Labshake search
Citations for Cell Biolabs :
1 - 50 of 173 citations for Onion Yellow Dwarf Virus OYDV PCR Kits since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2023Quote: ... Virus was titered using the QuickTiter™ Lentivirus Titer Kit (Cell Biolabs, Inc) following manufacturer conditions.
-
bioRxiv - Cancer Biology 2024Quote: ... as described.25 Virus titers were determined with the QuickTiter Adenovirus Immunoassay kit (Cell Biolabs).20
-
bioRxiv - Cell Biology 2021Quote: ... Virus titer was measured using the QuickTiter™ Lentivirus Titer Kit (Cell Biolabs, VPK-107-T) according to the manufacturer’s instructions.
-
bioRxiv - Cell Biology 2023Quote: ... and the virus titer was measured based on the titer of the viral protein p24 with QuickTiterTM Lentivirus Titer Kit (Cell Biolabs) following the manufacturer’s instructions.
-
bioRxiv - Microbiology 2024Quote: ... Virus yields were then determined by p30 (CA) ELISA using the QuickTiter MuLV Core Antigen Elisa Kit (Cell Biolabs INC, VPK-156) as per the manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2021Quote: ... Virus was produced by transfecting Platinum-E retroviral packaging cells (Cell Biolabs) according to the manufacturer’s protocol ...
-
bioRxiv - Immunology 2024Quote: ... The virus was produced with Plat-E cells (Cell Biolabs RV-101) and transfected with 20µg of MMLV DNA ...
-
bioRxiv - Neuroscience 2020Quote: AAV virus was made using the AAV-DJ Helper Free Packaging System (Cell Biolabs) using published protocols95 ...
-
bioRxiv - Neuroscience 2021Quote: Adeno-associated virus (AAV) was generated using the AAV-DJ Helper Free system (Cell Biolabs) as published previously9,27 ...
-
bioRxiv - Cell Biology 2022Quote: ... For production of virus for mouse cells platinum E cells (Cell Biolabs, Cat#RV-101) were transfected ...
-
bioRxiv - Cancer Biology 2020Quote: ... The virus packaging cell lines Platinum-E (Plat-E,Cell Biolabs, Inc, San Diego, CA, USA) and GPp210-GFP61 were kept in DMEM (Sigma ...
-
bioRxiv - Neuroscience 2024Quote: Virus was produced using Helper Free Expression System and the 293AAV cell line (Cell Biolabs, Inc.). The cell pellet was lysed by alternating freeze thaw cycles in ethanol/dry ice bath three times ...
-
bioRxiv - Cell Biology 2024Quote: ... The recombinant virus was prepared by transfecting the pBABE-Puro-hTERT retroviral vector (Cell Biolabs Inc.) into Plat-E retroviral packaging cells (Cell Biolabs Inc. ...
-
bioRxiv - Biochemistry 2021Quote: ... The plasmid expressing the VSV-G (vesicular stomatitis virus glycoprotein) was purchased from Cell Biolabs (pCMV-VSV-G, Part No. RV-110). The lentiviral plasmid used to generate the HEK-293T stable cell lines expressing the human ACE2 gene (GenBank ID NM_021804 ...
-
bioRxiv - Bioengineering 2022Quote: ... The envelope vector expressing VSV-G (vesicular stomatitis virus glycoprotein) was obtained from Cell Biolabs (pCMV-VSV-G, Part No. RV-110). To generate the expression plasmid for D614G mutant of SARS-CoV-2 Spike (S ...
-
bioRxiv - Biochemistry 2021Quote: ... while the plasmid expressing VSV G (vesicular stomatitis virus glycoprotein) was purchased from Cell Biolabs (pCMV-VSV-G, Part No. RV-110). The HDM-IDTSpike-fixK plasmid was employed as a template for site-directed mutagenesis to generate the expression plasmid for the D614G mutant of SARS-CoV-2 spike protein ...
-
bioRxiv - Bioengineering 2021Quote: ... Each variant was pooled and the titer of the virus was determined by quantitative PCR relative to a standard curve using ITR-binding primers or by using a QuickTiter AAV Quantitation Kit (Cell Biolabs). The relative titer of each variant in the pooled AAV library was confirmed by Illumina MiSeq sequencing (primer sequences are provided in Table S1).
-
bioRxiv - Neuroscience 2021Quote: Fibcd1 constructs were packaged into virus by CaCl2 transfecting 70-80% confluent 10cm2 plate of Platinum-E (PlatE) HEK 293T cells (Cell Biolabs #RV-101) with 10µg Fibcd1 construct and 2µg gag/pol plasmid ...
-
bioRxiv - Molecular Biology 2021Quote: ... and co-transfected with pAAV-DJ vector and pAAV-Helper vector into HEK 293T cells to generate recombinant adeno-associated virus expressing Mir20b or anti-Mir20b according to the manufacturer’s protocol (Cell Biolabs, San Diego, CA). The AAVs were purified with AAVpro® Purification Kit (Takara Bio ...
-
bioRxiv - Immunology 2020Quote: Adenosine Assay Kit (Cell Biolabs Inc.);
-
bioRxiv - Pharmacology and Toxicology 2022Quote: The Cell Contraction Assay kit (Cell Biolabs) was used for gel contraction (39) ...
-
bioRxiv - Molecular Biology 2023Quote: ... and AP Sites Quantitation Kit (Cell Biolabs), respectively ...
-
bioRxiv - Molecular Biology 2024Quote: ... The OxiSelect Comet Assay Kit (Cell Biolabs) was used according to the manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2024Quote: ... a Taurine Assay Kit (Cell Biolabs, Inc.) was used ...
