Labshake search
Citations for Agilent :
201 - 250 of 6342 citations for QuantiFluo Acid Phosphatase Assay Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... with dsDNA HS (High Sensitivity) Assay Kit and Bioanalyzer Agilent 2100 using a High Sensitivity DNA chip (Agilent Genomics). Indexed libraries were then equimolarly pooled and quantified by qPCR using the KAPA library quantification kit (Roche) ...
-
bioRxiv - Biophysics 2020Quote: ... Calibration curves of individual and mixed amino acids were prepared using either 250 pmol stocks of corresponding individual amino acids or a 250 pmol amino acid standard mix (Agilent #5061-3331). Quantification was performed using calibration curves of the respective amino acid standards.
-
bioRxiv - Biophysics 2021Quote: ... (buffer A: 0.1% trifluoro-acetic acid in water, buffer B 100% acetonitrile with 0.1% trifluoro-acetic acid; Agilent Zorbax 300SB-C18 column). Collected protein fractions were lyophilized and stored at −20 °C.
-
bioRxiv - Neuroscience 2021Quote: ... Alkaline phosphatase activity was detected by incubating slides with Fast Red substrate (DAKO, K0597) for 30 minutes.
-
bioRxiv - Systems Biology 2021Quote: ... Endogenous peroxidase and alkaline phosphatase activity were quenched with Dual Endogenous Enzyme Block (Dako). Sections were then rinsed in wash buffer and incubated with primary antibody against Ki67 (MIB1 (Dako M7240 ...
-
bioRxiv - Genomics 2023Quote: ... endogenous peroxidase was blocked using the Peroxidase and Alkaline Phosphatase Blocking Reagent (Agilent Dako) and the Dual-Link Envision system (Agilent Dako ...
-
bioRxiv - Genomics 2023Quote: ... endogenous peroxidase was blocked using the Peroxidase and Alkaline Phosphatase Blocking Reagent (Agilent Dako) and the Dual-Link Envision system (Agilent Dako ...
-
bioRxiv - Biochemistry 2023Quote: ... and a λ-phosphatase gene was transformed into chemically competent BL21-CodonPlus (DE3) (Agilent) cells following manufacture instructions and plated with ampicillin ...
-
bioRxiv - Neuroscience 2020Quote: ... anti-glial acid fibrillary protein (GFAP) (Dako, 1: 1000). A classical astrocyte marker (Gomes-Leal et al. ...
-
bioRxiv - Immunology 2022Quote: ... and 5 μM medronic acid (5191-4506, Agilent Technologies). For positive mode analysis ...
-
bioRxiv - Genetics 2020Quote: ... The concentration of amino acids was determined by Agilent 1260 HPLC system ...
-
bioRxiv - Immunology 2022Quote: ... and 5 µM medronic acid (5191-4506, Agilent Technologies). For positive mode analysis ...
-
bioRxiv - Biochemistry 2023Quote: ... and 0.01% medronic acid (v/v, 5191-4506, Agilent). For the re-equilibration gradient ...
-
bioRxiv - Physiology 2024Quote: ... Etomoxir (an inhibitor of long chain fatty acid oxidation) provided in the Seahorse XF Mito fuel flex test kit (Agilent Technologies, Cat#103260-100). Fuel dependency for a specific pathway was measured after inhibiting this pathway ...
-
bioRxiv - Biochemistry 2019Quote: ... The p-coumaric acid and caffeic acid peaks were identified by comparing the retention times to authentic standards and by mass spectrometry (Agilent G6120, quadrupole MS). The integrated peak areas were converted to concentrations in mM based on calibration curves generated with authentic standards.
-
bioRxiv - Microbiology 2019Quote: ... The concentrations of the solvents (acetone, acetic acid, butyric acid, butanol, and ethanol) were determined using gas chromatography (7890A, Agilent, Wilmington, DE, USA). Isobutyl alcohol and isobutyric acid were used as the internal standards for solvent quantification.
