Labshake search
Citations for Phenomenex :
51 - 100 of 644 citations for 6 methyl 4 oxo N phenyl 2 3 dihydro 1 4 oxathiine 5 carboxamide since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 150 × 2 mm; Phenomenex, Torrence, CA), guard column (BDS-Hypersil-C18 ...
-
bioRxiv - Biochemistry 2021Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Biochemistry 2020Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Plant Biology 2021Quote: ... Secondary metabolites were separated on an Aqua 3 µm C18 column (150 x 2 mm, 3 µm particle size) equipped with a pre-column filter from Phenomenex. The mobile phase consisted of 1 mM aqueous ammonium acetate (A) ...
-
bioRxiv - Developmental Biology 2024Quote: ... metabolites were separated using a Phenomenex Gemini C6-Phenyl (3µm, 100 x 2mm) column (Phenomenex, Torrance, CA, USA) via a gradient method consisting of mobile phase A ...
-
bioRxiv - Neuroscience 2023Quote: ... LC Column (150 × 2 mm, 3 μm particle size; Phenomenex, 00F-4377-B0). Chromatographic separation was achieved using the following conditions ...
-
bioRxiv - Molecular Biology 2020Quote: ... Three µl of each sample was loaded onto a 30 cm fused silica 75 µm column and 3.5 cm 150 µm fused silica KASIL 1 frit trap (PQ Corporation, Malvern, PA, USA) loaded with 4 µm Jupiter C12 Proteo reverse-phase resin (Phenomenex, Torrance, CA, USA) and analyzed with Thermo Fisher Scientific EASY-nLC ...
-
bioRxiv - Bioengineering 2021Quote: ... The column used was a Synergi 4 μm Fusion-RP 80Å C18 column (Phenomenex). Two solvents were used ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... a Synergi Max-RP column (150 x 4.6 mm, 4 μM, Phenomenex, Torrance, CA) was used ...
-
bioRxiv - Biochemistry 2022Quote: ... Analytes were separated on a Synergi Fusion-RP column (Phenomenex, 100 × 4.6 mm, 4 µm) with a flow rate of 0.5 mL/min and an elution program consisting of 0% solvent B wash for 5 min ...
-
bioRxiv - Microbiology 2023Quote: ... using a SecurityGuard Cartridges Carbo-H (4 × 3.0 mm; Phenomenex Inc., Torrance, CA, United States) connected to a Rezex ROA-Organic Acid H+ (300 × 7.8 mm ...
-
bioRxiv - Cell Biology 2023Quote: ... using a SecurityGuard Cartridges Carbo-H (4 x 3.0 mm) (Phenomenex Inc., Torrance CA, USA) connected to a Rezex ROA-Organic Acid H+ column (300 x 7.8 mm ...
-
bioRxiv - Immunology 2021Quote: ... column Gemini 3 µM C18 HPLC column (150 × 2 mm ID, Phenomenex, Torrance, CA, USA) at 35°C ...
-
bioRxiv - Neuroscience 2021Quote: ... which was subsequently purified by preparative HPLC (Phenomenex Luna 5 μm C18(2) 100 A° 250 × 10m m ...
-
bioRxiv - Neuroscience 2021Quote: ... At the time of arrival analytical HPLC (Phenomenex Luna 5 μm C18(2) 100 A° 250 × 4.6mm ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... fitted with a SecurityGuard Cartridges AQ C18 4 × 3.00 mm ID (Phenomenex, Part No: AJO-7511) in a SecuirtyGuard Cartridge Holder (Phenomenex ...
-
bioRxiv - Immunology 2021Quote: ... Separation was performed using the Synergi 4 μm Hydro-RP 80A Column (Phenomenex, Torrance, CA, USA) and an isocratic elution by the solvent composed of 75% acetonitrile and 25% 50 mM ammonium acetate (pH 7 ...
-
bioRxiv - Biochemistry 2024Quote: ... Analytes were separated on a Synergi Fusion-RP column (Phenomenex, 100 x 4.6 mm, 4 µm) with a flow rate of 0.5 mL/min and an elution program consisting of 5% solvent B for 3 min ...
