Labshake search
Citations for Phenomenex :
1 - 50 of 634 citations for 7 Chloro 1 3 dihydro 5 phenyl 2H 1 4 benzodiazepin 2 thione since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2021Quote: Analyte separation was achieved using a Gemini 3u C6-Phenyl 110A 100×2 mm column (Phenomenex) kept at 35 °C using a Shimadzu CTO-20AC column oven ...
-
bioRxiv - Neuroscience 2019Quote: ... and 2µl was injected onto a 50m x 0.25mm (5% phenyl-arylene, 95% dimethylsiloxane) column with a 0.25µm ZB-5MS stationary phase (Phenomenex, Macclesfield, UK). Full-scan spectra were collected at three scans per second over a range of 50 to 650 m/z ...
-
bioRxiv - Microbiology 2019Quote: ... as well as a Kinetex Phenyl-hexyl column (50 × 2.1 mm, 1.7 µm, 100 Å, Phenomenex, for phenazine-1-carboxylic acid). Elution gradient ...
-
bioRxiv - Systems Biology 2023Quote: ... 4 3 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 50 × 1 mm; Phenomenex, Torrence, CA) and SenCell (2 mm glassy carbon electrode ...
-
bioRxiv - Genetics 2024Quote: The chromatographic separation of MMA and LA was performed with a 3 µm analytical column Phenomenex Gemini C6-Phenyl 100×2.0 mm (Phenomenex, Torrance, CA, USA). Solvent A and B were consisted of 0.1% formic acid in water and acetonitrile ...
-
bioRxiv - Zoology 2022Quote: ... into an injector heated at 280 ºC in splitless mode and then in a column compound of 5% Phenyl - 95% Dimethylpolysiloxane (Zebron ZH-5HT inferno, 30 m × 0.25 mm × 0.25 µm, Phenomenex, Torrance, CA, USA). The gas vector was helium at 1.2 ml min-1 ...
-
bioRxiv - Molecular Biology 2019Quote: ... 3 μm (2.1 × 150 mm) column with Security Guard (4 × 2 mm) at 40°C (Phenomenex, Cheshire, UK). The standards and the samples (5 μl injection volume ...
-
bioRxiv - Cancer Biology 2023Quote: ... 4 x 2 mm (Phenomenex). The eluents were A ...
-
bioRxiv - Systems Biology 2022Quote: ... RP-HPLC purification was performed on a Shimadzu LC-8A system equipped with a Rheodyne 3725i preparative sample injector (20 mL loop) and a semi-prep Luna 5 μm Phenyl-Hexyl RP-HPLC column (Phenomenex 00G-4257-P0-AX; 5 μm, 100Å; 2.1 x 25cm). The sample was eluted using a 15 – 40 % B gradient over 50 min at a flow rate of 25 mL/min at 60 °C (buffer A ...
-
bioRxiv - Microbiology 2024Quote: ... All samples were then vortexed and centrifuged at 10,000 x g for 3 min at 4 ºC and then diluted 2-fold with buffer in conical polypropylene HPLC vials (Phenomenex, Torrance, CA) prior to mass spectrometry analysis.
-
bioRxiv - Cancer Biology 2023Quote: ... A Luna C18(2) C8 column (3 μm, 2 mm × 50 mm, Phenomenex) was used ...
-
bioRxiv - Microbiology 2019Quote: ... Luna-NH2 column (3 μm, 150 × 2 mm, Phenomenex) was used flowing at 0.4 mL/min ...
-
bioRxiv - Cancer Biology 2022Quote: ... and 5 mg of C18 solid phase (3 μm, Durashell, Phenomenex). The HpHt column was sequentially washed with a series of 3 different solvents/solutions namely methanol ...
-
bioRxiv - Neuroscience 2022Quote: ... reconstituted in 100 µl acetonitrile: water (4:1) and filtered through 4 mm x 0.2 µm disks (Phenomenex, Australia) into LC vials ...
