Labshake search
Citations for Phenomenex :
251 - 300 of 496 citations for TD 5108 CAS 866933 46 2 99% since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2021Quote: Analyte separation was achieved using a Gemini 3u C6-Phenyl 110A 100×2 mm column (Phenomenex) kept at 35 °C using a Shimadzu CTO-20AC column oven ...
-
bioRxiv - Biochemistry 2024Quote: ... Samples were applied to a Luna C8 column (2 x100 mm, Phenomenex, cat. 00D-4248-B0) and eluted with a linear gradient using H2O with 0.1% acetic acid as solvent A and acetonitrile with 0.1% acetic acid as solvent B ...
-
bioRxiv - Cell Biology 2023Quote: HPLC purification was performed on a semi-preparative column (Phenomenex Inc. Luna© 5µm C18(2) 100 Å 10 × 250 mm ...
-
bioRxiv - Biochemistry 2022Quote: ... Peptides were separated on a reverse phase column (Phenomenex Onyx Monolithic C18 column, 100 × 2 mm) at 1 °C using a flow rate of 500 μl/min under the following conditions ...
-
bioRxiv - Microbiology 2022Quote: ... 1 mL of bacterium suspension was transferred into 2 mL glass vials (AR0-37K0-13, Phenomenex) and sealed with designated caps (AR0-5760-13 ...
-
bioRxiv - Microbiology 2020Quote: ... USA) equipped with a KinetexLJ C8 column (2.1 × 50 or 100 mm, 1.7 µm, 100 Å, Phenomenex, Torrance, CA, USA) injected with 0.5 or 1 µl samples ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... The chosen column was a Luna Omega polar C18 (100×2.1 mm, 1.6 µm particle size) (Phenomenex, Torrance, CA, USA), since it has more affinity for polar compounds ...
-
bioRxiv - Cell Biology 2021Quote: ... self-packed with C-18 reverse-phase resin (Jupiter 5 um particles, 300 Å pore size; Phenomenex, Torrance, CA, USA) using a high- pressure packing cell on the Easy-nLC II system (Proxeon Biosystems ...
-
Multi-Omic Analysis Reveals Disruption of Cholesterol Homeostasis by Cannabidiol in Human Cell LinesbioRxiv - Systems Biology 2021Quote: ... equipped with a guard column (SecurityGuardTM Ultracartridge – UHPLC C18 for 2.1 mm ID Columns – AJO-8782 – Phenomenex, Torrance, CA, USA) (A ...
-
bioRxiv - Microbiology 2021Quote: ... liquid chromatographic separation was conducted with a Kinetex HILIC column (100-mm length, 4.6-mm internal diameter, 2.6-µm particle size; Phenomenex, Torrance, CA) using a 1260 HPLC system (Agilent Technologies ...
-
bioRxiv - Biophysics 2020Quote: ... The affinity purified protein was further separated by gel filtration using a Phenomenex Yarra 3µm SEC-4000 300 x 7.8mm column (Phenomenex, Torrance CA) in GF150 buffer (25 mM HEPES pH 7.4 ...
-
bioRxiv - Pathology 2022Quote: ... 360µm OD x 100µm ID fused silica tip packed with Aeris Peptide 3.6µm XB-C18 100Å material (Phenomenex, Torrance, CA, USA). Peptides were eluted under a 90min 2%-44% acetonitrile gradient and transferred by Nanospray Flex nanoelectrospray source (ThermoFisher ...
-
bioRxiv - Plant Biology 2021Quote: ... 2 µL of each sample were injected onto the reversed-phase column (Kinetex C18 100A, length 50 mm, diameter 2.1 mm, particle size 1.7 μm; Phenomenex, CA, USA) and analysed by an Acquity UPLC H-Class System (Waters ...
-
bioRxiv - Biochemistry 2020Quote: ... The radio-HPLC conditions were as follows: 150 × 4.6 mm Jupiter 5μ C18 300 Å column (Phenomenex, Torrance, CA, USA); flow rate =□1 mL/min ...
-
bioRxiv - Microbiology 2020Quote: ... Japan) equipped with a Kinetex C18 column (100mm length x 2.1mm i.d., 2.6 μm particle size) (Phenomenex, Torrance, CA, USA) at 50°C ...
-
bioRxiv - Synthetic Biology 2020Quote: ... A Phenomenex Rezex™ ROA-Organic Acid H+ (8%) (30 x 4.6 mm; CAT#: 00A-0138-E0, Phenomenex, Torrance, CA) was used for a 30 minute isocratic separation using a mobile phase of 5 mM H2SO4 ...
