Labshake search
Citations for Leica :
651 - 700 of 747 citations for 3 methy 5 isobutylhydantion since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: ... Slices were imaged with a laser scanning confocal Stellaris 5 or TCS SP8 gSTED equipped with a white light laser and a 405-diode ultraviolet laser (Leica Microscope). Image acquisition was done using the LAS-X software in accordance with the Nyquist sampling sequential mode by exciting the fluorophores and collecting their signal with hybrid detectors (HyDs).
-
bioRxiv - Cancer Biology 2023Quote: ... at a final concentration of 5 µg/mL for 20 minutes at 37 °C prior to live cell imaging by epifluorescence (Leica DMI6000B). Cells were counted as DAPI-positive if the nucleus showed bright staining and as apoptotic if there was characteristic nuclear fragmentation ...
-
bioRxiv - Cancer Biology 2022Quote: ... was incubated at 100 degrees Celsius for 20 minutes (for anti-Cytokeratin 5, Bond Epitope Retrieval 1, pH6.0 (Leica Biosystems, AR9961) was used instead) ...
-
bioRxiv - Biochemistry 2023Quote: ... Cells were placed in a 37°C chamber incubator supplemented with 5% CO2 mounted on Leica TCS SP8X microscope system (Leica Microsystems).
-
bioRxiv - Plant Biology 2023Quote: Lengths of root RAM and EZ regions and root hairs in 5-d-old seedlings grown on vertical MS medium without sucrose were measured under a Leica microscope (Leica DM5000). The data were analyzed using the ImageJ software (http://rsb.info ...
-
bioRxiv - Neuroscience 2023Quote: ... The STG was then illuminated for 5-7 mins using a Texas red filter set (560 ± 40 nm wavelength; Leica Microsystems). Complete photoinactivation was confirmed when the LP membrane potential reached 0 mV ...
-
bioRxiv - Microbiology 2023Quote: ... as described above, the cells were incubated (37°C, 5% CO2) inside the Mica Microhub system using the internal incubator (Leica microsystems). Videos were analysed using the complementary software (Leica microsystems).
-
bioRxiv - Neuroscience 2023Quote: ... The STG was then illuminated for 5-7 mins using a Texas red filter set (560 ± 40 nm wavelength; Leica Microsystems). Complete photoinactivation was confirmed when the LP membrane potential reached 0 mV.
-
bioRxiv - Neuroscience 2023Quote: ... the brain was briefly submerged in ice cold cut solution bubbled with carbogen (95% oxygen, 5% CO2) and then sectioned into 300μm sagittal sections (Leica VT1200S vibratome) in bubbled ice-cold cut solution ...
-
bioRxiv - Developmental Biology 2023Quote: ... before being embedded in 5% low-melting agarose and sectioned into 100-400 μm-thick slices using a Vibratome (Leica, VT1200). Slices were blocked and permeabilized using PBST supplemented with 5% donkey serum and 0.3% Triton X at room temperature for 30 minutes ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... and 5% H2O) under liquid nitrogen and placed in an automatic freeze substitution system (Leica AFS2, Leica Microsystems, precooled to −90 ℃) for 24 h ...
-
bioRxiv - Neuroscience 2024Quote: Mice were anesthetized using vaporized isoflurane (5% for induction, 1.5% for maintenance) and placed in a stereotactic frame (Leica, Angle 2). Opthalmic ointment was applied and rectal temperature and respiration rate were monitored throughout surgery ...
-
bioRxiv - Cell Biology 2024Quote: ... Paraffin-embedded WAT was sliced into 5-μm sections using a ThermoScientific HM 355S Automatic Microtome and mounted on Surgipath X-tra Microscope Slides (Leica Biosystems).
-
bioRxiv - Neuroscience 2024Quote: ... the lumbar spinal cord from L3-5 was mounted on an agarose mold and the dorsal halve was micro dissected on a vibratome (Leica Microsystems). Next ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... The paraffin blocks were polymerized at 4°C and cut into 5-µm thick sections using a microtome (RM2155, Leica, Germany). The sections were mounted on microscope slides coated with egg white-glycerin and stained using Delafield’s Hematoxylin and Eosin (HE ...
-
bioRxiv - Cell Biology 2024Quote: ... Samples were mounted on an aluminum stub with a silver lacquer and sputtercoated with a 5 nm platinum layer using EM ACE600 (Leica Microsystems). Acquisitions were performed using a GeminiSEM 500 (Zeiss).
