Labshake search
Citations for Agilent :
4951 - 5000 of 6919 citations for Nitrite Microplate Assay Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2024Quote: Quality and quantification of the Hi-C libraries was assessed using the 2100 Bioanalyzer (Agilent, DNA 7500 kit). An equimolar pool of the different samples was sequenced on the Illumina NextSeq 550 System in a 75bp paired-end setup ...
-
bioRxiv - Neuroscience 2024Quote: ... and quality control was performed with the RNA 6000 Nano Kit on a 2100 Bioanalyzer Instrument (both Agilent). Libraries were sent to Novogene for 150 bp paired-end sequencing on the Illumina Novaseq 6000 platform (400 million reads per sample ...
-
bioRxiv - Neuroscience 2024Quote: ... 50 to 5.000 pg/μl range was measured using chips from the RNA 6.000 Pico Kit (Agilent Technologies).
-
bioRxiv - Cancer Biology 2024Quote: ... quantified with NanoDrop) was checked for quality with a tape station using the RNA ScreenTape Analysis kit (Agilent) according to manufacturer’s protocol ...
-
bioRxiv - Cancer Biology 2024Quote: ... Size and quality of libraries were verified using the Agilent high sensitivity DNA kit (Agilent Technologies; 5067-4626) and Agilent Bioanalyzer System (Agilent Technologies) ...
-
bioRxiv - Molecular Biology 2024Quote: ... Quality control for the sequencing libraries involved the use of an Agilent high sensitivity DNA kit (Agilent Technologies) and Fragment Analyzer Systems (Agilent Technologies ...
-
bioRxiv - Physiology 2024Quote: ... we performed the bioenergetic analysis using the Seahorse T-cell Mitochondrial profiling kit (part. no.: 103771-100, Agilent) with a final concentration of 4mM Oligomycin ...
-
bioRxiv - Plant Biology 2024Quote: The RXLR or EER mutant vectors were generated using the QuikChange II XL site-directed mutagenesis kit (Agilent). Gene-specific mutagenic primers were designed using the QuikChange primer design program (https://www.agilent.com/store/primerDesignProgram.jsp ...
-
bioRxiv - Physiology 2024Quote: Nutrient dependencies and capacities were measured using the Seahorse XF Mito Fuel Flex Test Kit (103260-100, Agilent). In detail ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... We measured sample concentration and purity using the Agilent 2100 Bioanalyzer (Agilent RNA Eukaryote Total RNA Nano Kit), and the Invitrogen Qubit RNA Broad Range Assay Kit ...
-
bioRxiv - Genetics 2024Quote: ... Sample quality was assessed using an Agilent RNA 6000 Nano Kit on an Agilent BioAnalyzer 2100 (Agilent Technologies), and a Qubit RNA BR Assay Kit on a Qubit 2.0 Fluorometer (Invitrogen) ...
-
STAT5B SH2 variants disrupt mammary enhancers and the stability of genetic programs during pregnancybioRxiv - Genetics 2024Quote: ... Target capture for the exome was performed on each sample using SureSelect Mouse All Exon kit (Agilent Technologies). DNA was subjected to SureSelect Target Enrichment System for paired-end DNA library preparation ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... The integrity and quantity of RNA was checked using an Agilent 2100 Bioanalyser (Agilent RNA 6000 Nano Kit), and submitted to BGI Hong Kong for HiSeq small RNA library construction and 50-bp single end sequencing ...
-
bioRxiv - Cell Biology 2024Quote: ... CENTB-FAM (PNAbio; F3006) and Telomere TelG-Cy3 (PNA FISH kit, Dako Agilent; K532611-8 or PNAbio; F1006). A coverslip (18x18mm ...
-
bioRxiv - Cell Biology 2024Quote: ... CENTB-FAM (PNAbio; F3006) and Telomere TelG-Cy3 (PNA FISH kit, Dako Agilent; K532611-8 or PNAbio; F1006). A coverslip (18x18mm ...
-
bioRxiv - Physiology 2024Quote: ... The quality of the RNA samples was analyzed using an Agilent RNA 6000 nano kit (Bioanalyzer, Agilent Technologies). Samples with RIN scores above 9.5 were used in library preparation ...
-
bioRxiv - Neuroscience 2024Quote: ... for samples extracted form sorted somata and using a 2100 Bioanalyzer with the RNA 6000 Pico kit (Agilent) for samples extracted from sorted GCs ...
