Labshake search
Citations for Agilent :
1 - 50 of 1175 citations for 6 Methyl 2 phenyl 1H indole since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... Amino acids were separated using a VF-5ms inert 5% phenyl-methyl column (Agilent Technologies). The oven temperature was constant at 120 °C for 5 min ...
-
bioRxiv - Bioengineering 2021Quote: ... The GC-MS system used was the 7890-5975C from Agilent in combination with the HP-5MS column (5% phenyl methyl polysiloxane, 30m×0.25mm ID, 0.25µm) from Agilent. The temperature was maintained at 180 °C for 1 min ...
-
bioRxiv - Molecular Biology 2024Quote: ... HP-5 MS column (5% phenyl methyl polysiloxane: 30m x 0.25mm i.d. x 0.25 µm, Agilent technologies) was used for metabolite separation ...
-
bioRxiv - Plant Biology 2019Quote: ... An HP-5MS capillary column (5%phenyl-methyl-siloxane, 30-m, 250-mm, and 0.25-mm film thickness; Agilent) was used with helium carrier gas at 2 mL/min ...
-
bioRxiv - Plant Biology 2021Quote: Quantitative analysis was performed using a HP-5MS capillary column (5% phenyl-methyl-siloxane, 30 m x 250 mm, 0.25 mm film thickness; Agilent) with helium carrier gas at 1.5 mL/min ...
-
bioRxiv - Cell Biology 2022Quote: ... Derivatized samples were analyzed using an Agilent Technologies 7890B gas chromatographer with a HP-5MS 5% phenyl methyl Silox column (Agilent) coupled to an Agilent Technologies 5977A mass spectrometer ...
-
bioRxiv - Synthetic Biology 2021Quote: 2-methyl tryptophan was quantified by an LC-MS system (Agilent) using an XBridge BEH Amide 2.5 μm (Waters ...
-
bioRxiv - Microbiology 2023Quote: ... Poroshell 120 Phenyl Hexyl column (Agilent Technologies, USA) was used for separation ...
-
bioRxiv - Developmental Biology 2023Quote: Mouse methyl capture sequencing (Methyl-Seq) libraries were generated using the SureSelectXT Methyl-Seq Target Enrichment System (Agilent, Santa Clara, CA, USA, #G9651B) and the SureSelectXT Mouse Methyl-Seq target enrichment panel (Agilent ...
-
bioRxiv - Plant Biology 2019Quote: ... and indole was added into a 2.0ml amber glass vial (Agilent Technologies) with 1 mg of glass wool (Fig ...
-
bioRxiv - Bioengineering 2024Quote: ... Poroshell 120 Phenyl Hexyl column (Agilent Technologies, Santa Clara, CA) held at 40°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... Silica beads functionalized with phenyl-boronic acid (Bondesil-PBA 40µm, Agilent) were used for glycopeptides enrichment at an optimized ratio of 1:2.5 sample:PBA beads w/w ...
-
bioRxiv - Microbiology 2022Quote: ... Online mass axis correction was performed with purine and hexakis(1H,1H,3H-tetrafluoropropoxy)phosphazine (HP-0921, Agilent Technologies). The source gas temperature of the ESI ion source was 225 °C ...
-
bioRxiv - Plant Biology 2022Quote: ... camalexin and indole-3-acetonitrile (IAN) were performed using Agilent 1200 HPLC System (Agilent, USA) equipped with diode array and fluorescence (FLD ...
-
bioRxiv - Immunology 2019Quote: ... as internal standard were analyzed by 1D 1H and 1H{13C}-HSQC NMR on a 14.1 T DD2 NMR spectrometer (Agilent Technologies, CA). 1D 1H spectra were acquired using the standard PRESAT pulse sequence with 512 transients ...
-
bioRxiv - Microbiology 2021Quote: ... Online mass calibration was performed using a second spray needle and a constant flow of reference solution containing purine and hexakis (1H, 1H, 3H -tetrafluoropropoxy)phosphazine (HP-0921, Agilent Technologies). After processing of raw data as previously described24 ...
