Labshake search
Citations for Phenomenex :
101 - 150 of 226 citations for Zinc Finger Protein 50 ZNF50 Blocking Peptide since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... Peptides were purified by reversed-phase high-performance liquid chromatography on a C4 column (Phenomenex Jupiter C4, 5 μm, 300 Å, 250 × 10 mm) using a gradient of acetonitrile/water containing 0.1% TFA ...
-
bioRxiv - Biochemistry 2024Quote: ... Kinetex 2.6μ C18 100Å column 50×2.1 mm was purchased from Phenomenex (Torrance, CA). Animal studies were approved by the Institutional Animal Care and Use Committee and the Institutional Biosafety Committee of Vanderbilt University.
-
bioRxiv - Molecular Biology 2020Quote: ... the peptides were subjected to chromatographic separation in reverse phase using a C18 AQUA column (Phenomenex; beads diameter 5 μm; 75 μm x 100 mm). Both the pre-column and the analytical column were packed in house ...
-
bioRxiv - Biochemistry 2023Quote: Peptides were purified using a preparative C18 column (Aeris PEPTIDE 5 μm XB-C18, LC Column 250 x 21.2 mm, AXIA™ Packed, Phenomenex, flow rate 10 mL/min) in a Shimadzu LC-20AR solvent delivery system with a gradient of 20–70% B over 25 min ...
-
bioRxiv - Biochemistry 2023Quote: Analytical RP-HPLC on an analytical C18 column (Aeris 5 μm PEPTIDE XB-C18, 4.6 × 250 mm, 100 Å, Phenomenex, flow rate 1 mL/min) connected to a Shimadzu LC-40D solvent delivery system equipped with a SIL-40C autoinjector and an SPD-40D UV–vis detector was used to determine the purity of purified peptides ...
-
bioRxiv - Biochemistry 2022Quote: ... Sample separation occurred on a Kinetiex EVO C18 2.6 µM (2.1 × 50 mm column, Phenomenex) with a 0-8% gradient of acetronitrile with 100 mM ammonium bicarbonate as the solvent ...
-
bioRxiv - Neuroscience 2022Quote: ... and an Onyx Monolithic C18 analytical column (50 x 4.6 mm, Phenomenex, Torrance, CA, USA) eluting with 26% acetonitrile and 74% 100 mM HNa2PO4 pH 7.0 (v/v ...
-
bioRxiv - Plant Biology 2022Quote: ... equipped with Kinetex C18 (50 mm x 2.1 mm, 1.7 μm; Phenomenex Torrance, CA, USA). The LC system was linked to 6495 Triple Quad mass spectrometer (Agilent Technologies).
-
bioRxiv - Biophysics 2021Quote: The purified proteins were analyzed using BioSep SEC-s4000 (Phenomenex) particle size 5 μm ...
-
bioRxiv - Systems Biology 2023Quote: ... The MW was estimated using a protein mixture (Phenomenex AL03042), while a E.Coli 70s ribosome (NEB ...
-
bioRxiv - Microbiology 2023Quote: ... PF360-75-15-N-5, New Objective, 360 µm OD, 75 µm ID, 15 µm Tip PicoFrit Emitter; resin: 04A-4506, Phenomenex Aeris Peptide, C18 1.7 µm) via trapping column (column ...
-
bioRxiv - Microbiology 2020Quote: ... LC-MS was performed using a C-18 Kinetex analytical column (50 x 2.1 mm; Phenomenex). The presence of PalA was verified using MS/MS on an Agilent Technologies 6540 UHD Accurate-Mass QTOF LC-MS.
-
bioRxiv - Biochemistry 2019Quote: ... Compounds were separated on a Kinetex® EVO C18 column (2.6 μm, 2.1’ 50 mm, Phenomenex) using the following gradient of acetonitrile (B ...
-
bioRxiv - Physiology 2021Quote: Extracted samples were injected onto a Kinetex HILIC 50 x 4.6 mm 2.6 μm column (Phenomenex) connected to an Agilent 1290 HPLC system attached to a Q-Trap 5500 mass spectrometer (AB Sciex ...
-
bioRxiv - Biochemistry 2021Quote: ... Compounds were separated on a Kinetex® EVO C18 column (2.6 μm, 2.1 × 50 mm, Phenomenex) using a Dionex UltiMate 3000 chromatography system with the following gradient of acetonitrile (B ...
