Labshake search
Citations for Leica :
51 - 100 of 858 citations for Mouse Anti Hepatitis B Virus E Antigen Antibody 1893 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2022Quote: ... Sections for Ly6G underwent antigen retrieval using ER2 solution (AR9640, Leica) for 20 minutes at 95°C ...
-
bioRxiv - Cancer Biology 2022Quote: ... tissue sections were treated with antigen retrieval solution (Leica Microsystems, AR9640) with heat near 100°C for 20 minutes ...
-
bioRxiv - Cancer Biology 2022Quote: ... and retrieved antigens with an automated immunostainer (Bond RX, Leica Biosystems). Antigen retrieval was performed in a Tris-EDTA buffer for 30 min at 95°C for Ki-67 (1:200 ...
-
bioRxiv - Physiology 2023Quote: ... antigen retrieval was carried out with BondTM citrate solution (AR9961, Leica), BondTM EDTA solution (AR9640 ...
-
bioRxiv - Cancer Biology 2023Quote: ... Ki67 and Fibronectin underwent antigen retrieval using ER2 solution (AR9640, Leica) for 20 minutes at 100°C ...
-
bioRxiv - Cancer Biology 2021Quote: ... The slides were incubated with a secondary antibody (rabbit anti-mouse IgG, BOND Polymer Refine Detection System, Leica, Germany, DS9800) for 8 minutes at room temperature ...
-
bioRxiv - Genetics 2021Quote: Assessment of Aβ deposition was carried out by immunohistochemical staining of paraffin-embedded sections (3–5 μm-thick) with a mouse monoclonal (S6 F/3D) anti-Aβ antibody (Leica Biosystems Newcastle Ltd ...
-
bioRxiv - Cancer Biology 2022Quote: ... H&E sections were stained following the Harris H&E staining protocol using a multi-stainer instrument (Leica ST5020). p53 staining was performed on 3μm FFPE sections using the Leica Bond Max fully automated IHC system ...
-
bioRxiv - Bioengineering 2022Quote: ... or Leica DMI4000 B (Leica) at 6 and 12 hours ...
-
bioRxiv - Microbiology 2020Quote: ... The lid (Type B, Leica) was dipped in 1-hexadecene and placed on top of the sample carrier ...
-
bioRxiv - Cancer Biology 2022Quote: ... Hematoxylin/eosin (H&E) staining was performed with H&E Leica Kit Infinity for a full automated autostainer (Leica ST5020). IHC staining for Ki67 and MGP antibodies was performed using Bond III IHC autostainer for full Automated Immunohistochemistry (Leica biosystems) ...
-
bioRxiv - Cancer Biology 2022Quote: ... Thin sections (70 nm; Leica-Reichert Ultracut E) collected at different levels of each block were counterstained with 1.5% uranyl acetate in 70% ethanol and lead citrate and observed using a Tecnai F20 transmission electron microscope at 200 KV at the CoMET MRI facilities ...
-
bioRxiv - Cancer Biology 2022Quote: ... Thin sections (70 nm; Leica-Reichert Ultracut E) were collected at different levels of each block ...
-
bioRxiv - Cell Biology 2023Quote: ... Ultrathin sections (70 nm; Leica-Reichert Ultracut E) were collected from different levels of each block ...
-
bioRxiv - Neuroscience 2023Quote: ... Thin sections (70 nm; Leica-Reichert Ultracut E) were collected at different levels of each block ...
-
bioRxiv - Neuroscience 2024Quote: ... Thin sections (70 nm; Leica-Reichert Ultracut E) were collected at different levels of each block ...
-
bioRxiv - Neuroscience 2020Quote: ... mouse anti-GFAP (PA0026, Leica Biosystems, Wetzler, Germany), or mouse anti-Factor VIII (ab41187 ...
-
bioRxiv - Neuroscience 2022Quote: ... GFAP (anti-GFAP (mouse, GA5, Leica, 1:200) and IBA1 (1:1000 Wako ...
-
bioRxiv - Cancer Biology 2023Quote: ... PowerVision Poly-HRP anti-Mouse IgG (Leica, PV6119) as the secondary antibody ...
-
bioRxiv - Cancer Biology 2022Quote: ... mouse-anti-TRP53 (CM5, Novocastra™ Leica Biosystems); mouse-anti-p19/ARF (5.C3.1 ...
-
bioRxiv - Cancer Biology 2020Quote: ... Antigen-binding sites were detected with a polymer-based detection system (Leica Biosystems UK ...
-
bioRxiv - Immunology 2022Quote: ... The antigen retrieval was performed with Bond ER Solution #1 (Leica Biosystems) equivalent to citrate buffer ...
-
bioRxiv - Immunology 2021Quote: ... Antigen retrieval was performed in BOND Epitope Retrieval Solution 1 (Leica, AR9961). Primary antibody APOE (Abcam ...
-
bioRxiv - Cancer Biology 2022Quote: ... Antigen retrieval was performed in BOND Epitope Retrieval Solution 1 (Leica, AR9961) for 20 minutes at high pressure in a pressure cooker ...
-
bioRxiv - Neuroscience 2020Quote: ... Stereotaxic virus injections were performed using an Angle Two apparatus (Leica) linked to a digital brain atlas (Leica Biosystems Richmond ...
