Labshake search
Citations for Gatan :
301 - 350 of 419 citations for Stereo Zoom microscope since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2019Quote: Data was collected on a Talos Arctica transmission electron microscope (FEI Company) operating at 200 keV with a K2 Summit direct electron detector (Gatan Inc). Dose-fractionated movies were collected in counting mode ...
-
bioRxiv - Cell Biology 2019Quote: ... Serial sections containing cells/regions of interest were then transferred to a Tecnai F30 transmission electron microscope (ThermoFischer Scientific, USA) operated at 300 kV and equipped with a US1000 CCD camera (Gatan, USA). Tilt series were acquired from −65° to +65° with 1° increments at a magnification of 4700x ...
-
bioRxiv - Neuroscience 2021Quote: ... TEM imaging was performed in high contrast mode with a H7650 transmission electron microscope (Hitachi) equipped with an Orius SC1000 CCD camera 0(Gatan Inc).
-
bioRxiv - Biophysics 2021Quote: ... transmission electron microscope operating at 300 kV equipped with a Gatan Quantum-LS energy filter (slit width 20 eV; Gatan Inc.) and a K2 Summit direct electron detector (Gatan Inc.) ...
-
bioRxiv - Biophysics 2020Quote: Samples of tubular crystals were imaged with a Talos Arctica 200 kV electron microscope (FEI Corp) with a K2 Summit detector (Gatan Inc) and samples of the YiiP/Fab complex were imaged with a Titan Krios G3i ...
-
bioRxiv - Biophysics 2020Quote: Images were recorded using FEI Titan Krios microscope operating at 300 kV with a Gatan K3 Summit direct electron detector (Gatan Inc.) at Tsinghua University ...
-
bioRxiv - Biophysics 2019Quote: ... Data for the FLN5-45 and FLN5-47 RNC complexes were automatically collected on a Titan Krios electron microscope (FEI) operating at 300 kV and equipped with K2 Summit direct electron detector (Gatan Inc.) at the eBIC Diamond light source facility (Harwell Campus ...
-
bioRxiv - Biochemistry 2022Quote: ... Cryo-EM datasets were collected using SerialEM and EPU in different microscopes all equipped with Field Emission source and K3 camera (Gatan Inc.) operated by SLAC national facility.
-
bioRxiv - Cell Biology 2022Quote: ... TEM images were collected with a JEOL JEM 1011 electron microscope and recorded with a 2 Mp charge coupled device camera (Gatan Orius).
-
bioRxiv - Biochemistry 2019Quote: ... Cryo-EM datasets were collected using SerialEM in three different microscopes all equipped with Field Emission source and K2 or K3 camera (Gatan Inc.) operated in super-resolution mode (Supplementary Table 2).
-
bioRxiv - Microbiology 2020Quote: ... Consecutive sections were viewed using a 120 kV Tecnai G2 Spirit transmission electron microscope (Thermo Fischer Scientific) and images were captured using an Orius CCD camera (Gatan Inc). Individual TEM images of ~25-30 consecutive sections per Tg parasite were converted as Tiff in Digital Micrograph (Gatan Inc. ...
-
bioRxiv - Biochemistry 2021Quote: ... The data was collected using a 300-kV transmission electron microscope (Titan Krios, TFS) on a direct electron detector (Gatan K3). Data collection parameters are in Supplementary Table 1.
-
bioRxiv - Biochemistry 2021Quote: ... Data were recorded on a FEI Titan Krios microscope operated at 300 kV equipped with a K2 Summit direct electron detector (Gatan Inc.) and Quantum-LS energy filter (slit width 20 eV ...
-
bioRxiv - Biochemistry 2021Quote: Tilt series were collected at the eBIC National facility using a Titan Krios microscope operated at 300 keV with a post-GIF K2 Summit direct electron detector (Gatan, USA) operating in counting mode ...
-
bioRxiv - Immunology 2020Quote: ... Micrographs were recorded on a Thermo Fisher Talos Arctica transmission electron microscope operating at 200 keV using a K3 direct electron detector (Gatan, Inc) and SerialEM automated image acquisition software38 ...
-
bioRxiv - Molecular Biology 2021Quote: Treated and untreated ICP1-containing grids were clipped and loaded into a Titan Krios (TFS) microscope equipped with a K3 BioQuantum direct electron detector and energy filter (Gatan, Inc) set to 20eV ...
-
bioRxiv - Cell Biology 2021Quote: ... datasets were collected using Leginon49 on a ThermoFisher Glacios transmission electron microscope operating at 200keV equipped with a Gatan K2 Summit direct electron detector (Gatan Inc.) in counting mode ...