-
bioRxiv - Neuroscience 2022Quote: ... Chromatographic separation was achieved using a Kinetex XB C-18 (50 × 4.6 mm, 2.6 μm; Phenomenex) and a mobile phase consisting of 100 mM Na2HPO4 ...
-
bioRxiv - Neuroscience 2023Quote: ... Allopregnanolone was separated from interferents using a Luna 5u C8(2) 50×2 mm column (Phenomenex) kept at 35 °C using a column oven ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Chromatographic separation was conducted on a LC C-18 column (50 × 3 mm, 1.7 μm, Phenomenex) at 30°C ...
-
bioRxiv - Molecular Biology 2024Quote: ... equipped with a Luna Omega C18 100 Å (50 x 2.1 mm, 1.6 μm) column (Phenomenex) and Agilent 6490 Triple Quad LC/MS with iFunnel Technology ...
-
Rational domestication of a plant-based recombinant expression system expands its biosynthetic rangebioRxiv - Synthetic Biology 2021Quote: ... The purity of peptides was checked by MALDI-TOF-MS and analytic HPLC using a C18 column (Phenomenex, Jupiter® 5 µm, 300 Å, 150 × 2.0 mm).
-
bioRxiv - Cell Biology 2022Quote: ... normal-phase chromatography was performed with a Luna-5 mm NH2 column (50 mm × 4.60 mm, Phenomenex). Mobile phases were as follows ...
-
bioRxiv - Microbiology 2020Quote: ... Chromatographic separations were achieved using a 50 mm × 2.1 mm Kinetex 2.6 micron polar-C18 column (Phenomenex) held at a fixed temperature of 30 °C within an actively heated column compartment ...
-
bioRxiv - Microbiology 2023Quote: Protein samples were injected onto a Yarra 3 µm SEC-2000 (Phenomenex) running at room temperature in 150 mM NaCl ...
-
bioRxiv - Cancer Biology 2021Quote: ... Dried metabolites were resuspended in 50% ACN:water and loaded onto a Luna 3um NH2 100 A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on a Vanquish Flex (Thermo Scientific ...
-
bioRxiv - Cancer Biology 2021Quote: ... The LC separations were achieved using a LUNA C18 column (4 µm, 50 x 2.1 mm) from Phenomenex, Inc ...
-
bioRxiv - Plant Biology 2019Quote: ... methanol up to 40 μl and 2 μl per sample were injected onto a reversed-phase column (Kinetex C18 100A, length 50 mm, diameter 2.1 mm, particle size 1.7 μm; Phenomenex) and eluted using a 14.5 min gradient comprising 0.1% acetic acid in water (A ...
-
bioRxiv - Cancer Biology 2019Quote: ... A 10-µL aliquot of sample was injected onto a Kinetex C18 column (50 × 2.1 mm, 1.3 µm; Phenomenex) for chromatographic separation followed by multiple reaction monitoring detection by tandem mass spectrometry (MS/MS ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 50 × 1 mm; Phenomenex, Torrence, CA) and SenCell (2 mm glassy carbon electrode ...
-
bioRxiv - Molecular Biology 2021Quote: ... coupled to an strong cation exchange separation column (Luna SCX 5 μm – 100 Å particles, 50 × 2mm, Phenomenex), resulting in 24 fractions ...
-
bioRxiv - Immunology 2020Quote: Dried metabolites were resuspended in 50% ACN:water and 1/10th was loaded onto a Luna 3um NH2 100A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on a Vanquish Flex (Thermo Scientific ...
-
bioRxiv - Immunology 2022Quote: Dried MeOH extracts were resuspended in 50% ACN:water and 1/10th was loaded onto a Luna 3um NH2 100A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on a Vanquish Flex (Thermo Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... A 20 uL aliquot was injected onto a reverse phase C18 column (Kinetex 2.6u C18 100 A, 2.1 × 50 mm; Phenomenex). Phytohormones (ABA ...
-
bioRxiv - Genetics 2022Quote: ... 15 μL of sample was injected and separated on a 2.6 μm Kinetex XB-C18 100 A column (50 × 2.10 mm; Phenomenex) at 45°C ...