-
bioRxiv - Biochemistry 2021Quote: ... The HPLC profile of tannic acid and gallic acid at both pH’s was obtained using an Infinity II HPLC system (Agilent Technologies, Santa Clara, CA) and an Agilent 5 prep-C18 column (50×21.2 mm ...
-
bioRxiv - Bioengineering 2023Quote: ... The optical purity of L-lactic acid and D-lactic acid were measured via a HPLC system (Agilent 1260 series, Hewlett-Packard, USA) equipped with a SCAS Sumichiral OA-5000 column (150 × 4.6 mm ...
-
bioRxiv - Developmental Biology 2021Quote: RNA integrity was assessed on an Experion bioanalyzer using a Bio-Rad Experion RNA High-Sensitivity kit or an Agilent 2100 bioanalyzer using a Bioanalyzer RNA 6000 Pico assay (Agilent). RNA concentrations were measured using a Qubit 4 fluorometer with a Qubit high-sensitivity RNA assay.
-
bioRxiv - Developmental Biology 2020Quote: ... RNA integrity was assessed through the RNA 6000 Pico Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). A total amount of 3μg RNA per sample was used for mRNA purification and library construction via the Truseq™ RNA Sample Prep Kit (Illumina ...
-
bioRxiv - Molecular Biology 2022Quote: Concentrations were measured by Qubit RNA HS assay kit and the quality of RNA was analyzed on Tapestation D5000 HS (Agilent). Removal of rRNAs from isolated samples of IFNβ stimulated ESCs and MEFs was done following the protocol of Ribo-Zero rRNA removal kit ...
-
bioRxiv - Neuroscience 2021Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). A total amount of 3 µg RNA per sample was used as input material for the RNA sample preparations ...
-
bioRxiv - Molecular Biology 2021Quote: ... RNA integrity and concentration were checked using the RNA Pico 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies). Small RNA libraries were prepared from 1 ng of RNA using the NEXTflex Small RNA-seq Kit v3 (Perkin Elmer) ...
-
bioRxiv - Genomics 2020Quote: ... RNA quality was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA) and was checked on RNase free agarose gel electrophoresis ...
-
bioRxiv - Biochemistry 2019Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). The RNA concentration was measured with an RNA Assay Kit in Qubit 2.0 Flurometer (Life Technologies ...
-
bioRxiv - Genomics 2020Quote: ... Final library concentration was assessed by Qubit dsDNA HS Assay Kit (Thermo-Fischer Scientific) and fragment size was checked using Tapestation High Sensitivity D1000 (Agilent) to ensure that fragment sizes were distributed normally about 500 bp ...
-
bioRxiv - Genomics 2020Quote: ... The quality of the library was checked on DNA high sensitivity assay kit on Bio-analyser 2100 (Agilent Technologies, USA) and were sequenced on the Ion S5 Plus sequencing platform using 530 chip.
-
bioRxiv - Systems Biology 2020Quote: ... After double XP beads purifications (with beads added in a ratio 1:1) libraries were quantified on a Fragment Analyzer run with a NGS Assay Kit (Agilent) and loaded on a HiSeq 3000 flowcell with 50 cycles single end sequencing by pooling the samples based on molarity aiming for 30 mio ...
-
bioRxiv - Molecular Biology 2019Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit for the Bioanalyzer 2100 system (Agilent Technologies, CA, USA) and RNA concentration was measured using Qubit® RNA Assay Kit in Qubit® 2.0 Flurometer (Life Technologies ...
-
bioRxiv - Genomics 2020Quote: ... with a Qubit RNA BR (Broad-Range) or Qubit RNA HS assay kit and with RNA Screen Tape and Sample buffer using TapeStation 4150 (Agilent). RNA with an RNA integrity number (RIN ...
-
bioRxiv - Bioengineering 2021Quote: ... RNA integrity was assessed using an RNA Nano 6000 Assay Kit from the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). The RNA-seq library was then generated using the NEBNext® Ultra™ RNA Library Prep Kit for Illumina® (NEB ...
-
bioRxiv - Plant Biology 2020Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). The sequencing libraries preparation and high-throughput sequencing were carried out by Novogene Bioinformatics Technology CO. ...