-
bioRxiv - Neuroscience 2021Quote: ... and epifluorescence (Leica DM 6000 B) microscopy for high magnification 3D reconstruction and low magnification imaging ...
-
bioRxiv - Cell Biology 2023Quote: ... using a microscope (DMI4000 B; Leica) equipped with a 63x 1.3-NA glycerol-immersion objective lens ...
-
bioRxiv - Cancer Biology 2021Quote: ... paraffin-embedded tissues was carried out on a Discovery XT automated slide stainer using a mouse anti-human monoclonal antibody for FOLR1 (Novocastra Clone BN3.2; Leica Biosystems, Wetzlar, Germany) at 15 µg/ml after antigen retrieval with Cell Conditioning 1 (CC1 ...
-
bioRxiv - Cancer Biology 2022Quote: ... and incubated overnight at 4°C in 0.05% Digitonin-Antibody buffer containing a rabbit anti mouse-p53 Ab (1:100 Leica, NCL-p53-CM5p). Samples incubated with rabbit IgG (1:150 ...
-
bioRxiv - Immunology 2021Quote: ... Chromatin was incubated with primary antibody against mouse p53 (CM5, Leica) overnight followed by two hours of conjugation to Protein A+G conjugated magnetic beads ...
-
bioRxiv - Cancer Biology 2020Quote: ... The immunostaining for all antigens was performed on an automated staining system (Leica Bond RX ...
-
bioRxiv - Microbiology 2021Quote: ... Antigen retrieval was performed by epitope retrieval (ER) 2 solution (Leica, pH 9). The slides were then incubated with anti-E-cadherin ...
-
bioRxiv - Cancer Biology 2021Quote: ... The immunostaining for all antigens was performed on an automated staining system (Leica Bond RX ...
-
bioRxiv - Immunology 2022Quote: ... sections were antigen retrieved with ER solution 1 (Leica Microsystems, catalog no. AR9961), protein block was applied for 30 mins (Leica Microsystems ...
-
bioRxiv - Cancer Biology 2023Quote: ... and antigen retrieval was performed using BOND Epitope Retrieval Solution 1 (Leica Biosystems) at 100°C for 20 minutes ...
-
bioRxiv - Neuroscience 2023Quote: ... Antigen retrieval was done using Epitope retrieval buffer 1 (pH 6; Leica biosystems) for 20 minutes ...
-
bioRxiv - Microbiology 2020Quote: ... An ultramicrotome (Reichert Utralcut E, Leica Microsystems, Wetzlar, Germany) and a diamond knife were used to obtain ultrathin sections (80 nm ...
-
bioRxiv - Microbiology 2020Quote: ... An ultramicrotome (Reichert Ultralcut E, Leica Microsystems, Wetzlar, Germany) and a diamond knife (Delaware Diamond Knives ...
-
bioRxiv - Genomics 2021Quote: ... 70nm sections were cut using Ultra cut E (Leica) and stained with 2% uranyl acetate and Reynold’s lead citrate ...
-
bioRxiv - Cancer Biology 2021Quote: ... mouse anti-MUC2 (1:50, Leica, NCL-MUC-2), mouse anti-CK17 (1:10 ...
-
bioRxiv - Immunology 2019Quote: ... A mouse monoclonal anti-CD3ε (clone LN10, Leica Biosystems) was used to stain for pig T cells ...
-
bioRxiv - Cancer Biology 2023Quote: ... rehydrated and subsequently stained with hematoxylin and eosin (H&E) and appropriate antibodies (Supplementary Table 3) using the automated system BOND RX (Leica Biosystems, Newcastle, UK). Visualization was by the Bond Polymer Refine Detection kit (Leica Biosystems ...
-
bioRxiv - Neuroscience 2020Quote: ... anti-glial fibrillary acidic protein (GFAP; mouse anti-human monoclonal antibody GA5, with bond heat-induced epitope retrieval, epitope retrieval time 10 min, PA0026; Leica Biosystems, Wetzlar, Germany); anti-ionized calcium-binding adapter molecule 1 (IBA1 ...
-
bioRxiv - Cancer Biology 2022Quote: ... 20uL of anti-p53 antibody (CM5, Leica Biosystems was added to lysate and incubated overnight ...
-
bioRxiv - Developmental Biology 2019Quote: ... β-Dystroglycan (1:100; Leica #NCL-b-DG), aPKCς clone C-20 (1:400 ...
-
bioRxiv - Cell Biology 2019Quote: ... using a DMI4000 B inverted microscope (Leica).
-
bioRxiv - Neuroscience 2021Quote: ... using an epifluorescence microscope (Leica DMI6000 B) equipped with a confocal device (Revolution DSD2 ...
-
bioRxiv - Microbiology 2022Quote: ... on an inverted microscope (Leica Dlll3000 B) and deposited in multiwell plates with marine or fresh water containing 1% YT medium (100 mg of yeast extract ...
-
bioRxiv - Genomics 2022Quote: Deparaffinization and antigen retrieval were performed automatically on a BOND RX machine (Leica Biosystems) using Bond Dewax Solution (30 seconds at 72°C ...
-
bioRxiv - Cancer Biology 2021Quote: ... The sections were pre-treated using heat mediated antigen retrieval with EDTA pH9 (Leica Biosystem Epitope Retrieval Solution 2 ...