-
bioRxiv - Microbiology 2021Quote: ... Online mass calibration was performed using a second spray needle and a constant flow (5 ul/min) of reference solution containing purine and hexakis (1H, 1H, 3H -tetrafluoropropoxy)phosphazine (HP-0921, Agilent Technologies). Compounds were identified based on the retention time of chemical standards and their accurate mass (tolerance 20 ppm) ...
-
bioRxiv - Microbiology 2021Quote: ... Online mass calibration was performed using a second spray needle and a constant flow (5 ul/min) of reference solution containing purine and hexakis (1H, 1H, 3H -tetrafluoropropoxy)phosphazine (HP-0921, Agilent Technologies). Compounds were identified based on the retention time of chemical standards and their accurate mass (tolerance 20 ppm) ...
-
bioRxiv - Physiology 2020Quote: ... Cell nuclei were counter-stained in methyl green (Dako). Specimens were then dehydrated in series of ethanol and xylene ...
-
bioRxiv - Molecular Biology 2023Quote: ... incubated 1h with HRP-conjugated secondary antibodies (DAKO, 1:2000) in 1X TBS-Tween containing 5% non-fat dry milk ...
-
bioRxiv - Developmental Biology 2023Quote: ... was used to produce Methyl-Seq libraries using a SureSelectXT Methyl-Seq Target Enrichment System with a mouse enrichment panel (Agilent #G9651B and #5191-6704) following the manufacturer’s recommendations ...
-
bioRxiv - Cell Biology 2022Quote: ... and SureSelectXT Mouse Methyl-Seq Reagent Kit (Agilent Catalog # 931052) ...
-
bioRxiv - Neuroscience 2022Quote: ... sections were blocked for 1h with serum-free block (Dako, X0909), and incubated over-night with our custom-made DDX5 antibodies (1:500 ...
-
bioRxiv - Biochemistry 2020Quote: ... Complete imidazolinone conversion was checked by 1H-NMR (MR400 MHz, Agilent) For the reversal tests ...
-
bioRxiv - Developmental Biology 2020Quote: ... and rabbit anti-Lysozyme antibody (A0099, DAKO 1:1000 (Fig. 1h), GTX72913 ...
-
bioRxiv - Genomics 2020Quote: ... As described in manufacturer’s protocol (Agilent SureSelectXT Mouse Methyl-Seq Kit), bisulfite converted libraries were PCR-amplified for 8 cycles with supplied universal primers and purified using AMPure XP beads ...
-
bioRxiv - Cell Biology 2021Quote: ... and 299.294 m/z (Methyl Stearate; Agilent article number G1982-85003) were used to recalibrate spectra during the acquisition.
-
bioRxiv - Microbiology 2021Quote: ... and analysed as fatty acid methyl esters by gas chromatography (Agilent 6890N ...
-
bioRxiv - Plant Biology 2020Quote: ... equipped with a 5% phenyl-polymethylsiloxane capillary column (DB-5MS, 30 m × 0.25 mm × 1.0 μm; Agilent).
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... We used an Agilent ZORBAX SB-Phenyl column (2.1×100mm, 1.8-Micron, Agilent, Santa Clara CA, USA) maintained at 20°C with in-line Filter (0.3 μm SS Frit ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... ON) mass spectrometer using a Eclipse Plus phenyl hexyl column (4.6 A 100mm, 5 µm column, Agilent) and 1290 Infinity II inline filter (0.3 µm) ...
-
bioRxiv - Plant Biology 2019Quote: ... β-caryophyllene and 20 mg indole (Erb et al., 2015) was added into separate 2.0 ml amber glass vial (Agilent Technologies) with 1 mg of glass wool (Fig ...
-
bioRxiv - Cell Biology 2021Quote: ... One microliter of the derivatized samples was injected into an Agilent 6890 GC interfaced to an Agilent 5973 quadrupole MS with a HP-5ms (5%-Phenyl)-methylpolysiloxane column (30 m × 0.25 mm × 0.25 μm, Agilent) in splitless mode ...
-
bioRxiv - Microbiology 2023Quote: ... methyl citrate and methylmalonyl-CoA were separated by reverse phase with a poroshell 120 Phenyl-Hexyl analytical column (2.1 x 50mm, 2.7 µm, Agilent) and a binary gradient (Table S2 ...
