Labshake search
Citations for Phenomenex :
101 - 150 of 283 citations for 6 BROMO 2 METHYL QUINOLINE 4 CARBOXYLIC ACID METHYL ESTER since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Systems Biology 2021Quote: ... and 4 x 3 mm ID Carbo-H guard (Phenomenex, Torrance, CA). The column was maintained at 50 °C and 1.5 mM H2SO4 was used as the mobile phase at a flow rate of 0.6 mL/min ...
-
bioRxiv - Molecular Biology 2020Quote: ... packed with 4 μm Hydro-RP 80 Å (Phenomenex cat # 04A-4375), as previously described (80) ...
-
bioRxiv - Microbiology 2023Quote: ... packed with 4 μm Hydro-RP 80 Å (Phenomenex cat # 04A-4375), as previously described 73 ...
-
bioRxiv - Microbiology 2019Quote: ... Luna-NH2 column (3 μm, 150 × 2 mm, Phenomenex) was used flowing at 0.4 mL/min ...
-
bioRxiv - Synthetic Biology 2024Quote: ... All vials (2 mL) and caps were from Phenomenex.
-
bioRxiv - Microbiology 2021Quote: ... The mixture was incubated for 6 h at a room temperature and separated using a Jupiter C18 HPLC column (Phenomenex) and acetonitrile gradient from 20 to 50% in 30 min in the presence of 0.1% trifluoroacetic acid ...
-
bioRxiv - Immunology 2022Quote: Trypsin-digested 6-Helix protein was then purified by high-pressure liquid chromatography (HPLC) on a C18 semi-preparative column (Phenomenex) over a 38-45% acetonitrile gradient in the presence of 0.1% trifluoroacetic acid ...
-
bioRxiv - Systems Biology 2023Quote: ... The trapping column (100 µm ID) was packed with 6 cm of 5 µm Kinetex C18 reversed phase (RP) resin (Phenomenex), while the nanospray emitter (75 µm ID ...
-
bioRxiv - Systems Biology 2020Quote: ... machine with a UV Diode Array Detector SPD-M30A NexeraX2 or/and a Refractive Index Detector RID 20A and an analytical ion-exclusion Rezex ROA-Organic Acid H+(8%) column (250×4.6 mm) with guard column (Phenomenex, Torrance, USA) (5 mM H2SO4 in MilliQ water (18.2 MΩ),isocratic ...
-
bioRxiv - Systems Biology 2020Quote: ... machine with a UV Diode Array Detector SPD-M30A NexeraX2 or/and a Refractive Index Detector RID 20A and an analytical ion-exclusion Rezex ROA-Organic Acid H+(8%) column (250×4.6 mm) with guard column (Phenomenex, Torrance, USA) (5 mM H2SO4 in MilliQ water (18.2 MΩ) ...
-
bioRxiv - Plant Biology 2023Quote: ... and separated through a 3-min isocratic elution (5% acetonitrile, 95% water, 0.1% formic acid) on a 1.7 μm C18 column (Kinetex XB-C18, Phenomenex, Torrance, CA, USA) at 250 μL/min and 25°C ...
-
bioRxiv - Biochemistry 2020Quote: ... 100 x 2 mm column (Phenomenex®, Torrance, California, USA) at 35 °C and a flow rate of 0.35 mL/min was used in combination with a binary mobile phase of 5 mM NH4OAc aqueous buffer A ...
-
bioRxiv - Biochemistry 2020Quote: ... 100 x 2 mm column (Phenomenex®, Torrance, California, USA). Mobile phase A was 10 mM ammonium formate and mobile phase B was 80% acetonitrile containing 2 mM ammonium formate ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 2.5 μm Luna C18(2) HST column (Phenomenex, Torrance, CA) connected to an LC-20ADXR (Shimadzu ...
-
bioRxiv - Plant Biology 2019Quote: ... norvaline used as internal standard and reagents were supplied in the EZ:faast GC-MS kit for amino acid analysis (Phenomenex; Torrance, California, USA). A Perkin Elmer AutoSystemXL gas chromatograph was directly coupled to a Perkin Elmer TurboMass mass spectrometer (Perkin Elmer ...
