Labshake search
Citations for Agilent :
4951 - 5000 of 5536 citations for Cow Ameloblastin AMBN ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genetics 2024Quote: ... was used for all experiments with integrated Cas9 (Supplementary Table 3).25 Cas9D10A was generated by site-directed mutagenesis of pLS504 using the QuikChange II XL Site-Directed Mutagenesis Kit (Agilent #200521) using primers MK11 and MK12 ...
-
bioRxiv - Cell Biology 2024Quote: The aforementioned mutations in the hypervariable regions of RhoA-GFP and RhoB-GFP were generated according to the manufacturing instructions of the QuickChange Lightning Site-Directed Mutagenesis kit (Agilent Technologies) using the mutagenic primers listed in the Key Resources Table ...
-
bioRxiv - Cell Biology 2024Quote: ... The S71A and S71E mutations were introduced into the pDONR221-gCDC42attb plasmid with the QuickChange II XL Site Directed Mutagenesis Kit (#200521, Agilent Technologies) with the following primers ...
-
bioRxiv - Cell Biology 2024Quote: ... The integrity and quantity of the total RNA was measured using an Agilent 2100 Bioanalyzer RNA 6000 Nano Kit (Agilent Technologies). Total RNA obtained from each sample was subjected to sequencing library construction using NEBNext Ultra Directional RNA Library Prep Kit for Illumina (New England Biolabs ...
-
bioRxiv - Cell Biology 2024Quote: ... The S71A mutation was introduced into the pMALc-MBP::CDC-42 plasmid with the QuickChange II XL Site directed mutagenesis kit (#200521, Agilent technologies) with the following primers ...
-
bioRxiv - Cell Biology 2024Quote: ... The INF2-ER[K792A] GFP construct was generated via site-directed mutagenesis using the QuikChange II Site-Directed Mutagenesis Kit (Agilent Technologies). All constructs were sequenced completely across their coding region.
-
bioRxiv - Evolutionary Biology 2024Quote: ... Purified RNA samples were analyzed for quality control using an Agilent 2100 Bioanalyzer and an RNA 6000 Nano kit (Agilent Technologies). Microarray experiments were performed using a custom-designed Agilent 8 × 60 K array for the E ...
-
bioRxiv - Developmental Biology 2024Quote: ... The quality and concentration of the libraries were assessed using the Agilent High Sensitivity DNA Kit and Bioanalyzer 2100 (Agilent Technologies) and submitted to 150 bp paired-end high throughput sequencing using Hiseq4000 (Illumina).
-
bioRxiv - Cell Biology 2024Quote: Cy3-labeled cRNAs were further hybridized onto Agilent Whole Human Genome kit 4 x 44K slides (Catalog number G4112F, Agilent Technologies) containing 44,397 oligonucleotide probes in 2X Hi-RPM Hybridization buffer (Catalog number 5188-5242 ...
-
bioRxiv - Microbiology 2024Quote: ... in which the glutamic acid in the active site was substituted by alanine employing QuikChange Lightning Site-Directed Mutagenesis Kit (Agilent Technologies) and appropriate primers listed in SI appendix ...
-
bioRxiv - Zoology 2024Quote: ... RNA integrity was verified using an Agilent 2100 Bioanalyzer and an RNA 6000 Nano Kit (Agilent Technologies, Santa Clara, CA, USA). RIN values ≥ 7.0 were considered appropriate for mRNA library preparation ...
-
bioRxiv - Immunology 2024Quote: The integrity of the isolated RNA (according to the aforementioned protocol) was measured with a Fragment Analyzer using RNA Kit 15 nt (Agilent Technologies). Samples with an RNA integrity number ≥ 8 were used for sequencing ...
-
bioRxiv - Immunology 2024Quote: ... Detection was achieved using Leica DAB Detection Kit (Bond Polymer Refine Detection) for CD4 and Envision FLEX DAB+ (Diaminobenzidine) (Dako Omnis) for BCL6 ...
-
bioRxiv - Microbiology 2024Quote: ... Site-directed mutagenesis of the Trp252 residue in BoGH5A was performed using the QuikChange II Site Directed Mutagenesis (SDM) Kit (Agilent Technologies) according to the manufacturer’s protocol.
-
bioRxiv - Neuroscience 2024Quote: The mutant PDI-Ala256 protein was prepared from the full-length wild-type human PDI cDNA using the QuikChange II XL Site-Directed Mutagenesis Kit (Agilent Technologies). For protein purification ...
-
bioRxiv - Molecular Biology 2024Quote: The ATG (+1) codon of pKL-RLBP1 was mutated to an alanine codon (GCG) using the QuikChange Site-directed Mutagenesis kit (Agilent technologies) with the F primer and its reverse complement (Table S1 ...
-
bioRxiv - Cancer Biology 2024Quote: ... PCR products were purified with Agencourt AMPure XP beads and sample profile was analysed with the High Sensitivity D5000 kit (Agilent Technologies) on a TapeStation (Agilent Technologies) ...