-
bioRxiv - Bioengineering 2024Quote: The Cas9 ELISA kit (Cell BioLabs Inc.) and lenti-X p24 Rapid titer kit (Takara Biosciences ...
-
bioRxiv - Biochemistry 2022Quote: ... The mouse Mafa coding sequence was amplified by PCR and subcloned into pAAV-MCS (VPK-410, Cell Biolabs. Inc.).
-
bioRxiv - Cancer Biology 2022Quote: ... was used as a template to amplify the MPI gene by PCR using a primer set (Supplementary Table S1) and the PCR products were cloned into pMXs-Neo retroviral expression vector (RTV-011, Cell Biolabs) to yield pMXs-Neo-hMPI by using In-Fusion HD Cloning Kit (639648 ...
-
bioRxiv - Genomics 2020Quote: The Radius Cell Migration Assay kit (Cell Biolabs, Inc) was used for the gap closure assay ...
-
bioRxiv - Genetics 2022Quote: ... nuclear and cytosolic fractionation kit (Cell Biolabs: AKR-171) was used ...
-
bioRxiv - Cell Biology 2024Quote: ... the 96-Well Cellular Senescence Assay Kit (Cell Biolabs) was used ...
-
Inhibition of p38-MK2 pathway enhances the efficacy of microtubule inhibitors in breast cancer cellsbioRxiv - Cancer Biology 2024Quote: CytoSelect 24-well cell invasion assay kits (Cell Biolabs) utilizing basement membrane-coated inserts were used according to the manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2022Quote: ... The FLAG-tagged mouse Pdx1 coding sequence was amplified by PCR and subcloned into a pMXs-Neo Retroviral vector (RTV-011, Cell Biolabs, Inc.). pGL3-basic-MafA plasmid (−10427/+22 from transcription start site ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... was evaluated using OxiSelect™ TAC Assay Kit (Cell Biolabs, Inc. ...
-
bioRxiv - Systems Biology 2024Quote: ... Tyrosine was quantified with a colorimetric kit (Cell Biolabs, #MET5073), phenylalanine was quantified with a fluorometric kit (bioAssay Systems ...
-
bioRxiv - Cancer Biology 2024Quote: CytoSelect BrdU Competitive ELISA kit (CBA-5098; Cell Biolabs, Inc) was used to confirm BrdU incorporation in the H:H and H:L fractions collected after Caesium Chloride gradient ultracentrifugation ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Serum free fatty acids were measured using kits from Cell Biolabs, Inc (San Diego ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... we used a GFP ELISA Kit (AKR-121, Cell Biolabs Inc.) which can detect GFP ...
-
bioRxiv - Biophysics 2020Quote: LDH leakage assay (CytoSelect LDH cytotoxicity assay kit, CBA-241, Cell Biolabs) was performed to assess the membrane integrity of the cells grown on the substrates ...
-
bioRxiv - Cancer Biology 2020Quote: ... and titer was calculated using QuickTiter lentivirus Titer Kit (Cell Biolabs, Inc.). Virus was added to MIA PaCa-2 and PANC-1 cells with 10ug/ml polybrene at a MOI of 0.3 and selected with puromycin (3μg/ml ...
-
bioRxiv - Biophysics 2022Quote: Lipid concentrations were determined with a Lipid Quantification Kit (Cell Biolabs, Inc). 15 µl of analyte or of a DOPC standard were added to 150 µl of 18 M H2SO4 and successively incubated at 90°C for 10’ and at 4 °C for 5’ ...
-
bioRxiv - Cancer Biology 2023Quote: ... AP sites were quantified using AP sites quantification kit (Cell Biolabs, Inc.) according to the manufacturers instructions ...
-
bioRxiv - Bioengineering 2023Quote: ... and QuickTiter™ Adenovirus Titer ELISA Kit (Cell Biolabs, San Diego, CA), respectively ...
-
bioRxiv - Immunology 2021Quote: ... The adenosine concentrations were determined using the Adenosine Assay Kit (Cell BioLabs, Inc.) following the manufacturer’s instructions.
-
bioRxiv - Neuroscience 2021Quote: ... We used HNE-His ELISA Kit (Cell BioLabs, Inc., San Diego, CA, USA) as described in Kandimalla et al 2016 ...
-
bioRxiv - Microbiology 2021Quote: ... Alanine concentrations were determined enzymatically using the Alanine Assay Kit (Cell Biolabs, Inc.) following the manufacturer’s instructions.
-
bioRxiv - Bioengineering 2022Quote: ... and 14 with a fluorometric glucose assay kit (Cell Biolabs Inc, California, USA). An MGO assay (methylglyoxal assay kit ...
-
bioRxiv - Cancer Biology 2022Quote: Cell adhesion assays were performed using ECM cell adhesion array kit (Cell Biolabs, Inc. ...
-
bioRxiv - Microbiology 2023Quote: Protein carbonyls were visualized using the OxiSelect Protein Carbonyl Immunoblot Kit (Cell Biolabs). Tnrf1-/- BMDMs were seeded in 24-well plates at 2.5x105 one day prior to infection with indicated L ...
-
bioRxiv - Microbiology 2023Quote: Protein carbonyls were quantified using the OxiSelect Protein Carbonyl ELISA Kit (Cell Biolabs) following manufacturer’s instructions ...
-
bioRxiv - Microbiology 2023Quote: Protein carbonylation was measured using the OxiSelect Protein Carbonyl ELISA Kit (Cell Biolabs) according to the manufacturer’s instructions ...