Citations for Phenomenex :
151 - 200 of 370 citations for 6 Methoxy 2 2 4 4 Tetrabde Ring 13C12 99% 50 Ug Ml In Nonane since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Diclofenac concentrations in the samples were measured using a Synergi Max-RP column (150 x 4.6 mm, 4 µM, Phenomenex, Torrance, CA) coupled to an Agilent 1200 Series High-Performance Liquid Chromatography (HPLC)-UV system (Santa Clara ...
-
bioRxiv - Microbiology 2019Quote: ... Pigments were separated on a heated (40°C) Luna 3μC8(2) 100 Å column (Phenomenex Inc., USA) with binary solvent system A ...
-
bioRxiv - Biochemistry 2020Quote: ... peptides were separated on a reverse phase (RP) column (Phenomenex Onyx Monolithic C18 column, 100 × 2 mm) at 1 °C using a flow rate of 500 μL/min under the following conditions ...
-
bioRxiv - Physiology 2022Quote: ... Triglyceride species were separated chromatographically on a C5 column (Luna, 100 x 2 mm, 5 μm, Phenomenex). Mobile phase A was composed of 95:5 ratio of water:methanol ...
-
bioRxiv - Molecular Biology 2023Quote: ... chromatographic separation was performed on a Luna® NH2 column (100 mm × 2 mm, 3 μm; Phenomenex) maintained at 35°C using mobile phase A [2 mM ammonium acetate in dichloromethane/acetonitrile 7:93 (v/v)] and mobile phase B [2 mM ammonium acetate in water-acetonitrile 50:50 (v/v)] in the following gradient ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Metabolites were separated with a Luna NH2 column (100 mm × 2 mm, 3 μm particle size, Phenomenex). The column was maintained at 15℃ with a solvent flow rate of 0.3 mL min−1 ...
-
bioRxiv - Microbiology 2024Quote: ... Sub-fraction 7 (25 mg) was subjected to reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Microbiology 2024Quote: ... Sub-fraction 8 (67 mg) was purified by reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Biochemistry 2019Quote: ... samples were injected and separated on a 250 × 3.0 mm Synergi™ 4u Max-RP 80A column (4 μm particle size, Phenomenex, CO, USA) with a flow rate of 350 μL min−1 ...
-
bioRxiv - Cancer Biology 2019Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex # 04A-4299) which was previously equilibrated on an Agilent 600 series HPLC using gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Biochemistry 2022Quote: ... The samples were then filtered and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 × 4.6 mm, 4 µm) with a flow rate of 1 mL/min and elution consisting of 5% solvent B for 3 min ...
-
bioRxiv - Biochemistry 2022Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which was previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Cell Biology 2022Quote: ... Purified peptides were pressure-loaded onto a 250 mm silica capillary tubing filled with 4 cm of Aqua C18 reverse-phase resin (Phenomenex # 04A-4299). The samples were then attached using a MicroTee PEEK 360 µm fitting (Thermo Fisher Scientific #p-888 ...
-
bioRxiv - Microbiology 2021Quote: We performed the LC-MS/MS analysis on a reversed phase C18 column (Phenomenex Synergi Fusion, 2.1 x 150 mm, 4 µm) coupled via heated electrospray ionization (ESI ...
-
bioRxiv - Neuroscience 2022Quote: ... chromatography was carried out on a Synergy Fusion RP \SI 80 Å column (150 x 2.0 mm id, 4 µm, Phenomenex, Aschaffenburg, Germany) using the following solvent gradient (0.2 mL/min ...
-
bioRxiv - Biochemistry 2023Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which had been previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Biochemistry 2023Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which was previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Plant Biology 2021Quote: ... Separation of metabolites was performed using a Luna C18 column (Phenomenex; 150 × 2 mm, 3 μm particle size). The mobile phase consisted of 97:3 water:methanol with 10 mM tributylamine and 15 mM acetic acid (solvent A ...
-
bioRxiv - Plant Biology 2020Quote: ... Phytohormones separation was carried out by injecting 2 μL into a Kinetex Evo C18 core-shell column (100 × 2.1mm, 2.6μm, Phenomenex, USA) at a flow rate of 0.7 mL/min ...
