Labshake search
Citations for Leica :
301 - 350 of 760 citations for Galactose Colorimetric Detection Kit 2 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2019Quote: ... The labtek plates were mounted on an inverted confocal laser scanning microscope (Leica SP8X) and imaged using a 10X objective ...
-
Paracrine signalling between intestinal epithelial and tumour cells induces a regenerative programmebioRxiv - Cancer Biology 2021Quote: ... Whole plate acquisition was performed using a dissecting microscope and Cell Discoverer 7 (Leica). Images were captured with ZEN ...
-
bioRxiv - Microbiology 2024Quote: ... crystallization plates were stored at 20°C and inspected with a stereo microscope (Leica) to monitor crystal growth.
-
bioRxiv - Cancer Biology 2021Quote: ... The double staining was done sequentially on a Leica Bond-IIITM instrument using the Bond Polymer Refine DAB Detection System (Leica Microsystems DS9800, Buffalo Grove, IL) and Refine Red Detection System (Leica Microsystems DS9390) ...
-
bioRxiv - Neuroscience 2020Quote: ... which shows expression in uninjured axons.25 All immunostains were performed using a Leica Bond III automated immunostainer with a diaminobenzidine chromogen detection system (DS9800, Leica Biosystems, Buffalo Grove, IL, USA).
-
bioRxiv - Cancer Biology 2021Quote: ... Optimal primary antibody stripping conditions between rounds in the seven-color assay were performed following 1 cycle of tyramide deposition followed by heat-induced stripping (see below) and subsequent chromogenic development (Leica Bond Polymer Regine Detection DS9800) with visual inspection for chromogenic product with a light microscope by a senior pathologist (T.J.H.) ...
-
bioRxiv - Pathology 2022Quote: ... and incubated with a 1:200 dilution of anti-4-HNE and anti-AKR1A1 primary antibody overnight at 4°C primary antibody along with the Novolink™ Max Polymer Detection System (Leica Biosystems, Wetzlar, Hesse, Germany) and DAB substrate (3,30-diaminobenzidine ...
-
bioRxiv - Cancer Biology 2023Quote: ... Optimal primary antibody stripping conditions between rounds in the seven-color assay were performed following 1 cycle of tyramide deposition followed by heat-induced stripping (see below) and subsequent chromogenic development (Leica Bond Polymer Regine Detection DS9800) with visual inspection for chromogenic product with a light microscope (TH) ...
-
bioRxiv - Cancer Biology 2021Quote: ... After heat-induced epitope retrieval (HIER) at 100°C (BOND Epitope Retrieval Solution 1 or 2, Leica, Germany; HIER 1 AR9961, HIER 2 AR9640), endogenous peroxidase activity was blocked by incubation with 3% peroxide block for 20 minutes (BOND Polymer Refine Detection System ...
-
bioRxiv - Neuroscience 2020Quote: ... and 2 CaCl2) using a vibratome (Vibracut, Leica Biosystems, Germany) followed by incubation in carbogenized aCSF for 30 min at 36°C and then kept at room temperature (~21° C ...
-
bioRxiv - Plant Biology 2021Quote: ... An upright confocal laser scanning microscope (TCS SP5 2; Leica) using a 40x apochromatic water immersion lens was used to visualized YFP fluorescence (excitation ...
-
bioRxiv - Microbiology 2021Quote: ... and 2% water with an AFS (Leica microsystems, Vienna, Austria). After bringing the cells to RT they were washed in acetone and gradually infiltrated with epoxy resin (Agar Scientific ...
-
bioRxiv - Developmental Biology 2021Quote: ... 2 mm sections were obtained using a vibratome (Leica, VT1200S) and immobilized using glue in a polystyrene-bottom dish (TPP ...
-
bioRxiv - Biophysics 2023Quote: ... 2 mm sections were obtained using a vibratome (Leica, VT1200S) and immobilized using tissue seal (histoacryl blue ...
-
bioRxiv - Bioengineering 2022Quote: ... These blocks were glued onto the sample plate of the microtome (Leica Microsystems, Mannheim, Germany), covered with PBS ...
-
bioRxiv - Microbiology 2022Quote: ... covered with the flat side of a 3-mm type B aluminum plate (Leica Microsystems) and vitrified by high-pressure freezing in a HPM100 system (Leica Microsystems) ...
-
bioRxiv - Cell Biology 2023Quote: ... Plates were maintained in the incubator chamber of a confocal TCS SP5 microscope (Leica Microsystems) under controlled conditions (34 °C ...
-
bioRxiv - Plant Biology 2023Quote: ... germinated on plates and manually screened for fluorescent transformants on a stereomicroscope (Leica M165 FC) equipped with a GFP filter allowing for 470 ± 20 nm excitation and emission at 525 ± 25 nm.
-
bioRxiv - Cancer Biology 2023Quote: Cells were imaged on 96-well plates using motorized Leica DMI8 fluorescence microscope (Leica, Germany). For nuclei staining 1 μg/ml Hoechst-33342 was added ...
-
bioRxiv - Cancer Biology 2023Quote: ... Plates were centrifuged and all wells were examined in a light microscope (Leica, Wetzlar, Germany) to identify wells containing single cells ...
-
bioRxiv - Microbiology 2021Quote: ... plates were screened for double-positive mCherry and EGFP expressing plaques using an inverted microscope (Leica DMi8 automated ...
-
bioRxiv - Neuroscience 2021Quote: ... The unseeded plates were imaged under RFP fluorescence optics on a stereo fluorescence microscope (Leica M165FC). We briefly recorded images of the worms at approximately 60X magnification to confirm that the targeted nerve cords were lesioned ...
