Labshake search
Citations for Agilent :
251 - 300 of 845 citations for U Bottom Microplate 96 well since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Developmental Biology 2023Quote: ... Day 1 and day 8 worms were collected in M9 buffer and washed three times before being pipetted into a Seahorse 96 well plate (Agilent Technologies Seahorse Flux Pack 103793-100) ...
-
bioRxiv - Microbiology 2023Quote: ... 200 μl were aliquoted into black 96 well plates in triplicate and fluorescence was measured using a BioTek Cytation 5 Cell Imaging Multimode Reader (Agilent). The excitation wavelength used was 488 nm and emission wavelength used was 530 nm.
-
bioRxiv - Microbiology 2023Quote: ... This system makes it possible to culture many bacterial strains in parallel in a replicated manner using many 96-well plates which are handled with a stacker (BioStack 4, Agilent Technologies ...
-
bioRxiv - Microbiology 2023Quote: Log phase cultures of cells grown without inducer were diluted to an OD600 of 0.05 and grown in 96-well plates for 24 h at 30°C with constant shaking on a BioTek Cytation 1 plate reader (Agilent), measuring the absorbance at 600 nm every 30 min for three technical replicates for each strain ...
-
bioRxiv - Genetics 2024Quote: ... Day 1 and day 8 worms were collected in M9 buffer and washer three times before being pipetted into a Seahorse 96 well plate (Agilent Technologies Seahorse Flux Pack 103793-100) ...
-
bioRxiv - Cancer Biology 2024Quote: ... Measure the absorbance at 450 nm using a microplate reader (BioTek Epoch Microplate reader, Agilent tech) and the mean cell viability was calculated relative to control ...
-
bioRxiv - Immunology 2020Quote: ... coated XF96 cell culture microplate (Agilent) with a density of 100’000 or 150’000 cells/well and rested in Seahorse XF RMPI 1640 medium supplemented with 2 mM L-glutamine ...
-
bioRxiv - Cell Biology 2023Quote: ... cell culture microplate (Agilent Seahorse Bioscience) was coated with Cell-Tak cell and tissue adhesive (Corning ...
-
bioRxiv - Immunology 2024Quote: ... coated XF96 microplate (Agilent, 101085-004). Plates were spun down ...
-
bioRxiv - Cancer Biology 2023Quote: ... Seahorse XF24 cell culture microplates (Agilent) were coated with 0.5 mg mL-1 poly-L-lysine (Sigma Aldrich Chemie GmbH ...
-
bioRxiv - Cell Biology 2023Quote: ... cell culture microplate (Agilent Seahorse Bioscience) was coated with Cell-Tak cell and tissue adhesive (Corning ...
-
bioRxiv - Biophysics 2021Quote: ... The thermal variations were in the range 25-95°C in a stepwise increment of 1 °C/minute step and using a 96-well PCR plate (Agilent Technologies) sealed with optical quality sealing tape (Microseal® ‘B’ seal from BIO-RAD) ...
-
bioRxiv - Immunology 2019Quote: ... Immuno-affinity purification through Protein-A Sepharose beads covalently bound to W6-32 antibodies was performed in a format of 96-well single-use micro plate with 10 µm polypropylene membranes (SeaHorse Bioscience). The plates were then washed 4 times with 2mL 150 mM NaCl and 20 mM Tris HCl (buffer A) ...
-
bioRxiv - Cell Biology 2022Quote: ... only 10 μL of MTS reagent was added to plate wells because there was not enough reagent to add 20 μL to all 96 wells.) End-point absorbance measurements were taken with a plate reader at 490 nm (BioTek Instruments, Agilent Technologies).
-
bioRxiv - Cell Biology 2020Quote: ... parental HCT116 cells and HCT116 cells with SMYD5 overexpression (OE) or knockout (KO) were seeded in 96-well plate (in triplicates) (#101085-004, Seahorse Bioscience) one day before measurement ...
-
bioRxiv - Microbiology 2024Quote: ... Cultures were grown at 30 °C in 96-well plates in an BioTek Epoch 2 shaking incubator (Agilent, Santa Clara, CA) for 72 hours.