-
bioRxiv - Biochemistry 2022Quote: ... Phenomenex) and an analytical column (Kinetex 2.6 µm XB-C18, 100 Å, 50 × 0.3 mm microflow column, Phenomenex). The mobile phase consisted of water with 0.1% FA (phase A ...
-
bioRxiv - Microbiology 2022Quote: ... The column was a Gemini C18 (50 mm × 2 mm, 100 Å, particle size of 3-μm; Phenomenex). The mobile phases consisted of water (A ...
-
bioRxiv - Cancer Biology 2023Quote: ... Chromatographic separations were carried out at 40°C using a 2.6-µm C18 Kinetex column (50 X 2.1 mm) purchased from Phenomenex. The mobile phase flow rate was set to 0.5 mL/min and the following program applied for the elution ...
-
bioRxiv - Microbiology 2023Quote: ... ICT36007515F-50) filled with either Kinetex XB-C18 (particle size 1.7 µm, Pore Size 100 Å; Phenomenex, 4498) or Reprosil-Pur 120 C18-AQ (particle size 1.9 µm ...
-
bioRxiv - Molecular Biology 2023Quote: ... The reversed phase separation was performed with 2 µL lipid extract that was injected on a Kinetex C8 LC Column (50 x 2.1 mm, 2.6 um, Phenomenex) maintained at 50°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... A hydrophilic interaction liquid chromatography (HILIC) column (2.6 μm Kinetex HILIC 100, 50 × 4.6 mm, Phenomenex, Torrance, USA) was loaded with 10 μL of lipid extract ...
-
bioRxiv - Immunology 2024Quote: ... BAs mixture was separated on a Luna Omega 1.6 μm Polar (C18, 100 Å, 50 × 2.1 mm; Phenomenex) at 40°C ...
-
bioRxiv - Plant Biology 2024Quote: ... Each sample (1 µL) was then injected onto a reverse-phase column (Kinetex C18 100A, 50×2.1 mm, 1.7 μm; Phenomenex) and analyzed by the selected ion recording (SIR ...
-
bioRxiv - Molecular Biology 2024Quote: ... was determined using a UHPLC-MS Nexera-i LC-2040C instrument (Shimadzu, Kyoto, Japan) with a Kinetex PS-C18 column (50 × 2.1 mm, 2.6 um; Phenomenex). The samples were eluted with a linear gradient starting at 5% of solvent B (0.08% formic acid in MeCN ...
-
bioRxiv - Bioengineering 2020Quote: ... Extracts were cleared via 1 min of centrifugation at 16,100 x g and supernatants were further purified via a C18 SPE column (Strata C18-E, 50 mg; Phenomenex), pre-equilibrated with 1% acetic acid ...
-
bioRxiv - Cancer Biology 2021Quote: Resuspended metabolites were separated by hydrophilic interaction chromatography with a Gemini reverse-phase C18 column (50 mm × 4.6 mm with 5 μm diameter particles) from Phenomenex together with precolumn (C18 ...
-
bioRxiv - Synthetic Biology 2021Quote: ... The separation was performed using a RP column (Kinetex EVO C18; 50 × 2.1 mm; 1.7 μm; 100 Å, Phenomenex), a flow of 0.4 mL/min ...
-
bioRxiv - Microbiology 2021Quote: ... Chromatographic separation was performed using a Kinetex XB -C18 column (2.6 μm, 2.1 × 50 mm; Phenomenex, Utrecht, the Netherlands) held at 40°C ...
-
bioRxiv - Cell Biology 2021Quote: ... coupled to a strong cation exchange (SCX) separation column (Luna SCX 5 μm – 100 Å particles, 50 × 2mm, Phenomenex), resulting in 25 fractions.
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Imtakt Corporation) for EPI-589 and Kinetex XB-C18 100A column (5 μm, 50 mm × 2.1 mm i.d., Phenomenex Inc.) for edaravone ...
-
bioRxiv - Cancer Biology 2019Quote: ... Dried metabolites were resuspended in 50% ACN and 5 µl loaded onto a Luna 3 μm NH2 100 A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on an UltiMate 3000 RSLC (Thermo Scientific ...
-
bioRxiv - Microbiology 2019Quote: ... Liquid chromatography was performed using a ThermoScientific Vanquish UHPLC system fitted with 1.7 μm 100 Å Kinetex C8 column (50 × 2.1 mm) (Phenomenex). Data-dependent MS/MS (ddMS2 ...