-
bioRxiv - Bioengineering 2020Quote: ... a Rezex ROA-Organic Acid H+ (8%) Analysis HPLC Column (Cat #: #00H-0138-K0, Phenomenex, Inc., Torrance, CA, 300 x 7.8 mme;) was employed for the separation of xylose and xylitol ...
-
bioRxiv - Biochemistry 2021Quote: ... were carried out using an RSLC system (Dionex) equipped with a 100 × 7.8 mm Rezex RFQ-Fast Acid H+ (8%) (Phenomenex, Torrance, CA, USA) column operated at 85 °C ...
-
bioRxiv - Systems Biology 2021Quote: ... and metabolites subsequently quantified using the Dionex 2000 HPLC system (Dionex, Idstein, Germany) with a Rezex ROA-Organic Acid H + (8%, Phenomenex, Aschaffenburg, Germany) and a RI-101 detector (Shodex ...
-
bioRxiv - Microbiology 2020Quote: ... The HPLC system was equipped with a Refractive Index Detector (Alliance HPLC with 2414 RID, Waters, Eschborn, Germany) and a Rezex ROA-Organic Acid H+ (8%) column (Phenomenex, Aschaffenburg, Germany) which was held at 65 °C during all measurements ...
-
bioRxiv - Microbiology 2022Quote: ... The analytical separation was achieved with a Rezex ROA-Organic Acid H+ (8%) (150 × 7.8 mm) ion exclusion column (Phenomenex, Torrance, CA, USA) using an isocratic mobile phase of acidified water (pH 2.1 ...
-
bioRxiv - Bioengineering 2021Quote: ... The column used was a Synergi 4 μm Fusion-RP 80Å C18 column (Phenomenex). Two solvents were used ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... a Synergi Max-RP column (150 x 4.6 mm, 4 μM, Phenomenex, Torrance, CA) was used ...
-
bioRxiv - Microbiology 2019Quote: ... and the remaining 80 μL of each BALF sample was prepared for GC-MS analysis according to manufacturer instructions using the Phenomenex EZFaast Free Amino Acids Analysis GC-MS kit (Phenomenex, Torrance, CA, USA). Briefly ...
-
bioRxiv - Immunology 2019Quote: ... 150 mm x 2 mm reverse phase column (Phenomenex, Torrance, CA) maintained at 30°C using a solvent gradient method ...
-
bioRxiv - Neuroscience 2023Quote: ... The aminopropyl column (Luna 3 µm NH2, 2 × 100 mm, Phenomenex) was used for the chromatographic separation ...
-
bioRxiv - Biochemistry 2022Quote: ... Analytes were separated on a Synergi Fusion-RP column (Phenomenex, 100 × 4.6 mm, 4 µm) with a flow rate of 0.5 mL/min and an elution program consisting of 0% solvent B wash for 5 min ...
-
bioRxiv - Microbiology 2023Quote: ... using a SecurityGuard Cartridges Carbo-H (4 × 3.0 mm; Phenomenex Inc., Torrance, CA, United States) connected to a Rezex ROA-Organic Acid H+ (300 × 7.8 mm ...
-
bioRxiv - Cell Biology 2023Quote: ... using a SecurityGuard Cartridges Carbo-H (4 x 3.0 mm) (Phenomenex Inc., Torrance CA, USA) connected to a Rezex ROA-Organic Acid H+ column (300 x 7.8 mm ...
-
bioRxiv - Biochemistry 2024Quote: ... coupled to a Gemini guard column (Phenomenex, 4 x 3 mm, catalog no.: AJ0-7597). The flow rate for the LC method was 0.5 mL/min ...
-
bioRxiv - Cell Biology 2019Quote: ... acidified with formic acid (final concentration 3%) and cleaned by reversed phase solid phase extraction (STRATA-X from Phenomenex, P/N 8B-S100-TAK) following the manufacturer’s instructions ...
-
bioRxiv - Systems Biology 2020Quote: ... samples were four-fold diluted with 1% TFA in isopropanol and loaded onto SDB-RPS cartridges (Strata™-X-C, 30 mg/ 3 ml or Strata™-X-C, 200 mg/ 6 ml, Phenomenex Inc.). Before peptide loading ...
-
bioRxiv - Plant Biology 2019Quote: ... The lyophilized powder was resuspended in H2O containing 0.09% TFA (v/v) and applied to a 6-ml C18-T cartridge (Solid Phase Extraction Strata C18-T, Phenomenex, Torrance, CA, USA) previously equilibrated with solvent A (H2O ...