-
bioRxiv - Neuroscience 2022Quote: ... after adsorption onto carbon-coated 200 mesh grids and negative staining with 1% uranyl acetate using a Jeol 1400 transmission electron microscope and the images were recorded with a Gatan Orius CCD camera (Gatan, Pleasanton).
-
bioRxiv - Molecular Biology 2023Quote: ... Images were obtained using a transmission electron microscope (Thermo Fisher Tecnai T12 TEM, operated at 120kV, using a Gatan OneView camera). Analysis and measurements were made using Gatan DigitalMicrograph and ImageJ software.
-
bioRxiv - Molecular Biology 2023Quote: ... Wild type apo and LMHS apo were acquired on a FEI Titan Krios electron microscope operating at 300kV equipped with Gatan Bioquantum Image filter-K3 direct electron detector (Gatan Inc) at 20eV energy slit ...
-
bioRxiv - Biochemistry 2023Quote: ... CryoEM movies were acquired on a TFS Glacios microscope operating at 200 kV and equipped with Gatan K3 direct electron detector (Gatan Inc.). Images were collected automatically with SerialEM software in counting mode at a nominal magnification of 46,000x and pixel size of 0.878 Å over a defocus range of 0.5-2.5 µm ...
-
bioRxiv - Bioengineering 2023Quote: ... TEM images were collected with a JEOL JEM 1011 electron microscope and recorded with a 2 Mp charge coupled device camera (Gatan Orius).
-
bioRxiv - Biochemistry 2023Quote: ... The specimen was visualized using a Titan Krios electron microscope (FEI) operating at 300 kV and equipped with a K3 direct electron detector (Gatan, Inc). Images were recorded with a nominal magnification of 81,000x in super-resolution counting mode ...
-
bioRxiv - Cancer Biology 2023Quote: ... Following this the grid was blotted and allowed to air dry before imaging on a FEI Tecnai T12 transmission electron microscope (FEI UK Ltd) operated at 120 kV with a Gatan Oneview digital camcer (Gatan Inc) at 120,000X magnification.
-
bioRxiv - Neuroscience 2024Quote: ... super-resolution movies were collected on Titan Krios microscope operating at 300 kV equipped with K3 direct electron detector and BioQuantum (Gatan Inc.) energy filter with a slit width of 20 eV ...
-
bioRxiv - Biochemistry 2024Quote: ... The specimen was visualized at the National Cryo-EM Facility using a Titan Krios electron microscope (FEI) operating at 300 kV and equipped with a K3 direct electron detector (Gatan, Inc.) with the Latitude software (Gatan ...
-
bioRxiv - Biophysics 2024Quote: ... Grids were initially screened on an FEI Tecnai T20 transmission electron microscope operated at a voltage of 200 kV with a direct electron detector K2 Summit (Gatan Inc.) using SerialEM 73.
-
bioRxiv - Molecular Biology 2023Quote: Subsequent electron tomography was performed on a 300 keV electron microscope (G3 Titan KriosTM) equipped with direct electron detection camera with a BioQuantumTM Imaging Filter (Gatan, Inc) using a 20-eV slit width ...
-
bioRxiv - Molecular Biology 2023Quote: ... crescentus were acquired using a 300 keV electron microscope (G3 Titan KriosTM) equipped with direct electron detection camera with a BioQuantumTM Imaging Filter (Gatan, Inc) using a 30-eV slit width ...
-
bioRxiv - Molecular Biology 2020Quote: ... triplicate datasets per condition were collected manually on a FEI Spirit T12 microscope (equipped with Gatan 2K Œ 2K CCD (model 984) operated at 120 kV with a 1-1.5 second exposure and a pixel size of 3.64-3.5 Å/pix ...
-
bioRxiv - Cell Biology 2019Quote: ... ultrastructural images were produced on a Qanta FEG 250 scanning electron microscope (FEI, Eindhoven, The Netherlands) equipped with a 3View2XP serial block face module (Gatan, Munich, Germany) using the Digital Micrograph program (Gatan) ...
-
bioRxiv - Cell Biology 2019Quote: ... from the imaged cells were cut and post-stained with uranyl acetate/lead citrate and imaged in a Tecnai 12 electron microscope (FEI, Hillsboro, OR) operating at 80kV equipped with an Ultrascan 4000 digital camera (Gatan Inc, CA).
-
bioRxiv - Biochemistry 2021Quote: ... electron microscope operating at 300 kV with a K2 or K3 direct electron detector equipped with a Bioquantum energy filter (Gatan, Pleasonton USA). The slit width of the energy filter was set to 20 eV ...
-
bioRxiv - Microbiology 2021Quote: ... specimens were subjected to imaging at -170°C using a Polara G2 electron microscope (FEI Company) equipped with a field emission gun and a direct detection device (Gatan K2 Summit). The microscope was operated at 300 kV at a magnification of 15K ...
