Labshake search
Citations for Phenomenex :
201 - 250 of 598 citations for Ciprofloxacin Hcl 100 Ug Ml In Methanol 2 3 Carboxyl 13C3 99%; Quinoline 15N 98% since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2020Quote: ... USA) equipped with a KinetexLJ C8 column (2.1 × 50 or 100 mm, 1.7 µm, 100 Å, Phenomenex, Torrance, CA, USA) injected with 0.5 or 1 µl samples ...
-
bioRxiv - Plant Biology 2019Quote: ... chromatography was carried out on an analytical Kinetex F5 column (100 × 2.1 mm2, 100 Å, 1.7 μm, Phenomenex, Aschaffenburg, Germany). Chromatography was performed with a flow rate of 0.4 mL/min using 0.1% formic acid in water (v/v ...
-
bioRxiv - Microbiology 2020Quote: ... 10 µL of extracts were chromatographed on Kinetex C18 column (2.6 µm C18 100 Å, 100 x 2.1 mm) (Phenomenex, USA) with column temperature set at 50°C and auto-sampler temperature was set at 4°C ...
-
bioRxiv - Plant Biology 2023Quote: ... the compounds were separated on a Kinetex C18 column (100 x 2.1 mm, 1.7 µm, 100 A, Phenomenex, Aschaffenburg, Germany) with a flow rate of 0.4 mL/min ...
-
bioRxiv - Neuroscience 2024Quote: ... and separated on a C18 column (100 mm × 2.1 mm, 2.6 µm particle size, 100 Å pore size; Phenomenex Inc.) in an UltiMate 3000 Rapid Separation System (ThermoFisher ...
-
bioRxiv - Microbiology 2021Quote: ... 100 mm x 2.1 mm (Phenomenex, Torrance, CA) and an UltiMate 3000 pump (Thermo Fisher ...
-
bioRxiv - Plant Biology 2021Quote: ... Separation was achieved on a Kinetex 1.7u XB-C18 column (100 × 2.1 mm, 1.7 µm, 100 Å, Phenomenex, Torrance, CA, USA). Formic acid (0.05 % ...
-
bioRxiv - Molecular Biology 2020Quote: ... Separation was achieved on a Kinetex 1.7u XB-C18 column (100 x 2.1 mm, 1.7 μm, 100 Å, Phenomenex, Torrance, CA, USA). Formic acid (0.05 % ...
-
bioRxiv - Synthetic Biology 2022Quote: ... The separation was done at 40 °C in a C18 column (Kinetex 2.6 μm C18 100 Å, 100 × 4.6 mm, Phenomenex, Torrance, USA) using isocratic elution for 10 min using acetone:water (70:30 ...
-
bioRxiv - Biochemistry 2019Quote: ... Separation was achieved on a Kinetex 1.7u XB-C18 column (100 x 2.1 mm, 1.7 µm, 100 Å, Phenomenex, Torrance, CA, USA) with 0.05% v/v formic acid in water and acetonitrile (with 0.05% formic acid ...
-
bioRxiv - Systems Biology 2020Quote: ... prepended with a guard cartridge (Kinetex, 100 × 2.1 mm, 1.7 μm particles size, 100 Å pore size; Phenomenex, Torrance, CA, USA), at a column compartment temperature of 40°C ...
-
bioRxiv - Plant Biology 2023Quote: ... Compounds were separated on a Kinetex® 1.7 μm EVO C18 100 Å column (100 x 2.1 mm, Phenomenex, Torrance, USA) applying an eluent flow rate of 0.3 mL/min and a column temperature of 40°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... Separation was achieved on a Kinetex XB-C18 column (100 x 2.1 mm, 1.7 μm, 100 Å, Phenomenex, Torrance, CA, USA). Formic acid (0.05% ...
-
bioRxiv - Biochemistry 2023Quote: ... Peptides were eluted and resolved by a gradient from 13 to 65% mobile phase B (95:5:0.1 CH3CN / H2O / HCOOH over 23 min on a 1 × 100 mm Luna Omega 1.6 μm 100 Å C18 column (Phenomenex, CA). A Tribrid Eclipse Orbitrap (OT ...
