Labshake search
Citations for Phenomenex :
151 - 200 of 404 citations for 7 Chloro 3 4 2 hydroxyethyl 1 piperazinyl 1 2 propoxyethyl pyrido 3 4 b pyrazin 2 1H one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... and 5–10 μl of digests were injected into an Agilent 1290 uHPLC system bearing a Synergi Fusion-RP column (100 × 2 mm, 2.5 μm, Phenomenex) at 35 °C with a flow rate of 0.35 ml/min and a solvent system consisting of 5 mM NH4OAc (Buffer A ...
-
bioRxiv - Microbiology 2020Quote: Approximately 250 mL of concentrated crude yeast AI-2 mimic preparation was filtered through a 0.45 μm PVDF filter (MilliporeSigma) and separated on a 2 × 25-cm Luna C18 column (Phenomenex) using a mobile phase consisting of 5% water in methanol at a flow rate of 10 mL/min ...
-
Surveying the landscape of tRNA modifications by combining tRNA sequencing and RNA mass spectrometrybioRxiv - Biochemistry 2019Quote: ... 18 μl aliquots were mixed with 2 μl of 50 μM 15N-dA and 2.5-10 μl of digests were injected into a Agilent 1290 uHPLC system bearing a Synergi Fusion-RP column (100 × 2 mm, 2.5 μm, Phenomenex) at 35 °C with a flow rate 0.35 ml/min with a solvent system consisting of 5 mM NH4OAc (Buffer A ...
-
bioRxiv - Microbiology 2023Quote: Protein samples were injected onto a Yarra 3 µm SEC-2000 (Phenomenex) running at room temperature in 150 mM NaCl ...
-
bioRxiv - Microbiology 2024Quote: ... An Aqua 3u C18 125A (100×2.0mm 3 µm, Phenomenex, Torrance, USA) column was utilized ...
-
bioRxiv - Molecular Biology 2024Quote: ... and a YarraTM 3 μm SEC-3000 (300 x 7.8 mm; Phenomenex), with a isocratic flow rate of 0.5 ml/min ...
-
bioRxiv - Systems Biology 2021Quote: ... Samples were then acidified to pH of ~2 by addition of 10% TFA and desalted using Strata SPE columns (Phenomenex). Desalted peptides were lyophilized to dryness in a SpeeVac (Thermo) ...
-
bioRxiv - Microbiology 2021Quote: ... The deuterated mixture was then digested online by using the same nepenthesin-2 column and the resultant peptides were desalted with flow through on a trap column (Phenomenex UHPLC fully Porous Polar C18 ...
-
bioRxiv - Neuroscience 2022Quote: ... The filtered samples were transferred into 2 mL amber LC-MS vials (Phenomenex, Torrance, CA, USA; Cat #AR0-3911-13) with pre-slit caps (Phenomenex ...
-
bioRxiv - Microbiology 2020Quote: ... 10% trifluoroacetic acid was added to the solution to bring the pH of the sample less than 2 before desalting and peptide isolation using Strata-X reverse phase resin (Phenomenex). Sample were dried under reduced pressure ...
-
bioRxiv - Microbiology 2020Quote: ... a C18 core-shell column (Kinetex, 50 × 2 mm, 1.8 um particle size, 100 A pore size, Phenomenex, Torrance, USA) with a flow rate of 0.5 mL/min (Solvent A ...
-
bioRxiv - Biochemistry 2021Quote: ... Large scale CdnG product and intermediate were purified using a Waters 1525 HPLC system with a reversed phase Luna C18(2) column (250 x 2mm; Phenomenex) with a flow rate of 0.3 ml/min ...
-
bioRxiv - Neuroscience 2023Quote: ... retention time of the nonradioactive reference compound by coinjection using a Luna 5 μm C18(2) 100 Å (250 mm×4.6 mm) column (Phenomenex) using acetonitrile and water (60:40 ...
