Labshake search
Citations for Phenomenex :
1 - 50 of 792 citations for Fipronil 3 Cyano Pyrazole 3 4 5 13C4 99%; 3 Cyano 5 15N2 98% 100 Ug Ml In Methanol since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: Quantification of energy metabolites and cofactors was performed using a cyano-phase LUNA column (50mm x 4.6mm, 5 µm; Phenomenex) with a 5.5 min run in negative ion mode with two separated runs ...
-
bioRxiv - Neuroscience 2024Quote: ... pentose phosphate pathway and Krebs cycle intermediates) was performed using a cyano–phase LUNA column (50 mm x 4.6mm, 5 µm; Phenomenex) by a 5 min run in negative ion mode ...
-
bioRxiv - Neuroscience 2024Quote: ... Negative ion mode analysis was conducted with a cyano–phase LUNA column (50 mm X 4.6 mm, 5 μm; Phenomenex) and 5 mM ammonium acetate pH 7 in MetOH as isocratic mobile phase in 5 min total run for each sample ...
-
bioRxiv - Cancer Biology 2022Quote: ... Quantification of different metabolites was performed using a cyano-phase LUNA column (50mm x 4.6mm, 5 µm; Phenomenex, Torrance, CA, USA) by a 5 min run in negative ion mode ...
-
bioRxiv - Physiology 2023Quote: ... Measurement of energy metabolites and cofactors was performed by using a cyano-phase LUNA column (50 mm × 4.6 mm, 5 µm; Phenomenex, Bologna, Italy), maintained at 53°C ...
-
bioRxiv - Cancer Biology 2022Quote: ... and 5 mg of C18 solid phase (3 μm, Durashell, Phenomenex). The HpHt column was sequentially washed with a series of 3 different solvents/solutions namely methanol ...
-
bioRxiv - Systems Biology 2023Quote: ... 4 3 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Biochemistry 2021Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Biochemistry 2020Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Cancer Biology 2019Quote: ... Dried metabolites were resuspended in 50% ACN and 5 µl loaded onto a Luna 3 μm NH2 100 A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on an UltiMate 3000 RSLC (Thermo Scientific ...
-
bioRxiv - Bioengineering 2022Quote: ... 3 mm x 100 mm column (Phenomenex, USA) was used for LC separation of the molecules ...
-
bioRxiv - Cell Biology 2022Quote: ... cofactors and nucleotides was performed by using a cyano-phase LUNA column (50mm x 4.6mm, 5µm; Phenomenex) by a 5 min run in negative ion mode with two separated runs ...
-
bioRxiv - Plant Biology 2023Quote: ... a StrataX 30 mg/3 mL spe-column (Phenomenex) was used.
-
bioRxiv - Neuroscience 2023Quote: ... The aminopropyl column (Luna 3 µm NH2, 2 × 100 mm, Phenomenex) was used for the chromatographic separation ...
-
bioRxiv - Systems Biology 2021Quote: ... and 4 x 3 mm ID Carbo-H guard (Phenomenex, Torrance, CA). The column was maintained at 50 °C and 1.5 mM H2SO4 was used as the mobile phase at a flow rate of 0.6 mL/min ...
-
bioRxiv - Cancer Biology 2022Quote: ... using a Gemini C18 column (250 mm × 3 mm, 3 μm, 110 Å; Phenomenex). Buffer A consisted of 20 mM ammonium formate pH 8.0 and Buffer B of 100% acetonitrile ...
-
bioRxiv - Microbiology 2024Quote: ... An Aqua 3u C18 125A (100×2.0mm 3 µm, Phenomenex, Torrance, USA) column was utilized ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Buffer was run at a flow rate of 0.6 mL/minute through a C8 column (Exlipse XDB-C8, 3 μm, 3.0×100 mm, Phenomenex). Dexamethasone was detected using UV absorbance at 240 nm and the assay had a linear range of 1.56 – 100 μg/mL (Supplemental Figure 14) ...
-
bioRxiv - Molecular Biology 2021Quote: Peptides were loaded onto a 100-μm fused silica (Polymicro Technologies) capillary column packed with 3 cm of 5-μm reverse-phase C18 resin (Aqua; Phenomenex), 4 cm of 5-μm strong cation exchange resin (Luna ...
-
bioRxiv - Microbiology 2023Quote: ... digested samples were loaded onto a fused silica capillary column with a 5-μm electrospray tip and packed in house with 18 cm of Luna C18 3 μM particles (Phenomenex). The column was then placed in line with a Q-exactive mass spectrometer (ThermoFisher ...
-
bioRxiv - Bioengineering 2020Quote: ... 3 μm particle size (Phenomenex, UK). Bexarotene (CAS ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μm (Phenomenex, Los Angeles, CA). The HPLC-reverse phase column was calibrated with acetyl-CoA (Sigma ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μm C-18 column (Phenomenex) kept at 35°C ...
-
bioRxiv - Immunology 2024Quote: ... 3 μm (Phenomenex, Los Angeles, California). The detailed protocol was described previously (44).
-
bioRxiv - Cell Biology 2021Quote: ... a 100 μm i.d capillary with a 5-μm pulled tip packed with 10 cm 3 μm Aqua C18 material (Phenomenex, Ventura, CA) followed by 3 cm 5-μm Partisphere strong cation exchanger (Whatman ...
