Labshake search
Citations for Phenomenex :
1 - 50 of 52 citations for 18 0 PE square since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2024Quote: ... × 15 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 micron, Phenomenex). This system ran in-line with a Thermo Orbitrap Velos Pro hybrid mass spectrometer equipped with a nano-electrospray source (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2021Quote: ... x 15 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 micron, Phenomenex). This system runs in-line with a Thermo Orbitrap Velos Pro hybrid mass spectrometer ...
-
bioRxiv - Systems Biology 2022Quote: ... x 13.5 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 micron, Phenomenex). This system runs in-line with a Thermo Orbitrap Velos Pro hybrid mass spectrometer ...
-
bioRxiv - Molecular Biology 2024Quote: ... x 13.5 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 microns, Phenomenex). This system runs in-line with a Thermo Orbitrap Velos Pro hybrid mass spectrometer ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μm C-18 column (Phenomenex) kept at 35°C ...
-
bioRxiv - Plant Biology 2023Quote: ... A SPE cartridge C-18 (Phenomenex) was conditioned with 4 mL of methanol (100% ...
-
bioRxiv - Molecular Biology 2021Quote: ... x 15 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 micron, Phenomenex, Torrance, CA). This system ran in-line with a Thermo Orbitrap Velos Pro hybrid mass spectrometer ...
-
Identification of ABHD6 as a regulator of lysophosphatidylserines in the mammalian liver and kidneysbioRxiv - Biochemistry 2024Quote: ... A Gemini 5U C-18 column (Phenomenex) coupled with a Gemini guard column (Phenomenex ...
-
bioRxiv - Plant Biology 2023Quote: ... Plates were sealed with silicone covers (pierceable sealing mats, 96-square well, Phenomenex, Lane Cove, NSW, Australia) and vortexed for 30 s using a rack vortex mixer (MTV1 Multi Tube Vortex Mixer ...
-
bioRxiv - Microbiology 2021Quote: ... on a C-18 reverse phase column (Phenomenex – Gemini), at 25°C ...
-
bioRxiv - Immunology 2023Quote: ... 125 pore size C-18 silica-bonded stationary phase (Phenomenex) and resolved using a 100-min gradient at the flow rate of 0.2 μl min−1 (3–33% B for 90 min ...
-
bioRxiv - Immunology 2020Quote: ... and purified by HPLC using a C-18 Gemini column (Phenomenex) with a mobile phase of acetonitrile containing 0.1% TFA ...
-
bioRxiv - Microbiology 2024Quote: ... using a Kinetex C 18 column (Phenomenex; 2.6 µm EVO C18 100Å) and eluted by using the following binary solvent system ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... C-18 (2) with TMS end capping) were purchased from Phenomenex (Torrance, CA). Lutetium-177 in the form of lutetium chloride (177Lu-LuCl3 ...
-
Identification of ABHD6 as a regulator of lysophosphatidylserines in the mammalian liver and kidneysbioRxiv - Biochemistry 2024Quote: ... The LC separation was performed using a Gemini 5U C-18 column (Phenomenex) coupled with a Gemini guard column (Phenomenex ...
-
bioRxiv - Cell Biology 2024Quote: ... × cm pulled-tip C-18 column (Jupiter C18 300 Å, 5 microns, Phenomenex). We used a Thermo Q Exactive HF-X mass spectrometer equipped with a Nanospray Flex ion source (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2020Quote: ... Crude separation was achieved by using a RP-18 Strata column (500 mg/6 mL, Phenomenex). The following buffers were used sequentially for crude separation ...
-
bioRxiv - Microbiology 2020Quote: ... LC-MS was performed using a C-18 Kinetex analytical column (50 x 2.1 mm; Phenomenex). The presence of PalA was verified using MS/MS on an Agilent Technologies 6540 UHD Accurate-Mass QTOF LC-MS.
-
bioRxiv - Cell Biology 2021Quote: ... 100-μm-inner diameter trap column packed with 5 μm-diameter Aqua C-18 beads (Phenomenex) and a 40-cm-long ...
