Citations for Phenomenex :
1 - 50 of 53 citations for Respiratory syncytial virus RSV fusion protein exodomain human heterodimeric IgG1 Fc tag recombinant antigen since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2020Quote: ... A Synergi Fusion-RP column (Phenomenex® ...
-
bioRxiv - Molecular Biology 2019Quote: ... A Synergi Fusion-RP column (Phenomenex® ...
-
bioRxiv - Biochemistry 2020Quote: ... samples containing 100 ng recombinant protein were run over a 5 μm Jupiter C4 300Å LC column (Phenomenex, Torrance, California) using the 1260 Infinity LC system (Agilent Technologies ...
-
bioRxiv - Biophysics 2022Quote: ... Column: Synergi 4μ Fusion-RP by Phenomenex, 150 × 4.6 mm ...
-
bioRxiv - Biophysics 2022Quote: ... Column: Synergi 4 μ Fusion-RP by Phenomenex, 150 × 21.2 mm ...
-
bioRxiv - Molecular Biology 2023Quote: ... Nucleosides were separated using a Synergi Fusion-RP column (Synergi® 2.5 μm Fusion-RP 100 Å, 150 × 2.0 mm, Phenomenex®, Torrance, CA, USA) at a flow rate of 0.35 mL min−1 and a column temperature of 35 °C ...
-
bioRxiv - Molecular Biology 2023Quote: Nucleosides were separated using a Synergi Fusion-RP column (Synergi® 2.5 μm Fusion- RP 100 Å, 150 × 2.0 mm, Phenomenex®, Torrance, CA, USA). LC buffer consisting of 5 mM NH4OAc pH 5.3 (buffer A ...
-
bioRxiv - Microbiology 2024Quote: Nucleosides were separated using a Synergi Fusion-RP column (Synergi® 2.5 μm Fusion-RP 100 Å, 150 × 2.0 mm, Phenomenex®, Torrance, CA, USA). LC buffer consist of 5 mM NH4OAc pH 5.3 (buffer A ...
-
bioRxiv - Cell Biology 2021Quote: ... Reverse phase LC separation utilized a Synergi Fusion-RP column (Phenomenex) and a 3% to 100% methanol ramp over 50 min. ...
-
bioRxiv - Microbiology 2024Quote: ... while DAGs/TAGs were resolved using a Luna 5U C-5 column (Phenomenex) using established solvent systems.
-
bioRxiv - Biochemistry 2020Quote: ... and analyzed on a Synergi Fusion-RP column (Phenomenex, 150 x 4.6 mm) using the following conditions ...
-
bioRxiv - Biochemistry 2022Quote: ... with reverse-phase LC on a Synergi Fusion-RP column (Phenomenex, Torrence CA) at 35 °C ...
-
bioRxiv - Bioengineering 2021Quote: ... The column used was a Synergi 4 μm Fusion-RP 80Å C18 column (Phenomenex). Two solvents were used ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μm Fusion-RP 80 A (150 x 2 mm; Phenomenex # 00F-4424-B0) by the methods described below ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μm Fusion-RP 80 A (150 x 2 mm; Phenomenex # 00F-4424-B0) Pump B ...
-
bioRxiv - Cell Biology 2019Quote: ... Metabolites were separated using a Synergi 4µ Fusion-RP 80A column (100 × 4.6 mm, Phenomenex) on Agilent’s 1290 infinity series UHPLC system coupled to the mass spectrometer ...
-
bioRxiv - Biochemistry 2022Quote: ... Analytes were separated on a Synergi Fusion-RP column (Phenomenex, 100 × 4.6 mm, 4 µm) with a flow rate of 0.5 mL/min and an elution program consisting of 0% solvent B wash for 5 min ...
-
bioRxiv - Biochemistry 2021Quote: ... purified using a RP-PoraPak column and confirmed by HPLC (Phenomenex RP-Fusion C18 column) with a 10mM potassium phosphate (Buffer A ...
-
24-hour multi-omics analysis of residential sewage reflects human activity and informs public healthbioRxiv - Genomics 2019Quote: ... Chromatographic separation was performed using a Synergi Fusion C18 reversed phase column (2.1 × 150mm, 4um, Phenomenex). Samples were eluted at 0.25 mL/min with the following gradient ...
