Labshake search
Citations for Phenomenex :
301 - 350 of 490 citations for 7 CHLORO 3 PHENYL PYRAZOLO 1 5 A PYRIMIDINE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2023Quote: ... Separation was carried out using a Gemini 5 μm NX-C18 110 Å column (2 × 100 mm; Phenomenex) with a mixture of 0.1% formic acid in water (A ...
-
bioRxiv - Cell Biology 2023Quote: ... Gas chromatograph was equipped with a 30 m (I.D. 250 μm, film 0.25 μm) ZB-35MS capillary column with 5 m guard column (Phenomenex). Helium was used as carrier gas with a constant flow rate of 1.2 ml/min ...
-
bioRxiv - Systems Biology 2024Quote: ... Peptide and probe-peptide adduct were separated on Gemini C18 column (Phenomenex, 5 µm, 50 x 4.6 mm) at a flow rate of 1 mL/min ...
-
bioRxiv - Microbiology 2024Quote: ... sub-fraction 5 (15 mg) was then subjected to reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Immunology 2019Quote: ... Samples were treated with 20 mM ammonium formate prior to injection onto a Phenomenex column (150×2.0 mm Gemini®NX-C18 3 µm 110Å; Phenomenex, Torrance, CA, USA) in an Agilent 1200 series HPLC (Agilent Biotechnologies ...
-
bioRxiv - Systems Biology 2020Quote: ... samples were four-fold diluted with 1% TFA in isopropanol and loaded onto SDB-RPS cartridges (Strata™-X-C, 30 mg/ 3 ml or Strata™-X-C, 200 mg/ 6 ml, Phenomenex Inc.). Before peptide loading ...
-
bioRxiv - Systems Biology 2021Quote: ... and glycolysis cycle metabolites were identified by using 5 mM ammonium acetate in water pH 9.9 as buffer A and 100% acetonitrile as buffer B using a Luna 3 μM NH2 100 Å chromatography column (Phenomenex, Torrance, CA). The gradient used ...
-
bioRxiv - Cell Biology 2022Quote: LC–MS analysis was performed on an Agilent 6230 electrospray ionization–time-of-flight MS coupled to an Agilent 1260 HPLC equipped with a Luna 3 μm Silica LC Column (Phenomenex; 50 × 2 mm) using a binary gradient elution system where solvent A was chloroform/methanol/ammonium hydroxide (85:15:0.5 ...
-
bioRxiv - Neuroscience 2023Quote: Pooled peptides from all samples were fractionated on a Basic Reverse Phase column (Gemini C18, 3um particle size, 110A pore, 3 mm internal diameter, 250 mm length, Phenomenex #00G-4439-Y0) on a Dionex Ultimate 3000 Off-line LC system ...
-
bioRxiv - Molecular Biology 2023Quote: ... Oxidised samples were treated by solid phase extraction on Strata™-X 33 μm Polymeric Reversed Phase cartridges 30 mg/3 mL (Phenomenex, Torrance, USA). HPLC analysis was performed using a Waters ACQUITY® UPLC® equipped with a Waters ACQUITY 2996 PDA detector ...
-
bioRxiv - Cancer Biology 2021Quote: ... normal-phase chromatography was performed with a Luna 5 μm NH2 100 Å LC column (Phenomenex 00B-4378-E0). Mobile phases were as follows ...
-
bioRxiv - Molecular Biology 2021Quote: ... and then packing with 2.3- to 2.5-cm-long reversed-phase 5 μm Aqua C18 resin (125 Å, Phenomenex), 2.3- to 2.5-cm 5 μm strong cation exchange resin (100 Å ...
-
bioRxiv - Plant Biology 2020Quote: ... equipped with a photodiode array detector and separated using a Gemini C-18 column (150 × 2.00 mm, 5 μm; Phenomenex) with a flow rate of 0.5 mL per minute and the following solvents and binary gradient ...
-
bioRxiv - Cancer Biology 2021Quote: Resuspended metabolites were separated by hydrophilic interaction chromatography with a Gemini reverse-phase C18 column (50 mm × 4.6 mm with 5 μm diameter particles) from Phenomenex together with precolumn (C18 ...
-
bioRxiv - Biophysics 2021Quote: ... The sample was fractionated using semipreparative Jupiter 5 μm-10 x 250 mm C18 reverse-phase HPLC column (Phenomenex) using a gradient elution of 60%–80% acetonitrile containing 0.1% TFA ...
-
bioRxiv - Neuroscience 2020Quote: ... capillary with a kasil frit which had been packed with 2.5 cm of 5-μm Partisphere strong cation exchanger (Whatman) followed by 2.5 cm of 10-μm Jupiter C18-A material (Phenomenex) After loading ...
