Labshake search
Citations for Phenomenex :
1 - 50 of 697 citations for 8 2 5 dimethyl 4 chlorophenylsulfonamido 1 naphthol 3 6 disulfonic acid since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2020Quote: ... Samples were analyzed by isocratic elution using a 5 mM H2SO4 mobile phase at a constant flow rate of 0.5 mL min−1 on a REZEX ROA-organic acid H+ (8%) LC column (300 mm × 7.8 mm, Phenomenex). The column temperature was maintained at 55 °C and the refractive index detector was operated at 35 °C ...
-
bioRxiv - Microbiology 2021Quote: ... Rezex RFQ-Fast Acid H+ (8%) (Phenomenex) was used as the column and placed at 80 °C ...
-
bioRxiv - Microbiology 2023Quote: ... the column (Phenomenex, Rezex ROAOrganic Acid H+ (8%), LC column 300 x 7.8mm ...
-
bioRxiv - Synthetic Biology 2020Quote: ... with a REZEX 8 μL 8% H+ organic acid column (300 ×7.8 mm) (Phenomenex, CA, USA) operating at 65◦C using 0.01 N H2SO4 as a solvent at a flow rate of 0.6 mL min−1 ...
-
bioRxiv - Bioengineering 2019Quote: ... using a RezexTM ROA-Organic Acid H+ (8 %) column (Phenomenex). References were purchased from Sigma Aldrich ...
-
bioRxiv - Microbiology 2019Quote: ... using a RezexTM ROA-Organic Acid H+ (8 %) column (Phenomenex). References were purchased from Sigma Aldrich ...
-
bioRxiv - Systems Biology 2021Quote: ... Sugars and organic acids in the supernatant were measured with an isocratic Agilent 1200 series HPLC system equipped with a Phenomenex guard carbo-H column (4 by 3.0 mm) and a Rezex ROA organic acid H (8%) column (300 by 7.8 mm, 8 μm; Phenomenex) maintained at 50°C ...
-
bioRxiv - Bioengineering 2022Quote: ... The Rezex ROA-Organic Acid H+ (8%) column (Phenomenex Inc., Torrance, CA) was used and the columns were eluted with 5 mM H2SO4 at 50 °C ...
-
bioRxiv - Synthetic Biology 2023Quote: ... and Rezex ROA-Organic Acid H+ (8%) column (Phenomenex, Torrance, CA, USA). The column and detector were run at 50 °C ...
-
bioRxiv - Systems Biology 2023Quote: ... 4 3 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Bioengineering 2021Quote: ... separated using a Rezex™ ROA-Organic Acid H+ (8%) LC Column (Phenomenex) at 35 °C ...
-
bioRxiv - Microbiology 2024Quote: ... separated over an ion exchange column (Phenomenex Rezex RoA organic acid H+ (8%), LC column 300 x 7.8mm ...
-
bioRxiv - Molecular Biology 2019Quote: ... 3 μm (2.1 × 150 mm) column with Security Guard (4 × 2 mm) at 40°C (Phenomenex, Cheshire, UK). The standards and the samples (5 μl injection volume ...
-
bioRxiv - Microbiology 2021Quote: ... Samples were analysed on a C18 column (Kinetex 5 μM, C18 100 Å, 250 × 4·6 mm, Phenomenex, Utrecht, The Netherlands) using a gradient of water/methanol with 0·1% formic acid (0–3 min ...
-
bioRxiv - Cancer Biology 2023Quote: ... 4 x 2 mm (Phenomenex). The eluents were A ...
-
bioRxiv - Genetics 2021Quote: ... A Rezex RFQ-Fast Acid H+ (8%) LC column (100 × 7.8 mm; Phenomenex, USA) was equilibrated with 5 mM H2SO4 (Titrisol ...
-
bioRxiv - Synthetic Biology 2022Quote: ... equipped with Rezex™ ROA-Organic Acid H+ (8%) column (Phenomenex Inc., Torrance, CA) and a refractive index detector (RID) ...
-
bioRxiv - Bioengineering 2022Quote: ... equipped with pre-column and column Rezex ROA-Organic Acid H+ (8%) (Phenomenex, Germany). For compounds with UV absorption at 280 nm ...
