Labshake search
Citations for Lucigen :
1 - 50 of 709 citations for Rat Wide range C Peptide CP CLIA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genomics 2019Quote: The transposon used for genome wide insertion is derived from Ez-Tn5™ custom transposon kits (Epicentre). The insert is a cassette composed of the resistance gene to kanamycin and the gfpmut2 gene under control of the well characterized ribosomal promoter rrnBP1 ...
-
bioRxiv - Molecular Biology 2019Quote: ... rRNA was depleted using the Ribo-Zero kit Human/Mouse/Rat (Epicentre), and libraries were prepared using random priming ...
-
bioRxiv - Molecular Biology 2020Quote: ... with ribosomal depletion using Human/Mouse/Rat Ribo-Zero kit (Epicentre/Illumina). All samples were sequenced using a 100 base-pair (bp ...
-
bioRxiv - Genomics 2019Quote: ... Gram-negative and Human/mouse/rat Ribo-Zero rRNA Removal Kit (Epicentre Technologies). The resulting RNA was purified using Zymo RNA clean & Contentrator-5 column kit (ZYMO Research) ...
-
bioRxiv - Molecular Biology 2020Quote: Only cytoplasmic RNA was treated with the Ribo-Zero Magnetic Gold Kit for human/mouse/Rat (Epicentre) to remove ribosomal RNA ...
-
bioRxiv - Molecular Biology 2019Quote: ... 5µg of total RNA was subjected to rRNA depletion using the RiboZero Human/Mouse/Rat kit (Epicentre Biotechnologies). cDNA was generated from the depleted RNA using random hexamers or custom primers and Superscript III (Life Technologies ...
-
bioRxiv - Molecular Biology 2019Quote: ... Total RNA was depleted of ribosomal RNA using Ribo-Zero rRNA Removal Kit (Epicentre/Illumina, Human/Mouse/Rat) and library preparation was completed using NEBNext® Ultra Directional RNA Library Prep Kit for Illumina® (New England Biolabs) ...
-
bioRxiv - Molecular Biology 2024Quote: ... Purified RNA was subjected to ribosomal RNA depletion using the Ribo-Zero Magnetic Gold Kit (Human/Mouse/Rat; Epicentre), according to manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2021Quote: ... rRNA was depleted using Ribo-Zero™ Magnetic Gold Kit for rRNA depletion (Human/Mouse/Rat) (Epicentre for Illumina #MRZG12324) according to manufacturer’s guidelines ...
-
bioRxiv - Molecular Biology 2021Quote: ... Ribosomal RNA (rRNA) was depleted from RNA used for transcriptome analysis using Ribo-Zero rRNA Removal Kit (Human/Mouse/Rat) (Epicentre) according to the manufacturer’s protocol ...
-
bioRxiv - Molecular Biology 2022Quote: ... were sent to BGI (Hongkong) for ribosomal RNA depletion using Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) (Epicentre) followed by library construction using non-stranded (Replicate 1 ...
-
bioRxiv - Immunology 2019Quote: ... The DNase-treated RNA (2 μg) was treated with Ribo-Zero using an Epicentre Ribo-Zero Gold Kit (Human/Rat/Mouse) (Epicentre) and re-purified on Ampure XP beads.
-
bioRxiv - Molecular Biology 2023Quote: Total RNA from collected tissues and primary cultures was isolated using a standard TRIzol protocol followed by ribodepletion with a Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) according to the manufacturer’s instructions (Epicentre; RZG1224). Strand-specific libraries were prepared using a TruSeq RNA Sample Preparation Kit (Illumina ...
-
bioRxiv - Molecular Biology 2023Quote: Total RNA from collected tissues and primary cultures was isolated using a standard TRIzol protocol followed by ribodepletion with a Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) according to the manufacturer’s instructions (Epicentre; RZG1224). Strand-specific libraries were prepared using a TruSeq RNA Sample Preparation Kit (Illumina ...
