Labshake search
Citations for Phenomenex :
201 - 250 of 570 citations for 7 Diethylamino 3 ethylamino 2 methylphenoxazin 5 ium tetrachlorozincate 2 1 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Systems Biology 2021Quote: ... and 4 x 3 mm ID Carbo-H guard (Phenomenex, Torrance, CA). The column was maintained at 50 °C and 1.5 mM H2SO4 was used as the mobile phase at a flow rate of 0.6 mL/min ...
-
bioRxiv - Microbiology 2023Quote: Protein samples were injected onto a Yarra 3 µm SEC-2000 (Phenomenex) running at room temperature in 150 mM NaCl ...
-
bioRxiv - Microbiology 2024Quote: ... An Aqua 3u C18 125A (100×2.0mm 3 µm, Phenomenex, Torrance, USA) column was utilized ...
-
bioRxiv - Molecular Biology 2024Quote: ... and a YarraTM 3 μm SEC-3000 (300 x 7.8 mm; Phenomenex), with a isocratic flow rate of 0.5 ml/min ...
-
bioRxiv - Biochemistry 2023Quote: Analytical RP-HPLC on an analytical C18 column (Aeris 5 μm PEPTIDE XB-C18, 4.6 × 250 mm, 100 Å, Phenomenex, flow rate 1 mL/min) connected to a Shimadzu LC-40D solvent delivery system equipped with a SIL-40C autoinjector and an SPD-40D UV–vis detector was used to determine the purity of purified peptides ...
-
bioRxiv - Microbiology 2019Quote: ... LC Column (5 μm, 150 × 2.1 mm; Phenomenex, US) as follows ...
-
bioRxiv - Microbiology 2019Quote: ... LC Column (5 μm, 150 × 2.1 mm; Phenomenex, US) as follows ...
-
bioRxiv - Microbiology 2021Quote: ... The chromatography used LUNA NH2 resin (5 µm, Phenomenex) as stationary phase packed in 0.1 mm ID × 70 mm L silica capillaries ...
-
bioRxiv - Synthetic Biology 2023Quote: ... A Zebron ZB-5 capillary column (Phenomenex, CA, USA) was used with He as the carrier gas at a flow rate of 0.5 mL/min ...
-
bioRxiv - Microbiology 2022Quote: ... with a Kinetex C18 biphenyl column (2.6 um 50 x 3 mm Phenomenex) at 45°C with 98% MS-grade water (Sigma-Aldrich) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The trapping column (75 µm ID x length 3 µm Luna particles, Phenomenex) was run with 0.1% aqueous formic acid for 7 minutes at 5 µL/min ...
-
bioRxiv - Systems Biology 2023Quote: ... 0.3 mm inner diameter reversed phase column (Phenomenex, Luna Polar C18 3 um). A binary analytical gradient using 0.1 % formic acid in water (mobile phase A ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... and a Luna 5 µM C18 column (Phenomenex, CA, US) eluted at a flow rate of 1 mL/min with water (eluent A ...
-
bioRxiv - Biochemistry 2020Quote: ... Luna 5 µm 100 Å strong cation exchange resin (Phenomenex) and a second layer of C18 resin using a high pressure chamber(Fonslow et al. ...
-
bioRxiv - Biochemistry 2022Quote: ... 5 µm Polar C18 Luna Omega column (Phenomenex, Torrance, CA) using a linear gradient of 11% B to 100% B over 25 minutes with 5 minutes at final conditions and 8-minute re-equilibration ...
-
bioRxiv - Genetics 2023Quote: ... Luna® 5 μm C18 column (Phenomenex, Torrance, CA, U.S.A.). Water acidified with 0.1% formic acid was used as phase A and 100% acetonitrile was used as phase B with the following elution gradient ...
-
bioRxiv - Biochemistry 2023Quote: ... followed by 3.5 cm of 5 µm Luna SCX (Phenomenex), and last with 2.5 cm of 5 µm Aqua C18 ...
-
bioRxiv - Biochemistry 2024Quote: ... 1.5 cm Luna 5 µm SCX resin (Phenomenex # 04A-4398), and 1.5 cm 5 µm C18 resin ...
-
bioRxiv - Cell Biology 2019Quote: ... Reverse phase particles (Aqua C18, 3 mm dia., 125 Å pores, Phenomenex, Torrance, CA) were packed directly into the pulled column at 800 psi until they were 12-cm long ...
-
bioRxiv - Neuroscience 2020Quote: ... injected on a Yarra 3 μm SEC – 2000 column (300 x 7.8 mm, Phenomenex), and run at 0.7 ml/minute in 1x PBS ...
-
bioRxiv - Plant Biology 2021Quote: ... with the following modifications: a Lux 250 x 4.6mm 5u Cellulose-3 column (Phenomenex) was used ...
-
bioRxiv - Microbiology 2020Quote: ... using a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) with 20 mM ammonium formate (pH 10.0 ...
-
bioRxiv - Genetics 2019Quote: ... Reversed phase particles (Aqua C18, 3 □m dia., 125 Å pores, Phenomenex, Torrance, CA) were packed directly into the pulled column at 800 psi until 12 cm long ...