-
bioRxiv - Neuroscience 2023Quote: ... The identities of the final products were confirmed by comparison with the HPLC retention time of the nonradioactive reference compound by coinjection using a Luna 5 μm C18(2) 100 Å (250 mm × 4.6 mm) column (Phenomenex) using acetonitrile and water (60:40 ...
-
bioRxiv - Cell Biology 2023Quote: ... Chromatographic separation was performed on a C18 column (Gemini 5 μm C18 110 Å Column, 250 x 2 mm, 5μm, Phenomenex) using the solvent gradient described in Table S5 ...
-
bioRxiv - Synthetic Biology 2023Quote: ... Gas tight 2 mL glass vials (AR0-37L0-13) and verex seals (AR0-5760-13) used to crimp vials were from Phenomenex.
-
bioRxiv - Neuroscience 2024Quote: ... retention times of the nonradioactive reference compounds obtained by coinjection using a Luna 5 μm C18(2) 100 Å (250 mm×4.6 mm) column (Phenomenex) with acetonitrile and water (60:40 ...
-
bioRxiv - Microbiology 2022Quote: ... with a Kinetex C18 biphenyl column (2.6 um 50 x 3 mm Phenomenex) at 45°C with 98% MS-grade water (Sigma-Aldrich) ...
-
bioRxiv - Biochemistry 2021Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Biochemistry 2020Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Molecular Biology 2022Quote: ... The trapping column (75 µm ID x length 3 µm Luna particles, Phenomenex) was run with 0.1% aqueous formic acid for 7 minutes at 5 µL/min ...
-
bioRxiv - Systems Biology 2023Quote: ... 0.3 mm inner diameter reversed phase column (Phenomenex, Luna Polar C18 3 um). A binary analytical gradient using 0.1 % formic acid in water (mobile phase A ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 cm of 5-μm strong cation exchange resin (Luna; Phenomenex), and 8 cm of reverse-phase C18 resin57 ...
-
bioRxiv - Microbiology 2020Quote: ... a C18 porous core column (Kinetex C18, 50 x 2 mm, 1.8 um particle size, 100 Angstrom pore size, Phenomenex, Torrance, USA) was used ...
-
bioRxiv - Biophysics 2021Quote: ... using an ESI-IT-TOF-LC-MS system (Shimadzu, Japan) with a C12 Jupiter Proteo column (150 × 2 mm, 4μm, 90 Å; Phenomenex, USA).
-
bioRxiv - Biochemistry 2022Quote: ... coupled to a strong cation exchange (SCX) separation column (Luna SCX 5 μm to 100 Å particles, 50 × 2 mm, Phenomenex). The 22 SCX fractions of DSSO were analyzed using an Ultimate3000 (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2022Quote: ... coupled to a strong cation exchange (SCX) separation column (Luna SCX 5 μm to 100 Å particles, 50×2 mm, Phenomenex), resulting in 24 fractions ...
-
bioRxiv - Cell Biology 2023Quote: ... Chromatographic separation was achieved on a reverse phase (RP) column (Synergi Fusion 4µm, 150 mm x 2 mm, Phenomenex, Torrance, CA) using a gradient method (Table S3) ...
-
bioRxiv - Microbiology 2024Quote: ... The active fractions 12-16 were combined and further fractionated using a reversed-phase preparative HPLC column (Phenomenex Luna C18 (2), 250 × 21.2 mm ...
-
bioRxiv - Microbiology 2024Quote: ... The filtered extract was directly injected onto a reversed-phase preparative high-performance liquid chromatography (HPLC) column (Phenomenex Luna C18 (2), 250 × 21.2 mm ...
-
bioRxiv - Cancer Biology 2024Quote: ... Liquid chromatography separation was achieved on a Synergy Hydro-RP column (100 mm × 2 mm, 2.5 µm particle size, Phenomenex, Torrance, CA), using reversed-phase chromatography with the ion pairing agent tributylamine in the aqueous mobile phase to enhance retention and separation ...