-
bioRxiv - Evolutionary Biology 2023Quote: ... LEGE 07298 and Phormidesmis priestleyi ULC 007 stained with either calcein or 5-CF were acquired with an inverted confocal laser scanning microscope (CLSM; Leica SP8) using a HC PL APO x63/1.40 oil objective ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... The paraffin blocks were polymerized at 4°C and cut into 5 µm thick sections using a microtome (RM2155: Leica, Wetzlar, Germany). The sections were mounted on microscope slides coated with egg white-glycerin and stained using Delafield’s Hematoxylin and Eosin staining ...
-
bioRxiv - Developmental Biology 2020Quote: Pregnant female mice (E3.5 and E9.5) were sacrificed by cervical dislocation for embryo dissections under a dissecting microscope (M165C or M80, Leica Microsystems; Wetzlar, Germany) as previously described (Behringer et al ...
-
bioRxiv - Immunology 2021Quote: ... Fixed tissue samples were then embedded in paraffin and 5 µm thick sections were cut at a rotary microtome (Leica, Wetzlar, Germany). After a 10 min incubation in PBS ...
-
bioRxiv - Neuroscience 2019Quote: Confocal images of double-stained neurons were acquired with a Leica SP-5 confocal microscope using a 63x oil-immersion objective (Leica, N.A. 1.4) as a z-series ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: we measured the teleochrysalid abdomen surface area (Troscianko, 2014) from high-resolution photos (Leica M50, 5 MP HD Microscope Camera Leica MC170 HD).
-
bioRxiv - Neuroscience 2020Quote: ... Coronal brain slices containing the hippocampal formation (400 μm thick) were prepared in the ice-cold cutting solution bubbled with 95% O2/5% CO2 using Vibratome VT1200S (Leica Microsystems, Germany). The slices were transferred into an interface chamber in ACSF containing (in mM) ...
-
bioRxiv - Cancer Biology 2019Quote: ... a minimum of 5 images were taken of cells per experiment using a 20x water objective on an inverted confocal microscope (Leica TCS SP8). Using phalloidin staining and Image J software ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... The paraffin blocks were polymerized at 4°C and cut into 5 µm thick sections using a microtome (RM2155: Leica, Wetzlar, Germany). The sections were mounted on microscope slides coated with egg white-glycerin and stained using Delafield’s Hematoxylin and Eosin staining ...
-
bioRxiv - Neuroscience 2021Quote: ... The brains were allowed to rest in cold oxygenated (95% O2/5% CO2) aCSF and then sliced coronally using a vibratome (Leica VT1000 S). Brain slices (400-μm thick sections ...
-
bioRxiv - Genetics 2022Quote: ... H&E staining was performed on 5 µm sections from paraffin-embedded retinas according to standard protocols for light microscopy and photomicrography (Leica, Wetzlar, Germany).
-
bioRxiv - Cell Biology 2020Quote: ... Cells were then imaged at 37°C in a chamber supplemented with humidified 5% CO2 through white light laser confocal microscope TCS SP8 (Leica, Wetzlar, Germany). Movie S1 was processed by Bitplane-Imaris 9.5 (Andor Technology ...
-
bioRxiv - Biophysics 2020Quote: ... stage of growth were imaged every 10 minutes for 12 hours in a customized incubator (37°C, 5% CO2, and 95% humidity) on a confocal microscope (Leica, TCL SP8), with acquisition of fluorescent and bright-field image z-stacks (Fig ...
-
bioRxiv - Bioengineering 2021Quote: ... The samples washed in PBS (3x 5 min) and embedded in Mowiol prior to confocal laser scanning microscope analysis (Leica TCS SP8X). Collagen fiber organization was determined as described in the supplementary information (supplementary Fig.S2-4 and supplementary Eq.S1.).
-
bioRxiv - Immunology 2021Quote: ... Lung tissue was embedded in Optimal Cutting Temperature Compound (Tissue-Tek) and 5 μm sections were cut on CM1950 Cyrostat (Leica, Weltzlar, Germany). Sections were blocked with 1% Rat serum and 1% FcBlock in PBS for 1 hr ...
-
bioRxiv - Immunology 2021Quote: ... Labelled live cells were imaged at 37 °C and 5% CO2 on a Leica Thunder Imager system (Leica Microsystems GmbH, Wetzlar, Germany), equipped with a xy motorized stage ...
-
bioRxiv - Immunology 2021Quote: ... Labelled live cells were imaged at 37 °C and 5% CO2 on a Leica Thunder Imager system (Leica Microsystems GmbH, Wetzlar, Germany), equipped with a xy motorized stage ...
-
bioRxiv - Microbiology 2022Quote: ... cells were imaged using a Stedycon optical setup (Abberior Instruments GmbH) integrated with Leica SP 5 microscope (Leica Microsystems GmbH, Manheim, Germany).