-
bioRxiv - Molecular Biology 2024Quote: ... Two µL of each diluted sample were run using the gDNA 165kb Analysis Kit #FP-1002-0275 (Agilent) according to the manufacturer’s instructions ...
-
bioRxiv - Plant Biology 2020Quote: ... The quality and quantity of RNA were assayed using an Agilent RNA 6000 Nano Kit Bioanalyzer chip (Agilent Technologies). Sample labeling was done following the Low Input Quick Amp Labelling protocol of the Two-Color Microarray-Based Gene Expression Analysis system (Agilent Technologies) ...
-
bioRxiv - Plant Biology 2020Quote: ... The V2 null TYLCV mutant was generated with the QuickChange Lightning Site-Directed Mutagenesis Kit (Agilent Technologies, Cat #210518) using the WT infectious clone as template ...
-
bioRxiv - Biophysics 2021Quote: ... Concentrations were determined with a Qubit dsDNA HS kit and amplification was confirmed on a 2200 TapeStation (Agilent Genomics). 30 ng of each library were pooled and submitted for MiSeq sequencing.
-
bioRxiv - Genetics 2019Quote: ... 3 μg of purified RNA were converted into cDNA via the Affinity Script QPCR cDNA synthesis kit (Agilent Technologies). cDNA synthesized without the RT/RNase block enzyme mixture was utilized as a control for genomic DNA contamination ...
-
bioRxiv - Molecular Biology 2019Quote: ... The final product was assessed for its size distribution and concentration using BioAnalyzer High Sensitivity DNA Kit (Agilent Technologies) and qPCR (Kapa Biosystems) ...
-
bioRxiv - Cell Biology 2019Quote: ... 2007) as a template to introduce the A63V change by the QuickChange II Site-Directed Mutagenesis Kit (Agilent Technologies). The ASNA-1A63V::GFP containing plasmid (pGK200 ...
-
bioRxiv - Cell Biology 2020Quote: ... 2 μM fluoro-carbonyl cyanide phenylhydrazone (FCCP) and 0.5 μM rotenone + 0.5 μM antimycin from the Seahorse XF Cell Mito Stress Test Kit (Agilent Technologies). Data was analyzed by the Seahorse XF Cell Mito Stress Test Report Generator ...
-
bioRxiv - Cell Biology 2020Quote: Mito stress test: Agilent Seahorse XF Mito Stress Test Kit was used as per the standard protocol by Agilent Seahorse (https://www.agilent.com/cs/library/usermanuals/public/XF_Cell_Mito_Stress_Test_Kit_User_Guide.pdf) ...
-
bioRxiv - Cell Biology 2020Quote: ... The EXD2-M126A variant was created by site-directed mutagenesis of pDEST-EXD2_iso1-BirA*-FLAG construct using Quick Change Lightning kit (Stratagene).
-
bioRxiv - Cell Biology 2020Quote: ... pNG72-GFP-L-CHMP4C S210A was generated by site-directed mutagenesis using a commercial kit (Quickchange Lightning, Agilent Technologies). For retroviral production ...
-
bioRxiv - Cell Biology 2020Quote: ... The PCR products of positive clones were then cloned into competent cells using the StrataClone PCR Cloning Kit (Agilent) according to the manufacturer’s protocol ...
-
bioRxiv - Cell Biology 2020Quote: We constructed the MELT motif mutants of Spc105 using the QuickChange II XL Site-Directed mutagenesis kit (Agilent Technologies). To build pAJ737 (Spc105_#4-6 in #1-3) ...
-
bioRxiv - Cell Biology 2020Quote: ... Myc-CUL5-ΔNEDD8 (K724A/K727A/K728A) mutant was obtained using QuickChange Multi Site-Directed Mutagenesis kit from Agilent (#200514) using the primer shown in Table S5 ...
-
bioRxiv - Genetics 2021Quote: ... the 1 kb fragment including human FTO SNP rs1421085_T (the reference allele) and rs1421085_C (the minor allele) were constructed using the QuikChange II site-directed mutagenesis kit (Stratagene) and inserted in forward or reverse orientation ahead of hFTOp into the pGL4.12 vector ...
-
bioRxiv - Genetics 2021Quote: ... we introduced the corresponding single nucleotide mutation in the 3xFLAG donor plasmid using QuikChange Site-Directed Mutagenesis Kit (Agilent). Then this donor plasmid was used for the same process used to generate the BAG3WT-FLAG line25 ...
-
bioRxiv - Developmental Biology 2021Quote: ... Quality of the libraries was evaluated on a Agilent 2100 Bioanalyzer using the High Sensitivity DNA Kit (Agilent Technologies). Samples were sequenced using HiSeq2500 machine.