-
bioRxiv - Neuroscience 2022Quote: ... Chromatographic separation was achieved using a Kinetex XB C-18 (50 × 4.6 mm, 2.6 μm; Phenomenex) and a mobile phase consisting of 100 mM Na2HPO4 ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Chromatographic separation was conducted on a LC C-18 column (50 × 3 mm, 1.7 μm, Phenomenex) at 30°C ...
-
bioRxiv - Plant Biology 2023Quote: ... Chromatographic separation was applied using a reverse phase C-18 column (Kinetex, Phenomenex, Torrance, CA, USA) by injecting 100 µL of the sample to the column (100 mm ξ 3 mm ξ 2.6 µm ...
-
bioRxiv - Cell Biology 2022Quote: ... two 1.0 mm Empore C18 filter plugs were added to a pipette tip and 2 mg 5μm C18 resin (Phenomenex) was added to the top of the C18 filter plug ...
-
bioRxiv - Systems Biology 2023Quote: ... A Kinetex Core-Shell 100 Å column C-18 column (1 x 150 mm, 1.7 µm, Phenomenex) was used for separation of metabolites ...
-
bioRxiv - Plant Biology 2022Quote: ... Shimadzu HPLC will be used to separate the pigments on the C-18 column (250 × 4.6 mm, 5μm; Phenomenex). The isocratic system of methanol ...
-
bioRxiv - Plant Biology 2024Quote: ... LC was performed with a C-18 column (Kinetex C18 analytical column, 1.7 µm particle size, 50 mm□×□2.1 mm (Phenomenex)).
-
bioRxiv - Cancer Biology 2024Quote: ... the mixture was purified by a C-18 reverse-phase cartridge (Strata-X Solid Phase Extraction, SPE; Phenomenex) and eluted in 50% ethanol saline solution ...
-
bioRxiv - Plant Biology 2020Quote: ... equipped with a photodiode array detector and separated using a Gemini C-18 column (150 × 2.00 mm, 5 μm; Phenomenex) with a flow rate of 0.5 mL per minute and the following solvents and binary gradient ...
-
bioRxiv - Biochemistry 2020Quote: ... The samples were run on a C-18 Omega Polar HPLC column (Phenomenex, 250 x 4.6mm, 5μm particle size) with the following method ...
-
bioRxiv - Cell Biology 2021Quote: ... self-packed with C-18 reverse-phase resin (Jupiter 5 um particles, 300 Å pore size; Phenomenex, Torrance, CA, USA) using a high- pressure packing cell on the Easy-nLC II system (Proxeon Biosystems ...
-
bioRxiv - Biochemistry 2021Quote: ... The samples were eluted on a C-18 Omega Polar HPLC column (Phenomenex, 250 × 4.6 mm, 5 mm particle size) using 50:50 acetonitrile:H2O for 3 min ...
-
bioRxiv - Biochemistry 2020Quote: ... Synthesized DNA sequences were de-protected according to the base modification employed and purified using HPLC (Waters) equipped with a C-18 reversed-phase column (Phenomenex) and UV detector using 0.1M TEAA as the mobile phase ...
-
bioRxiv - Pathology 2022Quote: A fraction of glandular samples was lysed and 1 mL of supernatant was applied to a STRATA C-18 solid phase extraction cartridge (Phenomenex). Anandamide and 2-arachidonylglycerol were quantified by reverse phase high performance liquid chromatography (HPLC) ...
-
bioRxiv - Microbiology 2023Quote: ... digested samples were loaded onto a fused silica capillary column with a 5-μm electrospray tip and packed in house with 18 cm of Luna C18 3 μM particles (Phenomenex). The column was then placed in line with a Q-exactive mass spectrometer (ThermoFisher ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Ltd., Hachioji, Tokyo, Japan) using a Kinetex C-18 (5 μm, 250 × 4.6 mm) column (Phenomenex Inc., Torrance, CA, USA) and applying a gradient of 30–100% aqueous AcN in 30 min followed by 100% AcN for another 10 min at a flow rate of 1 mL/min.
-
bioRxiv - Microbiology 2024Quote: ... Separation was done via reverse phase with an RP-18 column (Phenomenex Gemini, 3µm NX-C18 110A, 50 × 2 mm) with a respective column guard (5 × 2 mm ...