-
bioRxiv - Systems Biology 2020Quote: ... Purified RNA (2.5 μg) was used for ribosome depletion using a Ribo-Zero™ Gold Kit (Human/Mouse/Rat) (Epicentre Biotechnologies) according to the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2022Quote: ... 5μg of RNA was subjected to ribosomal and mitochondrial RNA depletion using the RiboZero Gold kit (Human/Mouse/Rat, Epicentre #MRZG12324) according to manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2019Quote: One microgram of total RNA was rRNA depleted using the Ribo-Zero rRNA Removal Kit (Human, Mouse, Rat) (Epicentre, Madison, WI, USA) followed by a purification step using AMPure XP Beads (Beckman Coulter ...
-
bioRxiv - Cell Biology 2019Quote: ... were grown overnight at 37°C with 12.5 µg of chloramphenicol and extracted using a BACMAX DNA purification kit (Epicentre). Then ...
-
bioRxiv - Genomics 2020Quote: ... both transcripts were biotin-labeled after in vitro transcription from 1µg linearized pcDNA3.1-LETR1-1 and pcDNA3.1-LETR1-1-antisense plasmids for 1h at 37°C using Ampliscribe T7-flash biotin-RNA kit (Lucigen). Biotinylated LETR1 sense and antisense RNA were then treated with RNase-free DNase I for additional 15min at 37°C ...
-
bioRxiv - Immunology 2021Quote: ... heated to 98°C for 5 minutes and cooled to 24°C before use as template for in vitro transcription using the Ampliscribe T7-Flash Transcription Kit (Lucigen). Reactions were allowed to proceed overnight ...
-
bioRxiv - Molecular Biology 2020Quote: ... pombe DNA was extracted from cells grown to log phase at 32°C using MasterPureTM Yeast DNA purification kit (Lucigen/Epicentre). Genomic DNA of Ch16-Tel-DSB ...
-
bioRxiv - Molecular Biology 2020Quote: ... pombe DNA was extracted from cells grown to log phase at 32°C using MasterPureTM Yeast DNA purification kit (Lucigen/Epicentre). Genomic DNA of Ch16-Tel-DSB ...
-
bioRxiv - Synthetic Biology 2022Quote: ... Crude genomic DNA was generated by incubating yeast isolates at 95°C in 50 μL of 20 mM NaOH for 10 minutes or the MasterPure™ Yeast DNA Purification Kit (Lucigen). PCR Tag analysis was performed either by adding 1.8 μL of yeast lysate used as template DNA to 6.25 μL of 2X GoTaq® Green Master Mix (Promega) ...
-
bioRxiv - Synthetic Biology 2022Quote: ... The purified template was transcribed in vitro at 37 °C for 1 h using Ampliscribe™ T7-Flash™ Transcription kit (Lucigen, Epicentre) following the manufacturer’s instructions ...
-
bioRxiv - Synthetic Biology 2022Quote: The purified template was transcribed in vitro at 37 °C for 1 h and 30 min using Ampliscribe™ T7-Flash™ Transcription kit (Lucigen, Epicentre). After DNase treatment at 37 °C for 15 min ...
-
bioRxiv - Synthetic Biology 2022Quote: ... The purified template was transcribed in vitro at 37 °C for 1 h using Ampliscribe™ T7-Flash™ Transcription kit (Lucigen, Epicentre) following the manufacturer’s instructions ...
-
bioRxiv - Synthetic Biology 2022Quote: The purified template was transcribed in vitro at 37 °C for 1 h and 30 min using Ampliscribe™ T7-Flash™ Transcription kit (Lucigen, Epicentre). After DNase treatment at 37 °C for 15 min ...
-
bioRxiv - Microbiology 2022Quote: ... Swabs were incubated for one hour at 37°C with shaking in 300μL yeast cell lysis solution (from Lucigen MasterPure Yeast DNA Purification kit) and 10,000 units of ReadyLyse Lysozyme solution (Lucigen) ...
-
bioRxiv - Microbiology 2021Quote: ... sequences were designed to remove N-terminal signaling peptides and to add a histidine tag for immobilized metal affinity chromatography (IMAC) (in many cases using the Lucigen MA101-Expresso-T7-Cloning-&-Expression-System) ...
-
bioRxiv - Cancer Biology 2023Quote: ... 1 ml of 37 °C Recovery Medium (Lucigen, 80026-1) was added and bacteria were grown in round-bottom tubes for 1 h at 37 °C while shaking at 180 r.p.m ...
