Labshake search
Citations for Phenomenex :
451 - 500 of 594 citations for 2 Amino 6 chloro 9 3 5 di O p toluoyl beta D 2 deoxyribofurnanosyl purine since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2021Quote: ... and then packing with 2.3- to 2.5-cm-long reversed-phase 5 μm Aqua C18 resin (125 Å, Phenomenex), 2.3- to 2.5-cm 5 μm strong cation exchange resin (100 Å ...
-
bioRxiv - Plant Biology 2020Quote: ... equipped with a photodiode array detector and separated using a Gemini C-18 column (150 × 2.00 mm, 5 μm; Phenomenex) with a flow rate of 0.5 mL per minute and the following solvents and binary gradient ...
-
bioRxiv - Bioengineering 2020Quote: ... Samples were analyzed by isocratic elution using a 5 mM H2SO4 mobile phase at a constant flow rate of 0.5 mL min−1 on a REZEX ROA-organic acid H+ (8%) LC column (300 mm × 7.8 mm, Phenomenex). The column temperature was maintained at 55 °C and the refractive index detector was operated at 35 °C ...
-
bioRxiv - Biochemistry 2020Quote: ... The samples were separated via a C18 column (250 x 1 mm, 5 μm, 300 Å, Jupiter C18, Phenomenex) with a linear 10-min gradient from 2 % to 40 % solvent B ...
-
bioRxiv - Cancer Biology 2021Quote: Resuspended metabolites were separated by hydrophilic interaction chromatography with a Gemini reverse-phase C18 column (50 mm × 4.6 mm with 5 μm diameter particles) from Phenomenex together with precolumn (C18 ...
-
bioRxiv - Biophysics 2021Quote: ... The sample was fractionated using semipreparative Jupiter 5 μm-10 x 250 mm C18 reverse-phase HPLC column (Phenomenex) using a gradient elution of 60%–80% acetonitrile containing 0.1% TFA ...
-
bioRxiv - Neuroscience 2020Quote: ... capillary with a kasil frit which had been packed with 2.5 cm of 5-μm Partisphere strong cation exchanger (Whatman) followed by 2.5 cm of 10-μm Jupiter C18-A material (Phenomenex) After loading ...
-
bioRxiv - Microbiology 2021Quote: ... Samples were desalted on a 4 cm reversed-phase trapping column (in-house packed, 150 μm i.d. 5 μm Jupiter C18 particle from Phenomenex) at 5 μL/min for 10 min ...
-
bioRxiv - Plant Biology 2021Quote: ... Fractions 9–18 were combined (3.17 mg) and purified by HPLC on an ODS column (Kinetex C18, 4.6×250 mm, 5 μm; Phenomenex, USA) with a MeCN/H2O gradient system (30:70 to 100:00 over 40 min ...
-
bioRxiv - Systems Biology 2021Quote: ... The trapping column (100 µm ID) was packed with 10 cm of 5 µm Kinetex C18 RP resin (Phenomenex) while the nanospray emitter (75 µm ID ...
-
bioRxiv - Cell Biology 2021Quote: ... coupled to a strong cation exchange (SCX) separation column (Luna SCX 5 μm – 100 Å particles, 50 × 2mm, Phenomenex), resulting in 25 fractions.
-
bioRxiv - Cell Biology 2020Quote: ... equipped with a Luna 5 μm 100 angstrom 150 x 2.1 mm strong cation exchange (SCX) column (Catalog no 00F-4398-B0, Phenomenex). Buffer A was 5 mM KH2PO4 in 30% acetonitrile (Catalog no 34998 ...
-
bioRxiv - Biochemistry 2022Quote: ... SeGlcNAc-mBBr was purified by semi-preparative HPLC using a Luna C18 column (Phenomenex, 250 × 10 mm, 5 µm) with a flow rate of 2.5 mL/min and elution consisting of a gradient of 10–50% solvent B for 10 min ...
-
bioRxiv - Biochemistry 2022Quote: ... Neutral lipids were quantified by HPLC equipped with an ELSD (Evaporative Light Scattering Detector) using a cyanopropyl column (Luna 5 μm CN 100Å 250 x 4.6 mm; Phenomenex) with hexane as mobile phase A and methyl tertiary-butyl ether (MTBE):isopropanol (95:5 v/v ...
-
bioRxiv - Bioengineering 2020Quote: ... The resulting products were purified using a C4 Jupiter column (250 × 30 mm ID, 5 µm, Phenomenex, Torrance, CA) as described above ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Imtakt Corporation) for EPI-589 and Kinetex XB-C18 100A column (5 μm, 50 mm × 2.1 mm i.d., Phenomenex Inc.) for edaravone ...