-
bioRxiv - Synthetic Biology 2023Quote: ... NMR spectroscopic data (1H, 13C, HSQC, COSY, and HMBC) were collected by Agilent 600 MHz (14.1 Tesla ...
-
bioRxiv - Bioengineering 2024Quote: ... The resulting polymers were characterized by 1H NMR in CDCl3 and SEC (Agilent Infinity 1200 HPLC ...
-
bioRxiv - Cell Biology 2019Quote: ... Fatty acid methyl esters were detected by GC-MS (Agilent 5977A-7890B) according to the method described in Ramakrishnan et al ...
-
bioRxiv - Developmental Biology 2023Quote: ... and the SureSelectXT Mouse Methyl-Seq target enrichment panel (Agilent, #5191-6704) following the manufacturer’s recommendations ...
-
bioRxiv - Microbiology 2020Quote: ... Separation occurred with a HP-5 ms capillary column coated with 5% phenyl-95% methylpolysiloxane (30 m×250 µm i.d., 0.25 µm film thickness, Agilent Technologies).
-
bioRxiv - Plant Biology 2024Quote: ... The organic phase was dried using anhydrous MgSO4 and analysed on GC-2010 Pro gas chromatograph (Shimadzu, Japan) equipped with an HP-5MS 30 m × 0.25 mm (5%-Phenyl)-methylpolysiloxane column (19091S-133, Agilent) with nitrogen as the carrier gas with splitless injection mode ...
-
bioRxiv - Microbiology 2019Quote: ... and 6’-Sialyllactosamine (6’SLN) (Prozyme, Hayward CA) were used to annotate HPLC peaks ...
-
bioRxiv - Bioengineering 2022Quote: ... Cell nuclei were then counterstained with 4′,6-diamidino-2-phenylindole (DAPI) for 5 min before being mounted using DAKO mounting medium (Agilent, catalog no. S302380–2). Imaging of the histological samples was performed on the Microscope Axio Imager.A2 (Carl Zeiss Microscopy ...
-
bioRxiv - Developmental Biology 2020Quote: ... The following primary antibodies and dilutions were used: guinea pig anti-Insulin (1:6, Dako, IR00261-2), mouse anti-Glucagon (1:500 ...
-
bioRxiv - Biochemistry 2020Quote: ... 50 Pulsed-splitless injection was used to inject 5 μL samples onto an HP-5ms (5%-phenyl)-methylpolysiloxane capillary GC column (Agilent Technologies ...
-
bioRxiv - Systems Biology 2023Quote: ... we used an Eclipse Plus Phenyl-Hexyl column (250 mm length, 4.6 mm diameter, 5 µm particle size, Agilent Technologies) and a Diode Array Detector (G4212 ...
-
bioRxiv - Microbiology 2024Quote: ... and 280 nm with a Eclipse Plus Phenyl-Hexyl column (250 mm length, 4.6 mm diameter, 5 μm particle size, Agilent Technologies). The flow rate was set to 0.5 mL/min for a 70/30 combination of the mobile phase in water and acetonitrile (Sigma-Aldrich ...
-
bioRxiv - Biochemistry 2023Quote: ... The resulting 1-O-methyl-glycoside TMS derivatives were analysed by GC-MS (Agilent Technologies ...
-
bioRxiv - Physiology 2020Quote: ... DAPI (4′,6-diamidino-2-phenylindole; 1:1000) was used as nuclei staining and fluorescent mounting medium (DAKO) to cover the slides before imaging acquisition ...
-
bioRxiv - Cancer Biology 2023Quote: ... The slides were steamed for 35 minutes with a pH 6 Dako Target Retrieval (Agilent Technologies, S169984-2) and permeabilized with 0.1% Triton X-100 (Sigma-Aldrich ...
-
bioRxiv - Microbiology 2020Quote: ... n-dodecane samples were subjected to the Agilent 6890N gas chromatograph equipped with a (5%-phenyl)-methylpolysiloxane HP-5 column (length, 30 m; inside diameter, 0.32 mm; film thickness, 0.25 mm; Agilent Technologies, Ratingen, Germany) and a flame ionization detector (FID) ...