Labshake search
Citations for Leica :
1751 - 1800 of 2007 citations for 7 chloro 1 2 diethylamino ethyl 5 2 fluorophenyl 1 3 dihydro 2H benzo 1 4 diazepin 2 one monohydrochloride since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Developmental Biology 2021Quote: Live imaging of Rx3::H2B-GFP-derived organoids (Video 5 and 6) was performed with Sp8 confocal microscope (Leica). Organoids were imaged from day 1 to day 2 at room temperature directly in low binding 96-well plate (Nunclon Sphera U-Shaped Bottom Microplate ...
-
bioRxiv - Zoology 2021Quote: ... Tissue sections with 5 μm thickness were cut using a microtome (Leica RM2235, Leica Biosystems Inc., Buffalo Grove, USA), fixed on slides ...
-
bioRxiv - Cancer Biology 2022Quote: ... Invading cells were imaged with a sCMOS Orca-Flash 4.0LT camera (Hamamatsu) coupled 5 to an inverted DMi8 microscope (Leica), capturing serial z-stacks every 10 µm with a 10× objective (dry ACS APO 10x/NA 0.3) ...
-
bioRxiv - Cell Biology 2022Quote: ... The cells were observed in 5% CO2 at 37°C using an HC PL APO 63 ×/1.40 oil objective (Leica). FAOBlue was excited at 405 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... bubbled with 95% O2-5% CO2 and sliced using a Vibratome (Leica VT1200, Leica Microsystems Inc, Buffalo Grove IL) except for experiments in which high Ca2+ concentrations were used ...
-
bioRxiv - Neuroscience 2020Quote: ... Sections of 100µm were performed at medium speed (around 5) and amplitude (approx. 6) using a vibratome Leica VT1000S (Leica). Sections were placed on a glass slide for immunostaining.
-
bioRxiv - Neuroscience 2021Quote: ... The paraffin-embedded brains were sectioned in the coronal plane at 5 µm using a microtome (Leica RM 2265). Sections were collected at 40 μm intervals ...
-
bioRxiv - Cell Biology 2022Quote: ... Fluorescence images of stained myotubes were obtained in 5 different areas using a DMI 3000 B microscope (Leica, Germany) and analyzed using ImageJ 1.52 software (National institutes of Health ...
-
bioRxiv - Cell Biology 2019Quote: ... right after the processing and then sectioned at 5 µm by using Leica RM2255 (Leica Biosystems, Buffalo Grove, IL) for histological staining.
-
bioRxiv - Physiology 2021Quote: ... Undecalcified 5 μm and 10 μm thick longitudinal sections were obtained using a microtome (RM2255, Leica Biosystems., IL, USA). 5 μm sections were stained with Goldner Trichome and at least two nonconsecutive sections per sample were examined for measurement of cellular parameters ...
-
bioRxiv - Cell Biology 2020Quote: ... The cells were observed in 5% CO2 at 37°C using an HC PL APO 63x/1.40 oil objective (Leica). Multichannel time-lapse images were acquired in 4 fields each with 4 averages per frame in 1-min or 1.5-min intervals ...
-
bioRxiv - Immunology 2021Quote: ... Organs included in paraffin were cut to a thickness of 5 microns (Microtome Leica RM2245 of disposable metal blades) and placed in a flotation solution in a water bath and then fixed on a slide sheet ...
-
bioRxiv - Plant Biology 2020Quote: ... The embedded blocks were transversely sectioned at 5 to μm thickness using a Leica RM2125RT rotary microtome (Leica Microsystems) on RNase-free polyethylene naphthalate PEN membrane slides (Leica) ...
-
bioRxiv - Neuroscience 2020Quote: ... At least 5-10 flies per genotype were scanned using the Confocal Laser Scanning Platform Leica SP8 (Leica, Germany). Samples were excited with an argon laser at 488nm (20% tube current) ...
-
bioRxiv - Physiology 2022Quote: ... The samples were imbedded in paraffin followed by serial sectioning at 5 µM thickness using the Leica microtome (Leica). The sections were deparaffinized ...
-
bioRxiv - Biochemistry 2023Quote: ... The paraffin-embedded tissues were sectioned (5 µm thick) with a semi-automated rotary microtome (Leica Microsystems, Wetzlar, Germany) and placed on microscope glass slides coated with poly-L-lysine ...
-
bioRxiv - Neuroscience 2022Quote: ... mice were anaesthetized using 2.5% isoflurane and 1.5 l/min air for 5 min and impacted directly over their intact head using an electromagnetic impactor (Leica Impact One Stereotaxic impactor ...
-
bioRxiv - Bioengineering 2023Quote: ... the grips were attached to a custom mechanical testing rig mounted on an upright confocal microscope (Leica STELLARIS 5) in a bath with 1× PBS (Fig ...
