Labshake search
Citations for Gatan :
101 - 150 of 170 citations for 8 11 Methano 10a 3 6a 1 propanyl 3 ylidene 8H indeno 2 1 b azocine 12 14 dione 5 acetyloxy 4 benzoyloxy dodecahydro 1 3 dimethyl 9 methylene 3R 4S 5R 6aR 6bR 8S 10aR 11R 11aS 15S 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... UltraAuFoil 1.2/1.3 300 mesh grids were plasma cleaned for 12 sec in a pre-set program using a Solarus II plasma cleaner (Gatan). 3.5 µl protein was applied to the grids in the environmental chamber of a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... The grids were examined at 120kV with TEM (Tecnai 12, Thermo Fischer Scientific) equipped with a 4K CDD camera (Oneview, Gatan).
-
bioRxiv - Microbiology 2023Quote: ... The sample was imaged at a magnification range of 12 and 50kX with the Oneview 16-Megapixel camera (Gatan®).
-
bioRxiv - Biochemistry 2024Quote: ... Quantifoil copper 1.2/1.3 300 mesh grids were plasma cleaned for 12 seconds using a preset program in the Solarus II plasma cleaner (Gatan). The AriAEQ protein sample was applied to the grid in a 3.5 μL drop within the environmental chamber adjusted to 4°C temperature and approximately 95% humidity in a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: ... UltrAuFoil 1.2/1.3 300 mesh grids were plasma cleaned for 12 seconds using a preset program in the Solarus II plasma cleaner (Gatan). The AriAEQ-AriBE90A complex sample was applied to the grid in a 3 μL drop within the environmental chamber adjusted to 4°C temperature and approximately 95% humidity in a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: ... UltrAuFoil 1.2/1.3 300 mesh grids were plasma cleaned for 12 seconds using a preset program in the Solarus II plasma cleaner (Gatan). Immediately prior to freezing samples ...
-
bioRxiv - Molecular Biology 2022Quote: 3 μL of 0.8-1.0 mg/ml purified ME3 with/without Citrate or NADP complex was applied to the plasma-cleaned (Gatan Solarus) Quantifoil 1.2/1.3 UltraAuFoil holey gold grid ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μL of protein was deposited on an UltrAuFoil 1.2/1.3 grid that was plasma cleaned at 25 mA for 2 minutes using a Solarus plasma cleaner (Gatan). Excess liquid was blotted away for 3 seconds in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2020Quote: ... 3.5 µl EfPiwi-guide complex at 2.5 mg/ml with or without target RNA was added onto freshly plasma cleaned (75% nitrogen, 25% oxygen atmosphere at 15 W for 7 seconds in Solarus plasma cleaner, Gatan) 300 mesh holey gold grids (UltrAuFoil R1.2/1.3 ...
-
bioRxiv - Biophysics 2022Quote: ... Cryo-EM grids with optimal particle distribution and ice thickness were obtained by varying the gas source (air using PELCO easiGlow™, target vacuum of 0.37 mbar, target current of 15 mA; or H2/O2 using Gatan Model 950 advanced plasma system ...
-
bioRxiv - Microbiology 2020Quote: ... The sections were imaged using a Tecnai 12 TEM at 120 KV (FEI) and images were collected using UltraScan 1000 digital micrograph software (Gatan Inc.).
-
bioRxiv - Cell Biology 2022Quote: ... Grids were air-dried and examined at 120kV by an FEI Tecnai 12 TEM equipped with an Ultrascan 1000 CCD camera (Gatan, Inc).
-
bioRxiv - Immunology 2022Quote: ... The sections were imaged using an FEI Tecnai 12 120kV TEM (FEI) and data recorded using a Gatan Rio16 CMOS camera with GWS software (Gatan Inc.).
-
bioRxiv - Biochemistry 2022Quote: ... was applied to C-flat holey carbon grids (2/2, 400 mesh) which had been plasma cleaned for 30 seconds in a Solarus 950 plasma cleaner (Gatan) with a 4:1 ratio of O2/H2 ...
-
bioRxiv - Plant Biology 2022Quote: ... Movies were automatically recorded by SerialEM using image shift (5×5 holes per stage position) and a K3 Direct Detection Camera (Gatan, AMETEK, Pleasanton, CA, USA) in CDS mode at a nominal magnification of 60,000× at the camera level ...
-
bioRxiv - Biophysics 2021Quote: ... that had been freshly plasma cleaned for 7 seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere) using a Solarus plasma cleaner (Gatan, Inc.). Grids were manually blotted using Whatman No ...