-
bioRxiv - Microbiology 2023Quote: ... Separation was performed on a Gemini C18 analytical column (150 x 3 mm, 5 µm particle size, 110 Å pore size; Phenomenex) equipped with a C18 SecurityGuard column ...
-
bioRxiv - Microbiology 2020Quote: ... using a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) with 20 mM ammonium formate (pH 10.0 ...
-
bioRxiv - Molecular Biology 2022Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 × 1.0 mm, Phenomenex), resulting in 5 fractions.
-
bioRxiv - Neuroscience 2023Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 × 1.0 mm, Phenomenex)64.
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... to 2/98% over 2:50 min:sec on a Luna™ 5 µm C18 50x2.0 mm 100 A column (Phenomenex, Aschaffenburg, Germany). For MS/MS analyses in the positive electrospray ionisation mode on a Varian 1200 TSQ (Agilent Technologies ...
-
bioRxiv - Cell Biology 2021Quote: ... 3 μm column (Phenomenex, Torrance, CA, USA). Acetonitrile and 0.1% formic acid were applied for gradient elution with the flow rate of 500 µl/min ...
-
bioRxiv - Cell Biology 2022Quote: ... packed with 3 μm C18 resin (Phenomenex) using a gradient from 7% to 55% buffer B at a flow rate of 500 nL/min ...
-
bioRxiv - Developmental Biology 2022Quote: ... 3 μm particle size (Phenomenex, Torrance, CA)) column packed in-house in Pico-Frit (100 μm X 30 cm ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µm particle size (Phenomenex, Terrence, USA) at a flow rate of 300 nL/min using a 120 min gradient of 12-45% mobile phase B (acetonitrile + 0.1% formic acid) ...
-
bioRxiv - Biochemistry 2024Quote: ... coupled to a Gemini guard column (Phenomenex, 4 x 3 mm, catalog no.: AJ0-7597). The flow rate for the LC method was 0.5 mL/min ...
-
bioRxiv - Systems Biology 2021Quote: ... equipped with a Gemini C18 column (3 µm, 110 Å, 100 x 1.0 mm, Phenomenex), (66) ...
-
bioRxiv - Systems Biology 2020Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) (47).
-
bioRxiv - Biochemistry 2023Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) (77).
-
bioRxiv - Molecular Biology 2023Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) installed with a Gemini C18 ...
-
bioRxiv - Genomics 2023Quote: ... The column was a Gemini C18 column (3 m, 110 Å, 100 1.0 mm, Phenomenex) with a Gemini C18 ...
-
bioRxiv - Biochemistry 2024Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex)(81).
-
bioRxiv - Immunology 2022Quote: ... 300 × 7.8 mm i.d., 3 μm, 500 Å; SEC-3000, 300 × 7.8 mm i.d., 3 μm, 290 Å, Phenomenex, Netherlands) two-stage set-up was used ...
-
bioRxiv - Cancer Biology 2023Quote: ... Chromatographic separation of metabolites was achieved by hydrophilic interaction liquid chromatography (HILIC) using a Luna 3 NH2 column (150 mm x 2.1 mm, 3 μm, Phenomenex) in conjunction with a HILIC guard column (Phenomenex ...
-
bioRxiv - Plant Biology 2023Quote: ... The eluates were loaded onto Strata-X SPE columns (60 mg/3 mL; Phenomenex), pre-washed with 1 mL hexane ...
-
bioRxiv - Neuroscience 2020Quote: ... this biphasic column was connected to a 100 μm inner diameter-fused silica capillary (Polymicro Technologies) analytical column with a 3 μm pulled tip packed with 10 cm of 3 μm C18 resin (Phenomenex). The entire three-phase column was then laced in line with a 1,200 quaternary HPLC pump (Agilent Technologies ...
-
bioRxiv - Plant Biology 2021Quote: ... Secondary metabolites were separated on an Aqua 3 µm C18 column (150 x 2 mm, 3 µm particle size) equipped with a pre-column filter from Phenomenex. The mobile phase consisted of 1 mM aqueous ammonium acetate (A) ...
-
bioRxiv - Immunology 2020Quote: ... Labelled peptides were solubilized in 20 mM ammonium formate (pH 8.0) and separated on a Gemini C18 column (250 × 3 mm, 3 μm C18 110 Å pore size; Phenomenex). Using a DGP-3600BM pump system equipped with a SRD-3600 degasser (Thermo-Fisher) ...
-
bioRxiv - Microbiology 2020Quote: ... and the trap columns (3 cm x 150 μm i.d) were packed in-house with 3 μm Jupiter C18 particles (Phenomenex, Torrance). The long analytical column was placed in a column heater (Analytical Sales and Services ...
-
bioRxiv - Genetics 2021Quote: ... equipped with a Gemini C18 (3 mm, 100 mm x 2 mm) analytical column (Phenomenex, USA). An isocratic elution was applied with 80% acetonitrile-20% water and flow rate was set at 200 µL/min ...
-
bioRxiv - Systems Biology 2019Quote: ... Metabolites were separated on a Luna 3 µm NH2 100 Å (150 × 2.0 mm) column (Phenomenex). The flowrate was 300 µL/min ...