-
bioRxiv - Biophysics 2021Quote: ... using a Luna C8(2) AXIA Pack column (250 x 21.2 mm, 5 μm, 100 Å; Phenomenex, USA). A linear gradient of acetonitrile in 0.1% aqueous TFA was applied as a mobile phase ...
-
bioRxiv - Microbiology 2019Quote: ... A 70 μm × 150 mm Luna C18(2) reverse phase column (3 μm; 100-Å pore size; Phenomenex) was packed in-house ...
-
bioRxiv - Physiology 2020Quote: Samples were injected (10 μL) onto a Kinetex C18 column (150 × 3 mm; 2 μm, Phenomenex, Macclesfield, UK) at 40°C using a flow rate of 0.5 mL/min ...
-
bioRxiv - Microbiology 2020Quote: ... was fitted with a Luna C18(2) column (150 × 4.6 mm, 5 µm; Phenomenex, Lane Cove West, Australia). The mobile phases were 0.5 mM ammonium acetate in water (A ...
-
Dynamic states of eIF6 and SDS variants modulate interactions with uL14 of the 60S ribosomal subunitbioRxiv - Biochemistry 2022Quote: ... and peptides were separated on a reverse phase column (Phenomenex Onyx Monolithic C18 column, 100 x 2 mm) at 1 UC using a flow rate of 400 µl/min ...
-
bioRxiv - Plant Biology 2023Quote: ... Separation was carried out using a Gemini 5 μm NX-C18 110 Å column (2 × 100 mm; Phenomenex) with a mixture of 0.1% formic acid in water (A ...
-
bioRxiv - Microbiology 2024Quote: ... sub-fraction 5 (15 mg) was then subjected to reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Biochemistry 2024Quote: ... using a Zebron ZB-5HT Inferno GC column (30 m x 0.25 mm i.d., 0.25 mm film thickness) with a Z- guard column (2 m, 0.53 mm i.d.) (Phenomenex, CA, USA) coupled to an Agilent 5890A gas chromatography system with CTC CombiPAL autosampler ...
-
bioRxiv - Plant Biology 2019Quote: ... The lyophilized powder was resuspended in H2O containing 0.09% TFA (v/v) and applied to a 6-ml C18-T cartridge (Solid Phase Extraction Strata C18-T, Phenomenex, Torrance, CA, USA) previously equilibrated with solvent A (H2O ...
-
bioRxiv - Biochemistry 2022Quote: ... Reactions quenched with mBBr were filtered and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 × 4.6 mm, 4 µm) with a flow rate of 1 mL/min and an elution program consisting of a 5% solvent B wash for 3 min ...
-
bioRxiv - Molecular Biology 2020Quote: ... Three µl of each sample was loaded onto a 30 cm fused silica 75 µm column and 3.5 cm 150 µm fused silica KASIL 1 frit trap (PQ Corporation, Malvern, PA, USA) loaded with 4 µm Jupiter C12 Proteo reverse-phase resin (Phenomenex, Torrance, CA, USA) and analyzed with Thermo Fisher Scientific EASY-nLC ...
-
bioRxiv - Systems Biology 2024Quote: ... The LC separation system consisted of an in-house packed solid-phase extraction (SPE) column (100 µm i.d., 4 cm, packed with 5 µm, C18 packing material (300 Å pore size; Phenomenex, Torrance, CA, USA) and an in-house packed LC column (50 μm i.d. ...
-
bioRxiv - Biochemistry 2024Quote: ... The samples were then filtered and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 x 4.6 mm, 4 µm) with a flow rate of 1 mL/min ...
-
Systemic impact of the expression of the mitochondrial alternative oxidase on Drosophila developmentbioRxiv - Biochemistry 2022Quote: ... 10% of each sample was loaded onto a Luna NH2 (3 µm 100A, 150 mm x 2 mm, Phenomenex) column ...
-
bioRxiv - Systems Biology 2019Quote: ... Exactive chromatographic separation was achieved on a Synergy Hydro-RP column (100 mm×2 mm, 2.5 μm particle size, Phenomenex) with a flow rate of 200 μL/min ...
-
bioRxiv - Microbiology 2021Quote: ... Five µl extracted samples were injected on the C18 column (Gemini, 3 µm, 2 x 150 mm, Phenomenex, CA) with the flow rate of 0.3 ml/min at 45°C ...