-
bioRxiv - Bioengineering 2022Quote: ... and placed on a microscope slide to image with a confocal microscope (Leica Stellaris 5 confocal with DMI 8). The settings for fluorescent imaging were calibrated using a positive control ...
-
bioRxiv - Bioengineering 2023Quote: ... Images (n = 5) of S-shape embedded filaments were taken with a confocal microscope (SPX8, Leica Microsystems, The Netherlands) and analyzed with ImageJ ...
-
bioRxiv - Biophysics 2023Quote: ... Stellaris 5 up-right system using either a HC APO L U-V-I 10x/0.30 NA WATER (Leica) or a HC FLUOTAR L VISIR 25X/0.95 NA WATER (Leica ...
-
bioRxiv - Neuroscience 2024Quote: ... PL Apo 40x/0.85 CORR CS and PL APO 63x/1.40 oil CS2 and Leica Stellaris 5 confocal microscopes (Leica Microsystems) equipped with a HCPL FLUOTAR 10x/0.30 ...
-
bioRxiv - Neuroscience 2024Quote: ... saturated with 95 % O2 and 5 % CO2 to obtain 250 μm-thick coronal sections with a vibratome (Leica VT1200S). Slices were transferred and incubated in a holding chamber containing (ACSF ...
-
bioRxiv - Biophysics 2023Quote: ... They were imaged with sequential z-stacks using a similar procedure as for the 3D colonies but with an 5× air objective (Nplan5×0.12PHO, Leica). The voxel size in (x,y,z ...
-
bioRxiv - Developmental Biology 2024Quote: Fixed samples were imaged in a Leica Stellaris 5 upright confocal microscope using a HC PL APO 40x/1,1 Water CORR CS2 objective (#506425, Leica). The microscope was operated by the LAS X (v4.5.0.25531 ...
-
bioRxiv - Immunology 2024Quote: ... The stage-top chamber was set onto the stage of a Stellaris 5 confocal microscope (Leica Microsystems, Deerfield, IL). Transmitted (brightfield ...
-
bioRxiv - Cell Biology 2020Quote: Sample blocks were obtained by freeze substitution of the cell pellets in 0.5 % uranyl acetate diluted from a 20 % stock in methanol and 3 % double distilled H2O in acetone in a Leica AFS1 (Leica Microsystems GmbH, Wetzlar, Germany). Temperature was set to −130 °C for the first 2 hours and then raised to −90 °C with a 20 °C/hr gradient ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Samples were imaged in brightfield using a Point Grey Flea®3 color camera (Teledyne FLIR, Wilsonville, OR) mounted on a Leica S8 APO stereo microscope (Leica Camera, Wetzlar, Germany). Representative images are shown.
-
bioRxiv - Pathology 2021Quote: Four micron thick sections of left and right ventricular FFPE tissue blocks per decedent were cut and labeled using an automated staining platform (Leica Bond 3, Leica Biosystems, Buffalo Grove, IL) with the following monoclonal antibodies against ...
-
bioRxiv - Neuroscience 2021Quote: ... Brains were rinsed 3 times in phosphate buffered saline and 50 μM coronal brain slices were obtained using a vibratome (Leica VT1000, Buffalo Grove, Il), without embedding the tissue ...
-
bioRxiv - Bioengineering 2022Quote: ... Samples were washed an additional 3 times in 100% ethanol for 15 minutes each and dried using a Leica EM CPD030 critical point dryer (Leica Microsystems, Buffalo Grove, IL) with CO2 as the transitional medium ...
-
bioRxiv - Bioengineering 2023Quote: ... were acquired over a ∼30 mm x ∼3 mm rectangular area by using the tile scan feature of the LAS X software (Leica Microsystems, Buffalo Grove, IL). This involved frame by frame acquisition (36 × 5 = 180 frames ...
-
bioRxiv - Cell Biology 2019Quote: ... submersed in the media chamber containing 4°C Phosphate buffered Saline and cut using a Leica VT1200S vibrating blade microtome (Leica Biosystems, UK) at a speed 0.3mm/sec ...
-
bioRxiv - Cell Biology 2020Quote: ... Tissues were embedded in 4% low temperature gelling agarose and cut into 100-150 micrometer thick section using a vibratome (Leica VT1200 S). The Proximity Ligation Assay (PLA ...
-
bioRxiv - Cancer Biology 2021Quote: Larvae fixed in 4% PFA overnight at 4°C were embedded in 4% low melting temperature agarose and transverse sections collected at 200 µm intervals using a vibrating microtome (Leica VT 1000S). Sections were blocked with 1% BSA in PBS/0.3% Triton X-100 and incubated with a 1:750 dilution of mAb414 (Abcam ...
