Labshake search
Citations for Lucigen :
101 - 150 of 784 citations for Rat Insulin Like Growth Factor 2 IGF2 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genomics 2020Quote: AmpliScribe SP6 Transcription Kit (Epicentre AS3106).
-
bioRxiv - Microbiology 2019Quote: ... Transposome mixtures were prepared by mixing the EZ-Tn5
2> transposon from Epicentre Biotechnologies ... -
bioRxiv - Evolutionary Biology 2021Quote: ... sample 2 was treated with 20 U RNase R (Epicentre/Illumina, Cat. No. RNR07250) for 1 h at 37°C to degrade linear RNAs ...
-
bioRxiv - Cell Biology 2023Quote: ... Electroporation was performed according to manufacturer’s instructions into Endura ElectroCompetent Cells (Lucigen, 60242-2). Dilution of transformed cells and estimation of the number of colony forming units allowed for calculation of plasmid library coverage of around 200x.
-
bioRxiv - Cell Biology 2023Quote: ... Electroporation was performed according to manufacturer’s instructions into Endura ElectroCompetent Cells (Lucigen, 60242-2). Dilution of transformed cells and estimation of the number of colony forming units allowed for calculation of plasmid library coverage ...
-
Cas13d-mediated isoform-specific RNA knockdown with a unified computational and experimental toolboxbioRxiv - Genomics 2023Quote: ... the assembled library plasmid pool was electroporated into Endura cells (Lucigen, Cat #60242-2) at 50-100 ng/µl ...
-
bioRxiv - Microbiology 2019Quote: ... rRNA depletion was performed (rRNA depletion Kit Ribo Zero Magnetic Kit for Gram-positive bacteria; Epicentre [Illumina]) according to the manufacturer’s instructions ...
-
bioRxiv - Systems Biology 2023Quote: ... Ribo-ZeroTM rRNA Removal Kits (Bacteria) and Ribo-ZeroTM Magnetic Gold Kit (Yeast) (Epicentre, San Diego, CA) were used to remove rRNA from the total RNA ...
-
bioRxiv - Microbiology 2021Quote: ... a combined kit for the ribosomal (rRNA) depletion Ribo-Zero™ Kit (Bacteria) (Epicentre, Illumina, Madison, WI USA) and cDNA library construction kit ...
-
bioRxiv - Microbiology 2021Quote: ... the assembled plasmid pool was used to transform 25μl of electrocompetent bacteria (Lucigen #60242-2) on a Bio-Rad Gene-Pulser 2 electroporation system (Bio-Rad # 1652105 ...
-
bioRxiv - Cancer Biology 2022Quote: ... The library was transformed into electrocompetent Lucigen Endura™ Escherichia coli (Lucigen; cat. 60242-2) using a Bio-Rad MicroPulser Electroporator (#1652100) ...
-
bioRxiv - Microbiology 2020Quote: ... end-repaired DNA from PoV-01B (1-2 Kb) were prepared by Lucigen (https://www.lucigen.com/) using the pSMART-HCKan cloning vector (Lucigen,WI ...
-
bioRxiv - Genetics 2021Quote: ... ribosomal depleted using Ribo-Zero Kit (Epicentre) and libraries prepared using ScriptSeq v2 RNA-Seq Library Preparation Kit (Epicentre) ...
-
bioRxiv - Systems Biology 2022Quote: ... the ribosomal RNA was depleted by Epicentre Ribo-zero® rRNA Removal Kit (Epicentre). Second ...
-
bioRxiv - Plant Biology 2021Quote: ... A Ribo-Zero magnetic kit (MRZPL116, Epicentre) was used for rRNA depletion from total RNA ...
-
bioRxiv - Immunology 2022Quote: ... ribosomal RNA was removed by Epicentre Ribo-zero™ rRNA Removal Kit (Epicentre) and rRNA-free residue was obtained by ethanol precipitation ...
-
bioRxiv - Microbiology 2022Quote: ATP-Dependent DNase kit (Lucigen, catalog #: E3110K).
-
bioRxiv - Bioengineering 2020Quote: ... using AmpliScribe T7-Flash Transcription Kit (Lucigen) following the manufacturer’s instruction and purified by RNA Clean & Concentrator (Zymo) ...
-
bioRxiv - Genomics 2021Quote: ... and the Globin-Zero Gold kit (Epicentre) to remove globin mRNA and ribosomal RNA ...
-
Multi-omics analysis reveals signatures of selection and loci associated with complex traits in pigsbioRxiv - Genomics 2023Quote: ... Ribosomal RNA was removed by Epicentre Ribo-zeroTM rRNA Removal Kit (Epicentre, USA), and rRNA- free residue was cleaned up by ethanol precipitation ...
-
bioRxiv - Molecular Biology 2024Quote: ... Poly(A) Polymerase Tailing Kit (Lucigen, UK), Direct RNA Sequencing Kit SQK-RNA002 ...
-
bioRxiv - Genomics 2020Quote: ... Pellets were resuspended in 2 µl water and subjected to electroporation into Endura competent cells (Lucigen) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2019Quote: ... One μl of the EZ-Tn5
2> Tnp transposome complex (Epicentre BioTechnologies, Madison, WI, USA) was added to electrocompetent S ... -
bioRxiv - Immunology 2021Quote: ... 40 nanograms of each library were transformed into Endura™ ElectroCompetent Cells (Lucigen cat 60242-2) following the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... 2) Poly(A)-tailing to add adenosines to the open 3’ ends of RNA (Lucigen, #PAP5104H), and 3 ...