-
bioRxiv - Biochemistry 2021Quote: Data was collected on an FEI Titan Krios cryo-electron microscope equipped with a K3 Summit direct electron detector (Gatan, Pleasanton, CA). Images were recorded with SerialEM50 with a pixel size of 1.1Å over a defocus range of −1.5 to −2.5 μm ...
-
bioRxiv - Biochemistry 2021Quote: Data acquisition was performed on a 300 keV Titan Krios microscope equipped with a Gatan K3 direct detector (Gatan, U. S. A.) in the super-resolution mode using EPU software (ThermoFisher Scientific ...
-
bioRxiv - Biochemistry 2020Quote: Data was collected on an FEI Titan Krios cryo-electron microscope equipped with a K3 Summit direct electron detector (Gatan, Pleasanton, CA). Images were recorded with SerialEM (Mastronarde ...
-
bioRxiv - Biophysics 2021Quote: The dataset of catalase was collected in an FEI Titan Krios G2 electron microscope (300 kV) equipped with an energy filter and direct electron detector (Gatan BioQuantum K2) operated at the super resolution mode (Extended Data Table 1) ...
-
bioRxiv - Biophysics 2021Quote: ... 1.7 Å pixel size) in an FEI Talos Arctica electron microscope (200 kV) equipped with an energy filter and direct electron detector (Gatan BioQuantum K2). For each tilt ...
-
bioRxiv - Biophysics 2021Quote: The dataset of aldolase was collected in an FEI Titan Krios G2 electron microscope (300 kV) equipped with an energy filter and direct electron detector (Gatan BioQuantum K2) operated at the super resolution mode (Extended Data Table 1) ...
-
bioRxiv - Biophysics 2021Quote: The dataset of GDH was collected in an FEI Titan Krios G2 electron microscope (300 kV) equipped with an energy filter and direct electron detector (Gatan BioQuantum K2) operated at the super resolution mode (Extended Data Table 1) ...
-
bioRxiv - Biophysics 2021Quote: The cryo-EM dataset of apoferritin was collected in an FEI Talos Arctica electron microscope (200 kV) equipped with an energy filter and direct electron detector (Gatan BioQuantum K2) operated at the super resolution mode (Extended Data Table 1) ...
-
bioRxiv - Biophysics 2021Quote: The dataset of human hemoglobin was collected in an FEI Talos Arctica electron microscope (200 kV) equipped with an energy filter and direct electron detector (Gatan BioQuantum K2) operated at the super resolution mode (Extended Data Table 1) ...
-
bioRxiv - Neuroscience 2019Quote: ... Samples were imaged at cryo temperatures under standard low-dose conditions on either a FEI Tecnai Spirit electron microscope (120 kV, 23000x) equipped with a Gatan Ultrascan 4000 CCD camera (4.9 Å/pixel, Gatan, Pleasanton CA) or on a FEI Tecnai Polara electron microscope (300 kV ...
-
bioRxiv - Microbiology 2021Quote: ... The specimen were imaged on a Thermo Fisher Scientific Titan Krios electron microscope operating at 300 kV with a K3 camera (Gatan, Pleasanton, USA) and a Gatan energy filter at a slit width of 20 eV ...
-
bioRxiv - Neuroscience 2019Quote: Stained grids were examined under a Philips CM-12 electron microscope (FEI; Eindhoven, The Netherlands) and photographed with a Gatan (4k x 2.7k) digital camera (Gatan, Inc., Pleasanton, CA). Samples were imaged at a series of increasing magnifications (i.e. ...
-
bioRxiv - Cell Biology 2021Quote: ... Sections were contrast stained with lead citrate and photographed in a Jeol 100S transmission electron microscope (Jeol Europe) fitted with an Orius SC200 digital camera (Gatan-Roper Scientific).
-
bioRxiv - Biochemistry 2022Quote: ... Data were collected using a FEI Titan Krios cryo-electron microscope equipped with a K3 Summit direct electron detector (Gatan, Pleasanton, CA). Images were recorded with SerialEM42 with a pixel size of 0.81 Å ...
-
bioRxiv - Plant Biology 2022Quote: ... Samples were examined using the FEI Tecnai G2 Spirit transmission electron microscope with two digital CCD cameras (Gatan Orius 1000, FEI Eagle).
-
bioRxiv - Cell Biology 2020Quote: ... and imaged using an FEI Morgagni transmission electron microscope (FEI, Hillsboro, OR) operating at 80 kV and equipped with a 1k × 1k charge coupled device (CCD) camera (Gatan, Pleasanton, CA).