Labshake search
Citations for Phenomenex :
1 - 50 of 441 citations for 3 2 Bromobenzoyl amino thioxomethyl amino 4 chloro benzoic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2020Quote: ... Glycolytic and TCA intermediates were separated on a Luna Amino (NH2) column (3 µm, 100A 2 × 150 mm, Phenomenex), that was maintained in a temperature-controlled chamber (37°C).
-
bioRxiv - Physiology 2021Quote: ... all amino acids were quantified using a Water Acquity UPLC system coupled to a Synapt G2-Si mass spectrometer (Waters) in tandem mode (LC-MS/MS) using the EZ:faast amino acid sample testing kit (Phenomenex, 2003). Briefly ...
-
bioRxiv - Systems Biology 2023Quote: ... 4 3 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Cancer Biology 2023Quote: ... 4 x 2 mm (Phenomenex). The eluents were A ...
-
bioRxiv - Cell Biology 2024Quote: ... The compounds were separated on a Synergi Polar-RP column (150 × 2.0 mm, 4 µm, 80 Å) with a 4 × 2 mm C18 guard column (4 × 2 mm, Phenomenex). The mobile phase consisted of 0.1% (v/v ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... The compounds were separated on a Synergi Polar-RP column (150 × 2.0 mm, 4 µm, 80 Å) with a 4 × 2 mm C18 guard column (4 × 2 mm, Phenomenex). The mobile phase consisted of 0.1% (v/v ...
-
bioRxiv - Cancer Biology 2023Quote: ... A Luna C18(2) C8 column (3 μm, 2 mm × 50 mm, Phenomenex) was used ...
-
bioRxiv - Neuroscience 2024Quote: ... with Synergi Fusion-RP (4.6 3 150mm, 4 mm; Phenomenex) column ...
-
bioRxiv - Cell Biology 2024Quote: ... coupled to a C5 guard column (Phenomenex, 4 × 3 mm) was used for LC separation ...
-
bioRxiv - Systems Biology 2021Quote: ... and 4 x 3 mm ID Carbo-H guard (Phenomenex, Torrance, CA). The column was maintained at 50 °C and 1.5 mM H2SO4 was used as the mobile phase at a flow rate of 0.6 mL/min ...
-
bioRxiv - Molecular Biology 2024Quote: ... and 4 × 3 mm ID Carbo-H guard (Phenomenex, Torrance, CA, USA). The column was maintained at 50°C and 1.5 mM H2SO4 was used as the mobile phase at a flow rate of 0.6 mL/min ...
-
bioRxiv - Neuroscience 2023Quote: ... The aminopropyl column (Luna 3 µm NH2, 2 × 100 mm, Phenomenex) was used for the chromatographic separation ...
-
Identification of ABHD6 as a regulator of lysophosphatidylserines in the mammalian liver and kidneysbioRxiv - Biochemistry 2024Quote: ... coupled with a Gemini guard column (Phenomenex, 4×3 mm, Phenomenex security cartridge). The solvents used were buffer A ...
-
Identification of ABHD6 as a regulator of lysophosphatidylserines in the mammalian liver and kidneysbioRxiv - Biochemistry 2024Quote: ... coupled with a Gemini guard column (Phenomenex, 4×3 mm, Phenomenex security cartridge) was used for LC separation ...
-
Identification of ABHD6 as a regulator of lysophosphatidylserines in the mammalian liver and kidneysbioRxiv - Biochemistry 2024Quote: ... coupled with a Gemini guard column (Phenomenex, 4×3 mm, Phenomenex security cartridge) was used for LC separation ...
-
Identification of ABHD6 as a regulator of lysophosphatidylserines in the mammalian liver and kidneysbioRxiv - Biochemistry 2024Quote: ... coupled with a Gemini guard column (Phenomenex, 4×3 mm, Phenomenex security cartridge). The solvents used were buffer A ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 150 × 2 mm; Phenomenex, Torrence, CA), guard column (BDS-Hypersil-C18 ...