-
bioRxiv - Neuroscience 2020Quote: ... brains were incubated in 10% and then 30% sucrose in PBS for 12-24 hours at 4 °C before being cut into 50 µm sections by a freezing-sliding microtome (Leica SM 2101R). Sections from V1 were mounted on gelatin-coated slides and cover-slipped with Prolong Diamond Antifade Mounting Media (P36965 ...
-
bioRxiv - Neuroscience 2020Quote: ... brains were post-fixed for 24 hours and then included in agar 4% and serial cuts of 40 µm thick were made using vibratome (Leica Biosystems, S2000).
-
bioRxiv - Cancer Biology 2021Quote: ... The specimens were embedded in paraffin blocks and serial sections of 4 μm thickness were cut using a microtome (Leica Biosystems, Germany). The sections were stained by Hematoxylin & Eosin (H&E)34 Histological photographs were obtained using a digital light microscope (Olympus ...
-
bioRxiv - Neuroscience 2020Quote: ... Brains were postfixed in 4 % PFA for 24 hours until they were sliced (70 µm thickness) using a Leica Vibratome (Leica, Wetzlar, Germany). Slices were directly mounted on an object slide (Gerhard Menzel ...
-
bioRxiv - Neuroscience 2019Quote: ... Brains were post-fixed overnight in 4% paraformaldehyde and then cryoprotected in a 30% sucrose and 0.1M PBS solution prior to sectioning (Leica CM3050S, Leica Biosystems). Three sets of immediately adjacent sections (40 μm ...
-
bioRxiv - Neuroscience 2020Quote: ... brains were incubated in 10% and then 30% sucrose in PBS for 12-24 hours at 4 °C before being cut into 50 µm sections by a freezing-sliding microtome (Leica SM 2101R). Sections with LGN and V1 were then mounted on gelatin-coated slides and cover-slipped with mounting media (Prolong Diamond Antifade Mounting Media ...
-
bioRxiv - Molecular Biology 2022Quote: ... Green siliques were harvested 12 d after flowering from 4-6 week old plants and opened using fine needles under a dissecting microscope (Leica MZ9.5, Germany). Images of opened siliques were captured using a Leica DFC290 (Germany ...
-
bioRxiv - Microbiology 2022Quote: ... Grids were sputter-coated with a ∼4 nm thick layer of tungsten using ACE600 cryo-sputter coater (Leica Microsystems GmbH, Vienna, Austria) and afterwards transferred into a Crossbeam 550 FIB-SEM dual-beam instrument (Carl Zeiss Microscopy ...
-
bioRxiv - Neuroscience 2021Quote: ... The brains were post-fixed overnight in 4% PFA and stored in PBS until histological slicing was performed using a vibratome (Leica VT1200 S) and the slices were mounted in DAPI-Fluoromount-G (70-100 µm slices ...
-
bioRxiv - Developmental Biology 2022Quote: ... Electroporated hemispheres were infiltrated with 30% sucrose at 4°C overnight prior to embedding in TissueTek tissue freezing medium (Leica Biosystems, Germany). 16 µm-thick sections were cut using a cryostat (Leica Biosystems ...
-
bioRxiv - Plant Biology 2019Quote: ... A series of 4-μm thick longitudinal sections and transverse sections (rapidly elongating region) were made with a rotary microtome RM2265 (LEICA EM UC7). Fixed sections were stained with toluidine blue O for 30 min and photographed with an Olympus BX51 microscope equipped with a DP74 camera.
-
bioRxiv - Neuroscience 2019Quote: ... Brains were postfixed in 4% paraformaldehyde overnight on a shaker at 4°C and cut into 50 μm coronal sections on a vibrating microtome (Leica, VT-1000S), with sections collected into six tubes (containing cryoprotectant solution as described[32] ...
-
bioRxiv - Cancer Biology 2021Quote: ... Formalin-fixed paraffin-embedded (FFPE) samples were cut to a thickness of 4 μm and stained on an automated stainer (BOND-MAX, Leica Biosystems, Germany) as part of the diagnostic routine in a clinically accredited histology lab ...
-
bioRxiv - Immunology 2020Quote: ... at which time tissues were removed from the BSL-3 laboratory and stored in 1X PBS at 4°C until processed in a Leica PELORIS automated vacuum infiltration processor (Leica, Wetzlar, Germany), followed by paraffin embedding with a Histocore Arcadia paraffin embedding machine (Leica) ...
-
bioRxiv - Cell Biology 2021Quote: ... Osmicated samples were dehydrated in graded ethanols (25% to 100%) at 4°C and stored in 100% acetone until critical point drying with liquid CO₂ (EM CPD300, Leica Microsystems Ltd.). Samples were mounted onto stubs using silver paint (Agar Scientific) ...