-
bioRxiv - Immunology 2024Quote: Key metabolic parameters of human and bovine MØ were determined in real time by measuring oxygen consumption rate (OCR) and Extracellular Acidification Rate (ECAR) using a Seahorse XFe 96-well extracellular flux analyzer (Agilent, USA). Briefly ...
-
bioRxiv - Bioengineering 2024Quote: ... 8 U/mL (Prozyme) – 400 U/mL (NEB) ...
-
bioRxiv - Microbiology 2024Quote: ... Colorimetric conversion was terminated by addition of 5% SDS (50 uL per well) and absorbance was measured at 414 nm using a BioTek Epoch 2 Microplate Spectrophotometer (Agilent Technologies, Santa Clara, CA, USA). The endpoint absorbance of each sample was determined on a plate-by-plate basis where the absorbances of all the blank wells were averaged and multiplied by three ...
-
bioRxiv - Cell Biology 2019Quote: Cell mitochondrial oxygen consumption rates (OCRs) were assayed in 96-well plates by using a XF Cell Mito Stress Test Kit (Cat. #: 101706100, Seahorse Bioscience, U.S.) on the XFe96 Extracellular Flux Analyzer (Seahorse Bioscience ...
-
bioRxiv - Systems Biology 2021Quote: ... Sample fractions were continuously collected into 96 well plates by an Agilent 1100 Series Micro-FC G1364D micro fraction collector (Agilent Technologies, Germany). For each sample ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... A 470 µL aliquot of pre-mixed solution without TQ was transferred to a 96-well plate (Agilent Technologies, Santa Clara, USA) three wells (n = 3) ...
-
bioRxiv - Cell Biology 2020Quote: ... treated Seahorse XF96 Cell Culture Microplates (Agilent) and XFe96 sensor cartridge (Agilent ...
-
bioRxiv - Cell Biology 2022Quote: ... with a thermal microplate sealer (PlateLoc, Agilent) and then stored at -20 °C until use ...
-
bioRxiv - Cell Biology 2020Quote: ... or Seahorse XF24 microplates (Agilent 100777-004) coated with 3 μg/mL rat tail collagen I (Corning 354236 ...
-
bioRxiv - Synthetic Biology 2022Quote: ... using the Plateloc Thermal Microplate Sealer (Agilent). qPCRs were run using the Applied Biosystems QuantStudio 5 ...
-
bioRxiv - Microbiology 2023Quote: ... coated XF96 cell culture microplate (Agilent, USA). Sterile media was added as blanks for background measurement ...
-
bioRxiv - Biochemistry 2023Quote: ... using a PlateLoc thermal microplate sealer (Agilent) and kept at - 20°C until used ...
-
bioRxiv - Microbiology 2021Quote: ... Supernatant was harvested by centrifugation at 1500 rcf for 4 minutes at 23°C and filtered using a Captiva 96 well 0.2 μm filter plate (Agilent Technologies, Santa Clara, CA) prior to titer measurement by RP-UHPLC.
-
bioRxiv - Cancer Biology 2022Quote: ... cells were seeded at pre-optimized final concentration 1.5 x 104 cells/well onto Seahorse XF-96-well plates and glycolysis stress and mito Stress tests were performed following the manufacturer’s specifications (Seahorse Bioscience, North Billerica, MA). Each datum was determined minimally in triplicate ...
-
bioRxiv - Plant Biology 2019Quote: ... and gene-specific primers (Supplementary Table 1) to a final volume of 20 μl in clear 96-well plates with clear plastic lids (Agilent Technologies, Waldbronn, Germany). QRT-PCR assays were performed using an AriaMx Real-Time PCR system (G8830A instrument ...
-
bioRxiv - Microbiology 2023Quote: ... ODs were obtained by measuring absorbance at 600nM in a 96-well plate using Cytation Station 5 (BioTek Agilent Technologies, Santa Clara, CA). The liquid cultures were centrifuged at 3500 rpm for 5 minutes (Sorvall Legend X1R M20 rotor ...
