Labshake search
Citations for Phenomenex :
101 - 150 of 298 citations for Ammonium Polyphosphate phase II 02 since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2020Quote: ... Using a semi-preparative Jupiter® 5 µm 10×250 mm C18 reverse phase HPLC column (Phenomenex) protein was then purified by applying a gradient elution of 60 – 80 % acetonitrile containing 0.1% TFA on a UltiMate 3000 system (Thermo ...
-
bioRxiv - Synthetic Biology 2021Quote: ... coupled to a TSQ Quantiva mass spectrometer (Thermo) fitted with a Kinetex C18 reversed phase column (2.6 µm, 150 × 2.1 mm i.d., Phenomenex). The following LC solvents were used ...
-
bioRxiv - Systems Biology 2022Quote: ... a reverse-phase C18 Kinetex Evo column (Phenomenex, 100 mm x 2.1 mm, 1.7 μm particle size), or a reverse-phase C18 Kinetex Evo column (Phenomenex ...
-
bioRxiv - Microbiology 2024Quote: ... Sub-fraction 7 (25 mg) was subjected to reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Microbiology 2024Quote: ... Sub-fraction 8 (67 mg) was purified by reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Microbiology 2023Quote: ... A reversed-phase Luna® C18 column (150 mm × 2.0 mm, 5 μm) (Phenomenex, Torrance, CA, U.S.A.) was utilized with water acidified with 0.1% formic acid and 100% acetonitrile as mobile phases ...
-
bioRxiv - Microbiology 2024Quote: ... -10 °C for 10 min and aqueous upper phase was filtered through 0.2 µm PFTE filters (Phenomenex) and stored at -80 °C until analysis.
-
bioRxiv - Biochemistry 2023Quote: ... A 100×2.1 mm Kinetex EVO C18 reversed-phase column with 2.6 µm 100 Å particles (Phenomenex) was used for separation ...
-
bioRxiv - Molecular Biology 2023Quote: ... A kinetic XB-C18 reverse phase analytical column (2.1 x 100 mm, 2.6 μm, Phenomenex, Torrance, CA) was used for all chromatographic separations ...
-
bioRxiv - Biochemistry 2023Quote: ... and ran through a QQQ mass spec through a C18 reverse phase column (Phenomenex, 00B-4435-E0) at a 0.7ml/min flow rate ...
-
bioRxiv - Cell Biology 2023Quote: ... and then packing with 2.5-cm-long reversed-phase 5 µm Aqua C18 resin (125 Å, Phenomenex). C18 loading columns were washed with MeOH and Buffer A prior to analysis ...
-
bioRxiv - Neuroscience 2024Quote: ... equipped with a reverse-phase trapping column RP-2TM C18 trap column (0.075 x 10mm, Phenomenex, USA), followed by analytical separation on a bioZen C18 nano column (0.075 × 250 mm ...
-
bioRxiv - Cell Biology 2024Quote: ... was used for positive mode and a Gemini C18 reversed-phase column (5m, 4.6 x 50mm, Phenomenex) was used in negative mode ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... The HPLC method was based on a reversed-phase column (Phenomenex Kinetex C18 2.1 × 100mm 2.6 u) and solvents A (water + 0.1% formic acid ...
-
bioRxiv - Neuroscience 2024Quote: ... 100 µL of plasma supernatant was loaded onto a pre-conditioned reverse-phase (RP)-HPLC system (Phenomenex Kinetex EVO C18 5 μm HPLC column (150 x 4.6 mm ...
-
bioRxiv - Developmental Biology 2024Quote: ... and normal phase chromatography was performed using a silica column (150x2 mm, Luna Silica 5 µm, Phenomenex). The mobile phase system consisted of solvent A (isopropanol/hexane/water (58/40/2 ...
-
bioRxiv - Bioengineering 2022Quote: ... LC-20 AP with a diode array detector SPD-M20A (Shimadzu) with a reverse-phase column (Phenomenex, Kinetex) using a gradient from 15% acetonitrile with 0.1% formic acid to 100% acetonitrile ...
-
bioRxiv - Microbiology 2021Quote: ... These samples were desalted and concentrated using Strata™-X 33 µm Polymeric Reverse Phase SPE cartridges (Phenomenex) per manufacturer protocol ...