-
bioRxiv - Synthetic Biology 2023Quote: ... Isolation of all compounds was done using a semi-preparative RP-18 column (250 × 10.0 mm, 5 μm, Hyperclone ODS C18 column, Phenomenex, Aschaffenburg, Germany) operating with a flow rate of 4.8 mL/min ...
-
bioRxiv - Genetics 2023Quote: ... Separation of allantoin was performed on a Synergy Hydro-RP C-18 reversed-phase column (250 × 4.6 mm I.D., 5 m particle size) from Phenomenex (Torrance, CA, USA). Allantoin elution (at 4 min ...
-
bioRxiv - Cancer Biology 2023Quote: ... and the crude mixture was purified on a reversed-phase high-performance liquid chromatography (RP-HPLC) system using a preparative C-18 Phenomenex column (5 mm, 21.5 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution starting with 10% acetonitrile ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... and 15-HETE) was performed on a Kinetex C-18 LC-column (100 Å, 1.3 μm, 2.1 × 50 mm, Phenomenex, Torrance, CA) using a Nexera X2 UHPLC system (Shimadzu ...
-
bioRxiv - Cancer Biology 2024Quote: ... and the crude mixture was purified on a reversed-phase high-performance liquid chromatography (RP-HPLC) system using a preparative C-18 Phenomenex column (5 mm, 21.5 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution starting with 5% acetonitrile ...
-
bioRxiv - Cancer Biology 2024Quote: ... DMF was evaporated using a rotary evaporator under reduced pressure and the residual product was purified on a RP-HPLC system using a semi-preparative C-18 Luna column (5 mm, 21.5 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution starting with 5% acetonitrile ...
-
bioRxiv - Developmental Biology 2020Quote: ... with C-18 reverse-phase material and high pressure packing cells (Jupiter 5 µm particles, 300 Å pore size; Phenomenex, Torrance, CA). LC-MS/MS data was acquired using a data-dependent top11 method combined with a dynamic exclusion window of 30 sec ...
-
bioRxiv - Cancer Biology 2023Quote: ... DMF was evaporated using a rotary evaporator under reduced pressure and the residual product was purified on a RP-HPLC system using a semi-preparative C-18 Luna column (5 mm, 10 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution started with 5% acetonitrile ...
-
bioRxiv - Cancer Biology 2023Quote: ... The reaction mixture was incubated at 65 °C for 30 min and then purified on a RP-HPLC system using a semi-preparative C-18 Luna column (5 mm, 10 x 250 mm Phenomenex, Torrance, CA). The HPLC gradient elution condition started with 5% acetonitrile ...
-
bioRxiv - Cancer Biology 2023Quote: ... The reaction mixture was incubated for 12 min at 65 °C in a temperature-controlled heating block and purified on a RP-HPLC system using a semi-preparative C-18 Luna column (5 mm, 10 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution starting with 5% acetonitrile ...
-
bioRxiv - Neuroscience 2024Quote: ... Identity was confirmed by coinjection of authentic standard on an analytical HPLC column (Phenomenex Gemini C-18, 5 μm, 4.6 × 250 mm) with mobile phase 10 mM sodium phosphate dibasic ...
-
bioRxiv - Cancer Biology 2024Quote: ... The reaction mixture was incubated for 12 min at 65 °C in a temperature-controlled heating block and purified on a RP-HPLC system using a semi-preparative C-18 Luna column (5 mm, 10 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution starting with 20% acetonitrile ...
-
bioRxiv - Cancer Biology 2024Quote: ... The reaction mixture was incubated at 65 °C for 30 min and then purified on a RP-HPLC system using a semi-preparative C-18 Luna column (5 mm, 10 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution starting with 20% acetonitrile ...
-
bioRxiv - Biochemistry 2021Quote: ... equipped with UV-Vis DAD detector on a C-18 reverse-phase column (Phenomenex, Gemini 5μm NX-C18 110 Å, 250 × 4.6 mm). The HPLC method used for analysis was derived from the one previously used to assay MjRibK.[2] The mobile phases used were 10 mM ammonium acetate pH 6.5 (Solvent-A ...