-
bioRxiv - Cell Biology 2021Quote: ... Analytes were separated on a Luna C18 column (30 × 2 mm, 3 μm, 100 Å; Phenomenex, Torrance, CA, USA). The mobile phase consisted of 2 mM ammonium acetate in 100% methanol ...
-
bioRxiv - Cell Biology 2022Quote: ... two 1.0 mm Empore C18 filter plugs were added to a pipette tip and 2 mg 5μm C18 resin (Phenomenex) was added to the top of the C18 filter plug ...
-
bioRxiv - Biochemistry 2022Quote: ... and 5–10 μl of digests were injected into an Agilent 1290 uHPLC system bearing a Synergi Fusion-RP column (100 × 2 mm, 2.5 μm, Phenomenex) at 35 °C with a flow rate of 0.35 ml/min and a solvent system consisting of 5 mM NH4OAc (Buffer A ...
-
bioRxiv - Microbiology 2020Quote: Approximately 250 mL of concentrated crude yeast AI-2 mimic preparation was filtered through a 0.45 μm PVDF filter (MilliporeSigma) and separated on a 2 × 25-cm Luna C18 column (Phenomenex) using a mobile phase consisting of 5% water in methanol at a flow rate of 10 mL/min ...
-
bioRxiv - Immunology 2020Quote: ... Glycolytic and TCA intermediates were separated on a Luna Amino (NH2) column (3 µm, 100A 2 × 150 mm, Phenomenex), that was maintained in a temperature-controlled chamber (37°C).
-
Surveying the landscape of tRNA modifications by combining tRNA sequencing and RNA mass spectrometrybioRxiv - Biochemistry 2019Quote: ... 18 μl aliquots were mixed with 2 μl of 50 μM 15N-dA and 2.5-10 μl of digests were injected into a Agilent 1290 uHPLC system bearing a Synergi Fusion-RP column (100 × 2 mm, 2.5 μm, Phenomenex) at 35 °C with a flow rate 0.35 ml/min with a solvent system consisting of 5 mM NH4OAc (Buffer A ...
-
bioRxiv - Biochemistry 2022Quote: ... dried lipids were re-dissolved in 40% UPLC solvent B (90% 2-propanol/10% acetonitrile/0.1% formic acid/10 mM NH4HCO3) and transferred to silanized glass inserts (Phenomenex) using Hamilton syringes ...
-
bioRxiv - Plant Biology 2020Quote: ... 2.1×50 mm column (Phenomenex). The chromatography solvent was 20% acetonitrile ...
-
bioRxiv - Plant Biology 2020Quote: ... 2.1×50 mm column (Phenomenex). The chromatography solvent was 20% acetonitrile ...
-
bioRxiv - Biochemistry 2023Quote: ... Samples were loaded into a precolumn (150 μM i.d., 4 cm length, packed in-lab with Jupiter C18 packing material, 300 Å pore size, 5 μM particle size: Phenomenex, Torrance, CA, USA) using mobile phase A (0.1% formic acid in water) ...
-
bioRxiv - Microbiology 2023Quote: ... Analysis with a sample volume of 40 µL was carried out using a Chromaster HPLC-System (Hitachi, Tokyo, Japan) equipped with a SecurityGuard Cartridge Carbo-H (4×3.0 mm; Phenomenex Inc., Torrance, CA, United States) and a Rezex ROA-Organic Acid H+ (300×7.8 mm ...
-
bioRxiv - Neuroscience 2021Quote: ... Samples were injected onto a Prodigy C18 column (100Å∼2 mm I.D., 3-µm particle size, Phenomenex, Torrance, CA, USA). In the tissue homogenates ...
-
bioRxiv - Plant Biology 2021Quote: ... Secondary metabolites were separated on an Aqua 3 µm C18 column (150 x 2 mm, 3 µm particle size) equipped with a pre-column filter from Phenomenex. The mobile phase consisted of 1 mM aqueous ammonium acetate (A) ...
-
bioRxiv - Systems Biology 2021Quote: ... Samples were then acidified to pH of ~2 by addition of 10% TFA and desalted using Strata SPE columns (Phenomenex). Desalted peptides were lyophilized to dryness in a SpeeVac (Thermo) ...
-
bioRxiv - Microbiology 2021Quote: ... The deuterated mixture was then digested online by using the same nepenthesin-2 column and the resultant peptides were desalted with flow through on a trap column (Phenomenex UHPLC fully Porous Polar C18 ...