-
bioRxiv - Biochemistry 2024Quote: ... Analytes were separated on a Synergi Fusion-RP column (Phenomenex, 100 x 4.6 mm, 4 µm) with a flow rate of 0.5 mL/min and an elution program consisting of 5% solvent B for 3 min ...
-
bioRxiv - Biochemistry 2022Quote: ... extracted metabolites were separated using a Synergi 4-μm Fusion-RP 80 Å (150*4.6 mm, Phenomenex) LC column on Shimadzu Nexera UHPLC system ...
-
bioRxiv - Biochemistry 2022Quote: ... and 5–10 μl of digests were injected into an Agilent 1290 uHPLC system bearing a Synergi Fusion-RP column (100 × 2 mm, 2.5 μm, Phenomenex) at 35 °C with a flow rate of 0.35 ml/min and a solvent system consisting of 5 mM NH4OAc (Buffer A ...
-
Surveying the landscape of tRNA modifications by combining tRNA sequencing and RNA mass spectrometrybioRxiv - Biochemistry 2019Quote: ... 18 μl aliquots were mixed with 2 μl of 50 μM 15N-dA and 2.5-10 μl of digests were injected into a Agilent 1290 uHPLC system bearing a Synergi Fusion-RP column (100 × 2 mm, 2.5 μm, Phenomenex) at 35 °C with a flow rate 0.35 ml/min with a solvent system consisting of 5 mM NH4OAc (Buffer A ...
-
bioRxiv - Microbiology 2020Quote: ... The second fraction contained the most interesting compounds so only this sample was further purified by chromatography over a Synergi Fusion 4 micron C18 250 × 10 mm column (Phenomenex) using an Agilent 1100 series HPLC system fitted with a fraction collector and eluting at a flow rate of 3.5 ml min−1 with the following gradient ...
-
bioRxiv - Biochemistry 2021Quote: ... metabolites were separated chromatographically on a C18-based column with polar embedded groups (Synergi Fusion-RP, 150 × 2.0 mm, 4 µ, Phenomenex), using a Shimadzu Prominence LC20/SIL-20AC HPLC-autosampler coupled to the mass spectrometer ...
-
bioRxiv - Biochemistry 2022Quote: ... SeGlc-mBBr was purified by semi-preparative HPLC using a Synergi Fusion-RP column (Phenomenex, 250 × 10 mm, 4 µm) with a flow rate of 2.5 mL/min and elution consisting of a gradient of 0–40% solvent B for 15 min ...
-
bioRxiv - Plant Biology 2021Quote: HPLC was performed on an Agilent 1260 bioinert HPLC system using a Synergi Fusion-RP 80 Å (4.6 × 150 mm, 4 μm) (Phenomenex) column ...
-
bioRxiv - Plant Biology 2021Quote: Chromatography was performed on a Nexera XR 40 series HPLC (Shimadzu) using a Synergi 4µM Fusion-RP 80 Å 150×2mm column (Phenomenex). The column temperature was maintained at 40°C and the sample tray at 4°C ...
-
bioRxiv - Systems Biology 2023Quote: ... Metabolites were separated on Synergi 4-μm Fusion-RP 80 Å (150 × 4.6 mm) LC column (Phenomenex, 00F-4424-E0) using the Waters Acquity UPLC system ...
-
bioRxiv - Microbiology 2021Quote: ... a Synergin Hydro 4u Fusion-RP 80A column (150 mm x 2.00 mm diameter; 4-μm particle size) (Phenomenex, Torrance, CA) was used ...
-
bioRxiv - Plant Biology 2023Quote: Chromatography was performed on a Nexera XR 40 series HPLC (Shimadzu) using a Synergi 4 μM Fusion-RP 80 Å 150×2 mm column (Phenomenex). The method of determination of 2’3’cNMP is described in (43).
-
bioRxiv - Cell Biology 2023Quote: ... Chromatographic separation was achieved on a reverse phase (RP) column (Synergi Fusion 4µm, 150 mm x 2 mm, Phenomenex, Torrance, CA) using a gradient method (Table S3) ...
-
bioRxiv - Molecular Biology 2022Quote: ... For separation a Core-Shell Technology column (Synergi, 2.5 μm Fusion-RP, 100 Å, 100 × 2 mm column, Phenomenex, Torrance, CA, USA) at 35 °C and a flow rate of 0.35 mL/min were used in combination with a binary mobile phase of 5 mM NH4OAc aqueous buffer A ...