-
bioRxiv - Biophysics 2021Quote: ... that had been freshly plasma cleaned for 6 seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere) using a Solarus plasma cleaner (Gatan, Inc.). Grids were manually blotted using Whatman No ...
-
bioRxiv - Biophysics 2021Quote: ... Grids (Copper 200 or 300 mesh coated with continuous ultrathin carbon) were plasma cleaned using an H2/O2 gas mixture for 15 s in a Solarus II plasma cleaner (Gatan Inc.) or 10 s in a PELCO easiGlow glow discharge cleaning system (Ted Pella Inc.) ...
-
bioRxiv - Biophysics 2021Quote: ... Grids were plasma cleaned using an H2/O2 gas mixture for 15 s in a Solarus II Plasma Cleaner (Gatan Inc.) before 1.8 μL of protein suspension was applied to the surface of the grid ...
-
bioRxiv - Molecular Biology 2019Quote: ... that had been previously plasma cleaned in a 75% argon / 25% oxygen atmosphere at 15 Watts for 6 seconds using a Solarus plasma cleaner (Gatan, Inc). The grids were loaded into a Vitrobot (ThermoFisher ...
-
bioRxiv - Biophysics 2024Quote: ... Grids were plasma cleaned for six seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere) using a Solarus plasma cleaner (Gatan, Inc.) immediately prior to sample preparation ...
-
bioRxiv - Cell Biology 2019Quote: ... from the imaged cells were cut and post-stained with uranyl acetate/lead citrate and imaged in a Tecnai 12 electron microscope (FEI, Hillsboro, OR) operating at 80kV equipped with an Ultrascan 4000 digital camera (Gatan Inc, CA).
-
bioRxiv - Neuroscience 2019Quote: Stained grids were examined under a Philips CM-12 electron microscope (FEI; Eindhoven, The Netherlands) and photographed with a Gatan (4k x 2.7k) digital camera (Gatan, Inc., Pleasanton, CA). Samples were imaged at a series of increasing magnifications (i.e. ...
-
bioRxiv - Molecular Biology 2020Quote: ... Grids were imaged using a FEI Tecnai 12 TEM at 120 kV using a Gatan OneView CMOS camera (Gatan, Pleasanton, CA, USA).
-
bioRxiv - Physiology 2019Quote: ... Images were obtained with a Phillips Technai-12 electron microscope (FEI, Hillsboro, OR) and 794 Gatan multiscan CCD camera (Gatan, Pleasanton, CA) using Digital Micrograph software ...
-
bioRxiv - Cell Biology 2019Quote: ... Electron microscopy was carried out using a Philips CM-12 electron microscope (FEI; Eindhoven, The Netherlands) and images photographed with using a Gatan (4K × 2.7K) digital camera (Gatan, Inc., Pleasanton, CA).
-
bioRxiv - Cell Biology 2022Quote: ... Grids were imaged using a FEI Tecnai 12 TEM at 120 kV using a Gatan OneView CMOS camera (Gatan, Pleasanton, CA, USA).
-
bioRxiv - Cell Biology 2023Quote: ... Stained grids were examined under Philips CM-12 electron microscope and photographed with a Gatan (4k ×2.7k) digital camera (Gatan, Inc., Pleasanton, CA).
-
bioRxiv - Molecular Biology 2021Quote: ... The samples were analyzed in a Philips CM 12 transmission electron microscope (Eindhoven, the Netherlands) equipped with a charge-coupled device (CCD) camera (Ultrascan 1000, Gatan, Pleasanton, CA, USA) at an acceleration voltage of 100 kV.
-
bioRxiv - Immunology 2020Quote: ... Images were acquired under low dose conditions (<30 e−/Å2) on a Tecnai 12 FEI electron microscope operated at 120 kV using a Gatan ORIUS SC1000 camera (Gatan, Inc., Pleasanton, CA) at 30,000x nominal magnification ...
-
bioRxiv - Neuroscience 2023Quote: ... Sections were examined and photographed using a Tecnai G2 12 transmission electron microscope (Fei Company, Hillsboro, OR) equipped with a digital micrograph OneView camera (Gatan Inc., Pleasanton, CA).
-
bioRxiv - Microbiology 2024Quote: ... and analyzed in a Philips CM 12 transmission electron microscope (Eindhoven, the Netherlands) equipped with a charge-coupled device (CCD) camera (Ultra-scan 1000, Gatan, Pleasanton, CA, USA) at an acceleration voltage of 100 kV.
