Labshake search
Citations for Agilent :
1251 - 1300 of 8755 citations for Human Fragile X Mental Retardation 1 Neighbor Protein FMR1NB ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2019Quote: ... Epithelial cells in the EDTA fraction were depleted by incubation with anti-human epithelial antigen antibody (clone Ber-EP4, Dako) followed by anti-mouse IgG dynabeads (ThermoFisher ...
-
bioRxiv - Genomics 2021Quote: ... the initial concentrations of purified SARS-CoV-2 and the universal human reference RNA (UHRR, Agilent Technologies, product number 740000) were determined by ddPCR as described above ...
-
bioRxiv - Microbiology 2022Quote: ... Slides were then washed in PBS/0.05% Tween 20 and incubated with rabbit anti human VWF (A008229-2, DAKO/Agilent tech) 1/500 or rabbit IgG isotype control (AB-105-C ...
-
bioRxiv - Genomics 2023Quote: ... Hybrid capture of exonic regions was performed using Agilent SureSelect in-solution capture reagents and SureSelect XT Human All Exon V4 probes (Agilent). Captured libraries were sequenced using 100 bp paired-end runs on Illumina HiSeq 2500 ...
-
bioRxiv - Cell Biology 2023Quote: ... was purchased from Jackson ImmunoResearch Laboratories and was used for Western blotting. Affinity-purified rabbit polyclonal anti-human lambda-light chain (cat. A019302-2) was purchased from Dako and was used for Western blotting ...
-
bioRxiv - Cell Biology 2023Quote: ... RNA samples were labeled and hybridized to a SurePrint G3 Human GEO microarray 8 × 60K Ver 3.0 (Agilent, CA, USA), and the raw data were normalized using the 75-percentile shift ...
-
bioRxiv - Cancer Biology 2023Quote: ... was performed using the Exome Cancer Test v2.0 (EXaCT-2) assay that was developed with Agilent based on SureSelect Human All Exon V6 (Agilent Technologies) (manuscript in preparation) ...
-
bioRxiv - Pathology 2023Quote: ... consecutive 4-μm slices of human aspirated thrombi were immunohistochemically stained using antibodies against CD34 (mouse monoclonal, clone QBEnd10; Dako/Agilent), FXI (LSBio) ...
-
bioRxiv - Immunology 2024Quote: To accurately investigate the bioenergetic function of bovine and human MØ with an extracellular flux analyser (Seahorse Bioscience, Inc, USA), both cell types were characterized according to the manufacturer’s recommended basal and test conditions (23).
-
bioRxiv - Immunology 2024Quote: ... Bound ACPA IgG was detected by incubation with horseradish peroxidase-labelled rabbit anti-human IgG (P0214; Agilent Dako, CA, USA) diluted 1:8000 in PBT for 1 h at 37 °C before the ELISA was read out using ABTS and H2O2 at an iMark Microplate Absorbance Reader (Bio-Rad Laboratories ...
-
bioRxiv - Immunology 2024Quote: ... Bound ACPA IgG was detected by incubation with horseradish peroxidase-labelled rabbit anti-human IgG (P0214; Agilent Dako, CA, USA) diluted 1:8000 in PBT for 1 h at 37 °C before the ELISA was read out using ABTS and H2O2 at an iMark Microplate Absorbance Reader (Bio-Rad Laboratories ...
-
bioRxiv - Cancer Biology 2024Quote: ... DNA genomic libraries were prepared from fresh tissue (tumor and nontumor) and FFPE tumor tissue DNA prior to exome capture (SureSelect XT Human All Exon v5, Agilent). Libraries were sequenced on a HiSeq2000 instrument (Illumina ...
-
bioRxiv - Molecular Biology 2020Quote: ... Genemorph II Random Mutagenesis kits and QuikChange mutagenesis kits were purchased from Agilent Technologies ...
-
bioRxiv - Neuroscience 2023Quote: ... and evaluated using the RNA high sensitivity kit (Agilent RNA 6000 Pico Kit) and an Agilent 2100 Bioanalyzer ...
-
bioRxiv - Neuroscience 2022Quote: ... 1 × 1 M (Agilent Technologies). Genomic DNA from wild-type mouse ES cells (CMTI-2 ...
-
bioRxiv - Developmental Biology 2021Quote: ... Sections were then incubated with primary antibodies for 48 h at 4°C (AXIN2 1:100, FZD1 1:100, LEF1 1:100, AQP1 1:100, OTX2 1:50, β-Catenin cell signaling 1:400, β-Catenin Dako 1:200), washed and subsequently incubated with secondary anti-mouse or anti-rabbit antibodies diluted in PBS (at 1:1000 ...