-
bioRxiv - Plant Biology 2020Quote: ... RNA purity and integrity was examined using the NanoPhotometer® spectrophotometer (IMPLEN) and the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies). RNA concentration was measured with Qubit® RNA Assay Kit in Qubit® 2.0 Flurometer (Life Technologies) ...
-
bioRxiv - Systems Biology 2020Quote: ... The resulting cDNA library was assessed for yield and purity using an Agilent High Sensitivity DNA kit for Agilent 2100 Bioanalyzer (Agilent Technologies, CA). Template preparation with the cDNA libraries followed by ISP enrichment was performed using the Ion OneTouch2 system with Ion PGM™ Hi-Q™ OT2 kit (Product No ...
-
bioRxiv - Cancer Biology 2021Quote: ... Library concentrations as well as fragment size distributions were also analyzed by employing the Agilent Bioanalyzer High Sensitivity DNA Kit (Agilent: 5067-4626).
-
bioRxiv - Cancer Biology 2021Quote: ... Total RNA was extracted with Norgen single cell RNA purification kit (Norgen) and the quality was checked with a Bioanalyzer 2100 (Agilent, RIN >8.0). Ribosomic RNA was depleted with Ribo-Zero™ Gold Kit (Epicentre) ...
-
bioRxiv - Cell Biology 2021Quote: Measurements of aerobic respiration and glycolysis were conducted with the Seahorse Bioscience XFe-96 bioanalyzer using the Seahorse XF Cell Mito Stress Test Kit (Agilent #103015-100). Cells were seeded on XF96 cell culture microplates (Agilent #102416-100 ...
-
bioRxiv - Cancer Biology 2021Quote: ... RNA integrity and quantitation were assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). A total amount of 1 μg RNA per sample was used as input material for the RNA sample preparations ...
-
bioRxiv - Developmental Biology 2021Quote: ... Libraries were then quantified using a Nanodrop microvolume spectrophotometer (ng/μl) and quality was assessed using the Agilent High Sensitivity DNA Kit (Agilent -5067-4626) on a Bioanalyzer 2100 ...
-
bioRxiv - Cell Biology 2019Quote: Cell mitochondrial oxygen consumption rates (OCRs) were assayed in 96-well plates by using a XF Cell Mito Stress Test Kit (Cat. #: 101706100, Seahorse Bioscience, U.S.) on the XFe96 Extracellular Flux Analyzer (Seahorse Bioscience ...
-
bioRxiv - Cell Biology 2020Quote: Total RNA of CFs/HVPs co-culture and conditioned CFs exposed to co-culture medium was extracted using the Absolutely RNA Miniprep Kit (Agilent Technologies, USA) according to the manufacturer’s instructions and 1 μg was reverse transcribed using the High-Capacity cDNA Reverse Transcription kit (Thermo Fisher ...
-
bioRxiv - Cell Biology 2020Quote: ... 150 base pair oligos were chemically synthesized using proprietary Agilent technology and probes were labeled with either Cy3 or Cy5 dyes using the Genomic DNA ULS Labeling Kit (Agilent, 5190-0419). 40 ng of LAD and non-LAD probes were combined with hybridization solution (10% dextran sulfate ...
-
bioRxiv - Immunology 2021Quote: ... Following assessment of the quality of total RNA using Agilent 2100 bioanalyzer and RNA Nano Chip kit (Agilent Technologies, Santa Clara, CA), rRNA was removed from 2000 ng of total RNA with Ribo-Zero rRNA removal kit specific for Human/Mouse/Rat ...
-
bioRxiv - Genetics 2021Quote: ... To reproduce the A-variant the following primers were used for SDM by site directed mutagenesis using QuickChange II site directed mutagenesis kit (Agilent Technologies, UK) using the following primers ...
-
bioRxiv - Developmental Biology 2021Quote: ... RNA quality was assessed using an Agilent 2100 Bioanalyzer and the Agilent RNA 6000 Nano Kit (Agilent Technologies, Santa Clara, CA, USA). RNA was quantified using Qubit RNA BR Assay Kit (Invitrogen ...
-
bioRxiv - Cancer Biology 2020Quote: ... was fragmented to 200bp using a Covaris E Series and the resultant libraries were subjected to DNA Capture using SureSelect XT Mouse All Exon kit (Agilent, Stockport, Cheshire) following manufacturer’s instructions.
-
bioRxiv - Molecular Biology 2021Quote: ... The T695A and T656A mutations were generated in WT-YME1L1 plasmid via QuikChange Lightning Site-Directed Mutagenesis Kit (Agilent, Santa Clara, CA) and confirmed by sequencing ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... and stored at −80°C after verifying concentration and quality by spectrophotometer (Nanodrop, Thermo scientifics) and a Bioanalyzer (RNA 6000 Nano Kit, Agilent Technologies Inc). We produced libraries for these 21 individuals using the TruSeq RNA Library Prep Kit v2 (Illumina ...
-
bioRxiv - Developmental Biology 2021Quote: ... The mutated forms of the amplified sequence in which the potential m6A sites were replaced by cytidine (C) or guanine (G) were constructed using the QuikChange II XL Site-directed Mutagenesis Kit (Agilent Technologies, 200518). The fragments were separately inserted into the pCambia2300 vector ...