-
bioRxiv - Cell Biology 2019Quote: ... 5 µL of the nucleoside mixture were loaded on a Synergy Fusion RP column (4 mm particle size, 80Å pore size, 250 mm length, 2 mm inner diameter) from Phenomenex (Aschaffenburg, Germany) with 100% buffer A (5 mM NH4OAc pH 5.3 ...
-
bioRxiv - Microbiology 2021Quote: We performed the LC-MS/MS analysis on a reversed phase C18 column (Phenomenex Synergi Fusion, 2.1 x 150 mm, 4 µm) coupled via heated electrospray ionization (ESI ...
-
bioRxiv - Neuroscience 2022Quote: ... chromatography was carried out on a Synergy Fusion RP \SI 80 Å column (150 x 2.0 mm id, 4 µm, Phenomenex, Aschaffenburg, Germany) using the following solvent gradient (0.2 mL/min ...
-
bioRxiv - Biochemistry 2023Quote: ... The Nap1 peptide was lyophilized and further purified by reverse-phase high-performance liquid chromatography using a 250 × 10 mm 4mm Synergi Fusion-RP 80Å C12 column (Phenomenex, Torrance, CA), as previously described 48.
-
bioRxiv - Physiology 2024Quote: ... Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) analysis was performed with reverse-phase LC on a Synergi Fusion-RP column (Phenomenex, Torrence CA) at 35 °C ...
-
bioRxiv - Cell Biology 2019Quote: Chromatographic separation of the nucleosides was performed with an Easy-nLC1000 on an in-house packed column (100 µm inner diameter, 50 cm length, 4 μm Synergi Fusion 80 Å pore size from Phenomenex (Aschaffenburg, Germany) using a gradient from mobile phase A (5 mM ammonium formate pH 5.3 ...
-
bioRxiv - Developmental Biology 2022Quote: ... Nucleosides were then separated using Nexera LC-40 systems (Shimadzu) and Synergi™ Fusion-RP C18 column (4μm particle size, 250mm × 2mm, 80Å) (Phenomenex, 00G-4424-B0). Mobile phase was composed of 5mM ammonium acetate pH5.3 (solvent A ...
-
bioRxiv - Biophysics 2021Quote: The purified proteins were analyzed using BioSep SEC-s4000 (Phenomenex) particle size 5 μm ...
-
bioRxiv - Systems Biology 2023Quote: ... The MW was estimated using a protein mixture (Phenomenex AL03042), while a E.Coli 70s ribosome (NEB ...
-
bioRxiv - Microbiology 2023Quote: Protein samples were injected onto a Yarra 3 µm SEC-2000 (Phenomenex) running at room temperature in 150 mM NaCl ...
-
bioRxiv - Biophysics 2019Quote: ... The labeled protein was recovered on an S-2000 column (Phenomenex Biosep-SEC-S-2000) equilibrated in 50% MeOH and its mass confirmed by ESI-MS (PSC ...
-
bioRxiv - Cell Biology 2020Quote: ... Protein free supernatants were then injected into a Hypersil 3-μm ODS-C18 column (Phenomenex, USA) and eluted at 0.5 mL/min with a mobile phase consisting of 9% (v/v ...
-
bioRxiv - Systems Biology 2019Quote: ... Soluble protein (1.25 mg, 250 μL) was applied to a BioSep-SEC-s4000 gel filtration column (Phenomenex) equilibrated in PBS ...
-
bioRxiv - Systems Biology 2020Quote: ... Soluble protein (250 μL, 2 mg/mL) was applied to a BioSep-SEC-s4000 gel filtration column (Phenomenex) equilibrated in PBS ...
-
bioRxiv - Immunology 2022Quote: Trypsin-digested 6-Helix protein was then purified by high-pressure liquid chromatography (HPLC) on a C18 semi-preparative column (Phenomenex) over a 38-45% acetonitrile gradient in the presence of 0.1% trifluoroacetic acid ...
-
bioRxiv - Immunology 2023Quote: ... Aliquots of 100µL of plasma and tissue lysates were added to a protein precipitation plate (CE0-7565-R, Phenomenex, USA) along with 200µL of cold acetonitrile containing the deuterated internal standards ...
-
bioRxiv - Cell Biology 2020Quote: The digested proteins were desalted by running on a Strata X C18 SPE column (Catalog No. 8B-S100-AAK, Phenomenex, Torrance, CA) and then vacuum-dried ...