-
bioRxiv - Plant Biology 2020Quote: ... The filtrate was injected into Spherisorb 5μm ODS column (250 mm x 4.6 mm) for HPLC (model 1260) coupled to 1200 series evaporative light scattering detector (Agilent Technologies, Santa Clara, CA, USA). This analysis was conducted twice independently with 2 to 3 technical replications each ...
-
bioRxiv - Biochemistry 2021Quote: ... Preparative purification by HPLC was carried out on an Agilent 1260 Infinity II device using an Eclipse XDB-C18 (Agilent, 21.2 x 250mm, 7µm) reversed-phase column ...
-
bioRxiv - Cell Biology 2021Quote: ... a trap column of 20 mm x 100 μm ID Reprosil C18 (Dr. Maisch, Ammerbuch, Germany) and a 450 mm x 75 μm ID Poroshell C18 analytical column (Zorbax, Agilent Technologies, Santa Clara, CA), all packed in-house ...
-
bioRxiv - Cell Biology 2022Quote: ... Digested peptides were separated using a 50 cm reversed-phase column packed in-house (Agilent Poroshell EC-C18, 2.7 µm, 50cm x 75 µm) and were eluted at a flow rate of 300 nl/min using a linear gradient with buffer A (0.1% FA ...
-
bioRxiv - Cell Biology 2022Quote: ... Digested peptides were separated using a 50 cm reversed-phase column packed in-house (Agilent Poroshell EC-C18, 2.7 µm, 50cm x 75 µm). The peptides were eluted from the column at a flow rate of 300 nl/min using a linear gradient with buffer A (0.1% formic acid (FA) ...
-
bioRxiv - Biochemistry 2023Quote: ... Preparative purification by high-performance liquid chromatography (HPLC) was carried out on an Agilent 1260 Infinity II device using an Eclipse XDB-C18 (Agilent, 21.2 x 250mm, 7µm) reversed-phase column ...
-
bioRxiv - Biochemistry 2023Quote: ... Preparative purification by HPLC was carried out on an Agilent 1260 Infinity II device using an Eclipse XDB-C18 (Agilent, 21.2 x 250mm, 7µm) reversed-phase column ...
-
bioRxiv - Biochemistry 2023Quote: ... Preparative purification by HPLC was carried out on an Agilent 1260 Infinity II device using an Eclipse XDB-C18 (Agilent, 21.2 x 250mm, 7µm) reversed phase column ...
-
bioRxiv - Cell Biology 2023Quote: ... Then cells were fixed in fixed in 4 % of paraformaldehyde in phosphate-buffered saline (PBS) before permeabilization with 0.5% Triton X-100 in PBS and stained with primary antibodies: anti-Ki67 (M7240, Agilent Dako, Santa Clara, CA, USA) diluted at 1/50 and anti-Poly-ubiquitin purchased from ENZO (ENZ-ABS840 ...
-
bioRxiv - Cell Biology 2024Quote: ... Digested peptides were separated using a 50 cm reversed-phase column packed in-house (Agilent Poroshell EC-C18, 2.7 µm, 50cm x 75 µm) and eluted from the column at a flow rate of 300 nL/min ...
-
bioRxiv - Developmental Biology 2022Quote: ... Mutations were generated within the miR-1 seed sequences using the QuikChange Lightning or QuikChange Multi Site-Directed Mutagenesis Kit (Agilent Technologies, Santa Clara, California) to disrupt miR-1’s binding and regulatory function (Gregory et al. ...
-
bioRxiv - Immunology 2022Quote: ... Phe322 was substituted for the Tyr322 residue of WT and G307S DNAM-1 by using QuikChange II Site-Directed Mutagenesis Kits (Agilent technologies, Palo Alto, CA) with primers (5′-GAGAGGATATTTTTGTCAACTATCCAACC-3′ and 5′-GGTTGGATAGTTGACAAAAATATCCTCTC-3′) ...
-
bioRxiv - Genomics 2021Quote: ... A mouse monoclonal anti-p63 antibody (1:500, MS-1081-P, Neomarkers, Fremont, CA, USA) and followed by a secondary kit (Mouse Envision, DAKO-Agilent, Santa Clara CA, USA), stained with chromogen (3,3′-Diaminobenzidine [DAB] ...
-
bioRxiv - Microbiology 2023Quote: ... tissues were incubated with proteinase K diluted 1:10 in 1X TBS (Fisher Scientific, Cat. #BP24711; and PNA ISH kit, Agilent Dako, Cat. #K5201) for 10 min at RT in a humidity chamber ...