-
bioRxiv - Physiology 2020Quote: ... and the filtrate was placed in a GC autosampler vial and injected into a Zebron Capillary Gas Chromatography column (length 30m, internal diameter 0.25 mm, film thickness 0.25 µm; (ZebronTMZB-FFAP, Phenomenex, Torrance, CA). The SCFA analysis was completed using the Thermo Scientific Gas Chromatography system (Model Trace 1310 ...
-
bioRxiv - Biochemistry 2021Quote: ... UK) and an Acquity UPLC equipped with a reverse phase C4 Aeris Widepore 50□×□2.1Lmm HPLC column (Phenomenex, CA, USA). Mobile phases of ...
-
bioRxiv - Synthetic Biology 2021Quote: ... The effluent of the GC column (ZB-5MS fused silica capillary column (30 m × 0.25 mm i.d. × 0.25 μm; Phenomenex Inc., Torrance, CA) was split 1:40 for simultaneous detection between the MS and the EAD apparatus ...
-
bioRxiv - Synthetic Biology 2021Quote: ... The GC was equipped with a ZB-5MS fused silica capillary column (30 m × 0.25 mm i.d. × 0.25 μm; Phenomenex Inc., Torrance, CA). The oven was held at 60 °C for 1 min then was raised by 10 °C min-1 up to 110 °C ...
-
bioRxiv - Cancer Biology 2020Quote: ... a ZebronTM ZB-624 column (30 m x 0.32 mm x 1.80 mm, 5% cyanopropylphenyl-94% dimethylpolysiloxane, Phenomenex, Torrance, CA) was used ...
-
bioRxiv - Neuroscience 2023Quote: ... the peptides were eluted onto an analytical column (Jupiter C18, 0.5 x 50 mm, 5 µm, 300 Å, Phenomenex, CA) and separated by a 17 min two-stage linear gradient elution which was starting with 10% buffer B in buffer A and rising to 65% buffer B (began with 13 min stage 10-30% B followed by 4 min 30-65% B ...
-
bioRxiv - Physiology 2023Quote: ... v/v) to adjust to pH 3 and applied to 33 μm polymeric reverse phase extraction columns (Phenomenex, CA, USA) pre-conditioned with methanol and pH 3 water ...
-
bioRxiv - Developmental Biology 2023Quote: ... equipped with a guard column (SecurityGuardTM Ultracartridge – UHPLC C18 for 2.1 mm ID Columns – AJO-8782 – Phenomenex, Torrance, CA, USA) using an aqueous phase (A ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... equipped with a ZB-5MS fused silica capillary column (30 m x 0.25 mm ID, df= 0.25 μm) from Phenomenex (Torrance, CA) was used to profile the gland contents ...
-
bioRxiv - Plant Biology 2022Quote: The pABA was separated on a reverse-phase Luna C18 column (5 µm particle size, 150 mm x 4.60 mm I.D.) (Phenomenex, CA, USA) using a gradient elution program ...
-
bioRxiv - Molecular Biology 2022Quote: ... × 150 mm fused silica capillary packed in house with 4 μm 80 Å Synergi Hydro C18 resin (Phenomenex; Torrance, CA)) was then switched online at 600 nL/min for 10 minutes to load the sample ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... PFAS metabolites were separated with a Phenomenex Kinetex PS C18 100A (2.6μm, 100 x 4.6mm) column (Phenomenex, Torrance, CA, USA) via a gradient method consisting of mobile phase A ...
-
bioRxiv - Molecular Biology 2024Quote: ... Both systems were equipped with Zebron ZB-wax capillary columns (30 m, 0.25 mm ID and film thickness 0.25 µm; Phenomenex, CA, USA). The FA compositions were expressed as mol-% profiles.
-
bioRxiv - Plant Biology 2023Quote: Absorbance was measured on a UV detector at 228 nm on a 3 μm C18 column (Phenomenex, Torrance, CA, USA), 150 mm in length and 2.1 mm internal diameter ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Ltd., Hachioji, Tokyo, Japan) using a Kinetex C-18 (5 μm, 250 × 4.6 mm) column (Phenomenex Inc., Torrance, CA, USA) and applying a gradient of 30–100% aqueous AcN in 30 min followed by 100% AcN for another 10 min at a flow rate of 1 mL/min.
-
bioRxiv - Cell Biology 2022Quote: ... × 150 mm fused silica capillary packed in house with 4 μm 80 Å Synergi Hydro C18 resin (Phenomenex; Torrance, CA)) was then switched on-line at 600 nL/min for 10 min to load the sample ...
-
bioRxiv - Biochemistry 2022Quote: ... This MS was coupled to a CapLC (Waters Co. Milford, MA, USA) HPLC with a Phenomenex C18 (3μm, 300A, 100μm ID × 150mm, Phenomenex, Torrence, CA) analytical column ...