-
bioRxiv - Systems Biology 2021Quote: ... and 4 x 3 mm ID Carbo-H guard (Phenomenex, Torrance, CA). The column was maintained at 50 °C and 1.5 mM H2SO4 was used as the mobile phase at a flow rate of 0.6 mL/min ...
-
bioRxiv - Neuroscience 2023Quote: ... The aminopropyl column (Luna 3 µm NH2, 2 × 100 mm, Phenomenex) was used for the chromatographic separation ...
-
bioRxiv - Microbiology 2024Quote: ... Sub-fraction 7 (25 mg) was subjected to reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 cm of 5-μm strong cation exchange resin (Luna; Phenomenex), and 8 cm of reverse-phase C18 resin57 ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 150 × 2 mm; Phenomenex, Torrence, CA), guard column (BDS-Hypersil-C18 ...
-
bioRxiv - Biochemistry 2021Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Biochemistry 2020Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Cancer Biology 2023Quote: ... using a Synergi HydroRP column (250 x 2; 4 µm, Phenomenex) and 0.1 % of formic acid in water and methanol as mobile phases ...
-
bioRxiv - Plant Biology 2021Quote: ... Secondary metabolites were separated on an Aqua 3 µm C18 column (150 x 2 mm, 3 µm particle size) equipped with a pre-column filter from Phenomenex. The mobile phase consisted of 1 mM aqueous ammonium acetate (A) ...
-
bioRxiv - Bioengineering 2023Quote: ... in combination with a Security Guard HPLC Guard Cartridge system Carbo-H 4 x (4 x 3 mm; Phenomenex, Torrance, California, USA) as pre-column was used at 80 °C ...
-
bioRxiv - Developmental Biology 2024Quote: ... metabolites were separated using a Phenomenex Gemini C6-Phenyl (3µm, 100 x 2mm) column (Phenomenex, Torrance, CA, USA) via a gradient method consisting of mobile phase A ...
-
bioRxiv - Neuroscience 2023Quote: ... LC Column (150 × 2 mm, 3 μm particle size; Phenomenex, 00F-4377-B0). Chromatographic separation was achieved using the following conditions ...
-
bioRxiv - Biochemistry 2024Quote: ... coupled to a Gemini guard column (Phenomenex, 4 x 3 mm, catalog no.: AJ0-7597). The flow rate for the LC method was 0.5 mL/min ...
-
bioRxiv - Biochemistry 2024Quote: ... The tryptic peptides were loaded at 5 μl/min onto a C18 nano trap RP-1 column (Phenomenex, 10×0.075 mm, 5 μm) and separated with BioZen columns (Phenomenex Peptide Polar-C18 ...
-
bioRxiv - Neuroscience 2022Quote: Dried metabolites were resuspended in 50% ACN:water and 1/10th was loaded onto a Luna 3 μm NH2 100A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation under HILIC conditions was performed on a Vanquish Flex (Thermo Scientific ...
-
bioRxiv - Immunology 2021Quote: ... column Gemini 3 µM C18 HPLC column (150 × 2 mm ID, Phenomenex, Torrance, CA, USA) at 35°C ...
-
bioRxiv - Neuroscience 2021Quote: ... which was subsequently purified by preparative HPLC (Phenomenex Luna 5 μm C18(2) 100 A° 250 × 10m m ...
-
bioRxiv - Neuroscience 2021Quote: ... At the time of arrival analytical HPLC (Phenomenex Luna 5 μm C18(2) 100 A° 250 × 4.6mm ...
-
bioRxiv - Cancer Biology 2022Quote: ... Dried metabolites were resuspended in 50% ACN:water and 1/10th of the volume was loaded onto a Luna 3 um NH2 100A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on a Vanquish Flex (Thermo Scientific ...