-
bioRxiv - Bioengineering 2022Quote: ... Separation was achieved on a Kinetex 1.7u XB-C18 column (100 x 2.1 mm, 1.7 μm, 100 Å, Phenomenex, Torrance, CA, USA). Formic acid (0.05% ...
-
bioRxiv - Plant Biology 2023Quote: ... dsGLS were analyzed by LC-MS/MS on an Advance UHPLC system (Bruker, Bremen, Germany) equipped with a Kinetex® XB-C18 column (100 × 2.1 mm, 1.7 μm, 100 Å, Phenomenex, USA) coupled to an EVOQ Elite TripleQuad mass spectrometer (Bruker ...
-
bioRxiv - Microbiology 2023Quote: ... A Kinetex EVO C18 reversed-phase column was applied for HPLC separations (100 mm × 2.1 mm I.D., 2.6 μm, 100 Å particles, Phenomenex, Torrance, CA, USA), which was maintained at 50 °C ...
-
bioRxiv - Molecular Biology 2023Quote: ... Peptides were eluted and resolved by a gradient from 13 to 65% mobile phase B (95:5:0.1 CH3CN / H2O / HCOOH) over 23 min on a 1 × 100 mm Luna Omega 1.6 μm 100 Å C18 column (Phenomenex, CA). A Tribrid Eclipse Orbitrap (OT ...
-
bioRxiv - Systems Biology 2021Quote: ... and 4 x 3 mm ID Carbo-H guard (Phenomenex, Torrance, CA). The column was maintained at 50 °C and 1.5 mM H2SO4 was used as the mobile phase at a flow rate of 0.6 mL/min ...
-
bioRxiv - Microbiology 2023Quote: Protein samples were injected onto a Yarra 3 µm SEC-2000 (Phenomenex) running at room temperature in 150 mM NaCl ...
-
bioRxiv - Molecular Biology 2024Quote: ... and a YarraTM 3 μm SEC-3000 (300 x 7.8 mm; Phenomenex), with a isocratic flow rate of 0.5 ml/min ...
-
bioRxiv - Cancer Biology 2021Quote: Data acquisition: 5 μL of sample was injected onto a Kinetex 2.6 μm 100 Å 100 × 2.1 mm (Phenomenex, #00A-4723-AN) using a SIL-30 AC auto sampler (Shimazdu ...
-
bioRxiv - Plant Biology 2020Quote: ... Samples were separated on a Kinetex XB-C18 column (100 × 2.1 mm ID, 1.7 µm particle size, 100 Å pore size; Phenomenex Inc., Torrance, CA) maintained at 40 °C with a flow rate of 0.3 mL min-1 and mobile phase consisting of 0.05% (v/v ...
-
bioRxiv - Physiology 2020Quote: ... Chromatographic separation was implemented by injecting 5 μL of samples on a Kinetex EVO C18 analytical column (100 × 2.1 mm, 100 Å, 5μm, Phenomenex Inc., CA, USA) under binary gradient conditions using mobile phase A (milliQ water containing 0.1% formic acid ...
-
bioRxiv - Plant Biology 2023Quote: ... Separation was achieved on a Kinetex® 1.7-μm C18 column (100 × 2.1 mm, 1.7 μm, 100 Å; Phenomenex, Torrance, CA, USA), including a SecurityGuard™ C18 guard column (2.1 mm ...
-
bioRxiv - Biochemistry 2023Quote: ... Desalted peptides were then separated on a reversed-phase analytical column (LUNA Omega Polar C18 Column, 100 Å, 1.6 µm, 100 mm × 1.0 mm, Phenomenex, Torrance, CA, USA) at a flow rate of 40 µL.min−1 using a 10–40% linear gradient of solvent B (A ...
-
bioRxiv - Systems Biology 2020Quote: ... 100 x 2.00 mm LC column (Phenomenex, Torrance, CA) kept at 25 °C ...
-
bioRxiv - Systems Biology 2020Quote: ... 100 x 2.00 mm LC column (Phenomenex, Torrance, CA) and introduced into the MS via an electrospray ionization source conjoined to an Exactive™ Plus Orbitrap Mass Spectrometer (Thermo Scientific) ...