-
bioRxiv - Plant Biology 2020Quote: ... concentration and integrity was evaluated on 0.8% agarose gels and by the RNA Nano 6000 Assay Kit using Bioanalyzer instrument (Agilent Technologies). For RNA-seq analysis ...
-
bioRxiv - Microbiology 2021Quote: ... Illumina sequencing libraries were analyzed by microchip electrophoresis on an Agilent 2100 Bioanalyzer using DNA 7500 Assay Kit (Agilent Technologies).
-
bioRxiv - Microbiology 2021Quote: ... Illumina sequencing libraries were analyzed by microchip electrophoresis on an Agilent 2100 Bioanalyzer using DNA 7500 Assay Kit (Agilent Technologies). The samples containing fragments shorter than 300 bp were split (<300 bp and >300bp ...
-
bioRxiv - Molecular Biology 2020Quote: ... the molarity of our libraries was determined using the concentration of our library from Qubit 3.0 Fluorometer (using the Qubit dsDNA high-sensitivity assay kit) and the average library size (bp) using an Agilent Tapestation 2200 (using the Agilent high-sensitivity D1000 ScreenTape and reagents) ...
-
bioRxiv - Cancer Biology 2020Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). The mRNA enrichment ...
-
bioRxiv - Cell Biology 2021Quote: ... RNA integrity was assessed using the Agilent RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent, CA, USA). A total amount of 3 µg RNA per sample was used as input material for the RNA sample preparations ...
-
bioRxiv - Cancer Biology 2022Quote: ... Glycolytic and mitochondrial ATP production rates were determined according to the XF Real-Time ATP Rate Assay Kit protocol (Agilent). Briefly ...
-
bioRxiv - Cell Biology 2022Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). RNA quality control was performed using a fragment analyser and standard or high-sensitivity RNA analysis kits (Labgene ...
-
bioRxiv - Molecular Biology 2022Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). Sequencing libraries were generated using NEBNext® UltraTM RNA Library Prep Kit for Illumina® (NEB ...
-
bioRxiv - Genomics 2022Quote: ... as measured on a 4150 Tapestation System using a High Sensitivity RNA ScreenTape Assay kit (5067-5579/5580, Agilent Technologies), were greater than 8 ...
-
bioRxiv - Neuroscience 2021Quote: ... Libraries were prepared using the NEBNext Ultra Directional RNA Library Prep Kit for Illumina and verified using the Bioanalyzer RNA Nano Assay (Agilent) before sequencing on the NextSeq 500 (Illumina) ...
-
bioRxiv - Microbiology 2020Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA).
-
bioRxiv - Genetics 2021Quote: ... RNA quality control (QC) was performed with the RNA 6000 Nano kit analysed using the 2100 Bioanalyzer Eukaryote Total RNA Nano assay (Agilent). cDNA libraries for sequencing were produced using the KAPA mRNA HyperPrep Kit for Illumina Platforms (Kapa Biosystems ...
-
bioRxiv - Zoology 2020Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). Three micrograms of RNA per sample was used as input material for the RNA sample preparations ...
-
bioRxiv - Plant Biology 2020Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). A total amount of 3 μg RNA per sample was used as input material for the RNA sample preparations ...
-
bioRxiv - Microbiology 2021Quote: All viral stocks were generated in Vero cells and tested negative for Mycoplasma contamination using a MycoSensor PCR Assay Kit (Agilent). Detailed passage histories of the ZIKV isolates used in this study were previously described (56) ...
-
bioRxiv - Plant Biology 2021Quote: ... RNA integrity was then assessed using Agilent 2100 Bioanalyzer with the RNA 6000 Nano Assay Kit (Agilent Technologies, CA, USA). Library preparation was carried out using Illumina TruSeq RNA sample preparation kit (Illumina ...
-
bioRxiv - Microbiology 2021Quote: ... and RNA integrity was assessed using the RNA Nano 6000 Assay Kit for the Agilent Bioanalyzer 2100 system (Agilent Technologies). Sequencing libraries were generated using the NEBNext Ultra Directional RNA Library Prep Kit for Illumina (NEB ...