-
bioRxiv - Cell Biology 2019Quote: ... Sections were blocked in Dako protein block solution (X090, Agilent Technologies, Santa Clara, CA) for 1hr and incubated OVN at 4°C with indicated primary antibodies ...
-
bioRxiv - Cell Biology 2020Quote: ... Proteins were injected into a reverse phase HPLC (Agilent 1100 series HPLC, Agilent Technologies) with a Zorbax 300SB-C18 (2.1 x 50mm ...
-
bioRxiv - Cell Biology 2020Quote: ... Proteins were injected into a reverse phase HPLC (Agilent 1100 series HPLC, Agilent Technologies) with a Zorbax 300SB-C18 (2.1 x 50mm ...
-
bioRxiv - Immunology 2019Quote: ... Non-specific protein binding was blocked by incubation with 10% normal goat serum (DAKO). Primary antibodies were applied overnight at 4 ...
-
bioRxiv - Cell Biology 2019Quote: ... The fusion protein was expressed in BL21 Codon Plus (DE3) RIPL Escherichia coli (Agilent) using 0.5 mM IPTG in 2xYT broth 5 hrs at 37°C and purified under native condition over Ni-NTA Agarose (Invitrogen) ...
-
bioRxiv - Neuroscience 2020Quote: ... rabbit anti-Glial Fibrillary Acidic Protein (GFAP) (Polyclonal, Dako Agilent, Santa Clara, CA, USA); mouse anti-Calbindin1 (clone CB-955 ...
-
bioRxiv - Neuroscience 2020Quote: ... rabbit anti-Glial Fibrillary Acidic Protein (GFAP) (Polyclonal, Dako Agilent, Santa Clara, CA, USA); mouse anti-Calbindin1 (clone CB-955 ...
-
bioRxiv - Neuroscience 2021Quote: ... rabbit anti-Glial Fibrillary Acidic Protein (GFAP) (Polyclonal, Dako Agilent, Santa Clara, CA, USA); mouse anti-NeuN (clone A60 ...
-
bioRxiv - Neuroscience 2021Quote: ... rabbit anti-Glial Fibrillary Acidic Protein (GFAP) (Polyclonal, Dako Agilent, Santa Clara, CA, USA); mouse anti-NeuN (clone A60 ...
-
bioRxiv - Microbiology 2020Quote: Intrinsic tryptophan fluorescence of recombinant protein was measured using a Cary Eclipse Spectrophotometer (Agilent) and Jasco FP-8500 Spectrofluorometer ...
-
bioRxiv - Cell Biology 2022Quote: ... All three proteins were expressed in BL21-Gold (DE3) competent cells (Agilent Technologies; 230132). The cells were cultured in 4 L of Luria Bertani broth (LB ...
-
bioRxiv - Biochemistry 2019Quote: ... The recombinant proteins were overexpressed in E coli BL21 (DE3) Codon plus RIL (Stratagene) at 15 °C and purified by affinity chromatography on Ni-nitrilotriacetate resin (Qiagen ...
-
bioRxiv - Biochemistry 2019Quote: ... Mutant proteins were also overexpressed in E coli BL21 (DE3) Codon plus RIL (Stratagene) and purified using the same procedures described above ...
-
bioRxiv - Microbiology 2019Quote: ... and width of protein fibrils were measured manually using PicoView1.10 software (Agilent Technologies, USA).
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Samples were washed and blocked for 10 min (Dako protein block, Agilent, CA, USA) before being treated with primary antibodies overnight ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Samples were washed and blocked for 10 min (Dako protein block, Agilent, CA, USA) before being treated with primary antibodies overnight ...
-
bioRxiv - Synthetic Biology 2020Quote: ... Affinity purification of biotinylated proteins was carried out in a Bravo AssayMap platform (Agilent) using AssayMap streptavidin cartridges (Agilent) ...
-
bioRxiv - Developmental Biology 2019Quote: ... then blocked in serum-free protein blocking solution (Agilent Dako, Santa Clara, CA, USA) for 1hr at room temperature ...
-
bioRxiv - Developmental Biology 2019Quote: ... then blocked in serum-free protein blocking solution (Agilent Dako, Santa Clara, CA, USA) for 1hr at room temperature ...
-
bioRxiv - Biochemistry 2021Quote: ... All Mtr4 proteins were recombinantly expressed in Escherichia coli BL21-CodonPlus (DE3)-RIPL (Stratagene) using an autoinduction protocol (Studier ...