-
bioRxiv - Plant Biology 2023Quote: ... A 100 × 2.1 mm 2.6μ Kinetex EVO column (Phenomenex) was used for separation using an acetonitrile versus 1% (v/v ...
-
bioRxiv - Biophysics 2023Quote: ... an Aeris 3.6 μm 100 Å XB-C18 (Phenomenex) or on a Kinetex Peptide biphenyl ...
-
bioRxiv - Physiology 2021Quote: ... Analyte separation was achieved using a gradient HPLC method and Luna 2.5u C18(2)-HST 50×2 mm column (Phenomenex) kept at 50°C with a Shimadzu CTO-20AC column oven.
-
bioRxiv - Microbiology 2022Quote: Reverse-phase chromatographic separations were performed on a Luna 2.5 μm C18(2)-HST column (100Å, 150 × 2 mm, Phenomenex) at a constant temperature of 40□°C ...
-
bioRxiv - Microbiology 2022Quote: ... with a Kinetex C18 biphenyl column (2.6 um 50 x 3 mm Phenomenex) at 45°C with 98% MS-grade water (Sigma-Aldrich) ...
-
bioRxiv - Biochemistry 2021Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Biochemistry 2020Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Molecular Biology 2022Quote: ... The trapping column (75 µm ID x length 3 µm Luna particles, Phenomenex) was run with 0.1% aqueous formic acid for 7 minutes at 5 µL/min ...
-
bioRxiv - Systems Biology 2023Quote: ... 0.3 mm inner diameter reversed phase column (Phenomenex, Luna Polar C18 3 um). A binary analytical gradient using 0.1 % formic acid in water (mobile phase A ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... using a Luna C18(2) column from Phenomenex (Torrance ...
-
bioRxiv - Microbiology 2020Quote: ... 2.5 μm Luna C18(2) HST column (Phenomenex) connected to an LC-20ADXR (Shimadzu ...
-
bioRxiv - Bioengineering 2022Quote: ... Biozen SEC-2 size exclusion chromatography column (Phenomenex) was employed in the high-performance liquid chromatography (HPLC ...
-
bioRxiv - Cancer Biology 2022Quote: ... 150 × 2 mm HPLC column (Phenomenex, Torrance, CA) as recently reported (PMID ...
-
bioRxiv - Cancer Biology 2022Quote: ... 150 × 2 mm HPLC column (Phenomenex, Torrance, CA) with isobaric separation (PMID ...
-
bioRxiv - Biochemistry 2020Quote: ... Luna 5 µm 100 Å strong cation exchange resin (Phenomenex) and a second layer of C18 resin using a high pressure chamber(Fonslow et al. ...
-
bioRxiv - Biochemistry 2023Quote: ... LC Column 100 x 4.6 mm (Phenomenex 00D-4043-E0) with normal phase chromatography ...
-
bioRxiv - Cell Biology 2019Quote: ... Reverse phase particles (Aqua C18, 3 mm dia., 125 Å pores, Phenomenex, Torrance, CA) were packed directly into the pulled column at 800 psi until they were 12-cm long ...
-
bioRxiv - Neuroscience 2020Quote: ... injected on a Yarra 3 μm SEC – 2000 column (300 x 7.8 mm, Phenomenex), and run at 0.7 ml/minute in 1x PBS ...
-
bioRxiv - Plant Biology 2021Quote: ... with the following modifications: a Lux 250 x 4.6mm 5u Cellulose-3 column (Phenomenex) was used ...
-
bioRxiv - Genetics 2019Quote: ... Reversed phase particles (Aqua C18, 3 □m dia., 125 Å pores, Phenomenex, Torrance, CA) were packed directly into the pulled column at 800 psi until 12 cm long ...
-
bioRxiv - Cell Biology 2023Quote: ... on a Yarra 3 µm SEC-2000 LC 300 x 4.6 mm column (Phenomenex) in 50 mM Tris-HCl ...
-
bioRxiv - Cell Biology 2020Quote: ... at 220nm and 100×4.6-mm cation exchange column (104CT0315, Phenomenex) at 418nm respectively on a HPLC machine (Agilent 1260 Infinity II) ...