-
bioRxiv - Biochemistry 2021Quote: SILAC-TMT labeled peptides were pre-fractionated by high pH reverse phase liquid chromatography using an Agilent 1100 HPLC system with Gemini C18 reverse phase column (2 × 150 mm, 5 µM, 110 Å; Phenomenex Inc.) with solvents A (10 mM ammonium formate ...
-
bioRxiv - Microbiology 2021Quote: ... 5 µL of the samples were injected for UHPLC separation on a C18 core-shell column (Kinetex, 50 x 2 mm, 1.8-um particle size, 100 A-pore size, Phenomenex, Torrance, CA, USA). For the mobile phase ...
-
bioRxiv - Molecular Biology 2022Quote: ... For separation a Core-Shell Technology column (Synergi, 2.5 μm Fusion-RP, 100 Å, 100 × 2 mm column, Phenomenex, Torrance, CA, USA) at 35 °C and a flow rate of 0.35 mL/min were used in combination with a binary mobile phase of 5 mM NH4OAc aqueous buffer A ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... and a DGU-20A3-3channel in-line degasser and Controller (Columbia, MD) with a 100 mm x 2 mm Luna C18 reverse phase column (Phenomenex, Torrance CA) at ambient temperature ...
-
bioRxiv - Cell Biology 2019Quote: ... Reverse phase particles (Aqua C18, 3 mm dia., 125 Å pores, Phenomenex, Torrance, CA) were packed directly into the pulled column at 800 psi until they were 12-cm long ...
-
bioRxiv - Neuroscience 2020Quote: ... injected on a Yarra 3 μm SEC – 2000 column (300 x 7.8 mm, Phenomenex), and run at 0.7 ml/minute in 1x PBS ...
-
bioRxiv - Plant Biology 2021Quote: ... with the following modifications: a Lux 250 x 4.6mm 5u Cellulose-3 column (Phenomenex) was used ...
-
bioRxiv - Microbiology 2020Quote: ... using a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) with 20 mM ammonium formate (pH 10.0 ...
-
bioRxiv - Genetics 2019Quote: ... Reversed phase particles (Aqua C18, 3 □m dia., 125 Å pores, Phenomenex, Torrance, CA) were packed directly into the pulled column at 800 psi until 12 cm long ...
-
bioRxiv - Molecular Biology 2022Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 × 1.0 mm, Phenomenex), resulting in 5 fractions.
-
bioRxiv - Neuroscience 2023Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 × 1.0 mm, Phenomenex)64.
-
bioRxiv - Cell Biology 2023Quote: ... on a Yarra 3 µm SEC-2000 LC 300 x 4.6 mm column (Phenomenex) in 50 mM Tris-HCl ...
-
bioRxiv - Plant Biology 2023Quote: ... The eluates were loaded onto Strata-X SPE columns (60 mg/3 mL; Phenomenex), pre-washed with 1 mL hexane ...
-
bioRxiv - Molecular Biology 2020Quote: ... packed with 4 μm Hydro-RP 80 Å (Phenomenex cat # 04A-4375), as previously described (80) ...
-
bioRxiv - Microbiology 2023Quote: ... packed with 4 μm Hydro-RP 80 Å (Phenomenex cat # 04A-4375), as previously described 73 ...
-
bioRxiv - Biochemistry 2021Quote: ... The separation was performed on the C18 column Luna 5 μm (2) 100 A 250 x 4.5 mm (Phenomenex Inc., Torrance, CA, USA).
-
bioRxiv - Systems Biology 2021Quote: ... equipped with a Gemini C18 column (3 µm, 110 Å, 100 x 1.0 mm, Phenomenex), (66) ...
-
bioRxiv - Systems Biology 2020Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) (47).
-
bioRxiv - Molecular Biology 2023Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) installed with a Gemini C18 ...