-
bioRxiv - Immunology 2022Quote: ... Dried metabolites were resuspended in 50% ACN:water and 1/10th of the volume was loaded onto a Luna 3 um NH2 100A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on a Vanquish Flex (Thermo Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... Dried metabolites were resuspended in 50% ACN:water and 1/10th of the volume was loaded onto a Luna 3 um NH2 100A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on a Vanquish Flex (Thermo Scientific ...
-
bioRxiv - Immunology 2023Quote: ... Dried metabolites were resuspended in 50% ACN:water and 1/10th of the volume was loaded onto a Luna 3 um NH2 100A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on a Vanquish Flex (Thermo Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μm Fusion-RP 80 A (150 x 2 mm; Phenomenex # 00F-4424-B0) by the methods described below ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μm Fusion-RP 80 A (150 x 2 mm; Phenomenex # 00F-4424-B0) Pump B ...
-
bioRxiv - Microbiology 2022Quote: ... 1 mL of bacterium suspension was transferred into 2 mL glass vials (AR0-37K0-13, Phenomenex) and sealed with designated caps (AR0-5760-13 ...
-
bioRxiv - Neuroscience 2022Quote: ... 7 μL samples were injected onto a Gemini C18 column (150×4.60 mm, 110 Å, 5 μm particle size; Phenomenex, Torrance, CA, USA) connected to an electrochemical detector (Antec Leyden Intro ...
-
bioRxiv - Systems Biology 2019Quote: ... Two microliters of each sample was injected onto a Synergi Polar RP phenyl ether column (100 mm × 2.1 mm, 2.5 µm; Phenomenex, Macclesfield, Cheshire, UK). The analytical gradient started at 30 % B ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... The LC-MS-MS method used a Kinetex 2.6 μm Phenyl-Hexyl 100Å LC Column (50 x 4.6 mm; Phenomenex, Inc., Torrance, CA) heated to 35°C ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... to 2/98% over 2:50 min:sec on a Luna™ 5 µm C18 50x2.0 mm 100 A column (Phenomenex, Aschaffenburg, Germany). For MS/MS analyses in the positive electrospray ionisation mode on a Varian 1200 TSQ (Agilent Technologies ...
-
bioRxiv - Genetics 2021Quote: ... equipped with a Gemini C18 (3 mm, 100 mm x 2 mm) analytical column (Phenomenex, USA). An isocratic elution was applied with 80% acetonitrile-20% water and flow rate was set at 200 µL/min ...
-
bioRxiv - Plant Biology 2021Quote: ... using a reverse-phase column (Synergi 4 mm Hydro-RP 80A, 150 × 2 mm; Phenomenex). A linear gradient of methanol (A) ...
-
bioRxiv - Molecular Biology 2023Quote: ... chromatographic separation was performed on a Luna® NH2 column (100 mm × 2 mm, 3 μm; Phenomenex) maintained at 35°C using mobile phase A [2 mM ammonium acetate in dichloromethane/acetonitrile 7:93 (v/v)] and mobile phase B [2 mM ammonium acetate in water-acetonitrile 50:50 (v/v)] in the following gradient ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Metabolites were separated with a Luna NH2 column (100 mm × 2 mm, 3 μm particle size, Phenomenex). The column was maintained at 15℃ with a solvent flow rate of 0.3 mL min−1 ...
-
bioRxiv - Bioengineering 2020Quote: ... Samples were analyzed by isocratic elution using a 5 mM H2SO4 mobile phase at a constant flow rate of 0.5 mL min−1 on a REZEX ROA-organic acid H+ (8%) LC column (300 mm × 7.8 mm, Phenomenex). The column temperature was maintained at 55 °C and the refractive index detector was operated at 35 °C ...
-
bioRxiv - Biochemistry 2020Quote: ... The samples were separated via a C18 column (250 x 1 mm, 5 μm, 300 Å, Jupiter C18, Phenomenex) with a linear 10-min gradient from 2 % to 40 % solvent B ...