-
bioRxiv - Cancer Biology 2023Quote: ... using a Synergi HydroRP column (250 x 2; 4 µm, Phenomenex) and 0.1 % of formic acid in water and methanol as mobile phases ...
-
bioRxiv - Plant Biology 2021Quote: ... Secondary metabolites were separated on an Aqua 3 µm C18 column (150 x 2 mm, 3 µm particle size) equipped with a pre-column filter from Phenomenex. The mobile phase consisted of 1 mM aqueous ammonium acetate (A) ...
-
bioRxiv - Bioengineering 2023Quote: ... in combination with a Security Guard HPLC Guard Cartridge system Carbo-H 4 x (4 x 3 mm; Phenomenex, Torrance, California, USA) as pre-column was used at 80 °C ...
-
bioRxiv - Neuroscience 2023Quote: ... LC Column (150 × 2 mm, 3 μm particle size; Phenomenex, 00F-4377-B0). Chromatographic separation was achieved using the following conditions ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... and 0.1% v/v trifluoroacetic acid and running through a C8 column (Eclipse XDB-C8, 3 μm, 3.0×100 mm, Phenomenex) at a flow rate of 0.6 mL/minute ...
-
bioRxiv - Biochemistry 2024Quote: ... coupled to a Gemini guard column (Phenomenex, 4 x 3 mm, catalog no.: AJ0-7597). The flow rate for the LC method was 0.5 mL/min ...
-
bioRxiv - Cell Biology 2024Quote: ... Both substrates and metabolites were separated on a Synergi Polar-RP column (150 x 2.0 mm, 4 μm, 80 Å) with a 4 x 2 mm C18 guard column (Phenomenex). The mobile phase consisted of 0.1% (v/v ...
-
bioRxiv - Immunology 2021Quote: ... column Gemini 3 µM C18 HPLC column (150 × 2 mm ID, Phenomenex, Torrance, CA, USA) at 35°C ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μm Fusion-RP 80 A (150 x 2 mm; Phenomenex # 00F-4424-B0) by the methods described below ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μm Fusion-RP 80 A (150 x 2 mm; Phenomenex # 00F-4424-B0) Pump B ...
-
bioRxiv - Biochemistry 2022Quote: ... dried lipids were re-dissolved in 40% UPLC solvent B (90% 2-propanol/10% acetonitrile/0.1% formic acid/10 mM NH4HCO3) and transferred to silanized glass inserts (Phenomenex) using Hamilton syringes ...
-
bioRxiv - Genetics 2021Quote: ... equipped with a Gemini C18 (3 mm, 100 mm x 2 mm) analytical column (Phenomenex, USA). An isocratic elution was applied with 80% acetonitrile-20% water and flow rate was set at 200 µL/min ...
-
bioRxiv - Plant Biology 2021Quote: ... using a reverse-phase column (Synergi 4 mm Hydro-RP 80A, 150 × 2 mm; Phenomenex). A linear gradient of methanol (A) ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Metabolites were separated with a Luna NH2 column (100 mm × 2 mm, 3 μm particle size, Phenomenex). The column was maintained at 15℃ with a solvent flow rate of 0.3 mL min−1 ...
-
bioRxiv - Molecular Biology 2023Quote: ... chromatographic separation was performed on a Luna® NH2 column (100 mm × 2 mm, 3 μm; Phenomenex) maintained at 35°C using mobile phase A [2 mM ammonium acetate in dichloromethane/acetonitrile 7:93 (v/v)] and mobile phase B [2 mM ammonium acetate in water-acetonitrile 50:50 (v/v)] in the following gradient ...
-
bioRxiv - Biochemistry 2024Quote: ... with Luna 3 µM HILIC column (Catalog no. 00D-4449-B0, 100 X 2 mm, Phenomenex, France) and subjected to a gradient (10/90 to 40/ 60 ...
-
bioRxiv - Microbiology 2024Quote: ... Metabolites were separated with a Luna NH2 column (2 mm × 100 mm, 3 µm particle size; Phenomenex). Mobile phase A was 20 mM ammonium acetate (pH 9.0) ...