-
bioRxiv - Cell Biology 2020Quote: ... Samples were loaded on conditioned 30 mg/ml StrataX solid phase extraction (SPE) columns (Phenomenex, Torrance, CA, U.S.A.). Columns were washed with 2 ml MS grade water and eicosanoids were eluted with 500 µL methanol (MeOH abs. ...
-
bioRxiv - Biochemistry 2021Quote: ... Liquid chromatography was performed using a C18 reverse phase column (Kinetex Polar C18 Column; 100Å, 100 × 2.1 mm, 2.6 µm particle size, Phenomenex). Two mobile phases were used ...
-
bioRxiv - Plant Biology 2020Quote: ... An aliquot was injected on a Luna C18 reversed-phase column (3 μm, 150 × 2.0 mm; Phenomenex, USA), and the CK were eluted with an increasing gradient of 0.08% CH3COOH in CH3CN (A ...
-
bioRxiv - Biochemistry 2022Quote: ... A 20 uL aliquot was injected onto a reverse phase C18 column (Kinetex 2.6u C18 100 A, 2.1 × 50 mm; Phenomenex). Phytohormones (ABA ...
-
Dynamic states of eIF6 and SDS variants modulate interactions with uL14 of the 60S ribosomal subunitbioRxiv - Biochemistry 2022Quote: ... and peptides were separated on a reverse phase column (Phenomenex Onyx Monolithic C18 column, 100 x 2 mm) at 1 UC using a flow rate of 400 µl/min ...
-
bioRxiv - Microbiology 2022Quote: ... coupled to an analytical reverse-phase column Aqua® C18 (5 μm; 75 μm x 100 mm) (Phenomenex). Two eluents were employed ...
-
bioRxiv - Systems Biology 2022Quote: ... or a reverse-phase C18 Kinetex Evo column (Phenomenex, 100 mm x 2.1 mm, 1.7 μm particle size). Chromatographic separation with ZIC-pHILIC column was performed using mobile phase A ...
-
bioRxiv - Plant Biology 2024Quote: ... Each sample (1 µL) was then injected onto a reverse-phase column (Kinetex C18 100A, 50×2.1 mm, 1.7 μm; Phenomenex) and analyzed by the selected ion recording (SIR ...
-
bioRxiv - Microbiology 2024Quote: ... sub-fraction 5 (15 mg) was then subjected to reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Systems Biology 2023Quote: ... 5 µg of sample were injected onto a reverse phase HPLC column (Luna®Omega 1.6µm C18 100A, 30 × 2.1 mm, Phenomenex) and resolved by gradient elution at a flow rate of 800 µL/min and column temperature of 30 °C ...
-
bioRxiv - Synthetic Biology 2023Quote: ... The Kinetex C18 (100mm x 4.6 mm; 2.6 µm particle size) reverse-phase column was purchased from Phenomenex, U.S.A.
-
bioRxiv - Biochemistry 2024Quote: ... PG was isolated by solid phase extraction using a Strata® NH2 column (Phenomenex, Cat#8B-S009-JCL). For this purpose ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... The supernatant was applied to a reverse-phase column (C18, 250 x 4.6 mm, 5 µm particle; Phenomenex) equilibrated with the same solution and separated at 1 mL/min using an Agilent 1220 chromatography system monitored at 215 nm ...
-
bioRxiv - Systems Biology 2024Quote: ... The residue was purified by preparative-HPLC (column: Waters Xbridge C18 150*50mm* 10um; mobile phase: [column: Phenomenex luna C18 150*25mm* 10um;mobile phase ...
-
bioRxiv - Molecular Biology 2024Quote: ... equipped with a reverse-phase C18 column (Phenomenex Kinetex, 250 mm x 4.60 mm, 5 μm, 100 Å) and purified with (0–100)% acetonitrile gradient ran over 15 min followed by 15 min at 100% acetonitrile ...
-
bioRxiv - Cancer Biology 2021Quote: ... normal-phase chromatography was performed with a Luna 5 μm NH2 100 Å LC column (Phenomenex 00B-4378-E0). Mobile phases were as follows ...
-
bioRxiv - Molecular Biology 2021Quote: ... and then packing with 2.3- to 2.5-cm-long reversed-phase 5 μm Aqua C18 resin (125 Å, Phenomenex), 2.3- to 2.5-cm 5 μm strong cation exchange resin (100 Å ...