-
bioRxiv - Synthetic Biology 2021Quote: ... Metabolites were separated using a Rezex™ ROA-Organic Acid H+ (8%) LC Column (Phenomenex) at 35 °C ...
-
bioRxiv - Bioengineering 2023Quote: ... Chromatography was done on a Rezex ROA-Organic Acid H+ (8%) column (Phenomenex Inc., Torrance, CA) maintained at 60 °C ...
-
bioRxiv - Microbiology 2023Quote: ... Shimadzu) equipped with Ion exclusion Rezex ROA-Organic Acid H+(8%) column (300x 7.8 mm; Phenomenex), along with a guard column (Phenomenex) ...
-
bioRxiv - Synthetic Biology 2023Quote: ... Agilent 1260 Infinity HPLC equipped with Rezex™ ROA-Organic Acid H+ (8%) column (Phenomenex Inc.) and a refractive index detector were used ...
-
bioRxiv - Biochemistry 2021Quote: ... equipped with a Rezex RFQ-Fast acid H+ (8%) 7.8% x 100 mm column (Phenomenex, Torrance, CA). The column was pre-heated to 85 °C and was operated by running 5 mM H2SO4 as a mobile phase at a flow rate of 1 mL/min ...
-
bioRxiv - Bioengineering 2023Quote: ... a Rezex ROA-Organic Acid H+ column 8 µm (300 x 7.8 mm; Phenomenex, Torrance, California, USA) in combination with a Security Guard HPLC Guard Cartridge system Carbo-H 4 x (4 x 3 mm ...
-
bioRxiv - Microbiology 2024Quote: ... All samples were then vortexed and centrifuged at 10,000 x g for 3 min at 4 ºC and then diluted 2-fold with buffer in conical polypropylene HPLC vials (Phenomenex, Torrance, CA) prior to mass spectrometry analysis.
-
bioRxiv - Cancer Biology 2023Quote: ... A Luna C18(2) C8 column (3 μm, 2 mm × 50 mm, Phenomenex) was used ...
-
bioRxiv - Systems Biology 2022Quote: ... equipped with a refractive index detector using a Rezex ROA Organic Acid H+ (8%) column (Phenomenex Inc. Germany). The column was eluted with 0.005 N of H2SO4 at a flow rate of 0.6 mL/min at 50°C65 ...
-
bioRxiv - Microbiology 2023Quote: ... Shimadzu) equipped with an Ion exclusion Rezex ROA-Organic Acid H+(8%) column (300 × 7.8 mm column, Phenomenex), along with a guard column (Phenomenex) ...
-
bioRxiv - Microbiology 2023Quote: ... A Phenomenex RezexTM ROA-Organic Acid H+ (8%) column (150 x 4.6 mm, Phenomenex Inc., Torrance, CA, USA) was used ...
-
bioRxiv - Microbiology 2019Quote: ... Luna-NH2 column (3 μm, 150 × 2 mm, Phenomenex) was used flowing at 0.4 mL/min ...
-
bioRxiv - Biochemistry 2023Quote: ... then packed first with 8 cm of 5 µm C18 RP particles (Aqua, Phenomenex), followed by 3.5 cm of 5 µm Luna SCX (Phenomenex) ...
-
bioRxiv - Bioengineering 2024Quote: Sugar and organic acid were analyzed on Rezex RHM-Monosaccharide H+ (8%) column (300 x 7.8 mm) (Phenomenex, USA) at 40⁰C using 5 mM H2SO4 as the eluent with the flow rate 0.5 ml/min ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 50 × 1 mm; Phenomenex, Torrence, CA) and SenCell (2 mm glassy carbon electrode ...
-
bioRxiv - Cancer Biology 2022Quote: ... and 5 mg of C18 solid phase (3 μm, Durashell, Phenomenex). The HpHt column was sequentially washed with a series of 3 different solvents/solutions namely methanol ...