-
bioRxiv - Systems Biology 2020Quote: ... using an analytical Luna C18(2) reverse-phase column (Phenomenex, Torrance, CA), acetonitrile/H2O (with 0.05% v/v CF3CO2H ...
-
bioRxiv - Plant Biology 2023Quote: ... including a SecurityGuard™ C18 guard column (2.1 mm, 2 μm; Phenomenex). Mobile phases A and B consisted of ...
-
bioRxiv - Cell Biology 2023Quote: ... using an analytical Luna C18(2) reverse-phase column (Phenomenex, Torrance, CA), acetonitrile/H2O (with 0.05% v/v CF3CO2H ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... fitted with a SecurityGuard Cartridges AQ C18 4 × 3.00 mm ID (Phenomenex, Part No: AJO-7511) in a SecuirtyGuard Cartridge Holder (Phenomenex ...
-
bioRxiv - Immunology 2021Quote: ... Separation was performed using the Synergi 4 μm Hydro-RP 80A Column (Phenomenex, Torrance, CA, USA) and an isocratic elution by the solvent composed of 75% acetonitrile and 25% 50 mM ammonium acetate (pH 7 ...
-
bioRxiv - Biochemistry 2024Quote: ... Analytes were separated on a Synergi Fusion-RP column (Phenomenex, 100 x 4.6 mm, 4 µm) with a flow rate of 0.5 mL/min and an elution program consisting of 5% solvent B for 3 min ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... C-18 (2) with TMS end capping) were purchased from Phenomenex (Torrance, CA). Lutetium-177 in the form of lutetium chloride (177Lu-LuCl3 ...
-
bioRxiv - Systems Biology 2022Quote: ... Glass vials (2 mL) and caps used for soil incubations were from Phenomenex, and 3-oxo-C12-HSL was from Sigma-Aldrich ...
-
bioRxiv - Neuroscience 2021Quote: ... which was subsequently purified by preparative HPLC (Phenomenex Luna 5 μm C18(2) 100 A° 250 × 10m m ...
-
bioRxiv - Cell Biology 2020Quote: ... Analytes were separated on a C18(2) Luna column (2.1 × 100 mm, Phenomenex) at a flow rate of 0.63 mL/min using 50:50 H2O:ACN with 0.1% formic acid for solvent A and 40:60 ACN:IPA with 0.1% formic acid for solvent B ...
-
bioRxiv - Neuroscience 2021Quote: ... At the time of arrival analytical HPLC (Phenomenex Luna 5 μm C18(2) 100 A° 250 × 4.6mm ...
-
bioRxiv - Neuroscience 2023Quote: ... LC Column (150 × 2 mm, 3 μm particle size; Phenomenex, 00F-4377-B0). Chromatographic separation was achieved using the following conditions ...
-
bioRxiv - Biochemistry 2022Quote: ... and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 × 4.6 mm, 4 µm) with a flow rate of 1 mL/min and an elution program gradient consisting of a 0% solvent B wash for 3 min ...
-
bioRxiv - Biochemistry 2022Quote: ... extracted metabolites were separated using a Synergi 4-μm Fusion-RP 80 Å (150*4.6 mm, Phenomenex) LC column on Shimadzu Nexera UHPLC system ...
-
bioRxiv - Microbiology 2022Quote: ... mass spectrometer fitted with an Exion UHPLC system having a Kinetex 2.6 mm hydrophilic interaction liquid chromatography (HILIC) column (100 Å particle size, 150 mm length, and 3 mm internal diameter; Phenomenex, Intek Chromasol Pvt. Ltd., India). Nitrogen was used as the nebulizer gas ...
-
bioRxiv - Cancer Biology 2021Quote: ... The LC separations were achieved using a LUNA C18 column (4 µm, 50 x 2.1 mm) from Phenomenex, Inc ...
-
bioRxiv - Molecular Biology 2022Quote: ... a C18 reverse HPLC column (SynergiTM 4 µM particle size, 80 Å pore size, 250 × 2.0 mm; Phenomenex) was used ...
-
bioRxiv - Neuroscience 2020Quote: ... capillary with a 5-μm pulled tip packed with 15 cm of 4-μm Jupiter C18 material (Phenomenex) was attached to the loading column with a union ...