-
bioRxiv - Cancer Biology 2022Quote: ... The 12-well cell plate was also imaged with EVOS® FL Auto Imaging System (Leica) to image the stained lipid droplets at 10x or 20x magnification.
-
bioRxiv - Molecular Biology 2023Quote: ... Images were captured for each plate using a stereomicroscope Leica MZFLIII (Leica Microsystems GmbH, Mannheim, Germany), set at 8x magnification ...
-
bioRxiv - Neuroscience 2019Quote: ... Pictures were taken with a Leica microscope (Axioscop 2, Leica GmbH).
-
bioRxiv - Microbiology 2021Quote: ... as follows: SARS-CoV-2 Spike protein: 1:1000 (Leica, AR9961) 30minutes ...
-
bioRxiv - Neuroscience 2021Quote: ... Slices were visualized on a resonant scanning 2-photon system (Leica) and Z-stack images were taken ...
-
bioRxiv - Cancer Biology 2020Quote: ... followed by pretreatment with Epitope Retrieval Solution 2 (AR9649, Leica Biosystems) for 20 minutes and then blocking buffer for 10-20 minutes ...
-
bioRxiv - Cancer Biology 2019Quote: ... Panel 2 consisted of primary antibodies against CD3 (clone LN10, Leica), PD-1 (clone NAT105 ...
-
bioRxiv - Immunology 2023Quote: ... Fura-2-AM was excited using a monochromatic light source (Leica) coupled into an inverted Leica DMI4000B microscope that was equipped with a 20x objective (HCX PL Fluotar 20x ...
-
bioRxiv - Cancer Biology 2023Quote: ... anti-BCL2 (Clone: BCL-2/100/D5; RTU; Leica Biosystems; #PA0117), anti-BCL6 (Clone:LN22 ...
-
bioRxiv - Molecular Biology 2023Quote: ... sputter-coated with 2 nm carbon using ACE600 sputter coater (Leica).
-
bioRxiv - Genetics 2019Quote: ... and worms were visually inspected and counted directly in the plate using a dissection stereomicroscope (Leica S6E) and a common cell counter ...
-
bioRxiv - Genetics 2020Quote: ... transitions were monitored in animals on agar plates using brightfield microscopy with an MZ9S stereo microscope (Leica). The fraction of the population that had undergone a developmental transition was estimated by counting worms before or after the transition ...
-
bioRxiv - Microbiology 2022Quote: ... The plates were read with the aid of a computerized image analysis system (Quantimet 500 Qwin; Leica), which measures the diameter of the colonies relative to the precipitation zones on a magnified scale ...
-
bioRxiv - Bioengineering 2024Quote: ... five plates were imaged using brightfield imaging on the Leica THUNDER Imager using the 10X objective (Leica). Images were then sorted into four groups ...
-
bioRxiv - Cell Biology 2024Quote: ... Agar plates were transferred to a Leica TCS SP8 confocal laser–scanning microscope (Leica Microsystems, Wetzlar, Germany) for fluorophore injection ...
-
bioRxiv - Cancer Biology 2019Quote: ... the TMA slide was subjected to Epitope Retrieval Solution 2 (ER2, Leica) antigen retrieval and stained with a prediluted anti-Ki-67 antibody (Mouse ...
-
bioRxiv - Zoology 2020Quote: ... We obtained 2 μm sections in rotating microtome (RM 2265, Leica, Switzerland), which were stained with hematoxylin and eosin.
-
bioRxiv - Cell Biology 2021Quote: ... Samples were stained in 2% aqueous uranyl acetate and lead citrate (Leica) and imaged on a Hitachi HT7800 transmission electron microscope ...
-
bioRxiv - Pathology 2020Quote: ... Epitope retrieval was performed using Epitope Retrieval solution 2 (Leica Biosystems, Germany) for 20 min ...
-
bioRxiv - Immunology 2021Quote: ... Tubes were loaded into an AFS-2 freeze-substitution machine (Leica Microsystems) and processed at −90°C for 72 h ...
-
bioRxiv - Pathology 2021Quote: ... and ddH2O (2 washes) with a Leica ST4020 Linear Stainer (Leica Biosystems). Tissues next underwent antigen retrieval by submerging slides in 3-in-1 Target Retrieval Solution (pH 9 ...
-
bioRxiv - Microbiology 2023Quote: ... and 2% lead-citrate solution (Leica Ultrostain II, Leica Microsystems, Wetzlar, Germany) for 10 min each ...
-
bioRxiv - Developmental Biology 2023Quote: Worms (young adults) were fixed by HPF with EMPACT-2 (Leica Microsystems) and then freeze substituted in anhydrous acetone containing 1% OsO4 ...
-
bioRxiv - Cell Biology 2023Quote: ... Tubes were loaded into an AFS-2 freeze-substitution machine (Leica Microsystems) and processed at -90°C for 72 h ...
-
bioRxiv - Plant Biology 2024Quote: ... Sections (2-µm thick) were cut using a UC7&2265 microtome (Leica). To visualize starch granules and protein bodies ...
-
bioRxiv - Plant Biology 2024Quote: ... and mounted on CryoJane CFSA 1/2 adhesive-coated glass slides (Leica) at the laser microdissection platform from Bordeaux Neurocentre Magendie (https://neurocentre-magendie.fr/) ...
-
bioRxiv - Plant Biology 2023Quote: ... Sections (2-µm thick) were cut using an UC7&2265 microtome (Leica). To visualize starch granules and protein bodies ...
-
bioRxiv - Neuroscience 2024Quote: ... All procedures were carried out using to Angle 2 software (Leica Biosystems) to set and locate coordinates ...