-
Macrodomain Mac1 of SARS-CoV-2 Nonstructural Protein 3 Hydrolyzes Diverse ADP-ribosylated SubstratesbioRxiv - Biochemistry 2023Quote: ... the LC is equipped with a KINEX 2.6 μm Polar C18 (2.1 x 50 mm, 100 Å, Phenomenex, CA, USA) set to 30°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... The GC was equipped with a ZB-5MS fused silica capillary column (30m × 0.25mm i.d. × 0.25 μm; Phenomenex Inc., Torrance, CA). The oven was held at 60°C for 1 min then was raised by 10°C/min up to 120°C ...
-
bioRxiv - Genetics 2024Quote: ... equipped with a guard column (SecurityGuardTM Ultracartridge – UHPLC C18 for 2.1 mm ID Columns – AJO-8782 – Phenomenex, Torrance, CA, USA) using an aqueous phase (A ...
-
bioRxiv - Microbiology 2024Quote: ... The GC-P-IRMS system consists of a Trace 1310 GC fitted with a programmable temperature vaporization (PTV) injector and either a 30 m ZB5HT column (i.d. = 0.25 mm, 0.25 μm, Phenomenex, Torrance, CA, USA) or a 60 m DB1 column (i.d ...
-
bioRxiv - Molecular Biology 2024Quote: ... The peptide mixture was loaded on a home-made 15 cm-long pulled-tip analytical column (75 µm i.d.) packed with 3µm reverse-phase beads (Aqua C18, Phenomenex, Torrance, CA) connected to an Easy-nLC 1000 nano HPLC (Thermo Scientific ...
-
bioRxiv - Developmental Biology 2024Quote: ... equipped with a guard column (SecurityGuardTM Ultracartridge – UHPLC C18 for 2.1 mm ID Columns – AJO-8782 – Phenomenex, Torrance, CA, USA) using an aqueous phase (A ...
-
bioRxiv - Cancer Biology 2024Quote: ... peptides were fractionated via a C18 column (150 × 2.0 mm Gemini-NX, 3 µm, C18 110Å, Phenomenex, Torrance, CA, USA) on a Dionex UltiMate 3000 nanoLC (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2024Quote: ... The system comprised a Trace 1310 GC fitted with a programmable temperature vaporization (PTV) injector and either a 30 m ZB5HT column (i.d. = 0.25 mm, 0.25 μm, Phenomenex, Torrance, CA, USA) or a 60 m DB1 column (i.d ...
-
bioRxiv - Biochemistry 2024Quote: ... equipped with a guard column (SecurityGuardTM Ultracartridge – UHPLC C18 for 2.1 mm ID Columns – AJO-8782 – Phenomenex, Torrance, CA, USA) using an aqueous phase (A ...
-
bioRxiv - Biochemistry 2020Quote: ... peptides were separated on a reverse phase (RP) column (Phenomenex Onyx Monolithic C18 column, 100 × 2 mm) at 1 °C using a flow rate of 500 μL/min under the following conditions ...
-
bioRxiv - Synthetic Biology 2022Quote: ... samples (soil and liquid culture) were added to 2 mL gas-tight vials (AR0-37L0-13, Phenomenex) and crimped with VEREX tops (AR0-5710-13 ...
-
bioRxiv - Physiology 2022Quote: ... Triglyceride species were separated chromatographically on a C5 column (Luna, 100 x 2 mm, 5 μm, Phenomenex). Mobile phase A was composed of 95:5 ratio of water:methanol ...
-
bioRxiv - Molecular Biology 2023Quote: ... chromatographic separation was performed on a Luna® NH2 column (100 mm × 2 mm, 3 μm; Phenomenex) maintained at 35°C using mobile phase A [2 mM ammonium acetate in dichloromethane/acetonitrile 7:93 (v/v)] and mobile phase B [2 mM ammonium acetate in water-acetonitrile 50:50 (v/v)] in the following gradient ...
-
bioRxiv - Microbiology 2024Quote: ... Sub-fraction 7 (25 mg) was subjected to reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Microbiology 2024Quote: ... Sub-fraction 8 (67 mg) was purified by reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Metabolites were separated with a Luna NH2 column (100 mm × 2 mm, 3 μm particle size, Phenomenex). The column was maintained at 15℃ with a solvent flow rate of 0.3 mL min−1 ...
-
bioRxiv - Microbiology 2023Quote: ... 5 min) and 2 mL were filtered (15 mm ∅, 0.2 µm regenerated cellulose filter, Phenomenex, Torrance, USA). Then ...