-
bioRxiv - Physiology 2024Quote: LC-MS/MS chromatographic separation of bile acids was performed using a reverse phase C8 column (Phenomenex Luna C8, 150 × 2.0 mm, 3 µm) at a flow rate of 0.2 ml/min ...
-
bioRxiv - Plant Biology 2021Quote: ... Separation of metabolites was performed using a Luna C18 column (Phenomenex; 150 × 2 mm, 3 μm particle size). The mobile phase consisted of 97:3 water:methanol with 10 mM tributylamine and 15 mM acetic acid (solvent A ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 50 × 1 mm; Phenomenex, Torrence, CA) and SenCell (2 mm glassy carbon electrode ...
-
bioRxiv - Physiology 2020Quote: Samples were injected (10 μL) onto a Kinetex C18 column (150 × 3 mm; 2 μm, Phenomenex, Macclesfield, UK) at 40°C using a flow rate of 0.5 mL/min ...
-
bioRxiv - Microbiology 2022Quote: ... The column was a Gemini C18 (50 mm × 2 mm, 100 Å, particle size of 3-μm; Phenomenex). The mobile phases consisted of water (A ...
-
Systemic impact of the expression of the mitochondrial alternative oxidase on Drosophila developmentbioRxiv - Biochemistry 2022Quote: ... 10% of each sample was loaded onto a Luna NH2 (3 µm 100A, 150 mm x 2 mm, Phenomenex) column ...
-
bioRxiv - Microbiology 2021Quote: ... Five µl extracted samples were injected on the C18 column (Gemini, 3 µm, 2 x 150 mm, Phenomenex, CA) with the flow rate of 0.3 ml/min at 45°C ...
-
bioRxiv - Cell Biology 2021Quote: ... Analytes were separated on a Luna C18 column (30 × 2 mm, 3 μm, 100 Å; Phenomenex, Torrance, CA, USA). The mobile phase consisted of 2 mM ammonium acetate in 100% methanol ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Samples were then filtered and separated using a polar-RP column (Phenomenex, 150 x 2 mm; 4 µm) on an HPLC (Shimadzu ...
-
bioRxiv - Microbiology 2024Quote: ... All samples were vortexed and centrifuged at 10,000 x g for 3 min at 4 °C and then diluted with buffer A in conical polypropylene HPLC vials (Phenomenex, Torrance, CA) by 3-fold for analysis on the C18 Acclaim prior to mass spectrometry analysis.
-
bioRxiv - Neuroscience 2021Quote: ... Samples were injected onto a Prodigy C18 column (100Å∼2 mm I.D., 3-µm particle size, Phenomenex, Torrance, CA, USA). In the tissue homogenates ...
-
bioRxiv - Cell Biology 2024Quote: ... and peptide mixtures were separated on an NX 3u Gemini C18 column (150 mm x 2 mm, particle size 3 µM, pore size 110Å; Phenomenex) operated at 40°C with a flow rate of 200 µl/min using an Ultimate 3000 HPLC system ...
-
bioRxiv - Neuroscience 2024Quote: ... and trap columns (2 cm × 150 µm i.d.) were packed in-house with 3 µm Jupiter C18 particles (Phenomenex, Torrance). The long analytical column was placed in a column heater (Analytical Sales and Services ...
-
bioRxiv - Cancer Biology 2024Quote: ... and PPP intermediates and isotopomers were quantified using a Luna NH2 column (3 µm, 150 × 2 mm, Phenomenex, Torrance, CA) following a previously described method (28,29) ...
-
bioRxiv - Pathology 2021Quote: A HPLC binary pump (Waters 1525) attached to a C18 reverse-phase column 25x 4 mm Luna (2) (Phenomenex) and a diode array fluorescence detector (Waters 2475 ...
-
bioRxiv - Microbiology 2021Quote: ... Chromatographic separation was performed with an analytical Synergi 4u Hydro-RP 80A column (50 × 2 mm, 4 μm, Phenomenex). Mass transitions for c-di-AMP quantification were previously published (22) ...