-
bioRxiv - Molecular Biology 2022Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 × 1.0 mm, Phenomenex), resulting in 5 fractions.
-
bioRxiv - Neuroscience 2023Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 × 1.0 mm, Phenomenex)64.
-
bioRxiv - Cell Biology 2023Quote: ... on a Yarra 3 µm SEC-2000 LC 300 x 4.6 mm column (Phenomenex) in 50 mM Tris-HCl ...
-
bioRxiv - Plant Biology 2023Quote: ... The eluates were loaded onto Strata-X SPE columns (60 mg/3 mL; Phenomenex), pre-washed with 1 mL hexane ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 cm of 5-μm strong cation exchange resin (Luna; Phenomenex), and 8 cm of reverse-phase C18 resin57 ...
-
bioRxiv - Microbiology 2020Quote: ... The column (Phenomenex Kinetex C18, 5 μm × 150 mm × 4.6 mm) was re-equilibrated before each injection and the column compartment was maintained at 30°C throughout each run ...
-
bioRxiv - Pathology 2022Quote: ... A Phenosphere-Next C18 column (5 μm, 4.6 × 250 mm, Phenomenex) was employed ...
-
bioRxiv - Biochemistry 2023Quote: ... HPLC was used (Phenomenex C4 column: 5 μm, 4.6 × 150 mm) with a 3-minute dwell time of 30% CH3CN/0.1% TFA and subsequent linear gradient from 30% CH3CN/0.1% TFA to 44% CH3CN/0.1% TFA applied over 28 minutes with a flow rate of 1 mL/min ...
-
bioRxiv - Systems Biology 2021Quote: ... equipped with a Gemini C18 column (3 µm, 110 Å, 100 x 1.0 mm, Phenomenex), (66) ...
-
bioRxiv - Systems Biology 2020Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) (47).
-
bioRxiv - Molecular Biology 2023Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) installed with a Gemini C18 ...
-
bioRxiv - Genomics 2023Quote: ... The column was a Gemini C18 column (3 m, 110 Å, 100 1.0 mm, Phenomenex) with a Gemini C18 ...
-
bioRxiv - Biochemistry 2023Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) (77).
-
bioRxiv - Biochemistry 2024Quote: ... coupled to a Gemini guard column (Phenomenex, 4 x 3 mm, catalog no.: AJ0-7597). The flow rate for the LC method was 0.5 mL/min ...
-
bioRxiv - Biochemistry 2024Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex)(81).
-
bioRxiv - Evolutionary Biology 2020Quote: ... The trap column is packed with 5 μm Aqua C18 beads (Phenomenex) while the analytical column is packed with 1.9 μm-diameter Reprosil-Pur C18-AQ beads (Dr ...
-
MBOAT7-Driven Phosphatidylinositol Remodeling Promotes the Progression of Clear Cell Renal CarcinomabioRxiv - Cancer Biology 2019Quote: ... HPLC Parameters: A silica column (2.1 × 50mm, Luna Silica, 5 μm, Phenomenex) was used for the separation of PI and LPI species ...
-
bioRxiv - Plant Biology 2021Quote: ... equipped with a Luna C18 column (250×4.6 mm, 5 μm; Phenomenex). The gradient elution conditions ...
-
bioRxiv - Microbiology 2019Quote: ... using a ZB-5 column (30 m × 25 mm × 25 mm; Phenomenex) operating a temperature program of 50°C for 10 min ...
-
bioRxiv - Microbiology 2019Quote: ... bare silica (Luna SiOH, 100 × 4.6 mm, 5 µm, 100 Å; Phenomenex), (III. ...
-
bioRxiv - Biophysics 2023Quote: ... 100 Å pore size and 5 µm particle size (Phenomenex, Torrence, USA). A linear gradient of eluent B (0.08% TFA in ACN (v/v) ...
-
bioRxiv - Cell Biology 2020Quote: ... Protein free supernatants were then injected into a Hypersil 3-μm ODS-C18 column (Phenomenex, USA) and eluted at 0.5 mL/min with a mobile phase consisting of 9% (v/v ...
-
bioRxiv - Molecular Biology 2021Quote: ... followed by packing with at least 15-cm reversed-phase 3 μm Aqua C18 resin (Phenomenex). After further MeOH wash and Buffer A pre-equilibration ...
-
bioRxiv - Systems Biology 2019Quote: ... Metabolites were separated on a Luna 3 µm NH2 100 Å (150 × 2.0 mm) column (Phenomenex). The flowrate was 300 µL/min ...
-
Inhibition of nucleotide synthesis promotes replicative senescence of human mammary epithelial cellsbioRxiv - Systems Biology 2019Quote: ... Metabolites were separated on a Luna 3 µm NH2 100 Å (150 × 2.0 mm) column (Phenomenex). The flowrate was 300 µl/min ...
-
bioRxiv - Immunology 2019Quote: ... about 3 μL digest in 40% acetonitrile was directly loaded to a C8 analytical column (Phenomenex C8 ...
-
bioRxiv - Plant Biology 2020Quote: ... This fraction was added to Strata-X SPE (8B-S100-UBJ 60 mg/3 mL; Phenomenex) that had been prewashed with 1 mL hexane ...