-
bioRxiv - Genomics 2020Quote: ... Samples were then cleaned up using Qiagen RNeasy Mini kit columns and their integrity was checked on Agilent 2200 Bioanalyzer (Agilent Technologies, USA). A total of 133 samples were selected for RNA sequencing (74 liver and 59 head kidney samples ...
-
bioRxiv - Genomics 2022Quote: ... and library profiles were assessed using a DNA High Sensitivity LabChip kit on an Agilent Bioanalyzer (Agilent Technologies, Santa Clara, CA, USA). The library was sequenced on an Illumina NovaSeq instrument (Illumina ...
-
bioRxiv - Molecular Biology 2020Quote: ... the purified products were cloned using the dual-colour selection Strataclone PCR cloning kit according to the manufacturer’s protocol (Stratagene, La Jolla, USA). Up to eight colonies containing the PCR product were selected and inoculated on Luria Bertani agar slants ...
-
Single-cell analysis of skeletal muscle macrophages reveals age-associated functional subpopulationsbioRxiv - Cell Biology 2022Quote: ... The cDNAs were then synthesized and their qualities assessed on the Agilent Bioanalyzer with High Sensitivity DNA kit (Agilent Cat# 5067-4626). cDNAs were then used for library preparation and the quality of the final libraries assessed on the Agilent Bioanalyzer with DNA 1000 kit (Agilent ...
-
bioRxiv - Genomics 2020Quote: ... the fragmented product is purified and then processed to generate sequencing-ready libraries using the SureSelectXT Library Preparation kit (Agilent, CA, USA) following manufacturer instructions ...
-
bioRxiv - Neuroscience 2020Quote: The point mutations and modifications in the linker sequence between CiVSD and FPs were done using the QuickCjhange II XL site-directed mutagenesis kit (Agilent Technologies, USA). The sequence verification of the novel constructs was done using Tag/dye-termination method (W ...
-
bioRxiv - Genomics 2019Quote: ... Samples were cleaned up using Qiagen RNeasy Mini kit columns and their integrity was checked on Agilent 2200 Bioanalyzer (Agilent Technologies, USA). Thereafter ...
-
bioRxiv - Developmental Biology 2019Quote: ... OCR and ECAR parameters were measured using the Seahorse XFp Cell Energy Phenotype Test Kit™ (Agilent Biotechnology, Cat No. 103275-100). Metabolic stress was induced by simultaneous treatment with 1μm Oligomycin and 0.125µM Carbonyl cyanide p-[trifluoromethoxy]-phenyl-hydrazone (FCCP).
-
bioRxiv - Immunology 2019Quote: Total RNA integrity was determined with the Agilent total RNA Pico Kit on a 2100 Bioanalyzer instrument (Agilent Technologies, Paolo Alto, USA). Library construction was performed with the “SMARTer® Stranded Total RNA-Seq Kit v2 - Pico Input Mammalian” (TaKaRa Bio USA ...
-
bioRxiv - Cell Biology 2020Quote: ... These DN proteins were generated by PCR-based mutagenesis using the QuikChange Lightning Multi Site-Directed mutagenesis kit (Stratagene, Santa Clara, USA) using pcDNA3.1(+ ...
-
bioRxiv - Cell Biology 2020Quote: pcDNA3 + mNICD W1758A: this plasmid was generated by PCR-based mutagenesis using the QuikChange Site-Directed mutagenesis kit (Stratagene, Santa Clara, USA) using pcDNA3 + mNICD as a template and the primers W1758A F and W1758A R.
-
bioRxiv - Cell Biology 2019Quote: ... Point mutations for amino acid substitutions or truncations were generated using the QuikChange site-directed mutagenesis kit (Stratagene, La Jolla, CA, USA).
-
bioRxiv - Genetics 2019Quote: ... Sequencing libraries then underwent a final cleanup and size selection using KAPA Pure Beads 0.55X-0.75X double-sided size selection and the average fragment size of the library was determined using the 2100 Bioanalyzer and high sensitivity DNA kit (Agilent #5067-4626). The quantity of sequenceable library for each sample was determined using the KAPA Library Quantification Kit (Roche #KK4835 ...
-
bioRxiv - Neuroscience 2019Quote: ... pcDNA3.1-HA-SorCS1cβ Y1132A and GFP-tagged Rab7 T22N were generated by in vitro mutagenesis using the QuikChange II Site-Directed Mutagenesis Kit (Agilent, Cat #200522) from pcDNA4-SorCS1cβ-myc (kindly provided by Alan D ...
-
bioRxiv - Biochemistry 2019Quote: ... and triple mutant D65K/E66K/E67K (DEE/KKK) – were generated by site-directed mutagenesis (Quick Change Lightning Site directed Mutagenesis Agilent Kit 210518) using the pLew100-TbBILBO1 plasmid and transfection of the Tb427 29.13 cell line [10] ...
-
bioRxiv - Cell Biology 2019Quote: The oxygen consumption rate (OCR) and the extracellular acidification rate (ECAR) were measured using the Mito Stress Test kit (Agilent, #103010-100), following the manufactureŕs instructions ...