-
bioRxiv - Systems Biology 2019Quote: ... Two microliters of each sample was injected onto a Synergi Polar RP phenyl ether column (100 mm × 2.1 mm, 2.5 µm; Phenomenex, Macclesfield, Cheshire, UK). The analytical gradient started at 30 % B ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... The LC-MS-MS method used a Kinetex 2.6 μm Phenyl-Hexyl 100Å LC Column (50 x 4.6 mm; Phenomenex, Inc., Torrance, CA) heated to 35°C ...
-
bioRxiv - Cell Biology 2019Quote: ... acidified with formic acid (final concentration 3%) and cleaned by reversed phase solid phase extraction (STRATA-X from Phenomenex, P/N 8B-S100-TAK) following the manufacturer’s instructions ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... to 2/98% over 2:50 min:sec on a Luna™ 5 µm C18 50x2.0 mm 100 A column (Phenomenex, Aschaffenburg, Germany). For MS/MS analyses in the positive electrospray ionisation mode on a Varian 1200 TSQ (Agilent Technologies ...
-
bioRxiv - Genetics 2021Quote: ... equipped with a Gemini C18 (3 mm, 100 mm x 2 mm) analytical column (Phenomenex, USA). An isocratic elution was applied with 80% acetonitrile-20% water and flow rate was set at 200 µL/min ...
-
bioRxiv - Systems Biology 2023Quote: ... The trapping column (100 µm ID) was packed with 6 cm of 5 µm Kinetex C18 reversed phase (RP) resin (Phenomenex), while the nanospray emitter (75 µm ID ...
-
bioRxiv - Biochemistry 2022Quote: ... and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 × 4.6 mm, 4 µm) with a flow rate of 1 mL/min and an elution program gradient consisting of a 0% solvent B wash for 3 min ...
-
bioRxiv - Biochemistry 2022Quote: ... extracted metabolites were separated using a Synergi 4-μm Fusion-RP 80 Å (150*4.6 mm, Phenomenex) LC column on Shimadzu Nexera UHPLC system ...
-
bioRxiv - Systems Biology 2020Quote: ... samples were four-fold diluted with 1% TFA in isopropanol and loaded onto SDB-RPS cartridges (Strata™-X-C, 30 mg/ 3 ml or Strata™-X-C, 200 mg/ 6 ml, Phenomenex Inc.). Before peptide loading ...
-
bioRxiv - Molecular Biology 2023Quote: ... chromatographic separation was performed on a Luna® NH2 column (100 mm × 2 mm, 3 μm; Phenomenex) maintained at 35°C using mobile phase A [2 mM ammonium acetate in dichloromethane/acetonitrile 7:93 (v/v)] and mobile phase B [2 mM ammonium acetate in water-acetonitrile 50:50 (v/v)] in the following gradient ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Metabolites were separated with a Luna NH2 column (100 mm × 2 mm, 3 μm particle size, Phenomenex). The column was maintained at 15℃ with a solvent flow rate of 0.3 mL min−1 ...
-
bioRxiv - Genetics 2019Quote: ... Chromatographic separation was achieved through a reverse phase Luna 5 μM PFP(2) column (Phenomenex) with a mobile phase comprised of 90% solvent A (95:5 mixture of methanol:isopropanol containing 2.5 mM ammonium formate ...
-
bioRxiv - Biochemistry 2021Quote: ... using reverse-phase C18(2) column (Luna 5 micron 250 mm x 4.6 mm, Phenomenex) and eluted with a linear gradient of 25–40% acetonitrile (0.085% trifluoroacetic acid) ...
-
bioRxiv - Plant Biology 2022Quote: ... and a Luna C18(2) trap column (5 μm; 100 Å; 20×0.5 mm; Phenomenex) with a column temperature of 55 °C ...
-
bioRxiv - Cancer Biology 2021Quote: ... The LC separations were achieved using a LUNA C18 column (4 µm, 50 x 2.1 mm) from Phenomenex, Inc ...
-
bioRxiv - Molecular Biology 2022Quote: ... a C18 reverse HPLC column (SynergiTM 4 µM particle size, 80 Å pore size, 250 × 2.0 mm; Phenomenex) was used ...
-
bioRxiv - Cancer Biology 2023Quote: ... at 4 °C) was used for SRM–LC-MS/MS using a normal-phase Luna NH2 column (Phenomenex). Mobile phases were buffer A (composed of 100% acetonitrile ...