-
bioRxiv - Microbiology 2021Quote: ... Samples were desalted on a 4 cm reversed-phase trapping column (in-house packed, 150 μm i.d. 5 μm Jupiter C18 particle from Phenomenex) at 5 μL/min for 10 min ...
-
bioRxiv - Plant Biology 2021Quote: ... Fractions 9–18 were combined (3.17 mg) and purified by HPLC on an ODS column (Kinetex C18, 4.6×250 mm, 5 μm; Phenomenex, USA) with a MeCN/H2O gradient system (30:70 to 100:00 over 40 min ...
-
bioRxiv - Systems Biology 2021Quote: ... The trapping column (100 µm ID) was packed with 10 cm of 5 µm Kinetex C18 RP resin (Phenomenex) while the nanospray emitter (75 µm ID ...
-
bioRxiv - Cell Biology 2021Quote: ... coupled to a strong cation exchange (SCX) separation column (Luna SCX 5 μm – 100 Å particles, 50 × 2mm, Phenomenex), resulting in 25 fractions.
-
bioRxiv - Cell Biology 2020Quote: ... equipped with a Luna 5 μm 100 angstrom 150 x 2.1 mm strong cation exchange (SCX) column (Catalog no 00F-4398-B0, Phenomenex). Buffer A was 5 mM KH2PO4 in 30% acetonitrile (Catalog no 34998 ...
-
bioRxiv - Biochemistry 2022Quote: ... SeGlcNAc-mBBr was purified by semi-preparative HPLC using a Luna C18 column (Phenomenex, 250 × 10 mm, 5 µm) with a flow rate of 2.5 mL/min and elution consisting of a gradient of 10–50% solvent B for 10 min ...
-
bioRxiv - Biochemistry 2022Quote: ... Neutral lipids were quantified by HPLC equipped with an ELSD (Evaporative Light Scattering Detector) using a cyanopropyl column (Luna 5 μm CN 100Å 250 x 4.6 mm; Phenomenex) with hexane as mobile phase A and methyl tertiary-butyl ether (MTBE):isopropanol (95:5 v/v ...
-
bioRxiv - Bioengineering 2020Quote: ... The resulting products were purified using a C4 Jupiter column (250 × 30 mm ID, 5 µm, Phenomenex, Torrance, CA) as described above ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Imtakt Corporation) for EPI-589 and Kinetex XB-C18 100A column (5 μm, 50 mm × 2.1 mm i.d., Phenomenex Inc.) for edaravone ...
-
bioRxiv - Synthetic Biology 2019Quote: Reduced and alkylated tryptic peptides (5 μL) were chromatographically separated on a Kinetex C18 column (2.1 mm x 100 mm, Phenomenex) using a linear gradient of 5–45% acetonitrile (in 0.1% formic acid ...
-
bioRxiv - Cell Biology 2019Quote: ... capillary with a 5 μm pulled tip packed with 15 cm 4 μm Jupiter C18 material (Phenomenex, Ventura, CA) was attached to the loading column with a union ...
-
bioRxiv - Genomics 2019Quote: ... The gradient program for the Shiseido column (Capcell Pak C18 UG120 4.6 × 250 mm, inner diameter = 5 µm, Phenomenex) was 82.5% solvent A ...
-
bioRxiv - Biochemistry 2020Quote: ... were loaded onto a triphasic column filled sequentially with 1.5 or 2.5 cm layers of 5 µm 100 Å C18 resin (Phenomenex), Luna 5 µm 100 Å strong cation exchange resin (Phenomenex ...
-
bioRxiv - Microbiology 2022Quote: ... equipped with a fused silica capillary column ZB–5 (30 m × 0.25 mm × 0.25 μm with 10 m guard column, Zebron, Phenomenex, USA). Helium at 1 ml · min-1 served as carrier gas with an injector temperature of 320 °C running in splitless mode ...
-
bioRxiv - Biochemistry 2023Quote: ... the peptides were eluted onto an analytical column (Jupiter C18, 0.5 × 50 mm, 5 μm, 300 Å, Phenomenex, CA) and separated by a 29 min linear gradient elution starting with 10% buffer B (80% acetonitrile in 0.08% formic acid ...
-
bioRxiv - Biochemistry 2023Quote: ... SpaB containing the reactive lysine is ligated to a FELPLTGGSG peptide (LPLTG peptide) by CdSrtAΔ and reactions are HPLC-quantified using a C4 column (5 µm, 4.6 × 150 mm; Phenomenex). Reactions were performed in 100 μL volumes and contained 25 µM of CdSrtAΔ ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Final purification was performed via analytical RP-HPLC using a C18 column (250 × 4.6 mm; 5 μm particle size; Phenomenex) at a flow rate of 1 mL/min using the same gradient ...
