Labshake search
Citations for Phenomenex :
251 - 275 of 275 citations for Potassium 3 4 difluorophenyl trifluoroborate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2024Quote: ... Samples were loaded into a precolumn (150 μm i.d., 4 cm length, packed in-lab with Jupiter C18 packing material, 300 Å pore size, 5 μm particle size; Phenomenex) using mobile phase A (0.1% formic acid in water) ...
-
bioRxiv - Microbiology 2024Quote: Approximately 500 ng of peptides were injected onto a primary trap column (4 cm x 150 µm i.d. packed with 5 µm Jupiter C18 particles (Phenomenex, Torrence, CA)) and separated in a capillary column (70 cm x 75 µm i.d ...
-
bioRxiv - Physiology 2024Quote: LC-MS/MS chromatographic separation of bile acids was performed using a reverse phase C8 column (Phenomenex Luna C8, 150 × 2.0 mm, 3 µm) at a flow rate of 0.2 ml/min ...
-
bioRxiv - Plant Biology 2024Quote: A methanolic extract of the QC material was diluted 1:1 with H2O + 0.1% FA and semi-purified using a solid phase extraction (SPE; StrataX 33 μM, 30 mg, 3 mL tube; Phenomenex, Torrance, CA, United States) method adapted from Redan and others (Redan et al. ...
-
bioRxiv - Biochemistry 2021Quote: ... using a gradient of buffer A and buffer B from 20% B to 70% over 40 minutes at 4 ml/min using a Gemini 10μm NX-C18 110Å LC column (Phenomenex, Torrance, CA, USA). Analytical RP-HPLC was carried out on a Gemini 5μm C18 110Å LC column (Phenomenex ...
-
bioRxiv - Biochemistry 2022Quote: ... The samples were then filtered and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 × 4.6 mm, 4 µm) with a flow rate of 1 mL/min and elution consisting of 5% solvent B for 3 min ...
-
bioRxiv - Biochemistry 2022Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which was previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Cell Biology 2022Quote: ... Purified peptides were pressure-loaded onto a 250 mm silica capillary tubing filled with 4 cm of Aqua C18 reverse-phase resin (Phenomenex # 04A-4299). The samples were then attached using a MicroTee PEEK 360 µm fitting (Thermo Fisher Scientific #p-888 ...
-
bioRxiv - Microbiology 2021Quote: We performed the LC-MS/MS analysis on a reversed phase C18 column (Phenomenex Synergi Fusion, 2.1 x 150 mm, 4 µm) coupled via heated electrospray ionization (ESI ...
-
bioRxiv - Neuroscience 2022Quote: ... chromatography was carried out on a Synergy Fusion RP \SI 80 Å column (150 x 2.0 mm id, 4 µm, Phenomenex, Aschaffenburg, Germany) using the following solvent gradient (0.2 mL/min ...
-
bioRxiv - Biochemistry 2023Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which had been previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Biochemistry 2023Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which was previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Plant Biology 2022Quote: ... The separation of the analytes was performed using a Gemini C18 column (50 mm × 2 mm, 110 Å and particle size 3 μm) (Phenomenex, Palo Alto, CA, USA). Mobile phases consisted of water (solvent A ...
-
bioRxiv - Pathology 2022Quote: Chromatographic methods were identical for both instruments and the compounds were separated on either instrument with a Kinetex C8 (Phenomenex, 150 × 3 mm, 2.6 μm) with a flow rate of 0.4 ml/minute and mobile phases consisting of 0.1% formic acid for mobile phase A and acetonitrile for mobile phase B ...
-
bioRxiv - Biochemistry 2022Quote: ... Reactions quenched with mBBr were filtered and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 × 4.6 mm, 4 µm) with a flow rate of 1 mL/min and an elution program consisting of a 5% solvent B wash for 3 min ...
-
bioRxiv - Molecular Biology 2020Quote: ... Three µl of each sample was loaded onto a 30 cm fused silica 75 µm column and 3.5 cm 150 µm fused silica KASIL 1 frit trap (PQ Corporation, Malvern, PA, USA) loaded with 4 µm Jupiter C12 Proteo reverse-phase resin (Phenomenex, Torrance, CA, USA) and analyzed with Thermo Fisher Scientific EASY-nLC ...
-
bioRxiv - Biochemistry 2024Quote: ... The samples were then filtered and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 x 4.6 mm, 4 µm) with a flow rate of 1 mL/min ...
-
bioRxiv - Neuroscience 2023Quote: ... Dried metabolite pellets were reconstituted in 50% ACN and filtered using PHENEX-RC 4 mm syringe filter (Phenomenex, cat. no AF0-3203-52). Metabolites were separated using a Hydrophilic Interaction Liquid Chromatography (HILIC ...
-
Shear stress and very low levels of ligand synergize to activate ALK1 signaling in endothelial cellsbioRxiv - Cell Biology 2023Quote: ... The digest mixture was dialyzed into 4 mM HCl before being loaded onto a 10 x 250 mm 2 μm C18 Jupiter reverse phase column (Phenomenex, Torrance, CA USA) equilibrated in 95% A/5% B (where A and B are water and acetonitrile with 0.1% TFA) ...
-
bioRxiv - Microbiology 2022Quote: ... mass spectrometer fitted with an Exion UHPLC system having a Kinetex 2.6 mm hydrophilic interaction liquid chromatography (HILIC) column (100 Å particle size, 150 mm length, and 3 mm internal diameter; Phenomenex, Intek Chromasol Pvt. Ltd., India). Nitrogen was used as the nebulizer gas ...
-
bioRxiv - Biochemistry 2023Quote: ... Samples were loaded into a precolumn (150 μM i.d., 4 cm length, packed in-lab with Jupiter C18 packing material, 300 Å pore size, 5 μM particle size: Phenomenex, Torrance, CA, USA) using mobile phase A (0.1% formic acid in water) ...
-
bioRxiv - Microbiology 2023Quote: ... Analysis with a sample volume of 40 µL was carried out using a Chromaster HPLC-System (Hitachi, Tokyo, Japan) equipped with a SecurityGuard Cartridge Carbo-H (4×3.0 mm; Phenomenex Inc., Torrance, CA, United States) and a Rezex ROA-Organic Acid H+ (300×7.8 mm ...
-
bioRxiv - Microbiology 2020Quote: ... 5 µL of diluted supernatant was injected into the LC/MS/MS system (AB API 5500 LC/MS/MS instrument with a Phenomenex Synergi 2.5µm Polar-RP 100A (50 × 3 mm) column ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... 10 µL of the reaction mixture was injected onto Synergi 4 µM Hydro-RP 80 Å LC Column 150 × 4.6 mm (Phenomenex, Part No: 00F-4375-E0) fitted with a SecurityGuard Cartridges AQ C18 4 × 3.00 mm ID (Phenomenex ...
-
bioRxiv - Cell Biology 2022Quote: Chromatographic analysis was performed with the DIONEX Ultimate 3000 HPLC system coupled to a chromatographic column (Phenomenex Synergi 4 u Hydro-RP 80A 250_3.0 mm) set at 40°C and a flow rate of 0.9 mL/min ...