-
bioRxiv - Cancer Biology 2021Quote: ... Library quality was assessed with a BioAnalyzer 2100 using the High Sensitivity DNA kit (Agilent Technologies, Santa Clara, CA). The libraries were quantified using the Kapa Library Quantification Kit Illumina Platforms (Kapa Biosystems ...
-
bioRxiv - Immunology 2021Quote: ... Glycans were isolated and labeled with a fluorescent molecule using a GlykoPrep InstantAB labeling kit (Prozyme, Hayward, CA, USA) following the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2021Quote: ... The NS gene segments of A_NS237 and B_NS217 were modified using QuikChange II Site Directed Mutagenesis Kit according to the instruction manual (Agilent, Germany). The sequence of mutagenesis primers is available upon request.
-
bioRxiv - Evolutionary Biology 2020Quote: ... Site-directed mutagenesis of the Spk-1 gene in pNR139.5 and pNR141.1 was performed essentially as described by the QuikChange II Site-Directed Mutagenesis Kit (Agilent Technologies). For pNR139.5 ...
-
bioRxiv - Developmental Biology 2021Quote: ... RNA quantity and quality were measured using an Agilent 2100 Bioanalyzer with the 6000 Pico Kit (Agilent, 5067-1513). Full-length cDNA was prepared using Clontech’s SMART-Seq v4 Ultra Low Input RNA Kit (634888 ...
-
bioRxiv - Developmental Biology 2021Quote: ... RNA quality and quantity were then assessed using Agilent RNA 6000 Pico kit on Agilent 2100 Bioanalyzer (Agilent Technologies).
-
bioRxiv - Evolutionary Biology 2021Quote: ... We produced the promoter inserts by performing error-prone PCR using the GeneMorph II Random Mutagenesis Kit (Agilent Technologies). We used the plasmid constructs with MG1655 promoter variants cloned into them as template DNA for the error-prone PCR aiming to achieve approximately 1.5 SNPs per promoter sequence ...
-
bioRxiv - Biophysics 2020Quote: ... Site-directed mutagenesis of all the mutants was performed using the QuikChange™ XL site-directed mutagenesis kit (Stratagene) with the corresponding Orai1 constructs serving as a template.
-
bioRxiv - Molecular Biology 2020Quote: The quality of sequencing libraries was controlled on a Bioanalyzer 2100 using the Agilent High Sensitivity DNA Kit (Agilent). Pooled sequencing libraries were quantified with digital polymerase chain reaction (PCR ...
-
bioRxiv - Molecular Biology 2021Quote: ... The size distribution of the libraries was assessed on a Bioanalyzer with a DNA High Sensitivity kit (Agilent Technologies), and concentration was measured with the Qubit DNA High Sensitivity kit in the Qubit 2.0 Fluorometer (Life Technologies) ...
-
bioRxiv - Molecular Biology 2020Quote: ... The average size and concentration of all libraries was analysed using the 2100 Bioanalyzer High Sensitivity DNA Kit (Agilent) followed by qPCR using SensiMix SYBR (Bioline ...
-
Nulliparity affects the expression of a limited number of genes and pathways in Day 8 equine embryosbioRxiv - Developmental Biology 2022Quote: ... RNA quality and quantity were assessed with the 2100 Bioanalyzer system using RNA 6000 Pico kit (Agilent Technologies, France) according to the manufacturer’s instructions.
-
bioRxiv - Evolutionary Biology 2022Quote: ... The purified RNA was quality-controlled using an Agilent 2100 Bioanalyzer and an RNA 6000 Nano kit (Agilent Technologies). A microarray experiment was performed using an Agilent 8× 60 K array ...
-
bioRxiv - Genomics 2020Quote: ... cfDNA quality was assessed using an Agilent 2100 Bioanalyzer and DNA HS Kit (Agilent Technologies, Palo Alto, CA, USA).
-
bioRxiv - Molecular Biology 2021Quote: ... The average size and concentration of all libraries was analyzed using the 2100 Bioanalyzer High Sensitivity DNA Kit (Agilent) followed by qPCR quantification using SensiMix SYBR (Bioline ...
-
bioRxiv - Biophysics 2019Quote: ... All site-directed mutagenesis were performed using the Agilent Quikchange Lightning site-directed mutagenesis kit (Agilent Technologies, CA, USA). The expression was induced by adding 1 mM IPTG to a culture that had reached an OD of 0.5-0.6 ...