-
bioRxiv - Molecular Biology 2020Quote: ... 5 µL peptide solution was loaded on a Waters M-Class NanoAcquity LC equipped with C18 reversed phase column (packed in-house, length 70 cm, 75 µm ID, 3µm Jupiter particle from Phenomenex). Peptides were separated using water/acetonitrile mobile phases with 0.1% formic acid over a gradient of 2h (ramping acetonitrile gradient 1-40% ...
-
bioRxiv - Molecular Biology 2020Quote: The labelled samples were subsequently acidified and desalted using polymeric reversed phase (Strata X, Phenomenex or Oasis HLB, Waters). LC-MS grade liquids and low-protein binding tubes were used throughout the purification ...
-
bioRxiv - Cell Biology 2022Quote: ... Samples were fractionated on a high-pH reversed-phase C18 column (Kinetex 5u Evo C18 100A, 150 × 2.1mm, Phenomenex) coupled to an Agilent 1100 series HPLC over a 60 min gradient ...
-
bioRxiv - Genomics 2020Quote: ... and ramping up to 60% A in phase B (0.1% formic acid in acetonitrile) using a C18 reversed phase column (Kinetex 2.6 μm C18 100 Å, LC Column 150 × 2.1 mm; Phenomenex) and employing a flow rate of 100 μL/min ...
-
bioRxiv - Cancer Biology 2021Quote: Resuspended metabolites were separated by hydrophilic interaction chromatography with a Gemini reverse-phase C18 column (50 mm × 4.6 mm with 5 μm diameter particles) from Phenomenex together with precolumn (C18 ...
-
bioRxiv - Biophysics 2021Quote: ... The sample was fractionated using semipreparative Jupiter 5 μm-10 x 250 mm C18 reverse-phase HPLC column (Phenomenex) using a gradient elution of 60%–80% acetonitrile containing 0.1% TFA ...
-
bioRxiv - Microbiology 2021Quote: ... The samples were desalted using 30 mg/ml C18 polymeric reversed phase column (Strata-X 33u, Phenomenex, Torrance, CA) and analyzed using LCMS.
-
bioRxiv - Microbiology 2021Quote: ... Samples were desalted on a 4 cm reversed-phase trapping column (in-house packed, 150 μm i.d. 5 μm Jupiter C18 particle from Phenomenex) at 5 μL/min for 10 min ...
-
bioRxiv - Microbiology 2021Quote: ... The analytical separation was on a 70 cm reversed-phase column (in-house packed, 75 μm i.d. 3 μm Jupiter C18 particle from Phenomenex) at 0.3 μL/min over 2 h ...
-
bioRxiv - Cell Biology 2021Quote: ... Analytes were extracted using Strata-X 33 μm Polymeric solid reversed phase (SPE) extraction columns (8E-S100-TGB, Phenomenex). Columns were conditioned with 3 mL of 100% MeOH and then equilibrated with 3 mL of H2O ...
-
bioRxiv - Neuroscience 2022Quote: ... Neurotransmitters and their metabolites were separated on a Luna 100 × 3.0 mm C18 3 μm HPLC reversed-phase column (Phenomenex). The mobile phase consisted of 75 mM NaH2PO4 ...
-
bioRxiv - Biochemistry 2021Quote: UPLC analyses was carried out on a Waters Acquity Arc system with a reversed phase Luna Omega C18 column (150 x 2.1 mm; Phenomenex) with a flow rate of 0.2 ml/min ...
-
bioRxiv - Plant Biology 2020Quote: ... The chromatographic column was a C18 reverse phase column (LC Kinetex XB-C18 100 Å, 1.8 μm, 150 × 2.1 mm, Phenomenex). The products were separated using a gradient of solvent A (water with 0.1 (v/v ...
-
bioRxiv - Synthetic Biology 2020Quote: ... Peptides were separated across a 180 min organic gradient using an in-house pulled nanospray emitter packed with 15 cm of 1.7-micron Kinetex reversed-phase resin (Phenomenex). Peptide fragmentation spectra were analyzed/sequenced by Proteome Discoverer software (Thermo Scientific ...
-
bioRxiv - Pathology 2021Quote: A HPLC binary pump (Waters 1525) attached to a C18 reverse-phase column 25x 4 mm Luna (2) (Phenomenex) and a diode array fluorescence detector (Waters 2475 ...