-
bioRxiv - Biochemistry 2020Quote: ... were loaded onto a triphasic column filled sequentially with 1.5 or 2.5 cm layers of 5 µm 100 Å C18 resin (Phenomenex), Luna 5 µm 100 Å strong cation exchange resin (Phenomenex ...
-
bioRxiv - Biochemistry 2023Quote: ... and second by loading onto a C18 semi-preparative reverse phase column (Jupiter 5 μm C18 300 Å, Phenomenex) and eluting with a 5 - 70% acetonitrile gradient.
-
bioRxiv - Biochemistry 2023Quote: ... and second by loading onto a C18 semi-preparative reverse phase column (Jupiter 5 μm C18 300 Å; Phenomenex) and eluting with a 5 - 70% acetonitrile gradient.
-
bioRxiv - Neuroscience 2024Quote: ... pentose phosphate pathway and Krebs cycle intermediates) was performed using a cyano–phase LUNA column (50 mm x 4.6mm, 5 µm; Phenomenex) by a 5 min run in negative ion mode ...
-
bioRxiv - Neuroscience 2024Quote: ... Negative ion mode analysis was conducted with a cyano–phase LUNA column (50 mm X 4.6 mm, 5 μm; Phenomenex) and 5 mM ammonium acetate pH 7 in MetOH as isocratic mobile phase in 5 min total run for each sample ...
-
bioRxiv - Physiology 2023Quote: ... Separation of metabolites was conducted using a Luna 5 μm C5 100 Å LC column (Phenomenex 00B-4043-E0) with reverse phase chromatography ...
-
bioRxiv - Microbiology 2023Quote: ... then resolubilized in 3:1 acetonitrile to water and injected on a C18 analytical column (250x 4.6 mm, 5 µm, 100 Angstrom, Luna, Phenomenex) and separated on an Alliance HPLC (Waters ...
-
bioRxiv - Physiology 2023Quote: ... Separation of metabolites was conducted using a Luna 5 μm NH2 100 Å LC column (Phenomenex 00B-4378-E0) with normal phase chromatography ...
-
bioRxiv - Microbiology 2022Quote: ... equipped with a fused silica capillary column ZB–5 (30 m × 0.25 mm × 0.25 μm with 10 m guard column, Zebron, Phenomenex, USA). Helium at 1 ml · min-1 served as carrier gas with an injector temperature of 320 °C running in splitless mode ...
-
bioRxiv - Biochemistry 2023Quote: ... SpaB containing the reactive lysine is ligated to a FELPLTGGSG peptide (LPLTG peptide) by CdSrtAΔ and reactions are HPLC-quantified using a C4 column (5 µm, 4.6 × 150 mm; Phenomenex). Reactions were performed in 100 μL volumes and contained 25 µM of CdSrtAΔ ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Final purification was performed via analytical RP-HPLC using a C18 column (250 × 4.6 mm; 5 μm particle size; Phenomenex) at a flow rate of 1 mL/min using the same gradient ...
-
bioRxiv - Biochemistry 2023Quote: Quantification of energy metabolites and cofactors was performed using a cyano-phase LUNA column (50mm x 4.6mm, 5 µm; Phenomenex) with a 5.5 min run in negative ion mode with two separated runs ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... while purification was carried out employing a Luna C18 reverse phase column (5 μm, 150 x 21.2 mm, Phenomenex). Eluent A consisted of H2O with 0.1% formic acid (FA) ...
-
bioRxiv - Biochemistry 2024Quote: ... Metabolite separation was achieved with a Luna reverse-phase C5 column (50 x 4.6 mm, with 5-μm-diameter particles; Phenomenex). Mobile phase A was composed of 95:5 water:methanol ...
-
bioRxiv - Molecular Biology 2024Quote: ... x 150 um id fused silica (Polymicro Technologies Inc., Phoenix, AZ) Jupiter 5 µm C18 media (Phenomenex, Torrance, CA) with 2 mm sol-gel frits on either end ...
-
bioRxiv - Biochemistry 2024Quote: ... Separation of polar metabolites was conducted on a Luna 5 μm NH2 100 Å LC column (Phenomenex 00B4378-E0) with normal phase chromatography ...
-
bioRxiv - Plant Biology 2024Quote: A methanolic extract of the QC material was diluted 1:1 with H2O + 0.1% FA and semi-purified using a solid phase extraction (SPE; StrataX 33 μM, 30 mg, 3 mL tube; Phenomenex, Torrance, CA, United States) method adapted from Redan and others (Redan et al. ...