-
bioRxiv - Molecular Biology 2023Quote: ... an Atlantis T3 column, 2.1 × 100 mm (Waters Corp., Milford, USA) with a SecurityGuard C18 guard column (4 × 2.0 mm2; Phenomenex), connected to a QTRAP 6500 (Sciex ...
-
bioRxiv - Molecular Biology 2023Quote: ... A C18 reverse HPLC column (SynergiTM 4 µM particle size, 80 Å pore size, 250 × 2.0 mm; Phenomenex) was used at a temperature of 35°C and a constant flow rate of 0.5 mL/min was applied ...
-
bioRxiv - Cancer Biology 2019Quote: ... Dried metabolites were resuspended in 50% ACN and 5 µl loaded onto a Luna 3 μm NH2 100 A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on an UltiMate 3000 RSLC (Thermo Scientific ...
-
bioRxiv - Plant Biology 2021Quote: ... Separation of metabolites was performed using a Luna C18 column (Phenomenex; 150 × 2 mm, 3 μm particle size). The mobile phase consisted of 97:3 water:methanol with 10 mM tributylamine and 15 mM acetic acid (solvent A ...
-
bioRxiv - Microbiology 2019Quote: ... A 70 μm × 150 mm Luna C18(2) reverse phase column (3 μm; 100-Å pore size; Phenomenex) was packed in-house ...
-
bioRxiv - Physiology 2020Quote: Samples were injected (10 μL) onto a Kinetex C18 column (150 × 3 mm; 2 μm, Phenomenex, Macclesfield, UK) at 40°C using a flow rate of 0.5 mL/min ...
-
bioRxiv - Microbiology 2022Quote: ... The column was a Gemini C18 (50 mm × 2 mm, 100 Å, particle size of 3-μm; Phenomenex). The mobile phases consisted of water (A ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Compounds were separated and eluted on a Synergi 4 µm Polar-RP 2.0 × 150 mm column (Phenomenex, Torrance, CA) at a flow rate of 0.6 mL/min and using a multi-stage gradient with mobile phases containing either 1 or 99% CH3CN in 0.2% formic acid.
-
bioRxiv - Molecular Biology 2021Quote: Peptides were loaded onto a 100-μm fused silica (Polymicro Technologies) capillary column packed with 3 cm of 5-μm reverse-phase C18 resin (Aqua; Phenomenex), 4 cm of 5-μm strong cation exchange resin (Luna ...
-
bioRxiv - Microbiology 2023Quote: ... digested samples were loaded onto a fused silica capillary column with a 5-μm electrospray tip and packed in house with 18 cm of Luna C18 3 μM particles (Phenomenex). The column was then placed in line with a Q-exactive mass spectrometer (ThermoFisher ...
-
bioRxiv - Microbiology 2023Quote: ... PF360-75-15-N-5, New Objective, 360 µm OD, 75 µm ID, 15 µm Tip PicoFrit Emitter; resin: 04A-4506, Phenomenex Aeris Peptide, C18 1.7 µm) via trapping column (column ...
-
bioRxiv - Biochemistry 2023Quote: ... The Fmoc-MAPA labelled N-glycans were fractionated by a semi-preparative normal phase HPLC (Luna, Phenomenex, LC Column, 250 × 10 mm, 5 µm, 100 Å) on a Shimadzu HPLC CBM-20A system ...
-
Systemic impact of the expression of the mitochondrial alternative oxidase on Drosophila developmentbioRxiv - Biochemistry 2022Quote: ... 10% of each sample was loaded onto a Luna NH2 (3 µm 100A, 150 mm x 2 mm, Phenomenex) column ...
-
bioRxiv - Microbiology 2021Quote: ... Five µl extracted samples were injected on the C18 column (Gemini, 3 µm, 2 x 150 mm, Phenomenex, CA) with the flow rate of 0.3 ml/min at 45°C ...
-
bioRxiv - Cell Biology 2021Quote: ... Analytes were separated on a Luna C18 column (30 × 2 mm, 3 μm, 100 Å; Phenomenex, Torrance, CA, USA). The mobile phase consisted of 2 mM ammonium acetate in 100% methanol ...