-
bioRxiv - Biochemistry 2023Quote: Quantification of energy metabolites and cofactors was performed using a cyano-phase LUNA column (50mm x 4.6mm, 5 µm; Phenomenex) with a 5.5 min run in negative ion mode with two separated runs ...
-
bioRxiv - Physiology 2023Quote: ... Separation of metabolites was conducted using a Luna 5 μm C5 100 Å LC column (Phenomenex 00B-4043-E0) with reverse phase chromatography ...
-
bioRxiv - Microbiology 2023Quote: ... then resolubilized in 3:1 acetonitrile to water and injected on a C18 analytical column (250x 4.6 mm, 5 µm, 100 Angstrom, Luna, Phenomenex) and separated on an Alliance HPLC (Waters ...
-
bioRxiv - Physiology 2023Quote: ... Separation of metabolites was conducted using a Luna 5 μm NH2 100 Å LC column (Phenomenex 00B-4378-E0) with normal phase chromatography ...
-
bioRxiv - Neuroscience 2024Quote: ... pentose phosphate pathway and Krebs cycle intermediates) was performed using a cyano–phase LUNA column (50 mm x 4.6mm, 5 µm; Phenomenex) by a 5 min run in negative ion mode ...
-
bioRxiv - Neuroscience 2024Quote: ... Negative ion mode analysis was conducted with a cyano–phase LUNA column (50 mm X 4.6 mm, 5 μm; Phenomenex) and 5 mM ammonium acetate pH 7 in MetOH as isocratic mobile phase in 5 min total run for each sample ...
-
bioRxiv - Biochemistry 2023Quote: ... and second by loading onto a C18 semi-preparative reverse phase column (Jupiter 5 μm C18 300 Å, Phenomenex) and eluting with a 5 - 70% acetonitrile gradient.
-
bioRxiv - Biochemistry 2023Quote: ... and second by loading onto a C18 semi-preparative reverse phase column (Jupiter 5 μm C18 300 Å; Phenomenex) and eluting with a 5 - 70% acetonitrile gradient.
-
bioRxiv - Cell Biology 2019Quote: ... acidified with formic acid (final concentration 3%) and cleaned by reversed phase solid phase extraction (STRATA-X from Phenomenex, P/N 8B-S100-TAK) following the manufacturer’s instructions ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... The autosampler was set to a 1 µL injection volume and after injection the samples were separated on an analytical capillary column (150 mm x 75 µm) packed in-house with Aqua C18 particles (3 µm particle size, 200 Å pores; Phenomenex, Utrecht, The Netherlands). The mobile phase was comprised of eluent A (98% water ...
-
bioRxiv - Developmental Biology 2020Quote: ... and then connected to a 100 μm fused silica microcapillary column packed with 5-μm C18 reverse-phase (Aqua, Phenomenex) (Florens and Washburn ...
-
bioRxiv - Cell Biology 2021Quote: ... self-packed with C-18 reverse-phase resin (Jupiter 5 um particles, 300 Å pore size; Phenomenex, Torrance, CA, USA) using a high- pressure packing cell on the Easy-nLC II system (Proxeon Biosystems ...
-
bioRxiv - Plant Biology 2021Quote: ... The appearance of the product pABAGlu was measured using Orbitrap-Exactive LC-MS in a reversed-phase Luna C18 column (5 μm particle size, 250 mm x 4.60 mm ID) (Phenomenex, USA) using gradient elution program ...
-
bioRxiv - Biochemistry 2020Quote: ... on a Agilent Technologies (GC-6890N, MS detector-5973) with a ZB-5 column (30 M x 25 mm x 25 mm, Phenomenex), with a temperature program of at 70 °C for 10 min followed by a gradient to 220°C at 5°C /min and held at 220°C for a further 15 min ...
-
bioRxiv - Microbiology 2020Quote: ... For HPLC-MS analysis 7 μl of the sample supernatant was injected into a Gemini C18 column (150 by 4.6 mm, 5 μm, 110 Å, Phenomenex). A 45 min program at a flow rate of 0.2 ml/min was used to separate the compounds as previously described (55) ...
-
bioRxiv - Cell Biology 2020Quote: ... Peptide mixtures were loaded onto 100 µm fused silica microcapillary columns packed with 5-μm C18 reverse phase (Aqua, Phenomenex), strong cation exchange particles (Partisphere SCX ...
-
bioRxiv - Biochemistry 2020Quote: ... samples containing 100 ng recombinant protein were run over a 5 μm Jupiter C4 300Å LC column (Phenomenex, Torrance, California) using the 1260 Infinity LC system (Agilent Technologies ...