distributed in 24 plates using an Echo 550 (Labcyte) across column 3 to column 22 ...
-
bioRxiv - Neuroscience 2023Quote: Plate and liquid handling were performed using Echo550 (Labcyte, USA), Viaflo 384 (Integra Biosciences ...
-
bioRxiv - Biochemistry 2020Quote: ... and placed in a 384-well Echo source plate (Labcyte PP0200). Using a LabCyte Echo ...
-
bioRxiv - Molecular Biology 2022Quote: ... Plate and liquid handling were performed using Echo®550 (Labcyte), MultiFlo Dispenser (Integra) ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... assay plates were dosed using an Echo® 655T acoustic dispenser (Labcyte) from the appropriate compound stock to perform a 1000-fold dilution ...
-
bioRxiv - Biochemistry 2023Quote: ... Compounds were added to the assay plate by an Echo 550(Labcyte) and incubated with the cells for 72 hours in humidified incubators with 5% CO2 at 37 °C ...
-
bioRxiv - Neuroscience 2023Quote: ... were plated in 384-well low dead volume plates (Labcyte, #LP-0200). Using the ECHO acoustic liquid handler (Labcyte ...
-
bioRxiv - Cancer Biology 2022Quote: ... The peptide-buffer mixtures were dispensed and reformatted into 384 well plates (Labcyte) at a volume of 47.5 μl per well ...
-
bioRxiv - Biophysics 2021Quote: ... then transferred to 384-well Echo Qualified source-plates (Labcyte Inc, Sunnyvale, CA, USA). Assay plates were prepared by transferring 5 nL of the 10 mM compound stocks in columns 3-22 and 27-46 ...
-
bioRxiv - Cancer Biology 2023Quote: ... For 2D combination studies in 384-well plates the Echo 550 liquid handler (Labcyte) was programmed to add drug.
-
bioRxiv - Bioengineering 2020Quote: ... This transfer sheet was uploaded into and run through the Echo Plate Reformat software (Labcyte). After liquid transfer was completed by the Echo ...
-
bioRxiv - Cancer Biology 2022Quote: Compounds were dispensed in 384-well plates using an ECHO® 555 liquid handler (Labcyte) and sealed ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... The assay ready plate containing compounds was prepared using an Echo acoustic dispensing instrument (Labcyte) that had 90 nL aliquot of each diluted sample per well ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... dispensed into each well of the plate using an Echo 550 acoustic dispenser from Labcyte, Inc ...
-
bioRxiv - Synthetic Biology 2021Quote: ... As source plates we used ECHO® qualified 384-Well PP 2.0 Plus Microplates from Labcyte and used AQ_GP as the liquid class (AQueous solution ...
-
bioRxiv - Cell Biology 2020Quote: ... an 11-point dilution series of compounds were dispensed into black 384-well plates using an Echo (Labcyte). USP30 ...
-
bioRxiv - Systems Biology 2021Quote: ... oligonucleotides (Integrated DNA Technology) were arrayed into 96 well plates using an acoustic liquid handling robot (Echo LabCyte) and stored at −20°C ...
-
bioRxiv - Systems Biology 2020Quote: ... to a 384 well plate and an equal volume of each of them pooled by Echo (Echo550, Labcyte). The pool was concentrated by MinElute column (Quiagen ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... The serially diluted compounds were transferred to low dead volume Echo plates (Labcyte, Sunnyvale, CA, Cat# LP-0200). The test compounds were then spotted to 384-well assay plates (Greiner ...
-
bioRxiv - Cancer Biology 2023Quote: ... different volumes of stock solutions were plated into 384 well plates by using ECHO 550 acoustic dispenser (Labcyte) to generate the final concentration of interest for each drug ...
-
bioRxiv - Cell Biology 2023Quote: Drug dosing on 384-well plates was performed using an Echo acoustic liquid handler and corresponding software (Labcyte). Screened compounds were selected from the appropriate chemical library plates containing Cloud library (Enamine ...
-
bioRxiv - Genomics 2019Quote: ... 1.25 µL of sample containing 50 ng/µL of cDNA and 1.75 µL of Master mix containing 0.85 µM of primers were distributed in multiwell plates by the Echo 525 liquid handler (Labcyte). After an enzyme activation step of 95°C for 15 min ...
-
bioRxiv - Microbiology 2020Quote: ... were used as the library source plates to support acoustic transfer with an Echo 555 Liquid Handler (Labcyte Inc.). Compounds not soluble in DMSO were plated in water (129 compounds) ...
-
bioRxiv - Microbiology 2021Quote: ... corresponding to final concentrations of 0.1 to 50 µM with a constant DMSO concentration of 0.5% were distributed in 384-well white opaque plates using an Echo 555 Liquid Handler (Labcyte). Transfected HEK-293T cells were trypsinized at 6 hpt and distributed in the 384-well plates (2×104 cells per well in 50 µL) ...
-
bioRxiv - Microbiology 2020Quote: ... Compounds were dispensed to generate assay ready plates using an Access Laboratory Workstation with dual Echo 655 dispensers (Labcyte). Each plate was sealed with a peel-able aluminium seal ...