-
bioRxiv - Neuroscience 2022Quote: ... Fixed brains were washed three times for 5 min with PB and 150 µm-thick coronal sections were cut with a vibratome (Leica Microsystems, VT1000S). Tissue sections were labeled with DiIC18 (Invitrogen ...
-
bioRxiv - Neuroscience 2023Quote: ... Coronal and para-sagittal slices (300 μm) were prepared in ice-cold oxygenated (95% O2 / 5% CO2) ACSF with a vibratome (LeicaVT1000S, Leica Biosystems, Germany), then warmed to 36°C for 45 mins ...
-
bioRxiv - Neuroscience 2022Quote: ... Delineation of CA1.SR and MDG subregions were performed using light microscope under 5 × objective lens, the newCAST software (Visiopharm, Hørsholm, Denmark) modified for stereology with a digital camera (Leica DFC 295, Germany) and a motorized stage (Ludl Mac 5000 ...
-
bioRxiv - Plant Biology 2022Quote: ... The abaxial side of the leaf sample was imaged using a 63× objective (Leica, HC PL APO CS2 5 63×/1.20 Water). GFP was excited with a 488 nm WLL laser and collected at 503-530 nm ...
-
bioRxiv - Neuroscience 2022Quote: ... and cell volumes (tarsi 4–5) of the mCD8-RFP-labeled neurons were analyzed by using Leica Application Suite X (Leica RRID: SCR_013673) and Imaris software (Bitplane RRID ...
-
bioRxiv - Neuroscience 2023Quote: ... Serial sections were collected onto cover glasses and coated with gold with sputter current 30 mA for 5 seconds (Leica EM ACE200). Cover glasses were sealed on aluminum stabs using carbon tape ...
-
bioRxiv - Cell Biology 2023Quote: ... Samples were mounted on aluminum stubs with carbon adhesive tabs and coated with 5 nm each of carbon and iridium (Leica ACE 600). Prepared samples were imaged on a Zeiss Merlin FE-SEM using an InLens detector at 1.2 – 1.5 kV and 400 – 500 pA depending on the sample ...
-
bioRxiv - Molecular Biology 2023Quote: ... then cryoprotected with 20% sucrose in PBS for 24 hours at 4°C and cut in 5-µm-consecutive thick longitudinal sections using a freezing sliding microtome (Leica 2000R, Germany). Interstitial fibrosis was assessed via Picro Sirius Red Stain Kit (Abcam ...
-
bioRxiv - Neuroscience 2023Quote: ... Brain sections were cut at 30 µm and BAT sections were cut at 5 µm using a cryostat (Leica Biosystems, Nussloch, Germany). Brain sections were labelled with Anti-FLAG M2 F1804 ...
-
bioRxiv - Plant Biology 2023Quote: ... Stems were rehydrated first in ethanol 50% and later in water and then embedded in agarose 5% before being transversally cut using a vibratome (Leica vt 1000s) to obtain 120 micron thickness sections stored in water ...
-
Apical expansion of calvarial osteoblasts and suture patency is dependent on graded fibronectin cuesbioRxiv - Developmental Biology 2023Quote: ... the nuclei were stained with DAPI (1:2000) and the images were captured with 63X oil immersion objective by the confocal microscope (Leica STELLARIS 5). The measurements related to cell shape analysis of the nuclei in apical ...
-
bioRxiv - Developmental Biology 2023Quote: The images were initially processed in Fiji with a customed macro to batch open the lif files (Image taken on Leica Stellaris 5) and split the images into individual channels ...
-
bioRxiv - Cell Biology 2020Quote: ... cells were loaded with fura-2/AM in the dark (5 μM; 30 min; RT; S1) and imaged with an upright microscope (Leica DMI6000FS, Leica Microsystems) equipped for ratiometric live-cell imaging with a 150W xenon arc lamp ...
-
bioRxiv - Microbiology 2019Quote: ... at pH 2.5 to quantify mucous cells in the gills per inter-lamellar unit (ILU) under a bright field light microscope (Leica DM1000, Hamburg, Germany) (29 ...
-
bioRxiv - Immunology 2022Quote: ... was performed on sections (5 mm thick) of formalin-fixed lung mounted onto charged glass slides using the Leica Bond RX automated system (Leica Biosystems, Richmond, IL). Heat-induced epitope retrieval was conducted by heating slides to 95°C for 15 minutes in EDTA-based ER2 buffer (Leica Biosystems) ...
-
bioRxiv - Neuroscience 2020Quote: ... and 11 glucose saturated with 95% O2–5% CO2 and horizontal brain slices (150 μm thick) containing the VTA were prepared using a Vibratome (Leica Instruments, Nussloch, Germany). Slices were and allowed to recover at 35°C for at least 1 hr before recordings were initiated ...