-
bioRxiv - Microbiology 2023Quote: ... ODs were obtained by measuring absorbance at 600nM in a 96-well plate using Cytation Station 5 (BioTek Agilent Technologies, Santa Clara, CA). 108 colony-forming units (CFUs ...
-
bioRxiv - Bioengineering 2020Quote: ... inserts were transferred to a new clear bottom plate where fluorescence was immediately measured using a bottom reading fluorescence plate reader (BioTek, Agilent) at 485/535 nm (Ex/Em) ...
-
bioRxiv - Microbiology 2023Quote: ... Growth curves of OD578 were monitored every hour after 1 min of linear shaking under anaerobic conditions using an Epoch2 microplate reader coupled with a Biostack 4 microplate stacker (both Agilent) housed in a custom-made incubator (EMBL workshop24) ...
-
bioRxiv - Microbiology 2022Quote: ... we triple parafilmed the 96 well plate lid and put it immediately into an optical reader (Biotek synergy HTX, Agilent, Santa Clara CA, USA) which incubated the plate at 30°C ...
-
bioRxiv - Plant Biology 2023Quote: ... Peptides were desalted using C18 solid phase extraction columns (Bond Elut SPEC C18, 96 round-well plate, 15 mg, 1 mL, Agilent Technologies, Santa Clara, USA) and a water-jet (vacuum ...
-
bioRxiv - Plant Biology 2023Quote: The aliquot of 100 µL taken from the lipophilic phase of the MTBE extraction was diluted 10-fold with methanol and the extracts were measured under an Epoch2 96-well plate reader (Biotek/Agilent; Santa Clara, CA, U.S.A.). Spectrum was measured at 470 nm ...
-
bioRxiv - Immunology 2021Quote: ... The spheroid microplates (Agilent, Santa Clara, CA, USA) were coated with Cell-Tak (22.4 mg/mL ...
-
bioRxiv - Cancer Biology 2022Quote: After coating Seahorse XFe24 Cell Culture Microplates (Agilent) with Poly-D-lysine hydrobromide (FUJIFILM Wako Pure Chemical) ...
-
bioRxiv - Cell Biology 2022Quote: ... plate 15K in Seahorse microplates (Agilent, 101084-004) with FRTL5 media ...
-
bioRxiv - Biochemistry 2022Quote: ... a Power Wave XS microplate reader (BioTek Agilent) was used to monitor OD600 ...
-
bioRxiv - Neuroscience 2023Quote: ... and read on BioTek ELx800 Microplate Reader (Agilent). Serum samples were analyzed using LEGENDplex MU Inflammatory Panel (13-plex ...
-
bioRxiv - Cancer Biology 2023Quote: ... Seahorse XF96 Cell Culture Microplates (101085; Agilent Technologies) were treated with Cell-Tak Cell and Tissue Adhesive (354240 ...
-
bioRxiv - Cancer Biology 2023Quote: ... to digest any residual chromosomal DNA and then quantified using a microplate spectrophotometer (BioTek Epoch Microplate Spectrophotometer, Agilent Technologies Inc, USA).
-
bioRxiv - Cell Biology 2022Quote: ... and XF-96 FluxPaks (Agilent). The mito-stress test (MTS ...
-
bioRxiv - Microbiology 2022Quote: RNAseq libraries preparation of the 5uL aliquots of adult tick and nymph tick total RNA preps was also performed in 96 well format on an automated liquid handler (Bravo automated liquid handler, Agilent Technologies, Santa Clara, CA, USA). Briefly ...
-
bioRxiv - Physiology 2021Quote: ... PHTs were plated onto a Seahorse XFe96 microplate (Agilent) at 0.5 x 106 cells/well following isolation ...
-
bioRxiv - Immunology 2022Quote: ... pre-coated XF96 Cell Culture Microplates (Seahorse, Agilent Technologies). Cells were centrifuged at 200 ×g for 2 min in a zero-braking setting to immobilize cells before being supplied with an additional 130 μL assay medium and kept in a non-CO2 incubator for 30 min ...
-
bioRxiv - Neuroscience 2020Quote: ... iPSC-derived neurons were plated on XFp microplates (Agilent) at a density of 70,000 per well and grown in N2 medium for 48 hrs before the experiment ...