-
bioRxiv - Physiology 2024Quote: LC-MS/MS chromatographic separation of bile acids was performed using a reverse phase C8 column (Phenomenex Luna C8, 150 × 2.0 mm, 3 µm) at a flow rate of 0.2 ml/min ...
-
bioRxiv - Developmental Biology 2020Quote: ... and then connected to a 100 μm fused silica microcapillary column packed with 5-μm C18 reverse-phase (Aqua, Phenomenex) (Florens and Washburn ...
-
bioRxiv - Cell Biology 2021Quote: ... self-packed with C-18 reverse-phase resin (Jupiter 5 um particles, 300 Å pore size; Phenomenex, Torrance, CA, USA) using a high- pressure packing cell on the Easy-nLC II system (Proxeon Biosystems ...
-
bioRxiv - Plant Biology 2021Quote: ... The appearance of the product pABAGlu was measured using Orbitrap-Exactive LC-MS in a reversed-phase Luna C18 column (5 μm particle size, 250 mm x 4.60 mm ID) (Phenomenex, USA) using gradient elution program ...
-
bioRxiv - Biochemistry 2020Quote: ... on a Agilent Technologies (GC-6890N, MS detector-5973) with a ZB-5 column (30 M x 25 mm x 25 mm, Phenomenex), with a temperature program of at 70 °C for 10 min followed by a gradient to 220°C at 5°C /min and held at 220°C for a further 15 min ...
-
bioRxiv - Microbiology 2020Quote: ... For HPLC-MS analysis 7 μl of the sample supernatant was injected into a Gemini C18 column (150 by 4.6 mm, 5 μm, 110 Å, Phenomenex). A 45 min program at a flow rate of 0.2 ml/min was used to separate the compounds as previously described (55) ...
-
bioRxiv - Cell Biology 2020Quote: ... Peptide mixtures were loaded onto 100 µm fused silica microcapillary columns packed with 5-μm C18 reverse phase (Aqua, Phenomenex), strong cation exchange particles (Partisphere SCX ...
-
bioRxiv - Biochemistry 2020Quote: ... samples containing 100 ng recombinant protein were run over a 5 μm Jupiter C4 300Å LC column (Phenomenex, Torrance, California) using the 1260 Infinity LC system (Agilent Technologies ...
-
bioRxiv - Biochemistry 2021Quote: ... The peptide was introduced to a prep RP-HPLC column (C18 Axia, 22 mm x 250 mm, 5 micron particle, size 110 angstrom pore size, Phenomenex). The linear sequence was eluted from the column by running a gradient between solvents A and B ...
-
bioRxiv - Molecular Biology 2020Quote: ... Peptides were suspended in 0.1% formic acid and injected in an in-house made 5 cm reversed phase pre-column (inner diameter 100 µm, filled with a 10 µm C18 Jupiter resins-Phenomenex) coupled to a nano-HPLC (NanoLC-1DPlus ...
-
bioRxiv - Molecular Biology 2020Quote: ... The peptide fractionation was carried out on an in-house 10 cm reversed phase capillary emitter column (inner diameter 75 µm, filled with 5 µm C18 Aqua resins-Phenomenex) with a gradient of 2-35 % of acetonitrile in 0.1% formic acid for 52 min followed by a gradient of 35-95% for 5 min at a flow rate of 300 ml/min ...
-
bioRxiv - Biochemistry 2021Quote: ... The samples were eluted on a C-18 Omega Polar HPLC column (Phenomenex, 250 × 4.6 mm, 5 mm particle size) using 50:50 acetonitrile:H2O for 3 min ...
-
bioRxiv - Microbiology 2020Quote: ... reversed-phase chromatography was performed with a Luna 5 mm C5 100 Å LC column (Phenomenex cat # 00B-4043-E0). Samples were injected at 20 ul each ...
-
bioRxiv - Systems Biology 2021Quote: In-house assembled nanoPOTS autosampler with an in-house packed SPE column (100 μm i.d., 4 cm, 5 μm, 300 Å C18 material, Phenomenex) and an LC column (50 μm i.d. ...
-
bioRxiv - Cancer Biology 2020Quote: ... a ZebronTM ZB-624 column (30 m x 0.32 mm x 1.80 mm, 5% cyanopropylphenyl-94% dimethylpolysiloxane, Phenomenex, Torrance, CA) was used ...
-
bioRxiv - Cell Biology 2021Quote: ... and then connected to a 100 μm fused silica microcapillary column packed with 5-μm C18 reverse phase (Aqua, Phenomenex)62 ...
-
bioRxiv - Microbiology 2021Quote: ... Reversed-phase chromatography was performed with a Luna 5 mm C5 100 Å LC column (Phenomenex cat #00B-4043-E0). Samples were injected at 20 ul each ...