-
bioRxiv - Plant Biology 2023Quote: ... Images were collected digitally with a 2×2K Ultrascan1000 CCD (Gatan).
-
bioRxiv - Microbiology 2022Quote: ... and photographed using a Gatan OneView digital camera with 4×4k resolution (Gatan, Pleasanton, CA). Micrographs were randomly taken from 3 mice per group (8 to 10 photographs per mouse with a total of 25 to 28 photographs ...
-
bioRxiv - Physiology 2021Quote: ... and photographed using a Gatan OneView digital camera with 4×4k resolution (Gatan, Pleasanton, CA). Morphometric analyses of the dense core vesicles were determined as described 86 ...
-
bioRxiv - Immunology 2021Quote: ... and photographed using a Gatan OneView digital camera with 4×4k resolution (Gatan, Pleasanton, CA).
-
bioRxiv - Biochemistry 2021Quote: ... 4 µL of sample were added to a continuous carbon grid after glow discharge (Solarus, Gatan). After 1 minute incubation ...
-
bioRxiv - Biochemistry 2022Quote: ... 4 images per hole with defocus range of −0.5 - −2.5 μm were collected with K3 detector (Gatan) operated in super resolution mode ...
-
bioRxiv - Biochemistry 2022Quote: ... 4 images per hole with defocus range of −0.5 - −2.5 μm were collected with K3 detector (Gatan) operated in super resolution mode ...
-
bioRxiv - Biophysics 2024Quote: ... 4 μl of the specimen was applied to a freshly plasma cleaned (Gatan Solarus, H2 / O2 mixture) C-flat 1.2/1.3 holey carbon Au 300 mesh grid (Electron Microscopy Sciences ...
-
bioRxiv - Immunology 2020Quote: ... the complex was deposited on Au-300 1.2/1.3 grids that had been plasma cleaned for 4 minutes in a Solarus 950 plasma cleaner (Gatan) with a 4:1 ratio of O2/H2 ...
-
bioRxiv - Immunology 2021Quote: ... The complex was deposited on Au-300 1.2/1.3 grids that had been plasma cleaned for 4 minutes in a Solarus 950 plasma cleaner (Gatan) with a 4:1 ratio of O2/H2 ...
-
bioRxiv - Biophysics 2021Quote: ... the samples were sputtered with a layer of 5-6-nm platinum (coater: Model 681; Gatan, USA).
-
bioRxiv - Biochemistry 2023Quote: ... 1063 movies (40 frames /movie; 5 s exposure) were collected using a Quantum K2 LS detector (Gatan) at a magnification of 165.000x ...
-
bioRxiv - Biochemistry 2023Quote: ... Grids were glow discharged for 25 s at 50 W (UltrAuFoil R1.2/1.3) or 10 s at 5 W (Lacey) with a Solarus II plasma cleaner (Gatan). Vitrification was carried out using a Vitrobot Mark IV (ThermoScientific) ...
-
bioRxiv - Biochemistry 2023Quote: The 20bp dataset was collected on a FEI Glacios cryo-EM microscope (200kV) equipped with a Falcon 4 direct electron detector (Gatan). Movies were recorded in SerialEM44 with a pixel size of 0.94Å and a total exposure time of 15 sec resulting in an accumulated dosage and 49e-/Å2 split into 60 frames ...
-
bioRxiv - Biochemistry 2021Quote: Images of the sample without Apg2 (Supplementary Figure 4) were acquired at the Electron Bio-Imaging Centre (eBIC) at Diamond on a post-GIF K3 detector (Gatan, USA) operating in super resolution counting mode using a Titan Krios microscope (Thermo Fisher ...
-
bioRxiv - Immunology 2020Quote: ... which had been plasma-cleaned for 5 seconds using a mixture of Ar/O2 (Gatan Solarus 950 Plasma system). For the BG505 SOSIP-T33_dn2 nanoparticle sample ...
-
bioRxiv - Immunology 2020Quote: ... which had been plasma-cleaned for 5 seconds using a mixture of N2/O2 (Gatan Solarus 950 Plasma system). The grid was blotted and plunged into liquid Ethane using a Vitrobot Mark IV (ThermoFisher).
-
bioRxiv - Immunology 2020Quote: ... which had been plasma-cleaned for 5 seconds using a mixture of N2/O2 (Gatan Solarus 950 Plasma system). The grid was blotted and plunged into liquid Ethane using a Vitrobot Mark IV (ThermoFisher) ...