-
bioRxiv - Microbiology 2023Quote: ... and were cloned into the pETite C-His vector (Lucigen) with a C-terminal hexahistidine tag ...
-
bioRxiv - Systems Biology 2023Quote: ... and recovered for one hour at 37°C in Recovery Media (Lucigen). Aliquots from the transformations were used to inoculate overnight cultures of LB containing 25 μg/mL of Zeocin (ThermoFisher) ...
-
bioRxiv - Genomics 2023Quote: ... 1 μL of Hybridase Thermostable RNase H at 45°C (Lucigen (now Biosearch Technologies), Cat ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... 2min at 72 C) using the EconoTaq Plus protocol (Lucigen, Middleton, WI, United States). The PCR products were then digested ...
-
bioRxiv - Molecular Biology 2020Quote: ... Total RNA was then treated for 15min at 37°C with 10U RNase R from Epicentre in a 20 μl reaction volume ...
-
bioRxiv - Plant Biology 2024Quote: ... The CDS encoding FLVA (residues 55-723) was cloned into pETite® C-His Kan Vector (Lucigen) downstream of a sequence for a Strep-tag II (WSHPQFEK ...
-
bioRxiv - Genomics 2021Quote: ... Non circularized templates were eliminated by 2 h digestion at 37°C with Plasmid-safe DNAse (Epicentre, #E3101K), the enzyme was inactivated by heating for 30 minutes at 70°C ...
-
bioRxiv - Molecular Biology 2020Quote: ... DNA template was incubated at 37°C overnight in a transcription mix containing: transcription buffer 1X (Epicentre Biotechnologies), 1 mM 2’F-Py (2’F-2’-dCTP and 2’F-2’-dUTP ...
-
bioRxiv - Molecular Biology 2024Quote: ... C-circle and G-circles assays were performed as before except that NxGen phi29 DNA Polymerase (Lucigen Corp.) were used for rolling circle amplifications [25].
-
bioRxiv - Cell Biology 2022Quote: ... Plasmid Safe DNase kit (EpiCentre) was used to degrade any unspecific recombination products for 30 min at 37 °C ...
-
bioRxiv - Genomics 2019Quote: ... ARTseqTM kit from Epicentre (#RPHMR12126); RNaqueous kit from Ambion (#AM1912) ...
-
bioRxiv - Molecular Biology 2021Quote: ... C-circle and G-circles assays were performed as before except that NxGen® phi29 DNA Polymerase (Lucigen Corp.) were used for rolling circle amplifications [25].
-
bioRxiv - Microbiology 2021Quote: ... the cells were incubated for 10 min at 37°C in the presence of Ready-Lyse lysozyme solution (Epicentre) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2020Quote: ... HBV cccDNA was quantified from total DNA following digestion for 45 min at 37°C with T5 exonuclease (Epicentre) to remove rcDNA followed by 30 min heat inactivation ...
-
bioRxiv - Cancer Biology 2023Quote: ... at 37 °C for 5 min.The successful linearization of ecDNA was verified by verifying its sensitivity to exonucleaseATP-dependent DNase (Lucigen). After treatment with exonuclease ...
-
bioRxiv - Molecular Biology 2024Quote: Step 2 - extension & ligation: 10 μl of pre-heated (60°C) extension/ligation mix containing 5U of ampligase (Lucigen), 4U of Phusion HF DNA polymerase (#F530S ...
-
bioRxiv - Genetics 2021Quote: ... Masterpure Yeast RNA purification kit (Epicentre) was used to extract the RNA by following the manufacturer’s instructions ...
-
bioRxiv - Genomics 2020Quote: AmpliScribe SP6 Transcription Kit (Epicentre AS3106).
-
bioRxiv - Molecular Biology 2020Quote: Rolling Cycle Amplification (RCA) was done O/N at 30°C using 0.5 Units/μl Φ29 polymerase (Lucigen, 30221-2). The reaction mixture contained also 1X Φ29 buffer ...
-
bioRxiv - Biochemistry 2020Quote: ... ratio overnight at 16 °C followed by purification and then electroporation into phage-display competent TG-1 cells (#60502-1, Lucigen). The library was plated onto 2xYT agar plates containing 100 µg/mL carbenicillin and 2% glucose at 37 °C overnight ...