-
bioRxiv - Systems Biology 2021Quote: ... and 4 x 3 mm ID Carbo-H guard (Phenomenex, Torrance, CA). The column was maintained at 50 °C and 1.5 mM H2SO4 was used as the mobile phase at a flow rate of 0.6 mL/min ...
-
bioRxiv - Systems Biology 2022Quote: ... Organic acids and alcohols were analysed by HPLC (Shimadzu Prominence-I LC-2030 plus system) using a Rezex™ ROA-Organic Acids H+ (8%) 300 × 7.8 mm column (00H-0138-K0; Phenomenex) and a guard column (03B-0138-K0 ...
-
bioRxiv - Synthetic Biology 2020Quote: ... A Phenomenex Rezex™ ROA-Organic Acid H+ (8%) (30 x 4.6 mm; CAT#: 00A-0138-E0, Phenomenex, Torrance, CA) was used for a 30 minute isocratic separation using a mobile phase of 5 mM H2SO4 ...
-
bioRxiv - Bioengineering 2024Quote: ... Organic acids and alcohols were analysed by HPLC (Shimadzu Prominence-I LC-2030 plus system) using a Rezex™ ROA-Organic Acids H+ (8%) 300 ×7.8 mm column (00H-0138-K0; Phenomenex) and a guard column (03B-0138-K0 ...
-
bioRxiv - Neuroscience 2023Quote: ... The aminopropyl column (Luna 3 µm NH2, 2 × 100 mm, Phenomenex) was used for the chromatographic separation ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 cm of 5-μm strong cation exchange resin (Luna; Phenomenex), and 8 cm of reverse-phase C18 resin57 ...
-
bioRxiv - Systems Biology 2020Quote: ... machine with a UV Diode Array Detector SPD-M30A NexeraX2 or/and a Refractive Index Detector RID 20A and an analytical ion-exclusion Rezex ROA-Organic Acid H+(8%) column (250×4.6 mm) with guard column (Phenomenex, Torrance, USA) (5 mM H2SO4 in MilliQ water (18.2 MΩ),isocratic ...
-
bioRxiv - Systems Biology 2020Quote: ... machine with a UV Diode Array Detector SPD-M30A NexeraX2 or/and a Refractive Index Detector RID 20A and an analytical ion-exclusion Rezex ROA-Organic Acid H+(8%) column (250×4.6 mm) with guard column (Phenomenex, Torrance, USA) (5 mM H2SO4 in MilliQ water (18.2 MΩ) ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 150 × 2 mm; Phenomenex, Torrence, CA), guard column (BDS-Hypersil-C18 ...
-
bioRxiv - Bioengineering 2020Quote: ... a Rezex ROA-Organic Acid H+ (8%) Analysis HPLC Column (Cat #: #00H-0138-K0, Phenomenex, Inc., Torrance, CA, 300 x 7.8 mme;) was employed for the separation of xylose and xylitol ...
-
bioRxiv - Biochemistry 2021Quote: ... were carried out using an RSLC system (Dionex) equipped with a 100 × 7.8 mm Rezex RFQ-Fast Acid H+ (8%) (Phenomenex, Torrance, CA, USA) column operated at 85 °C ...
-
bioRxiv - Systems Biology 2021Quote: ... and metabolites subsequently quantified using the Dionex 2000 HPLC system (Dionex, Idstein, Germany) with a Rezex ROA-Organic Acid H + (8%, Phenomenex, Aschaffenburg, Germany) and a RI-101 detector (Shodex ...
-
bioRxiv - Microbiology 2020Quote: ... The HPLC system was equipped with a Refractive Index Detector (Alliance HPLC with 2414 RID, Waters, Eschborn, Germany) and a Rezex ROA-Organic Acid H+ (8%) column (Phenomenex, Aschaffenburg, Germany) which was held at 65 °C during all measurements ...
-
bioRxiv - Microbiology 2022Quote: ... The analytical separation was achieved with a Rezex ROA-Organic Acid H+ (8%) (150 × 7.8 mm) ion exclusion column (Phenomenex, Torrance, CA, USA) using an isocratic mobile phase of acidified water (pH 2.1 ...
-
bioRxiv - Biochemistry 2021Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Biochemistry 2020Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...