-
bioRxiv - Cancer Biology 2023Quote: ... the pBA439_UMI20 library was electroporated into 25 μl of Lucigen Endura ElectroCompetent Cells (Lucigen, 60242-2) using prechilled 1 mm electroporation cuvettes (BioRad ...
-
bioRxiv - Molecular Biology 2023Quote: ... 20 mg of RNA (∼2 ml sample) was digested with 62.5 units of RNase I (Epicentre) at 4°C for 1 hr ...
-
bioRxiv - Molecular Biology 2019Quote: ... 40 μl of the whole cell lysate containing the digested chromatin was taken forward into an overnight blunt end ligation reaction (End-It DNA repair kit and Fast-Link DNA ligation kit, Epicentre) with double stranded DNA adapters at 16°C ...
-
bioRxiv - Genomics 2020Quote: ... The End-It DNA End-Repair Kit (Epicentre) was used to repair DNA fragments to blunt ends ...
-
bioRxiv - Molecular Biology 2021Quote: ... Ribosomal RNA was removed by Epicentre Ribo-zero™ rRNA Removal Kit (Epicentre, USA), and the libraries have been generated using NEBNext® Ultra™ Directional RNA Library Prep Kit for Illumina® (NEB ...
-
bioRxiv - Genomics 2020Quote: ... and NxSeq AmpFREE Low DNA Library Kit (Lucigen) was applied ...
-
bioRxiv - Genetics 2022Quote: ... and the MasterPureTM Yeast RNA Purification Kit (Epicentre). cDNAs were synthesized with the FastQuant RT Kit (with gDNase ...
-
bioRxiv - Cell Biology 2021Quote: ... The End-It DNA End-Repair Kit (Epicentre) was used to repair DNA fragments to blunt ends ...
-
bioRxiv - Microbiology 2020Quote: ... or MasterPure Gram Positive DNA purification kit (Lucigen). Sequencing libraries were prepared using NexteraXT (Illumina) ...
-
bioRxiv - Cell Biology 2019Quote: ... using the ScriptSeq kit (Epicentre, CA, USA SS10906). Libraries were amplified via polymerase chain reaction for 12–15 cycles and sequenced in two lanes on the HiSeq 2000 platform at BGI Genome Center (Shenzhen ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... repaired with End-IT DNA repair kit (Epicentre), A-tailed with Klenow enzyme (New England Biolabs) ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... (ii) Shotgun PCR-free library preparation kit (Lucigen) or (iii ...
-
bioRxiv - Plant Biology 2023Quote: ... with NxSeq AmpFREE Low DNA Library Kits (Lucigen). After size selection by AMPureXP beads ...
-
bioRxiv - Genomics 2022Quote: ... and three libraries for each sex were generated with the NEBNext Ultra RNA library prep kit combined with rRNA depletion via the Ribo-Zero Magnetic Gold kit (Epicentre Biotechnologies). Samples were sequenced on an Illumina HiSeq2500 platform at the Vienna BioCenter Core Facilities (VBCF ...
-
bioRxiv - Microbiology 2023Quote: ... Ribosomal RNA was depleted using the Ribo Zero kit and samples were converted into Illumina sequencing libraries using the ScriptSeq v2 RNA-Seq Library Preparation Kit (Epicentre, Illumina). Libraries were sequenced using Illumina HiSeq (2 × 150 bp reads) ...
-
bioRxiv - Genomics 2023Quote: ... Each aliquot of 4 μg was depleted from ribosomal RNA with 10 μl of rRNA removal solution from the Ribo-Zero kit (RiboZero kit, catalog num. MRZH11124, Epicentre-Illlumina), strictly following the manufacturer’s protocol ...
-
bioRxiv - Microbiology 2021Quote: ... 100µl of competent cells was mixed with 1 µl of EZ-Tn5 KAN-2 Tnp Transposome (Epicentre) and electroporated at 1800V ...
-
bioRxiv - Molecular Biology 2021Quote: ... 2 μg of rRNA-depleted RNA were treated with 1 U Terminator 5’-Phosphate-Dependent Exonuclease (Epicentre) in the 1x Buffer A in the presence of 40 U RNaseOUT in a 50 μL reaction at 30 °C for 1 h ...
-
bioRxiv - Microbiology 2019Quote: ... were used to amplify lnt that had been disrupted by the insertion of Tn5
2> (Epicentre) [6] ... -
bioRxiv - Neuroscience 2021Quote: ... We used 1.5 μL of the ligation mix and electroporated 30 μL competent bacteria (Lucigen, 60242-2) with ...
-
bioRxiv - Genetics 2020Quote: ... 2 µl per tube was transformed into two tubes of 50 µl of electrocompetent cells (Lucigen DUO) following the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2022Quote: ... the lysates containing 10 µg of total RNA were treated with 2 U/µg RNase I (Lucigen) at 25°C for 45 min ...
-
bioRxiv - Genomics 2019Quote: ... DNA was extracted using “Yeast Masterpure kit” (Epicentre, USA) following the manufacturer’s instructions.
-
bioRxiv - Genetics 2020Quote: Total DNA was extracted using a QuickExtract kit (Lucigen). Unless otherwise indicated ...
-
bioRxiv - Genetics 2020Quote: ... and a MasterPure™ Yeast DNA Purification Kit (Lucigen). PE150 libraries of the evolved strains were prepared and sequenced by Novogen.